MYManabu Yoshimura

Manabu Yoshimura

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Manabu Yoshimura has a total of 38 co-authors. Here are the top co-authors by number of shared publications:

  • Junya Hirata

    Faculty of Rehabilitation, Kawasaki University of Medical Welfare, Okayama, Japan

    4 shared publications
  • Katsutoshi Senoo

    Faculty of Rehabilitation, Kawasaki University of Medical Welfare, Okayama, Japan

    4 shared publications
  • Hiroshi Kurumadani

    Graduate School of Biomedical & Health Sciences, Hiroshima University, Hiroshima, Japan

    3 shared publications
  • Kozo Hanayama

    Department of Rehabilitation Medicine, Kawasaki Medical School, Kurashiki, Okayama, Japan

    3 shared publications
  • Seiji Kinoshita

    Rehabilitation Center, Kawasaki Medical School Hospital, Kurashiki, Okayama, Japan

    3 shared publications
  • Shota Date

    Graduate School of Biomedical & Health Sciences, Hiroshima University, Hiroshima, Japan

    3 shared publications

Latest Publications

  • Virtual reality–based myoelectric prosthetic control training: Effects of action observation and motor imagery with visual feedback of electromyographic signals

    by Manabu Yoshimura, Hiroshi Kurumadani, Tomotaka Ito, Takayuki Hosokawa, Junya Hirata, Katsutoshi Senoo, Seiji Kinoshita, Shota Date, Kozo Hanayama, Toru Sunagawa

    Background: Conventional myoelectric prostheses (myo-prostheses) training involves repetitive grasping and manipulation training, which requires considerable training time. It is necessary to develop a short and efficient myo-prostheses training. This study aimed to verify the immediate and sustained effects of action observation and motor imagery (AOMI) using virtual reality (VR) on myo-prostheses control and clarify the effect of visual feedback of electromyogram (EMG) signals during AOMI using VR. Study Design and Methods: We evaluated 24 healthy right-handed individuals wearing a myo-prostheses simulator in their dominant hands. We divided participants into 3 groups: VR video observation with EMG presentation during manipulation (VR+), VR video observation without EMG presentation (VR), and control group. We evaluated prosthetic control skills using the Grasp Force Adjustment Test (GFAT) and Bowknot task immediately before and after AOMI and 1 week later. In addition, we evaluated the level of immersion during AOMI. Results: The rate of change in the GFAT 1 week after the intervention was significantly greater in the VR+ (P < 0.05, d = 1.32) and VR (P < 0.01, d = 2.34) groups than in the control group. Immersion was significantly higher in the VR+ and VR groups than in the control group. The condition and time required for GFAT had significant effects, although the post-hoc test showed no significant difference between VR+ and VR groups. Conclusions: AOMI using VR had sustained effects on motor learning of myo-prosthetic control despite EMG presentation. Therefore, AOMI, using VR, manipulates prostheses once learned, and it might be used for future training of myo-prosthetic control.


  • Correlation between kinesthetic motor imagery of an amputated limb and phantom limb pain

    by Manabu Yoshimura, Hiroshi Kurumadani, Junya Hirata, Shota Date, Akio Ueda, Yosuke Ishii, Katsutoshi Senoo, Kozo Hanayama, Toru Sunagawa

    Background: Phantom limb pain (PLP) is a frequent painful sensation in amputees, and motor imagery (MI) is a useful approach for the treatment of this type of pain. However, it is not clear regarding the best MI modality for PLP. Objectives: The purpose of this study was to investigate the relationship between the PLP and MI modality in upper limb amputees. Study design: Observational study. Methods: Eleven patients who underwent unilateral upper limb amputation participated in this study. The MI modality (kinesthetic and visual) and PLP intensity were evaluated using the Kinesthetic and Visual Imagery Questionnaire (KVIQ)-20 and a visual analog scale. MI ability was also assessed during the hand mental rotation task. We examined the correlation between MI modalities, ability, and pain intensity. Results: The total KVIQ kinesthetic score was negatively correlated with pain intensity (r = −0.71, P < 0.01): the more vivid the kinesthetic imagery, the weaker the pain. In particular, the reduction in pain intensity was associated with strong kinesthetic imagery of opposing movements of the deficient thumb (r = −0.81, P < 0.01). The KVIQ visual score and MI ability were not associated with pain intensity. Conclusions: Our data showed that the reduction of PLP could be associated with the kinesthetic modality of MI but not with visual modality or MI ability. In other words, it was suggested that the more vivid the sensation of moving muscles and joints in the defect area, the lower the PLP intensity. To reduce PLP, clinicians may prefer interventions using the kinesthetic modality.


  • Open Access

    Quantitative evaluation of abnormal finger movements in myelopathy hand during the grip and release test using gyro sensors

    by Shota Date, Kazuyoshi Nakanishi, Yasushi Fujiwara, Kiyotaka Yamada, Naosuke Kamei, Hiroshi Kurumadani, Manabu Yoshimura, Akio Ueda, Yosuke Ishii, Ryo Ohta, et al.

    Previous studies have reported qualitative characteristics of myelopathy hand, but few studies have reported quantitative kinematic parameters of this condition. Our purpose of this study was to quantitatively evaluate the abnormal finger movements in patients with cervical compressive myelopathy (CCM) (termed myelopathy hand) and to understand the characteristics of myelopathy hand during the grip and release test (GRT) using gyro sensors. Sixty patients with CCM (severe: n = 30; mild-to-moderate: n = 30) and sixty healthy adults (age-matched control: n = 30; young control: n = 30) were included in this study. All participants performed the GRT. The index and little fingers’ and the wrist’s movements during the GRT were recorded using three gyro sensors. The number of cycles, switching time-delay, time per cycle, and peak angular velocity were calculated and compared between groups. Patients with severe CCM had the lowest number of cycles and longest switching time-delays, followed by patients with mild-to-moderate CCM, the age-matched control group, and the young control group. The time per cycle and the peak angular velocities of fingers in participants with severe CCM were significantly lower than those in participants with mild-to-moderate CCM; however, there were no significant differences between the control groups. The peak angular velocities of fingers were significantly lower during extension motions than during flexion motions in participants with CCM. Participants with CCM have lower peak angular velocities during finger movement. Finger extension also is impaired in participants with CCM. Abnormal finger movements and the severity of myelopathy in participants with CCM can be assessed using gyro sensors.


  • Open Access

    Virtual reality-based action observation facilitates the acquisition of body-powered prosthetic control skills

    by Manabu Yoshimura, Hiroshi Kurumadani, Junya Hirata, Hiroshi Osaka, Katsutoshi Senoo, Shota Date, Akio Ueda, Yosuke Ishii, Seiji Kinoshita, Kozo Hanayama, et al.

    Background: Regular body-powered (BP) prosthesis training facilitates the acquisition of skills through repeated practice but requires adequate time and motivation. Therefore, auxiliary tools such as indirect training may improve the training experience and speed of skill acquisition. In this study, we examined the effects of action observation (AO) using virtual reality (VR) as an auxiliary tool. We used two modalities during AO: three-dimensional (3D) VR and two-dimensional (2D) computer tablet devices (Tablet). Each modality was tested from first- and third-person perspectives. Methods: We studied 40 healthy right-handed participants wearing a BP prosthesis simulator on their non-dominant hands. The participants were divided into five groups based on combinations of the different modalities and perspectives: first-person perspective on VR (VR1), third-person perspective on VR (VR3), first-person perspective on a tablet (Tablet1), third-person perspective on a tablet (Tablet3), and a control group (Control). The intervention groups observed and imitated the video image of prosthesis operation for 10 min in each of two sessions. We evaluated the level of immersion during AO using the visual analogue scale. Prosthetic control skills were evaluated using the Box and Block Test (BBT) and a bowknot task (BKT). Results: In the BBT, there were no significant differences in the amount of change in the skills between the five groups. In contrast, the relative changes in the BKT prosthetic control skills in VR1 (p < 0.001, d = 3.09) and VR3 (p < 0.001, d = 2.16) were significantly higher than those in the control group. Additionally, the immersion scores of VR1 (p < 0.05, d = 1.45) and VR3 (p < 0.05, d = 1.18) were higher than those of Tablet3. There was a significant negative correlation between the immersion scores and the relative change in the BKT scores (Spearman’s rs = − 0.47, p < 0.01). Conclusions: Using the BKT of bilateral manual dexterity, VR-based AO significantly improved short-term prosthetic control acquisition. Additionally, it appeared that the higher the immersion score was, the shorter the execution time of the BKT task. Our findings suggest that VR-based AO training may be effective in acquiring bilateral BP prosthetic control, which requires more 3D-based operation.


  • Open Access

    Virtual reality-based action observation facilitates acquisition of body-powered prosthetic control skills

    by Manabu Yoshimura, Hiroshi Kurumadani, Junya Hirata, Hiroshi Osaka, Katsutoshi Senoo, Shota Date, Akio Ueda, Yosuke Ishii, Seiji Kinoshita, Kozo Hanayama, et al.

    Background Regular body-powered prosthesis (bp-prosthesis) training often facilitates acquisition of skills through repeated practice but requires adequate time and motivation. Therefore, if there are auxiliary tools, such as indirect training, skill acquisition may be easy. In this study, we examined the effects of action observation (AO) using virtual reality (VR) as an auxiliary tool. We examined two different modalities during AO, VR and tablet device (Tab), and two perspectives, first- and third-person perspectives. This study aimed to examine whether AO training using VR is effective in acquiring bp-prosthetic control skills in the short term. Methods Forty healthy right-handed participants simulated bp-prosthesis with the non-dominant hand. They were divided into five groups with different interventions and displays for AO: first-person perspective on VR (VR1st), third-person perspective on VR (VR3rd), first-person perspective on Tab (Tab1st), third-person perspective on Tab (Tab3rd), and control group (Con) without AO. Participants of VR1st, VR3rd, Tab1st, and Tab3rd observed the video image of experts operating prosthesis twice, 10 min each time. We evaluated the immersion during the video observation using the Visual Analog Scale. Prosthetic control skills were evaluated using the box and block test (BBT) and bowknot task (BKT). Results In BBT, no significant enhancements of prosthetic control skills between groups were found. In contrast, the BKT change rates of prosthetic control skills in VR1st and VR3rd were significantly higher than those in Con (p < 0.001). Additionally, immersion scores of VR1st and VR3rd were higher than those of Tab3rd (p < 0.05), and there was a significant negative correlation between immersion and BKT change rate (Spearman’s rs = -0.47, p < 0.01). Conclusions In BKT (bilateral manual dexterity), VR video viewing led to significantly better short-term prosthetic control acqusition than Con. Additionally, it was suggested that the higher the immersion, the shorter the BKT task execution time. Our findings suggest that VR-based AO training is effective in acquiring bp-prosthetic control in the short term. Especially, it is effective for bilateral prosthetic control, which is necessary in the daily life of upper limb amputees.

  • Open Access

    Beta-3 adrenergic agonist, BRL-26830A, and alpha/beta blocker, arotinolol, markedly increase regional blood flow in the brown adipose tissue in anesthetized rats.

    by Hakuo Takahashi, Toshihide Yoshida, Masato Nishimura, Tadashi Nakanishi, Motoharu Kondo, Manabu Yoshimura

    Regional vascular effects of some adrenergic agents, focussing on brown adipose tissue (BAT), were investigated using tracer microspheres with a reference sample method in the anesthetized rat. Intravenous injections of 0.5 mg/kg BRL-26830A, a β3-adrenergic agonist, increased heart rate, but changes in blood pressure and cardiac output were not significant. The drug decreased blood flow in the brain, the spleen and the kidneys, but markedly increased it in BAT. At 2 mg/kg, arotinolol, an α/β-adrenergic blocker, decreased blood pressure by 20 mmHg and increased cardiac output by 95 ml/min/kg. It slightly but significantly decreased blood flow in the liver and the spleen, but markedly increased the flow in BAT. Acebutolol, a β1-adrenergic blocker, decreased blood flow in the liver, the spleen, the pancreas, the kidneys, the adrenals, the skeletal muscle and the skin. Bunazosin, an α1-adrenergic blocker, decreased it in all organs and tissue expect the brain and BAT. The pattern of redistribution of blood flow by arotinolol was very similar to that caused by BRL-26830A. Acebutolol and bunazosin rather decreased the blood flow in the BAT. These results indicate that stimulation of β3-adrenergic receptors, in BAT results in vasodilation, and that arotinolol may bind to those β3-adrenergic receptors.