Ning Kang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ning Kang has a total of 122 co-authors. Here are the top co-authors by number of shared publications:
Shenlei Zhou
Key Laboratory of High Power Laser and Physics, Shanghai Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, Shanghai 201800, China
9 shared publicationsAnle Lei
China Academy of Engineering Physics
7 shared publicationsHuiya Liu
Shanghai Institute of Optics and Fine Mechanics
7 shared publications- Huiya Liu
National Laboratory on High Power Laser and Physics, Shanghai Institute of Optics and Fine Mechanics, Chinese Academy of Science 1 , Shanghai 201800
7 shared publications Honghai An
China Academy of Engineering Physics
6 shared publications- Anle Lei
Shanghai Institute of Laser Plasma, China Academy of Engineering Physics 5 , Shanghai 201800
5 shared publications
Latest Publications
- Open Access
- 8 September 2026
- Published by IOP Publishing in Nuclear Fusion
- Vol. 66 (10) , 106033
Evidence for enhanced mass ablation rate driven by a broadband laser
For laser-driven inertial confinement fusion (ICF), implosion performance depends critically on the efficiency of laser energy coupling to mass ablation. Although recent experiments have confirmed that broadband lasers improve energy absorption efficiency by mitigating stimulated Brillouin scattering, evidence for a corresponding increase in mass ablation rate has remained absent. In this paper, we present the first experimental evidence that a broadband laser (0.6% fractional bandwidth) drives a higher mass ablation rate than a narrowband laser on planar titanium foils. Under matched laser intensity, the foil thickness that maximizes the Ti He‐ α x-ray yield—the optimal thickness—shifts from ∼10 μ m for the narrowband case to ∼15 μ m for the broadband case. Simulations relating optimal thickness to mass ablation rate show that this shift corresponds to an approximately (50 ± 26)% enhancement in mass ablation rate. Analysis suggests that, in addition to the improved laser absorption, the greater nonlocal thermal transport induced by the enhanced hot electron yield from broadband lasers may contribute to this ablation enhancement. These findings provide evidence that a broadband laser can markedly enhance mass ablation, supporting its use as a practical route toward better implosion performance in ICF.
- 8 September 2026
- Published by IOP Publishing in Nuclear Fusion
- Vol. 66 (10) , 106033
Open AccessEvidence for enhanced mass ablation rate driven by a broadband laser
For laser-driven inertial confinement fusion (ICF), implosion performance depends critically on the efficiency of laser energy coupling to mass ablation. Although recent experiments have confirmed that broadband lasers improve energy absorption efficiency by mitigating stimulated Brillouin scattering, evidence for a corresponding increase in mass ablation rate has remained absent. In this paper, we present the first experimental evidence that a broadband laser (0.6% fractional bandwidth) drives a higher mass ablation rate than a narrowband laser on planar titanium foils. Under matched laser intensity, the foil thickness that maximizes the Ti He‐ α x-ray yield—the optimal thickness—shifts from ∼10 μ m for the narrowband case to ∼15 μ m for the broadband case. Simulations relating optimal thickness to mass ablation rate show that this shift corresponds to an approximately (50 ± 26)% enhancement in mass ablation rate. Analysis suggests that, in addition to the improved laser absorption, the greater nonlocal thermal transport induced by the enhanced hot electron yield from broadband lasers may contribute to this ablation enhancement. These findings provide evidence that a broadband laser can markedly enhance mass ablation, supporting its use as a practical route toward better implosion performance in ICF.
- 1 January 2026
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 97 (1)
Comprehensive investigation on the plasma mirror temporal contrast enhancement instrument at SG-II 5PW laser facility
Laser-driven particle acceleration and related laser-matter interaction experiments require an ultrashort pulse laser with high temporal contrast. Here, we presented a plasma mirror (PM) temporal contrast enhancement system implemented at the SG-II 5PW laser facility, with a comprehensive investigation of spatiotemporal properties and physical applications. Key performance parameters of a PM were successfully obtained through single-shot online measurement by combining a spatiotemporally overlapped chirped pulse method. At a 45° incidence angle, the plasma reflectivity reached 84% for S-polarization and 48% for P-polarization, while the focal spot maintained excellent quality and the temporal contrast was improved by two orders of magnitude. The PM system was further applied in proton acceleration experiments under both polarization configurations. Supported by corresponding physical diagnostics, a significant reduction in optimum target thickness from 8 to 0.8 μm was achieved—clear evidence of effective pre-pulse suppression. Additionally, the PM and target installation were evaluated using a triple laser-damaged imaging method, based on the analysis of the three PM damage spots.
- 1 January 2026
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 97 (1)
Comprehensive investigation on the plasma mirror temporal contrast enhancement instrument at SG-II 5PW laser facility
Laser-driven particle acceleration and related laser-matter interaction experiments require an ultrashort pulse laser with high temporal contrast. Here, we presented a plasma mirror (PM) temporal contrast enhancement system implemented at the SG-II 5PW laser facility, with a comprehensive investigation of spatiotemporal properties and physical applications. Key performance parameters of a PM were successfully obtained through single-shot online measurement by combining a spatiotemporally overlapped chirped pulse method. At a 45° incidence angle, the plasma reflectivity reached 84% for S-polarization and 48% for P-polarization, while the focal spot maintained excellent quality and the temporal contrast was improved by two orders of magnitude. The PM system was further applied in proton acceleration experiments under both polarization configurations. Supported by corresponding physical diagnostics, a significant reduction in optimum target thickness from 8 to 0.8 μm was achieved—clear evidence of effective pre-pulse suppression. Additionally, the PM and target installation were evaluated using a triple laser-damaged imaging method, based on the analysis of the three PM damage spots.
- Open Access
- 30 January 2025
- Published by IOP Publishing in Plasma Physics and Controlled Fusion
- Vol. 67 (2) , 025033
Enhanced multi-keV x-ray emission with a low-coherence laser
Multi-keV x-rays are essential for diagnostic applications in inertial confinement fusion and high energy density physics. In this paper, enhancement of the multi-keV x-ray emission is achieved by using a low-coherence green laser to irradiate Ti foil targets at a fractional bandwidth of 0.6%. Compared to the widely used narrowband lasers, the above broadband laser generated 17%–23% more intense He-like alpha x-rays of Ti in the experiments at laser intensities of 4–6 × 1014 W cm-2. The improved laser absorption due to the reduction of stimulated Brillouin scattering introduced by the bandwidth is responsible for the enhancement of x-ray emission. The results suggest a promising application of broadband lasers on x-ray generations and further diagnostics.
- 30 January 2025
- Published by IOP Publishing in Plasma Physics and Controlled Fusion
- Vol. 67 (2) , 025033
Open AccessEnhanced multi-keV x-ray emission with a low-coherence laser
Multi-keV x-rays are essential for diagnostic applications in inertial confinement fusion and high energy density physics. In this paper, enhancement of the multi-keV x-ray emission is achieved by using a low-coherence green laser to irradiate Ti foil targets at a fractional bandwidth of 0.6%. Compared to the widely used narrowband lasers, the above broadband laser generated 17%–23% more intense He-like alpha x-rays of Ti in the experiments at laser intensities of 4–6 × 1014 W cm-2. The improved laser absorption due to the reduction of stimulated Brillouin scattering introduced by the bandwidth is responsible for the enhancement of x-ray emission. The results suggest a promising application of broadband lasers on x-ray generations and further diagnostics.
- Open Access
- 20 January 2025
- Published by IOP Publishing in Nuclear Fusion
- Vol. 65 (2) , 026042
Effects of moderate bandwidth on laser absorption and stimulated Raman sidescattering
We report experimental results regarding laser-plasma instabilities (LPI) developed by monochromatic and broadband green lasers with moderate bandwidths (0.2% and 0.6%) at intensities of 5–7 × 10 14 W cm−2 in the interest of inertial fusion energy. Angular-resolved distributions of scattered light were diagnosed, which demonstrated that the laser absorption rate is enhanced by increasing the laser bandwidth. This enhancement is primarily owing to the mitigation of stimulated Brillouin scattering. Meanwhile, the inherent temporal fluctuation of laser intensity caused by bandwidth results in more intense stimulated Raman scattering, particularly regarding the sidescattering. These findings indicate that the requirement of laser bandwidth used in inertial fusion energy should exceed the moderate level to achieve comprehensive mitigation of LPI.
- 20 January 2025
- Published by IOP Publishing in Nuclear Fusion
- Vol. 65 (2) , 026042
Open AccessEffects of moderate bandwidth on laser absorption and stimulated Raman sidescattering
We report experimental results regarding laser-plasma instabilities (LPI) developed by monochromatic and broadband green lasers with moderate bandwidths (0.2% and 0.6%) at intensities of 5–7 × 10 14 W cm−2 in the interest of inertial fusion energy. Angular-resolved distributions of scattered light were diagnosed, which demonstrated that the laser absorption rate is enhanced by increasing the laser bandwidth. This enhancement is primarily owing to the mitigation of stimulated Brillouin scattering. Meanwhile, the inherent temporal fluctuation of laser intensity caused by bandwidth results in more intense stimulated Raman scattering, particularly regarding the sidescattering. These findings indicate that the requirement of laser bandwidth used in inertial fusion energy should exceed the moderate level to achieve comprehensive mitigation of LPI.
- 12 December 2024
- Published by American Physical Society (APS) in Physical Review E
- Vol. 110 (6) , 065206
Mitigation of stimulated Brillouin scattering in inhomogeneous plasmas by broadband lasers
A theoretical model of stimulated Brillouin scattering (SBS) developed by a broadband laser in inhomogeneous plasmas is proposed and further investigated through a series of numerical simulations using the low-coherence laser model of the Kunwu facility. Polychromatic beamlets are coupled to develop a scattering mode, when all the poles of the beamlets are on the integration path of SBS dispersion relations. The coupled beamlets can be regarded as a monochromatic beam with the same incident energy, owing to their nearly identical amplification coefficients. Therefore, a broadband laser behaves as several decoupled beams with a frequency difference around the coupling threshold of the beamlets. In the direct-drive scheme, the overall saturation level of scattering light can be reduced by the broadband laser, if the bandwidth is larger than c_{s}/c∼10^{-3}, where c_{s} and c are the velocities of ion acoustic wave and light, respectively. Two-dimensional simulations demonstrate the robust mitigation of SBS by the low-coherence laser with a moderate bandwidth ∼0.6%, even in the ignition regime. The laser plasma parameters have a minor impact on the mitigation of SBS with broadband lasers. The speckle structures vary rapidly over time at the focal plane due to the introduction of the broadband, which results in the further reduction of SBS and filamentation compared with the monochromatic laser.
- 12 December 2024
- Published by American Physical Society (APS) in Physical Review E
- Vol. 110 (6) , 065206
Mitigation of stimulated Brillouin scattering in inhomogeneous plasmas by broadband lasers
A theoretical model of stimulated Brillouin scattering (SBS) developed by a broadband laser in inhomogeneous plasmas is proposed and further investigated through a series of numerical simulations using the low-coherence laser model of the Kunwu facility. Polychromatic beamlets are coupled to develop a scattering mode, when all the poles of the beamlets are on the integration path of SBS dispersion relations. The coupled beamlets can be regarded as a monochromatic beam with the same incident energy, owing to their nearly identical amplification coefficients. Therefore, a broadband laser behaves as several decoupled beams with a frequency difference around the coupling threshold of the beamlets. In the direct-drive scheme, the overall saturation level of scattering light can be reduced by the broadband laser, if the bandwidth is larger than c_{s}/c∼10^{-3}, where c_{s} and c are the velocities of ion acoustic wave and light, respectively. Two-dimensional simulations demonstrate the robust mitigation of SBS by the low-coherence laser with a moderate bandwidth ∼0.6%, even in the ignition regime. The laser plasma parameters have a minor impact on the mitigation of SBS with broadband lasers. The speckle structures vary rapidly over time at the focal plane due to the introduction of the broadband, which results in the further reduction of SBS and filamentation compared with the monochromatic laser.
- 18 January 2024
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 132 (3) , 035102
Reduction of Backward Scatterings at the Low-Coherence Kunwu Laser Facility
We report the first experimental observation on the reduction of backward scatterings by an instantaneous broadband laser with 0.6% bandwidth in conditions of interest for inertial confinement fusion at the low-coherence Kunwu laser facility. The backscatter of stimulated Brillouin scattering (SBS) was robustly reduced by half at intensities of with the broadband laser in comparison with the monochromatic laser. As SBS dominates energy loss of laser-plasma interactions, the reduction of that demonstrates the enhancement of laser-target coupling by the use of broadband laser. The mitigation of filamentation leads to the reduction of stimulated Raman backscattering at low intensities. In addition, the three-halves harmonic emission was reduced with the broadband laser as well.- 18 January 2024
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 132 (3) , 035102
Reduction of Backward Scatterings at the Low-Coherence Kunwu Laser Facility
We report the first experimental observation on the reduction of backward scatterings by an instantaneous broadband laser with 0.6% bandwidth in conditions of interest for inertial confinement fusion at the low-coherence Kunwu laser facility. The backscatter of stimulated Brillouin scattering (SBS) was robustly reduced by half at intensities of with the broadband laser in comparison with the monochromatic laser. As SBS dominates energy loss of laser-plasma interactions, the reduction of that demonstrates the enhancement of laser-target coupling by the use of broadband laser. The mitigation of filamentation leads to the reduction of stimulated Raman backscattering at low intensities. In addition, the three-halves harmonic emission was reduced with the broadband laser as well.- 1 January 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (1)
Mitigation of electromagnetic pulses interfering with Thomson parabola ion spectrometers at XG-III laser facility
The Thomson parabola ion spectrometer is vulnerable to intense electromagnetic pulses (EMPs) generated by a high-power laser interacting with solid targets. A metal shielding cage with a circular aperture of 1 mm diameter is designed to mitigate EMPs induced by a picosecond laser irradiating a copper target in an experiment where additionally an 8-ns delayed nanosecond laser is incident into an aluminum target at the XG-III laser facility. The implementation of the shielding cage reduces the maximum EMP amplitude inside the cage to 5.2 kV/m, and the simulation results indicate that the cage effectively shields electromagnetic waves. However, the laser-accelerated relativistic electrons which escaped the target potential accumulate charge on the surface of the cage, which is responsible for the detected EMPs within the cage. To further alleviate EMPs, a lead wall and an absorbing material (ECCOSORB AN-94) were added before the cage, significantly blocking the propagation of electrons. These findings provide valuable insights into EMP generation in large-scale laser infrastructures and serve as a foundation for electromagnetic shielding design.
- 1 January 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (1)
Mitigation of electromagnetic pulses interfering with Thomson parabola ion spectrometers at XG-III laser facility
The Thomson parabola ion spectrometer is vulnerable to intense electromagnetic pulses (EMPs) generated by a high-power laser interacting with solid targets. A metal shielding cage with a circular aperture of 1 mm diameter is designed to mitigate EMPs induced by a picosecond laser irradiating a copper target in an experiment where additionally an 8-ns delayed nanosecond laser is incident into an aluminum target at the XG-III laser facility. The implementation of the shielding cage reduces the maximum EMP amplitude inside the cage to 5.2 kV/m, and the simulation results indicate that the cage effectively shields electromagnetic waves. However, the laser-accelerated relativistic electrons which escaped the target potential accumulate charge on the surface of the cage, which is responsible for the detected EMPs within the cage. To further alleviate EMPs, a lead wall and an absorbing material (ECCOSORB AN-94) were added before the cage, significantly blocking the propagation of electrons. These findings provide valuable insights into EMP generation in large-scale laser infrastructures and serve as a foundation for electromagnetic shielding design.
- Open Access
- 1 December 2023
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 94 (12)
The generation of a fourth-harmonic probe and its application in Nomarski interferometry at Shengguang-II
In this work, a design for the generation of a 4ω (263-nm) probe converted from a 1ω (1053-nm) laser is presented. The design is based on a beta-barium borate and potassium dihydrogen phosphate two-step frequency-conversion process. A suitable configuration for Nomarski interferometry based on the 4ω probe is proposed, for measuring the electron density of laser-produced plasmas. The signal-to-noise ratio of the output 4ω probe to 1ω and 2ω light after frequency quadrupling and harmonic separation is 103 with a 0.5 GW/cm2 1ω input but decreases to ∼102 at intensities below 0.1 GW/cm2. Additional noise suppression by a factor of 104 is achieved using filters before the interferometer recording camera. The spatial resolution of the diagnostic can reach 5.2 µm for a 10% modulation transfer function. An experiment validating the probe diagnostic system is conducted at the Shengguang-II laser facility. A clear interferogram of an aluminum plasma is obtained with 0.1 GW/cm2 input, suggesting a maximal electron density of about 2.5 × 1020 cm−3 as retrieved through an inverse-Abel transform. The design proposed in this paper is appropriate for a small laser device or a large laser facility that lacks a separate diagnostic beam, and it is an inexpensive solution as it requires small-aperture 1ω input at a relatively low intensity. All the key parameters necessary to implement the design are provided in detail, making it straightforward to reproduce or transplant the system for specific uses.
- 1 December 2023
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 94 (12)
Open AccessThe generation of a fourth-harmonic probe and its application in Nomarski interferometry at Shengguang-II
In this work, a design for the generation of a 4ω (263-nm) probe converted from a 1ω (1053-nm) laser is presented. The design is based on a beta-barium borate and potassium dihydrogen phosphate two-step frequency-conversion process. A suitable configuration for Nomarski interferometry based on the 4ω probe is proposed, for measuring the electron density of laser-produced plasmas. The signal-to-noise ratio of the output 4ω probe to 1ω and 2ω light after frequency quadrupling and harmonic separation is 103 with a 0.5 GW/cm2 1ω input but decreases to ∼102 at intensities below 0.1 GW/cm2. Additional noise suppression by a factor of 104 is achieved using filters before the interferometer recording camera. The spatial resolution of the diagnostic can reach 5.2 µm for a 10% modulation transfer function. An experiment validating the probe diagnostic system is conducted at the Shengguang-II laser facility. A clear interferogram of an aluminum plasma is obtained with 0.1 GW/cm2 input, suggesting a maximal electron density of about 2.5 × 1020 cm−3 as retrieved through an inverse-Abel transform. The design proposed in this paper is appropriate for a small laser device or a large laser facility that lacks a separate diagnostic beam, and it is an inexpensive solution as it requires small-aperture 1ω input at a relatively low intensity. All the key parameters necessary to implement the design are provided in detail, making it straightforward to reproduce or transplant the system for specific uses.
- Open Access
- 9 February 2023
- Published by Cambridge University Press (CUP) in High Power Laser Science and Engineering
- Vol. 11, 1-9
A novel multi-shot target platform for laser-driven laboratory astrophysics experiments
A new approach to target development for laboratory astrophysics experiments at high-power laser facilities is presented. With the dawn of high-power lasers, laboratory astrophysics has emerged as a field, bringing insight into physical processes in astrophysical objects, such as the formation of stars. An important factor for success in these experiments is targetry. To date, targets have mainly relied on expensive and challenging microfabrication methods. The design presented incorporates replaceable machined parts that assemble into a structure that defines the experimental geometry. This can make targets cheaper and faster to manufacture, while maintaining robustness and reproducibility. The platform is intended for experiments on plasma flows, but it is flexible and may be adapted to the constraints of other experimental setups. Examples of targets used in experimental campaigns are shown, including a design for insertion in a high magnetic field coil. Experimental results are included, demonstrating the performance of the targets.
- 9 February 2023
- Published by Cambridge University Press (CUP) in High Power Laser Science and Engineering
- Vol. 11, 1-9
Open AccessA novel multi-shot target platform for laser-driven laboratory astrophysics experiments
A new approach to target development for laboratory astrophysics experiments at high-power laser facilities is presented. With the dawn of high-power lasers, laboratory astrophysics has emerged as a field, bringing insight into physical processes in astrophysical objects, such as the formation of stars. An important factor for success in these experiments is targetry. To date, targets have mainly relied on expensive and challenging microfabrication methods. The design presented incorporates replaceable machined parts that assemble into a structure that defines the experimental geometry. This can make targets cheaper and faster to manufacture, while maintaining robustness and reproducibility. The platform is intended for experiments on plasma flows, but it is flexible and may be adapted to the constraints of other experimental setups. Examples of targets used in experimental campaigns are shown, including a design for insertion in a high magnetic field coil. Experimental results are included, demonstrating the performance of the targets.
- 9 November 2021
- Published by Optica Publishing Group in Journal of the Optical Society of America B
- Vol. 38 (12) , 3567-3574
Inhibition of stimulated Raman side-scattering with one-dimensional smoothing by spectral dispersion
Smoothing by spectral dispersion (SSD) is a beam smoothing technology aiming at improving irradiance uniformity in laser inertial confinement fusion, which has the potential to suppress many kinds of laser–plasma instabilities. Different effectivenesses of SSD on the suppression of instabilities were reported in previous works, suggesting SSD has different effects on different instabilities under various laser and plasma conditions. In this paper, inhibition of stimulated Raman side-scattering, deduced from the decrease in side-scattered light and hot electrons, in plastic plasmas at moderate laser intensity is observed in experiments with the application of one-dimensional SSD, the reason for which is deduced to be related to the suppression of filamentation. In contrast, two-plasmon decay and backward Raman scattering were not effectively suppressed by SSD in the experiments, the reason for which could be attributed to the limited modulation frequency and the directions of growth with respect to SSD induced rapid motion of laser spots.
- 9 November 2021
- Published by Optica Publishing Group in Journal of the Optical Society of America B
- Vol. 38 (12) , 3567-3574
Inhibition of stimulated Raman side-scattering with one-dimensional smoothing by spectral dispersion
Smoothing by spectral dispersion (SSD) is a beam smoothing technology aiming at improving irradiance uniformity in laser inertial confinement fusion, which has the potential to suppress many kinds of laser–plasma instabilities. Different effectivenesses of SSD on the suppression of instabilities were reported in previous works, suggesting SSD has different effects on different instabilities under various laser and plasma conditions. In this paper, inhibition of stimulated Raman side-scattering, deduced from the decrease in side-scattered light and hot electrons, in plastic plasmas at moderate laser intensity is observed in experiments with the application of one-dimensional SSD, the reason for which is deduced to be related to the suppression of filamentation. In contrast, two-plasmon decay and backward Raman scattering were not effectively suppressed by SSD in the experiments, the reason for which could be attributed to the limited modulation frequency and the directions of growth with respect to SSD induced rapid motion of laser spots.