Tzu-Chun Hung
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Tzu-Chun Hung has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Kuang-Hui Sun
Department of Biotechnology and Laboratory Science in Medicine, National Yang-Ming University, Taipei, Taiwan, ROC
2 shared publications Tien-Jen Liu
Department of Otolaryngology Head & Neck Surgery, MacKay Memorial Hospital, Taipei Branch, Taipei, Taiwan; School of Biomedical Engineering, Taipei Medical University, Taipei, Taiwan
2 shared publicationsBo-Nien Chen
Department of Otolaryngology Head & Neck Surgery, MacKay Memorial Hospital, Taipei Branch, Taipei, Taiwan
1 shared publicationChing-Lung Liu
Division of Chest, Department of Internal Medicine, MacKay Memorial Hospital, Taipei Branch, Taipei, Taiwan
1 shared publicationChristian Guilleminault
Division of Sleep Medicine, Stanford University, Redwood City, CA, USA
1 shared publicationChun-Chao Huang
Department of Radiology, MacKay Memorial Hospital, Taipei Branch, Taipei, Taiwan
1 shared publication
Latest Publications
- 1 August 2020
- Published by Elsevier in Sleep Medicine
- Vol. 72, 20-27
Building a model to precisely target the responders of a novel intermittent negative air pressure device-with mechanism definition
- 1 August 2020
- Published by Elsevier in Sleep Medicine
- Vol. 72, 20-27
Building a model to precisely target the responders of a novel intermittent negative air pressure device-with mechanism definition
- 28 January 2019
- Published by Springer Nature in Sleep and Breathing
- Vol. 23 (3) , 849-856
A novel intermittent negative air pressure device ameliorates obstructive sleep apnea syndrome in adults
Purpose Patients with obstructive sleep apnea syndrome (OSAS) have difficulties in compliance with continuous positive airway pressure (CPAP) and the treatment outcome is heterogeneous. We proposed a proof-of-concept study of a novel intermittent negative air pressure (iNAP®) device for physicians to apply on patients who have failed or refused to use CPAP. Methods The iNAP® device retains the tongue and the soft palate in a forward position to decrease airway obstruction. A full nightly usage with the device was evaluated with polysomnography. Subgrouping by baseline apnea–hypopnea index (AHI) and body mass index (BMI) with different treatment response criteria was applied to characterize the responder group of this novel device. Results Thirty-five patients were enrolled: age 41.9 ± 12.2 years (mean ± standard deviation), BMI 26.6 ± 4.3 kg/m2, AHI 41.4 ± 24.3 events/h, and oxygen desaturation index (ODI) 40.9 ± 24.4 events/h at baseline. AHI and ODI were significantly decreased (p < 0.001) by the device. Patients with moderate OSAS, with baseline AHI between 15 to 30 events/h, achieved 64% response rate; and non-obese patients, with BMI below 25 kg/m2, achieved 57% response rate, with response rate defined as 50% reduction in AHI from baseline and treated AHI lower than 20. There were minimal side effects reported. Conclusions In a proof-of-concept study, the device attained response to treatment as defined, in more than half of the moderate and non-obese OSAS patients, with minimal side effects.
- 28 January 2019
- Published by Springer Nature in Sleep and Breathing
- Vol. 23 (3) , 849-856
A novel intermittent negative air pressure device ameliorates obstructive sleep apnea syndrome in adults
Purpose Patients with obstructive sleep apnea syndrome (OSAS) have difficulties in compliance with continuous positive airway pressure (CPAP) and the treatment outcome is heterogeneous. We proposed a proof-of-concept study of a novel intermittent negative air pressure (iNAP®) device for physicians to apply on patients who have failed or refused to use CPAP. Methods The iNAP® device retains the tongue and the soft palate in a forward position to decrease airway obstruction. A full nightly usage with the device was evaluated with polysomnography. Subgrouping by baseline apnea–hypopnea index (AHI) and body mass index (BMI) with different treatment response criteria was applied to characterize the responder group of this novel device. Results Thirty-five patients were enrolled: age 41.9 ± 12.2 years (mean ± standard deviation), BMI 26.6 ± 4.3 kg/m2, AHI 41.4 ± 24.3 events/h, and oxygen desaturation index (ODI) 40.9 ± 24.4 events/h at baseline. AHI and ODI were significantly decreased (p < 0.001) by the device. Patients with moderate OSAS, with baseline AHI between 15 to 30 events/h, achieved 64% response rate; and non-obese patients, with BMI below 25 kg/m2, achieved 57% response rate, with response rate defined as 50% reduction in AHI from baseline and treated AHI lower than 20. There were minimal side effects reported. Conclusions In a proof-of-concept study, the device attained response to treatment as defined, in more than half of the moderate and non-obese OSAS patients, with minimal side effects.