JDJulian Doll

Julian Doll

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Julian Doll has a total of 50 co-authors. Here are the top co-authors by number of shared publications:

  • Christian Fischer

    ARCUS Clinic Pforzheim, Pforzheim, Germany

    14 shared publications
  • Gerhard Schmidmaier

    Department for Trauma Surgery, Heidelberg University Hospital, Heidelberg, Germany

    12 shared publications
  • Sebastian I. Wolf

    Department for Orthopaedics, Heidelberg University Hospital, Heidelberg, Germany

    7 shared publications
  • Thomas Bruckner

    Institute of Medical Biometry and Informatics, University of Heidelberg, Heidelberg, Germany

    7 shared publications
  • Stefan Waizenegger

    Centre for Orthopaedics, Trauma Surgery and Spinal Cord Injury, Ultrasound Centre, Heidelberg Trauma Research Group (HTRG), Heidelberg University Hospital, Heidelberg, Germany

    6 shared publications
  • Arndt Neide

    Center for Orthopedics, Trauma Surgery and Spinal Cord Injury, Ultrasound Center, Heidelberg University Hospital, Heidelberg, Germany

    4 shared publications

Latest Publications

  • Differences in gait analysis and clinical outcome after dynamic fixation or screw fixation in acute syndesmosis tear: a prospective randomized pilot study

    by Paul Mick, Julian Doll, Michelle Müller, Gerhard Schmidmaier, Tobias Renkawitz, Sarah Campos, Sebastian I. Wolf, Stefanos Tsitlakidis

    Introduction Acute syndesmosis tears can be treated by static screw or dynamic fixation. Various studies have compared these techniques regarding postoperative outcome. However, to our knowledge, no study has used 3D-instrumented gait analysis (IGA). We hypothesized that a dynamic fixation would perform non-inferior to screw fixation in terms of biomechanical and clinical outcomes. Materials and methods Patients were prospectively randomized to both groups. All patients received the same follow-up rehabilitation and consultations (6 and 12 weeks; 6 and 12 months) postoperatively. Standardized questionnaires were used to objectify pain and ankle function. At 6 months follow-up, IGA was conducted additionally to objectify the biomechanical outcome. Results Twenty-five patients in the dynamic fixation (DF) group using TightRope® and twenty-five in the screw fixation group (SF) completed gait analysis. The DF group showed significantly higher mean values for maximum moment in the affected ankle joint (DF: 1.40 ± 0.21 Nm, SF: 1.23 ± 0.30 Nm; p = 0.023) and the unaffected ankle joint (DF: 1.52 ± 0.20 Nm, SF: 1.37 ± 0.27 Nm; p = 0.035). The difference between the affected and unaffected ankle joint was significantly higher in the SF group for active plantarflexion (DF: 1.52 ± 0.20°, SF: 1.37 ± 0.27°; p = 0.035). Both dynamic and screw fixation groups exhibited significantly reduced plantarflexion during the push-off and early swing phase, with moments and powers in the ankle joint also significantly impaired. Conclusions Our study demonstrated that dynamic fixation has better or similar biomechanical and clinical outcomes compared to screw fixation. Future research should focus on biomechanical differences during gait as well as clinical outcomes in case of earlier weight-bearing after dynamic fixation. Trial registration number (TRN) DRKS00013562 Date of Registration: 07/12/2017.


  • Open Access

    Gait Deviations of the Uninvolved Limb and Their Significance in Unilateral Cerebral Palsy

    by Stefanos Tsitlakidis, Sarah Campos, Paul Mick, Julian Doll, Sébastien Hagmann, Tobias Renkawitz, Marco Götze, Pit Hetto

    Little is known about the impact of the impaired limb on the uninvolved side, which might influence the overall functional outcome in individuals with unilateral cerebral palsy (CP). The objective of this work was to perform an assessment considering the kinematics/joint moments and ground reaction forces (GRFs). Eighty-nine individuals with unilateral CP were included and classified according to their functional impairment. Level-specific differences according to the Gross Motor Function Classification System (GMFCS), including pelvic and trunk movements, were analyzed using instrumented 3D gait analysis (IGA). Anterior trunk and pelvic tilt, trunk lean/pelvic obliquity, pelvic internal rotation, hip adduction, and external hip rotation, as well as pronounced flexion (ankle dorsiflexion), at all joint levels were significant kinematic alterations. Concerning joint moments, the most remarkable alterations were hip and ankle flexion, hip abduction, knee varus/valgus, and transversal joint moments at all levels (external rotation moments in particular). The most remarkable differences between GMFCS levels were at proximal segments. The kinematics and joint moments of the sound limb in patients with unilateral CP differ significantly from those of healthy individuals—partially concomitant to those of the involved side or as motor strategies to compensate for transversal malalignment and leg-length discrepancies (LLDs). GRF showed almost identical patterns between GMFCS levels I and II, indicating an unloading of the involved limb. Compensatory motor strategies of the sound limb do not influence functional outcomes.


  • Contrast-Enhanced Ultrasound–Assessed Supraspinatus Muscle Perfusion Indicates Better Tissue Vitality and Outcome After Supraspinatus Tendon Repair and Subacromial Decompression

    by Paul Mick, Zoe Holz, Tobias Renkawitz, Matthias Bülhoff, Julian Deisenhofer, Mustafa Hariri, Christian Fischer, Julian Doll


  • Open Access

    New perspectives for investigating muscular perfusion response after dietary supplement intake: an exploratory, randomized, double-blind, placebo-controlled crossover trial in healthy young athletes using contrast-enhanced ultrasound (CEUS)

    by Franziska Bürkle, Julian Doll, Arndt Neide, Simone Gantz, Stefanos Tsitlakidis, Christian Fischer

    Various dietary supplements have been reported to enhance muscular perfusion in athletes practicing resistance training, especially through modulation of nitric oxide signaling. The aim of this study was therefore to investigate selected ‘NO-boosting’ supplements in a real-life setting i) to generate novel hypotheses and perfusion estimates for power calculation in view of a definitive trial and ii) to assess the feasibility of the study design with particular focus on the use of contrast-enhanced ultrasound (CEUS) for perfusion quantification. Thirty young male athletes (24 ± 4 years) regularly practicing resistance training were enrolled in this three-arm, placebo(PL)-controlled crossover trial with ingestion of two commercially available supplements: an amino acid combination (AA) (containing 3 g of L-arginine-hydrochloride and 8 g of L-citrulline-malate) and 300 mg of a specific green tea extract (GTE). After intake, CEUS examinations of the dominant biceps brachii muscle were performed under resting conditions and following standardized resistance exercising. Quantitative parameters of biceps perfusion (peak enhancement, PE; wash-in perfusion index, WiPI) and caliber were derived from corresponding CEUS video files. Additionally, subjective muscle pump was determined after exercise. For PE, WiPI, and biceps caliber, the standard deviation (SD) of the within-subject differences between PL, AA, and GTE was determined, thereby allowing future sample size calculations. No significant differences between PL, AA, and GTE were observed for biceps perfusion, caliber, or muscle pump. When comparing resting with post-exercise measurements, the increase in biceps perfusion significantly correlated with the caliber increase (PE: r = 0.266, p = 0.0113; WiPI: r = 0.269, p = 0.0105). Similarly, the biceps perfusion correlated with muscle pump in the post-exercise conditions (PE: r = 0.354, p = 0.0006; WiPI: r = 0.350, p = 0.0007). A high participant adherence was achieved, and the acquisition of good quality CEUS video files was feasible. No adverse events occurred. Based on our novel examination protocol, CEUS seems to be feasible following higher-load resistance exercising and may be used as a new method for high-resolution perfusion quantification to investigate the effects of pre-exercise dietary supplementation on muscle perfusion and related muscle size dynamics.


  • Open Access

    Functional outcome and CEUS‐assessed deltoid muscle vitality after fracture‐specific versus standard prosthetic design in reverse shoulder arthroplasty for trauma

    by Julian Doll, Arndt Neide, Paul Mick, Ulf Brunnemer, Gerhard Schmidmaier, Christian Fischer

    Functional outcome after reverse‐shoulder‐arthroplasty (RSA) in proximal humerus fractures (PHF) depends on deltoid muscle integrity and successful reattachment of the tuberosities for best possible recovery of rotator‐cuff function. In this monocentric, prospective, randomized, controlled trial we investigated whether a reverse‐fracture‐prosthesis (RFP) with a metaphyseal fenestrated stem achieved superior shoulder and muscle function compared to a common reverse‐prosthesis (RP) design for patients with PHF. Our hypothesis was that patients with RFP may achieve a superior healing rate of the greater tuberosity (GT) compared to patients receiving RP, which translates to significantly higher clinical outcome and functional scores as well as differences in deltoid muscle microperfusion. Forty‐four patients with PHF were randomized preoperatively to one of the prosthesis types in RSA between 2018 and 2020 (22 with RFP and 22 with RP) and prospectively assessed 6 months after surgery. We assessed osteointegration of the GT with radiographs 1 day and 6 months postoperatively and examined shoulder function and patient satisfaction by using established shoulder scores. A contrast‐enhanced ultrasound (CEUS) examination of both shoulders was performed to quantify intramuscular blood flow and evaluate vitality of the deltoid muscle. None of the functional and psychosocial scores or radiographs and ultrasound examinations showed significant differences between the RSA designs. The constant‐Murley score (p = 0.384) and active anterior‐elevation‐abduction, and external rotation were comparable between the RFP and RP group. Similar healing rates of the GT were observed (p = 0.655). CEUS‐assessed deltoid microperfusion revealed equivalent muscle vitality for both groups (p = 0.312). Level of evidence: Level II; Randomized Controlled Trial; Treatment Study. Clinical significance: The radiographic evaluation for the investigation of the GT healing rate indicates that the proclaimed benefits of the fracture prosthesis with fenestration design might not be as great as expected.


  • Open Access

    CEUS‐assessed supraspinatus muscle perfusion improves after tendon repair and predicts anatomical and functional outcome: A 1‐year prospective pilot study

    by Paul Mick, Pierre Kunz, Christian Fischer, Sascha Gross, Julian Doll

    Rotator cuff tear including SSP (Supraspinatus) tendon tears are a very common and often painful condition with several therapeutic options such as tendon repair. Reflected by the high retear rates, the preoperative selection of patients suitable for surgery or conservative treatment, which often yields comparable results, remains difficult. Using contrast‐enhanced ultrasound (CEUS), it is possible to quantify the SSP muscle perfusion as a surrogate parameter for its vitality and healing capabilities. In this study, we enrolled 20 patients who underwent an SSP repair for a preoperative and two postoperative (6 months and 1 year) clinical and sonographic exams including CEUS. Along with functional improvement (p < 0.001, Constant score), we found a significant increase in CEUS‐assessed muscle perfusion after tendon repair (p < 0.001). Furthermore, weak preoperative muscle perfusion was associated with a higher risk of a retear (χ2 = 0.045) and a moderate trend toward lower postoperative shoulder function that did not reach significance (r = 0.435; p = 0.055, DASH score). If confirmed in larger studies, CEUS might be a valuable additional diagnostic method for a precise selection of patients who most likely profit from a tendon repair and those who can be treated conservatively with an equally good outcome.


  • Open Access

    Short‐term results of gait analysis with the Heidelberg foot measurement method and functional outcome after operative treatment of ankle fractures

    by Jessica C. Böpple, Michael Tanner, Sarah Campos, Christian Fischer, Sebastian Müller, Sebastian I. Wolf, Julian Doll

    Background: Ankle fractures are common fractures in trauma surgery. Several studies have compared gait patterns between affected patients and control groups. However, no one used the Heidelberg Foot Measurement Method in combination with statistical parametric mapping of the entire gait cycle in this patient cohort. We sought to identify possible mobility deficits in the tibio‐talar joint and medial arch in patients after ankle fractures as a sign of stiffness and pain that could result in a pathological gait pattern. We focused on the tibio‐talar flexion as it is the main movement in the tibio‐talar joint. Moreover, we examined the healing progress over time.Methods: Fourteen patients with isolated ankle fractures were included prospectively. A gait analysis using the Heidelberg Foot Measurement Method was performed 9 and 26 weeks after surgery to analyse the tibio‐talar dorsal flexion, the foot tibia dorsal flexion, the subtalar inversion and the medial arch as well as the cadence, the walking speed and the ground reaction force. The American Orthopedic Foot & Ankle Society ankle hindfoot score was used to obtain clinical data. Results were compared to those from 20 healthy participants. Furthermore, correlations between the American Orthopedic Foot & Ankle Society hindfoot score and the results of the gait analysis were evaluated.Results: Statistical parametric mapping showed significant differences for the Foot Tibia Dorsal Flexion for patients after 9 weeks (53–75%: p = 0.001) and patients after 26 weeks (58–70%: p = 0.011) compared to healthy participants, respectively. Furthermore, significant differences regarding the tibio‐talar dorsal flexion for patients 9 weeks after surgery (15–40%: p < 0.001; 56,5–70%: p = 0.007; 82–88%: p = 0.033; 97–98,5%: p = 0.048) as well as patients after 26 weeks (62,5–65%: p = 0.049) compared to healthy participants, respectively. There were no significant differences looking at the medial arch and the subtalar inversion. Moreover, significant differences regarding the ground reaction force were found for patients after 9 weeks (0–17%: p < 0.001; 21–37%: p < 0.001; 41–54%: p < 0.001; 60–64%: p = 0.013) as well as patients after 26 weeks (0–1,5%: p = 0.046; 5–15%: p < 0.001; 27–33%: p = 0.001; 45–49%: p = 0.005; 57–59%: p = 0.049) compared to healthy participants, respectively. In total, the range of motion in the tibio‐talar joint and the medial arch was reduced in affected patients compared to healthy participants. Patients showed significant increase of the range of motion between 9 and 26 weeks.Conclusions: This study shows, that patients affected by ankle fractures show limited mobility in the tibio‐talar joint and the medial arch when compared to healthy participants. Even though the limitation of motion remains at least over a period of 26 weeks, a significant increase can be recognized over time. Furthermore, if we look at the absolute values, the patients' values tend to get closer to those of the control group.Trial registration: This study is registered at the German Clinical Trials Register (DRKS00023379).


  • Open Access

    Contrast-enhanced ultrasound for determining muscular perfusion after oral intake of L-citrulline, L-arginine, and galloylated epicatechines

    by Julian Doll, Franziska Bürkle, Arndt Neide, Stefanos Tsitlakidis, Thomas Bruckner, Gerhard Schmidmaier, Christian Fischer

    Introduction: The market for dietary supplements in the sports sector has been growing rapidly for several years, though there is still lacking evidence regarding their claimed benefits. One group is that of nitric oxide increasing supplements, so-called “NO-boosters,” which are claimed to improve the supply of oxygen and nutrients to the muscle by enhancing vasodilation. The aim of this study was to investigate 3 of these supplements in healthy male athletes for their muscle perfusion-enhancing potential using contrast-enhanced ultrasound (CEUS). Methods: This placebo-controlled, double-blind, randomized cross-over trial will be carried out at the Center for Orthopedics, Trauma Surgery and Spinal Cord Injury of the University Hospital Heidelberg. Three commercial NO enhancing products including 300 mg of the specific green tea extract VASO6 and a combination of 8 g L-citrulline malate and 3 g L-arginine hydrochloride will be examined for their potential to increase muscular perfusion in 30-male athletes between 18 and 40 years and will be compared with a placebo. On each of the 3 appointments CEUS of the dominant biceps muscle will be performed at rest and after a standardized resistance training. Every athlete receives each of the 3 supplements once after a wash-out period of at least 1 week. Perfusion will be quantified via VueBox quantification software. The results of CEUS perfusion measurements will be compared intra- and interindividually and correlated with clinical parameters. Discussion: The results of this study may help to establish CEUS as a suitable imaging modality for the evaluation of potentially vasodilatory drugs in the field of sports. Other supplements could also be evaluated in this way to verify the content of their advertising claims. Trial registration: German Clinical Trials Register (DRKS), ID: DRKS00016972, registered on 25.03.2019.