Hao Wu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Hao Wu has a total of 38 co-authors. Here are the top co-authors by number of shared publications:
Peng Wu
Chinese Academy of Science
3 shared publicationsChun-Lei Du
Yangtze Normal University
2 shared publicationsHong-Liang Cui
Chinese Academy of Sciences
2 shared publications- Tianying Chang
Shenzhen Institutes of Advanced Technology Chinese Academy of Sciences Shenzhen Guangdong China
2 shared publications Bi-Ying Hu
1 shared publication- Chun-Lei Du
Yangtze Normal University, 117787 Fuling, Chongqing, China
1 shared publication
Latest Publications
- 27 November 2023
- Published by Optica Publishing Group in Optics Express
- Vol. 31 (25) , 41622-41634
Weak-value amplified surface plasmon resonance sensor based on joint detection of optical activity and refractive index
A versatile system combining surface plasmon resonance (SPR) and weak value amplification (WVA) is presented, which can measure the optical activity and refractive index of chiral/achiral molecules, ionic compounds, and their mixture in solution individually or simultaneously. The variations in output light intensity directly exhibit high sensitivity to changes in optical activity and refractive index of the aforementioned substances. Furthermore, by examining the correlation between the intensity variation trend and the optical activity of the chiral molecule, the molecule's absolute configuration can be ascertained. Utilizing this instrument, optical rotation with a resolution of 3.04 × 10−6 rad and refractive index with a resolution of 5.57 × 10−9 RIU were obtained. As an attempt at practical application, this sensor was used to detect the adulteration of glucose and fructose in pure honey. Not only can such compromised honey be distinguished from pure honey using the refractive index or optical rotation, but the difference in optical activity can also be employed to effectively differentiate between adulterated honey samples containing glucose and fructose separately.
- 27 November 2023
- Published by Optica Publishing Group in Optics Express
- Vol. 31 (25) , 41622-41634
Weak-value amplified surface plasmon resonance sensor based on joint detection of optical activity and refractive index
A versatile system combining surface plasmon resonance (SPR) and weak value amplification (WVA) is presented, which can measure the optical activity and refractive index of chiral/achiral molecules, ionic compounds, and their mixture in solution individually or simultaneously. The variations in output light intensity directly exhibit high sensitivity to changes in optical activity and refractive index of the aforementioned substances. Furthermore, by examining the correlation between the intensity variation trend and the optical activity of the chiral molecule, the molecule's absolute configuration can be ascertained. Utilizing this instrument, optical rotation with a resolution of 3.04 × 10−6 rad and refractive index with a resolution of 5.57 × 10−9 RIU were obtained. As an attempt at practical application, this sensor was used to detect the adulteration of glucose and fructose in pure honey. Not only can such compromised honey be distinguished from pure honey using the refractive index or optical rotation, but the difference in optical activity can also be employed to effectively differentiate between adulterated honey samples containing glucose and fructose separately.
- 30 June 2023
- Published by Optica Publishing Group in Optics Express
- Vol. 31 (14) , 23642-23650
A nano-radian precision absolute local slope measurement method for X-ray reflectors
Ultra-precise reflectors in the advanced light source facilities urgently call for local slope error measurements with nano-radian precision. However, the existing methods currently utilized in the long trace profiler systems struggle to meet the requirements. In this paper, we present a weak-value amplification enhanced absolute local slope measurement scheme, in which the surface height difference between two adjacent points can be measured directly with precision on the pico-meter level. As a result, the absolute local slope measurement reaches a record precision level of 9.7 nrad (RMS) with a small lateral separation of 0.5 mm. Comparing to the existing methods, our scheme is more disturbance-resistant, more compact and cost-effective. The local curvature measuring capability is also validated with two synchronously parallel local slope measurement paths, between which the separation is set as 2mm. A local curvature measurement is obtained with precision of 3.4 × 10−6m−1 (RMS) and its corresponding slope variation is 6.8 nrad. Our method exhibits important application prospects in the field of ultra-precise surface fabrication inspection.
- 30 June 2023
- Published by Optica Publishing Group in Optics Express
- Vol. 31 (14) , 23642-23650
A nano-radian precision absolute local slope measurement method for X-ray reflectors
Ultra-precise reflectors in the advanced light source facilities urgently call for local slope error measurements with nano-radian precision. However, the existing methods currently utilized in the long trace profiler systems struggle to meet the requirements. In this paper, we present a weak-value amplification enhanced absolute local slope measurement scheme, in which the surface height difference between two adjacent points can be measured directly with precision on the pico-meter level. As a result, the absolute local slope measurement reaches a record precision level of 9.7 nrad (RMS) with a small lateral separation of 0.5 mm. Comparing to the existing methods, our scheme is more disturbance-resistant, more compact and cost-effective. The local curvature measuring capability is also validated with two synchronously parallel local slope measurement paths, between which the separation is set as 2mm. A local curvature measurement is obtained with precision of 3.4 × 10−6m−1 (RMS) and its corresponding slope variation is 6.8 nrad. Our method exhibits important application prospects in the field of ultra-precise surface fabrication inspection.
- Open Access
A novel robot calibration method with plane constraint based on dial indicator
In pace with the electronic technology development and the production technology improvement, industrial robot Give Scope to the Advantage in social services and industrial production. However, due to long-term mechanical wear and structural deformation, the absolute positioning accuracy is low, which greatly hinders the development of manufacturing industry. Calibrating the kinematic parameters of the robot is an effective way to address it. However, the main measuring equipment such as laser trackers and coordinate measuring machines are expensive and need special personnel to operate. Additionally, in the measurement process, due to the influence of many environmental factors, measurement noises are generated, which will affect the calibration accuracy of the robot. Basing on these, we have done the following work: a) developing a robot calibration method based on plane constraint to simplify measurement steps; b) employing Square-root Culture Kalman Filter (SCKF) algorithm for reducing the influence of measurement noises; c) proposing a novel algorithm for identifying kinematic parameters based on SCKF algorithm and Levenberg Marquardt (LM) algorithm to achieve the high calibration accuracy; d) adopting the dial indicator as the measuring equipment for slashing costs. The enough experiments verify the effectiveness of the proposed calibration algorithm and experimental platform.
Open AccessA novel robot calibration method with plane constraint based on dial indicator
In pace with the electronic technology development and the production technology improvement, industrial robot Give Scope to the Advantage in social services and industrial production. However, due to long-term mechanical wear and structural deformation, the absolute positioning accuracy is low, which greatly hinders the development of manufacturing industry. Calibrating the kinematic parameters of the robot is an effective way to address it. However, the main measuring equipment such as laser trackers and coordinate measuring machines are expensive and need special personnel to operate. Additionally, in the measurement process, due to the influence of many environmental factors, measurement noises are generated, which will affect the calibration accuracy of the robot. Basing on these, we have done the following work: a) developing a robot calibration method based on plane constraint to simplify measurement steps; b) employing Square-root Culture Kalman Filter (SCKF) algorithm for reducing the influence of measurement noises; c) proposing a novel algorithm for identifying kinematic parameters based on SCKF algorithm and Levenberg Marquardt (LM) algorithm to achieve the high calibration accuracy; d) adopting the dial indicator as the measuring equipment for slashing costs. The enough experiments verify the effectiveness of the proposed calibration algorithm and experimental platform.
- Open Access
- 1 January 2022
- Published by Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences in Acta Physica Sinica
- Vol. 71 (8) , 1-15
Phonon-mediated many-body quantum entanglement and logic gates in ion traps
高保真度的多离子纠缠和量子逻辑门是离子阱量子计算的基础, 其中Cirac-Zoller Gate和Mølmer-Sørensen Gate是比较成熟的实现多离子纠缠和量子逻辑门实验方案. 近年来, 还出现了通过设计超快脉冲激光序列在Lamb-Dicke区域以外实现超快量子纠缠和量子逻辑门的方案. 这些方案均借助离子链这一多体量子系统的声子能级来耦合离子之间的自旋状态, 并且实验上均通过调制激光脉冲或设计合适的脉冲序列来解耦多运动模式, 提高纠缠门的保真度. 本文从理论和实验层面分析了这些多体量子纠缠和量子逻辑门操作的核心技术, 揭示了离子阱系统中利用激光驱动离子链运动态, 通过非平衡过程中的非线性相互作用来实现量子逻辑门的基本物理过程.
- 1 January 2022
- Published by Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences in Acta Physica Sinica
- Vol. 71 (8) , 1-15
Open AccessPhonon-mediated many-body quantum entanglement and logic gates in ion traps
高保真度的多离子纠缠和量子逻辑门是离子阱量子计算的基础, 其中Cirac-Zoller Gate和Mølmer-Sørensen Gate是比较成熟的实现多离子纠缠和量子逻辑门实验方案. 近年来, 还出现了通过设计超快脉冲激光序列在Lamb-Dicke区域以外实现超快量子纠缠和量子逻辑门的方案. 这些方案均借助离子链这一多体量子系统的声子能级来耦合离子之间的自旋状态, 并且实验上均通过调制激光脉冲或设计合适的脉冲序列来解耦多运动模式, 提高纠缠门的保真度. 本文从理论和实验层面分析了这些多体量子纠缠和量子逻辑门操作的核心技术, 揭示了离子阱系统中利用激光驱动离子链运动态, 通过非平衡过程中的非线性相互作用来实现量子逻辑门的基本物理过程.
- Open Access
- 8 February 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Photonics Journal
- Vol. 13 (2) , 1-10
Pragmatic Implementation With Non-Gaussian Devices of Noise-Limited Weak Value Amplification
An effective approach for general measurement based on weak value amplification using non-Gaussian broadband light sources is demonstrated. This scheme can reduce the difficulty of preparing the measurement apparatus and correcting the systematic error caused by the imperfection of device's wave function, thus making the weak-value amplification scheme more convenient and robust for practical field applications. The influence of several common noise sources in a general application based on weak value amplification is analyzed theoretically and examined experimentally. A purely imaginary weak-value phase measurement system is considered for the noise model verification experimentally. In this we show how to optimize the precision of measurement in a unique solution that takes into account the interplay between precision and uncertainty, and explicate the ramifications of such a compromising and pragmatic approach
- 8 February 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Photonics Journal
- Vol. 13 (2) , 1-10
Open AccessPragmatic Implementation With Non-Gaussian Devices of Noise-Limited Weak Value Amplification
An effective approach for general measurement based on weak value amplification using non-Gaussian broadband light sources is demonstrated. This scheme can reduce the difficulty of preparing the measurement apparatus and correcting the systematic error caused by the imperfection of device's wave function, thus making the weak-value amplification scheme more convenient and robust for practical field applications. The influence of several common noise sources in a general application based on weak value amplification is analyzed theoretically and examined experimentally. A purely imaginary weak-value phase measurement system is considered for the noise model verification experimentally. In this we show how to optimize the precision of measurement in a unique solution that takes into account the interplay between precision and uncertainty, and explicate the ramifications of such a compromising and pragmatic approach
- 27 May 2020
- Published by IOP Publishing in Journal of Physics B: Atomic, Molecular and Optical Physics
- Vol. 53 (12) , 125401
Effects of nonlinearity and technical noise on weak-value amplified phase measurement
An exact nonlinear model for pointer shift estimation in phase measurement with weak-value amplification is presented, and the necessary assumptions for the linear approximations are discussed. A realistic experimental weak measurement system with pure imaginary weak-value is demonstrated to verify the nonlinear model, and it is shown that our model is effective over a wide dynamic range. In addition, the influence of several common-type technical noise on the uncertainty of pointer shift estimation in momentum space is analyzed theoretically and verified experimentally, in connection with the relationship between the working condition and the signal-to-noise ratio of the system. This close examination of the impact and ramifications of nonlinearity and technical noise in a realistic experimental phase measurement setting employing weak value amplification provides helpful guidance for its invocation in optical interferometric sensor design.
- 27 May 2020
- Published by IOP Publishing in Journal of Physics B: Atomic, Molecular and Optical Physics
- Vol. 53 (12) , 125401
Effects of nonlinearity and technical noise on weak-value amplified phase measurement
An exact nonlinear model for pointer shift estimation in phase measurement with weak-value amplification is presented, and the necessary assumptions for the linear approximations are discussed. A realistic experimental weak measurement system with pure imaginary weak-value is demonstrated to verify the nonlinear model, and it is shown that our model is effective over a wide dynamic range. In addition, the influence of several common-type technical noise on the uncertainty of pointer shift estimation in momentum space is analyzed theoretically and verified experimentally, in connection with the relationship between the working condition and the signal-to-noise ratio of the system. This close examination of the impact and ramifications of nonlinearity and technical noise in a realistic experimental phase measurement setting employing weak value amplification provides helpful guidance for its invocation in optical interferometric sensor design.