Ali Emre Kavur
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Ali Emre Kavur has a total of 117 co-authors. Here are the top co-authors by number of shared publications:
- Mustafa Alper Selver
Department of Electrical and Electronics Engineering, Dokuz Eylul University, Izmir, Turkey
7 shared publications - Annette Kopp-Schneider
Division of Biostatistics German Cancer Research Center (DKFZ) Heidelberg Germany
2 shared publications - Annika Reinke
German Cancer Research Center (DKFZ)
2 shared publications - Bora Baydar
Electrical and Electronics Engineering Department, Middle East Technical University, Ankara, Trkiye
2 shared publications Fabian Isensee
German Cancer Research Center (DKFZ) Heidelberg, Division of Medical Image Computing, Heidelberg, Germany
2 shared publications- Gozde Bozdagi Akar
Department of Electrical and Electronics Engineering, Middle East Technical University, Ankara, Turkey
2 shared publications
Latest Publications
- 8 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Emerging Topics in Computational Intelligence
- Vol. 8 (4) , 2723-2735
Cross-Modal Learning via Adversarial Loss and Covariate Shift for Enhanced Liver Segmentation
Despite the widespread use of deep learning methods for semantic segmentation from single imaging modalities, their performance for exploiting multi-domain data still needs to improve. However, the decision-making process in radiology is often guided by data from multiple sources, such as pre-operative evaluation of living donated liver transplantation donors. In such cases, cross-modality performances of deep models become more important. Unfortunately, the domain-dependency of existing techniques limits their clinical acceptability, primarily confining their performance to individual domains. This issue is further formulated as a multi-source domain adaptation problem, which is an emerging field mainly due to the diverse pattern characteristics exhibited from cross-modality data. This paper presents a novel method that can learn robust representations from unpaired cross-modal (CT-MR) data by encapsulating distinct and shared patterns from multiple modalities. In our solution, the covariate shift property is maintained with structural modifications in our architecture. Also, an adversarial loss is adopted to boost the representation capacity. As a result, sparse and rich representations are obtained. Another superiority of our model is that no information about modalities is needed at the training or inference phase. Tests on unpaired CT and MR liver data obtained from the cross-modality task of the CHAOS grand challenge demonstrate that our approach achieves state-of-the-art results with a large margin in both individual metrics and overall scores.
- 8 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Emerging Topics in Computational Intelligence
- Vol. 8 (4) , 2723-2735
Cross-Modal Learning via Adversarial Loss and Covariate Shift for Enhanced Liver Segmentation
Despite the widespread use of deep learning methods for semantic segmentation from single imaging modalities, their performance for exploiting multi-domain data still needs to improve. However, the decision-making process in radiology is often guided by data from multiple sources, such as pre-operative evaluation of living donated liver transplantation donors. In such cases, cross-modality performances of deep models become more important. Unfortunately, the domain-dependency of existing techniques limits their clinical acceptability, primarily confining their performance to individual domains. This issue is further formulated as a multi-source domain adaptation problem, which is an emerging field mainly due to the diverse pattern characteristics exhibited from cross-modality data. This paper presents a novel method that can learn robust representations from unpaired cross-modal (CT-MR) data by encapsulating distinct and shared patterns from multiple modalities. In our solution, the covariate shift property is maintained with structural modifications in our architecture. Also, an adversarial loss is adopted to boost the representation capacity. As a result, sparse and rich representations are obtained. Another superiority of our model is that no information about modalities is needed at the training or inference phase. Tests on unpaired CT and MR liver data obtained from the cross-modality task of the CHAOS grand challenge demonstrate that our approach achieves state-of-the-art results with a large margin in both individual metrics and overall scores.
- Top Cited PapersOpen Access
- 12 February 2024
- Published by Springer Nature in Nature Methods
- Vol. 21 (2) , 182-194
Understanding metric-related pitfalls in image analysis validation
Validation metrics are key for tracking scientific progress and bridging the current chasm between artificial intelligence research and its translation into practice. However, increasing evidence shows that, particularly in image analysis, metrics are often chosen inadequately. Although taking into account the individual strengths, weaknesses and limitations of validation metrics is a critical prerequisite to making educated choices, the relevant knowledge is currently scattered and poorly accessible to individual researchers. Based on a multistage Delphi process conducted by a multidisciplinary expert consortium as well as extensive community feedback, the present work provides a reliable and comprehensive common point of access to information on pitfalls related to validation metrics in image analysis. Although focused on biomedical image analysis, the addressed pitfalls generalize across application domains and are categorized according to a newly created, domain-agnostic taxonomy. The work serves to enhance global comprehension of a key topic in image analysis validation.
- 12 February 2024
- Published by Springer Nature in Nature Methods
- Vol. 21 (2) , 182-194
Top Cited PapersOpen AccessUnderstanding metric-related pitfalls in image analysis validation
Validation metrics are key for tracking scientific progress and bridging the current chasm between artificial intelligence research and its translation into practice. However, increasing evidence shows that, particularly in image analysis, metrics are often chosen inadequately. Although taking into account the individual strengths, weaknesses and limitations of validation metrics is a critical prerequisite to making educated choices, the relevant knowledge is currently scattered and poorly accessible to individual researchers. Based on a multistage Delphi process conducted by a multidisciplinary expert consortium as well as extensive community feedback, the present work provides a reliable and comprehensive common point of access to information on pitfalls related to validation metrics in image analysis. Although focused on biomedical image analysis, the addressed pitfalls generalize across application domains and are categorized according to a newly created, domain-agnostic taxonomy. The work serves to enhance global comprehension of a key topic in image analysis validation.
- Top Cited PapersOpen Access
- 2 March 2023
- Published by Springer Nature in Nature Machine Intelligence
- Vol. 5 (3) , 273-283
Labelling instructions matter in biomedical image analysis
Biomedical image analysis algorithm validation depends on high-quality annotation of reference datasets, for which labelling instructions are key. Despite their importance, their optimization remains largely unexplored. Here we present a systematic study of labelling instructions and their impact on annotation quality in the field. Through comprehensive examination of professional practice and international competitions registered at the Medical Image Computing and Computer Assisted Intervention Society, the largest international society in the biomedical imaging field, we uncovered a discrepancy between annotators’ needs for labelling instructions and their current quality and availability. On the basis of an analysis of 14,040 images annotated by 156 annotators from four professional annotation companies and 708 Amazon Mechanical Turk crowdworkers using instructions with different information density levels, we further found that including exemplary images substantially boosts annotation performance compared with text-only descriptions, while solely extending text descriptions does not. Finally, professional annotators constantly outperform Amazon Mechanical Turk crowdworkers. Our study raises awareness for the need of quality standards in biomedical image analysis labelling instructions.
- 2 March 2023
- Published by Springer Nature in Nature Machine Intelligence
- Vol. 5 (3) , 273-283
Top Cited PapersOpen AccessLabelling instructions matter in biomedical image analysis
Biomedical image analysis algorithm validation depends on high-quality annotation of reference datasets, for which labelling instructions are key. Despite their importance, their optimization remains largely unexplored. Here we present a systematic study of labelling instructions and their impact on annotation quality in the field. Through comprehensive examination of professional practice and international competitions registered at the Medical Image Computing and Computer Assisted Intervention Society, the largest international society in the biomedical imaging field, we uncovered a discrepancy between annotators’ needs for labelling instructions and their current quality and availability. On the basis of an analysis of 14,040 images annotated by 156 annotators from four professional annotation companies and 708 Amazon Mechanical Turk crowdworkers using instructions with different information density levels, we further found that including exemplary images substantially boosts annotation performance compared with text-only descriptions, while solely extending text descriptions does not. Finally, professional annotators constantly outperform Amazon Mechanical Turk crowdworkers. Our study raises awareness for the need of quality standards in biomedical image analysis labelling instructions.
- Open Access
CHAOS Challenge -- Combined (CT-MR) Healthy Abdominal Organ Segmentation
Segmentation of abdominal organs has been a comprehensive, yet unresolved, research field for many years. In the last decade, intensive developments in deep learning (DL) have introduced new state-of-the-art segmentation systems. In order to expand the knowledge on these topics, the CHAOS - Combined (CT-MR) Healthy Abdominal Organ Segmentation challenge has been organized in conjunction with IEEE International Symposium on Biomedical Imaging (ISBI), 2019, in Venice, Italy. CHAOS provides both abdominal CT and MR data from healthy subjects for single and multiple abdominal organ segmentation. Five different but complementary tasks have been designed to analyze the capabilities of current approaches from multiple perspectives. The results are investigated thoroughly, compared with manual annotations and interactive methods. The analysis shows that the performance of DL models for single modality (CT / MR) can show reliable volumetric analysis performance (DICE: 0.98 $\pm$ 0.00 / 0.95 $\pm$ 0.01) but the best MSSD performance remain limited (21.89 $\pm$ 13.94 / 20.85 $\pm$ 10.63 mm). The performances of participating models decrease significantly for cross-modality tasks for the liver (DICE: 0.88 $\pm$ 0.15 MSSD: 36.33 $\pm$ 21.97 mm) and all organs (DICE: 0.85 $\pm$ 0.21 MSSD: 33.17 $\pm$ 38.93 mm). Despite contrary examples on different applications, multi-tasking DL models designed to segment all organs seem to perform worse compared to organ-specific ones (performance drop around 5\%). Besides, such directions of further research for cross-modality segmentation would significantly support real-world clinical applications. Moreover, having more than 1500 participants, another important contribution of the paper is the analysis on shortcomings of challenge organizations such as the effects of multiple submissions and peeking phenomena.Open AccessCHAOS Challenge -- Combined (CT-MR) Healthy Abdominal Organ Segmentation
Segmentation of abdominal organs has been a comprehensive, yet unresolved, research field for many years. In the last decade, intensive developments in deep learning (DL) have introduced new state-of-the-art segmentation systems. In order to expand the knowledge on these topics, the CHAOS - Combined (CT-MR) Healthy Abdominal Organ Segmentation challenge has been organized in conjunction with IEEE International Symposium on Biomedical Imaging (ISBI), 2019, in Venice, Italy. CHAOS provides both abdominal CT and MR data from healthy subjects for single and multiple abdominal organ segmentation. Five different but complementary tasks have been designed to analyze the capabilities of current approaches from multiple perspectives. The results are investigated thoroughly, compared with manual annotations and interactive methods. The analysis shows that the performance of DL models for single modality (CT / MR) can show reliable volumetric analysis performance (DICE: 0.98 $\pm$ 0.00 / 0.95 $\pm$ 0.01) but the best MSSD performance remain limited (21.89 $\pm$ 13.94 / 20.85 $\pm$ 10.63 mm). The performances of participating models decrease significantly for cross-modality tasks for the liver (DICE: 0.88 $\pm$ 0.15 MSSD: 36.33 $\pm$ 21.97 mm) and all organs (DICE: 0.85 $\pm$ 0.21 MSSD: 33.17 $\pm$ 38.93 mm). Despite contrary examples on different applications, multi-tasking DL models designed to segment all organs seem to perform worse compared to organ-specific ones (performance drop around 5\%). Besides, such directions of further research for cross-modality segmentation would significantly support real-world clinical applications. Moreover, having more than 1500 participants, another important contribution of the paper is the analysis on shortcomings of challenge organizations such as the effects of multiple submissions and peeking phenomena. - 28 January 2020
- Published by Wiley in Medical Physics
- Vol. 47 (4) , 1727-1737
Reversible 3D compression of segmented medical volumes: usability analysis for teleradiology and storage
Background: DICOM standard does not have modules that provide the possibilities of two‐dimensional Presentation States to three‐dimensional (3D). Once the final 3D rendering is obtained, only video/image exporting or snapshots can be used. To increase the utility of 3D Presentation States in clinical practice and teleradiology, the storing and transferring the segmentation results, obtained after tedious procedures, can be very effective.Purpose: To propose a strategy for preserving interaction and mobility of visualizations for teleradiology by storing and transferring only binary segmented data, which is effectively compressed by modern adaptive and context‐based reversible methods.Material and Methods: A diverse set of segmented data, which include four abdominal organs (liver, spleen, right, and left kidneys) from 20 T1‐DUAL and 20 T2‐SPIR MRI, liver from 20 CT, and abdominal aorta with aneurysms (AAA) from 19 computed tomography‐angiography datasets, are collected. Each organ is segmented manually by expert physicians, and binary volumes are created. The well‐established reversible binary compression methods PNG, JPEG‐LS, JPEG‐XR, CCITT‐G4, LZW, JBIG2, and ZIP are applied to medical datasets. Recently proposed context‐based (3D‐RLE) and adaptive (ABIC) algorithms are also employed. The performance assessment has been presented in terms of the compression ratio that is a universal compression metric.Results: Reversible compression of binary volumes results with substantial decreases in file size such as 254 to 2.14 MB for CT‐AAA, 56.7 to 0.3 MB for CT‐liver. Moreover, compared to the performance of well‐established methods (i.e., mean 76.14%), CR is observed to be increased significantly for all segmented organs from both CT and MRI datasets when ABIC (95.49%) and 3D‐RLE (94.98%) are utilized. The hypothesis is that morphological coherence of scanning procedure and adaptation between the segmented organs, that is, bi‐level images, contributes to compression performance. Although the performance of well‐established techniques is satisfactory, the sensitivity of ABIC to modality type and the advantage of 3D‐RLE when the spatial coherence between the adjacent slices are high results with up to 10 times more CR performance.Conclusion: Adaptive and context‐based compression strategies allow effective storage and transfer of segmented binary data, which can be used to re‐produce visualizations for better teleradiology practices preserving all interaction mechanisms.
- 28 January 2020
- Published by Wiley in Medical Physics
- Vol. 47 (4) , 1727-1737
Reversible 3D compression of segmented medical volumes: usability analysis for teleradiology and storage
Background: DICOM standard does not have modules that provide the possibilities of two‐dimensional Presentation States to three‐dimensional (3D). Once the final 3D rendering is obtained, only video/image exporting or snapshots can be used. To increase the utility of 3D Presentation States in clinical practice and teleradiology, the storing and transferring the segmentation results, obtained after tedious procedures, can be very effective.Purpose: To propose a strategy for preserving interaction and mobility of visualizations for teleradiology by storing and transferring only binary segmented data, which is effectively compressed by modern adaptive and context‐based reversible methods.Material and Methods: A diverse set of segmented data, which include four abdominal organs (liver, spleen, right, and left kidneys) from 20 T1‐DUAL and 20 T2‐SPIR MRI, liver from 20 CT, and abdominal aorta with aneurysms (AAA) from 19 computed tomography‐angiography datasets, are collected. Each organ is segmented manually by expert physicians, and binary volumes are created. The well‐established reversible binary compression methods PNG, JPEG‐LS, JPEG‐XR, CCITT‐G4, LZW, JBIG2, and ZIP are applied to medical datasets. Recently proposed context‐based (3D‐RLE) and adaptive (ABIC) algorithms are also employed. The performance assessment has been presented in terms of the compression ratio that is a universal compression metric.Results: Reversible compression of binary volumes results with substantial decreases in file size such as 254 to 2.14 MB for CT‐AAA, 56.7 to 0.3 MB for CT‐liver. Moreover, compared to the performance of well‐established methods (i.e., mean 76.14%), CR is observed to be increased significantly for all segmented organs from both CT and MRI datasets when ABIC (95.49%) and 3D‐RLE (94.98%) are utilized. The hypothesis is that morphological coherence of scanning procedure and adaptation between the segmented organs, that is, bi‐level images, contributes to compression performance. Although the performance of well‐established techniques is satisfactory, the sensitivity of ABIC to modality type and the advantage of 3D‐RLE when the spatial coherence between the adjacent slices are high results with up to 10 times more CR performance.Conclusion: Adaptive and context‐based compression strategies allow effective storage and transfer of segmented binary data, which can be used to re‐produce visualizations for better teleradiology practices preserving all interaction mechanisms.
- Open Access
Basic Ensembles of Vanilla-Style Deep Learning Models Improve Liver Segmentation From CT Images
Segmentation of the liver from 3D computer tomography (CT) images is one of the most frequently performed operations in medical image analysis. In the past decade, Deep Learning Models (DMs) have offered significant improvements over previous methods for liver segmentation. The success of DMs is usually owed to the user's expertise in deep learning as well as to intricate training procedures. The need for bespoke expertise limits the reproducibility of empirical studies involving DMs. Today's consensus is that an ensemble of DMs works better than the individual component DMs. In this study we set off to explore the potential of ensembles of publicly available, `vanilla-style' DM segmenters Our ensembles were created from four off-the-shelf DMs: U-Net, Deepmedic, V-Net, and Dense V-Networks. To prevent further overfitting and to keep the overall model simple, we use basic non-trainable ensemble combiners: majority vote, average, product and min/max. Our results with two publicly available data sets (CHAOS and 3Dircadb1) demonstrate that ensembles are significantly better than the individual segmenters on four widely used metrics.
Open AccessBasic Ensembles of Vanilla-Style Deep Learning Models Improve Liver Segmentation From CT Images
Segmentation of the liver from 3D computer tomography (CT) images is one of the most frequently performed operations in medical image analysis. In the past decade, Deep Learning Models (DMs) have offered significant improvements over previous methods for liver segmentation. The success of DMs is usually owed to the user's expertise in deep learning as well as to intricate training procedures. The need for bespoke expertise limits the reproducibility of empirical studies involving DMs. Today's consensus is that an ensemble of DMs works better than the individual component DMs. In this study we set off to explore the potential of ensembles of publicly available, `vanilla-style' DM segmenters Our ensembles were created from four off-the-shelf DMs: U-Net, Deepmedic, V-Net, and Dense V-Networks. To prevent further overfitting and to keep the overall model simple, we use basic non-trainable ensemble combiners: majority vote, average, product and min/max. Our results with two publicly available data sets (CHAOS and 3Dircadb1) demonstrate that ensembles are significantly better than the individual segmenters on four widely used metrics.
- 2 January 2020
- Published by Galenos Yayinevi in Diagnostic and Interventional Radiology
- Vol. 26 (1) , 11-21
Comparison of semi-automatic and deep learning-based automatic methods for liver segmentation in living liver transplant donors
To compare the accuracy and repeatability of emerging machine learning based (i.e. deep) automatic segmentation algorithms with those of well-established semi-automatic (interactive) methods for determining liver volume in living liver transplant donors at computerized tomography (CT) imaging. A total of 12 (6 semi-, 6 full-automatic) methods are evaluated. The semi-automatic segmentation algorithms are based on both traditional iterative models including watershed, fast marching, region growing, active contours and modern techniques including robust statistical segmenter and super-pixels. These methods entail some sort of interaction mechanism such as placing initialization seeds on images or determining a parameter range. The automatic methods are based on deep learning and they include three framework templates (DeepMedic, NiftyNet and U-Net) the first two of which are applied with default parameter sets and the last two involve adapted novel model designs. For 20 living donors (6 training and 12 test datasets), a group of imaging scientists and radiologists created ground truths by performing manual segmentations on contrast material-enhanced CT images. Each segmentation is evaluated using five metrics (i.e. volume overlap and relative volume errors, average/RMS/maximum symmetrical surface distances). The results are mapped to a scoring system and a final grade is calculated by taking their average. Accuracy and repeatability were evaluated using slice by slice comparisons and volumetric analysis. Diversity and complementarity are observed through heatmaps. Majority voting and Simultaneous Truth and Performance Level Estimation (STAPLE) algorithms are utilized to obtain the fusion of the individual results. The top four methods are determined to be automatic deep models having 79.63, 79.46 and 77.15 and 74.50 scores. Intra-user score is determined as 95.14. Overall, deep automatic segmentation outperformed interactive techniques on all metrics. The mean volume of liver of ground truth is found to be 1409.93 mL ± 271.28 mL, while it is calculated as 1342.21 mL ± 231.24 mL using automatic and 1201.26 mL ± 258.13 mL using interactive methods, showing higher accuracy and less variation on behalf of automatic methods. The qualitative analysis of segmentation results showed significant diversity and complementarity enabling the idea of using ensembles to obtain superior results. The fusion of automatic methods reached 83.87 with majority voting and 86.20 using STAPLE that are only slightly less than fusion of all methods that achieved 86.70 (majority voting) and 88.74 (STAPLE). Use of the new deep learning based automatic segmentation algorithms substantially increases the accuracy and repeatability for segmentation and volumetric measurements of liver. Fusion of automatic methods based on ensemble approaches exhibits best results almost without any additional time cost due to potential parallel execution of multiple models.
- 2 January 2020
- Published by Galenos Yayinevi in Diagnostic and Interventional Radiology
- Vol. 26 (1) , 11-21
Comparison of semi-automatic and deep learning-based automatic methods for liver segmentation in living liver transplant donors
To compare the accuracy and repeatability of emerging machine learning based (i.e. deep) automatic segmentation algorithms with those of well-established semi-automatic (interactive) methods for determining liver volume in living liver transplant donors at computerized tomography (CT) imaging. A total of 12 (6 semi-, 6 full-automatic) methods are evaluated. The semi-automatic segmentation algorithms are based on both traditional iterative models including watershed, fast marching, region growing, active contours and modern techniques including robust statistical segmenter and super-pixels. These methods entail some sort of interaction mechanism such as placing initialization seeds on images or determining a parameter range. The automatic methods are based on deep learning and they include three framework templates (DeepMedic, NiftyNet and U-Net) the first two of which are applied with default parameter sets and the last two involve adapted novel model designs. For 20 living donors (6 training and 12 test datasets), a group of imaging scientists and radiologists created ground truths by performing manual segmentations on contrast material-enhanced CT images. Each segmentation is evaluated using five metrics (i.e. volume overlap and relative volume errors, average/RMS/maximum symmetrical surface distances). The results are mapped to a scoring system and a final grade is calculated by taking their average. Accuracy and repeatability were evaluated using slice by slice comparisons and volumetric analysis. Diversity and complementarity are observed through heatmaps. Majority voting and Simultaneous Truth and Performance Level Estimation (STAPLE) algorithms are utilized to obtain the fusion of the individual results. The top four methods are determined to be automatic deep models having 79.63, 79.46 and 77.15 and 74.50 scores. Intra-user score is determined as 95.14. Overall, deep automatic segmentation outperformed interactive techniques on all metrics. The mean volume of liver of ground truth is found to be 1409.93 mL ± 271.28 mL, while it is calculated as 1342.21 mL ± 231.24 mL using automatic and 1201.26 mL ± 258.13 mL using interactive methods, showing higher accuracy and less variation on behalf of automatic methods. The qualitative analysis of segmentation results showed significant diversity and complementarity enabling the idea of using ensembles to obtain superior results. The fusion of automatic methods reached 83.87 with majority voting and 86.20 using STAPLE that are only slightly less than fusion of all methods that achieved 86.70 (majority voting) and 88.74 (STAPLE). Use of the new deep learning based automatic segmentation algorithms substantially increases the accuracy and repeatability for segmentation and volumetric measurements of liver. Fusion of automatic methods based on ensemble approaches exhibits best results almost without any additional time cost due to potential parallel execution of multiple models.
- 14 November 2015
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 11 (5) , 803-816
Implementation and use of 3D pairwise geodesic distance fields for seeding abdominal aortic vessels
Precise extraction of aorta and the vessels departing from it (i.e. coeliac, renal, and iliac) is vital for correct positioning of a graft prior to abdominal aortic surgery. To perform this task, most of the segmentation algorithms rely on seed points, and better-located seed points provide better initial positions for cross-sectional methods. Under non-optimal acquisition characteristics of daily clinical routine and complex morphology of these vessels, inserting seed points to all these small, but critically important vessels is a tedious, time-consuming, and error-prone task. Thus, in this paper, a novel strategy is developed to generate pathways between user-inserted seed points in order to initialize segmentation methods effectively. The proposed method requires only a single user-inserted seed for each vessel of interest for initializations. Starting from these initial seeds, it automatically generates pathways that span all vessels in between. To accomplish this, first, a geodesic mask is generated by adaptive thresholding, which reinforces the initial seeds to be kept in the vascular tree. Then, a novel implementation of 3D pairwise geodesic distance field (3D-PGDF) is utilized. It is shown that the minimal-valued geodesic of 3D-PGDF successfully defines a path linking the initial seeds as being the shortest geodesic. Moreover, the robustness of the minimum level set of the 3D-PGDF to local variations and regions of high curvature is increased by a region classification strategy, which adds partial geodesics to these critical regions. The proposed method was applied to 19 challenging CT data sets obtained from four different scanners and compared to two benchmark methods. The first method is a high-precision technique with very long processing time (subvoxel precise multi-stencil fast marching—MSFM), while the second is a very fast method with lower accuracy (3D fast marching). The results, which are obtained using various measures, show that the pathways generated by the developed technique enable significantly higher segmentation performance than 3D fast marching and require much less computational power and time than MSFM. The developed technique offers a useful tool for generating pathways between seed points with minimal user interaction. It guarantees to include all important vessels in a computationally effective manner and thus, it can be used to initialize segmentation methods for abdominal aortic tree.
- 14 November 2015
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 11 (5) , 803-816
Implementation and use of 3D pairwise geodesic distance fields for seeding abdominal aortic vessels
Precise extraction of aorta and the vessels departing from it (i.e. coeliac, renal, and iliac) is vital for correct positioning of a graft prior to abdominal aortic surgery. To perform this task, most of the segmentation algorithms rely on seed points, and better-located seed points provide better initial positions for cross-sectional methods. Under non-optimal acquisition characteristics of daily clinical routine and complex morphology of these vessels, inserting seed points to all these small, but critically important vessels is a tedious, time-consuming, and error-prone task. Thus, in this paper, a novel strategy is developed to generate pathways between user-inserted seed points in order to initialize segmentation methods effectively. The proposed method requires only a single user-inserted seed for each vessel of interest for initializations. Starting from these initial seeds, it automatically generates pathways that span all vessels in between. To accomplish this, first, a geodesic mask is generated by adaptive thresholding, which reinforces the initial seeds to be kept in the vascular tree. Then, a novel implementation of 3D pairwise geodesic distance field (3D-PGDF) is utilized. It is shown that the minimal-valued geodesic of 3D-PGDF successfully defines a path linking the initial seeds as being the shortest geodesic. Moreover, the robustness of the minimum level set of the 3D-PGDF to local variations and regions of high curvature is increased by a region classification strategy, which adds partial geodesics to these critical regions. The proposed method was applied to 19 challenging CT data sets obtained from four different scanners and compared to two benchmark methods. The first method is a high-precision technique with very long processing time (subvoxel precise multi-stencil fast marching—MSFM), while the second is a very fast method with lower accuracy (3D fast marching). The results, which are obtained using various measures, show that the pathways generated by the developed technique enable significantly higher segmentation performance than 3D fast marching and require much less computational power and time than MSFM. The developed technique offers a useful tool for generating pathways between seed points with minimal user interaction. It guarantees to include all important vessels in a computationally effective manner and thus, it can be used to initialize segmentation methods for abdominal aortic tree.
- 30 September 2015
- Published by Journal of the Faculty of Engineering and Architecture of Gazi University in Gazi Üniversitesi Mühendislik-Mimarlık Fakültesi Dergisi
- Vol. 30 (3)
BATIN BÖLGESİ ORGANLARININ MR GÖRÜNTÜLERİNDEN ÇOK AŞAMALI HİYERARŞİK SINIFLAMA İLE BÖLÜTLENMESİ
Tıbbi görüntüleme ile anatomi hakkında ayrıntılı bilgi elde edinilebildiğinden, tanı amaçlı görüntüleme günümüzde birçok açıdan önem kazanmıştır. Görüntüleme cihazları tarafından sunulan verilerin fazlalığı ve çeşitliliği nedeniyle, tüm veri yerine görüntülerde sadece ilgilenilen dokunun belirlenerek ayrılması (Bölütlenmesi) sağlanabilir. Elcil yöntemler ile bölütleme yorucu, zaman alıcı ve deneyim gerektiren bir işlem olduğundan, otomatik yordamlara gereksinim duyulmaktadır. Geliştirilen yordamların klinik koşullarında kullanılabilmesi içinse yüksek başarıma sahip sonuçlar üretmeleri gerekmektedir. Manyetik Rezonans (MR) görüntülerinden batın bölgesindeki organlarının bölütlenmesi pek çok zorluk içeren bir uygulama alanıdır ve bu konudaki çalışmalar sınırlı sayıdadır. Batın bölgesinde yer alan, karaciğer, böbrekler, dalak, pankreas, safra kesesi gibi organların MR görüntüleri kullanılarak ileri seviye tıbbi analizi ve üç boyutlu incelenmesi pek çok tıbbi prosedür için mecburi olduğundan, bu çalışmada, ilgili organların bölütlenmesinde yukarıda belirtilen zorluklara karşı gürbüz, bölütlenecek organın özellikleri ve organların birbirleriyle olan ilişkilerini (konum vb.) göz önüne alan bir sistem geliştirilmiştir. Geliştirilen sistem farklı MR sekansları ile elde edilen görüntülere uygulanarak elde edilen sonuçlar tartışılmıştır.
- 30 September 2015
- Published by Journal of the Faculty of Engineering and Architecture of Gazi University in Gazi Üniversitesi Mühendislik-Mimarlık Fakültesi Dergisi
- Vol. 30 (3)
BATIN BÖLGESİ ORGANLARININ MR GÖRÜNTÜLERİNDEN ÇOK AŞAMALI HİYERARŞİK SINIFLAMA İLE BÖLÜTLENMESİ
Tıbbi görüntüleme ile anatomi hakkında ayrıntılı bilgi elde edinilebildiğinden, tanı amaçlı görüntüleme günümüzde birçok açıdan önem kazanmıştır. Görüntüleme cihazları tarafından sunulan verilerin fazlalığı ve çeşitliliği nedeniyle, tüm veri yerine görüntülerde sadece ilgilenilen dokunun belirlenerek ayrılması (Bölütlenmesi) sağlanabilir. Elcil yöntemler ile bölütleme yorucu, zaman alıcı ve deneyim gerektiren bir işlem olduğundan, otomatik yordamlara gereksinim duyulmaktadır. Geliştirilen yordamların klinik koşullarında kullanılabilmesi içinse yüksek başarıma sahip sonuçlar üretmeleri gerekmektedir. Manyetik Rezonans (MR) görüntülerinden batın bölgesindeki organlarının bölütlenmesi pek çok zorluk içeren bir uygulama alanıdır ve bu konudaki çalışmalar sınırlı sayıdadır. Batın bölgesinde yer alan, karaciğer, böbrekler, dalak, pankreas, safra kesesi gibi organların MR görüntüleri kullanılarak ileri seviye tıbbi analizi ve üç boyutlu incelenmesi pek çok tıbbi prosedür için mecburi olduğundan, bu çalışmada, ilgili organların bölütlenmesinde yukarıda belirtilen zorluklara karşı gürbüz, bölütlenecek organın özellikleri ve organların birbirleriyle olan ilişkilerini (konum vb.) göz önüne alan bir sistem geliştirilmiştir. Geliştirilen sistem farklı MR sekansları ile elde edilen görüntülere uygulanarak elde edilen sonuçlar tartışılmıştır.