Bin Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Bin Wang has a total of 88 co-authors. Here are the top co-authors by number of shared publications:
- Chen Yao
Peking University Clinical Research Institute, Peking University First Hospital, Beijing, China
13 shared publications - Feifei Jin
Trauma Medicine Center, Peking University People's Hospital, Beijing, China
11 shared publications Junkai Lai
Institute of Automation, Chinese Academy of Sciences , No. 95 Zhongguancun Road, Haidian District, Beijing 100080
6 shared publications- Junkai Lai
Institute of Automation, Chinese Academy of Sciences
6 shared publications - Ping Zhang
Department of Cardiology, Beijing Tsinghua Changgung Hospital, School of Clinical Medicine, Tsinghua University, Beijing 102218, China
6 shared publications - Dong Li
Medical Data Science Center, Beijing Tsinghua Changgung Hospital, School of Clinical Medicine, Tsinghua Medicine, Tsinghua University, Beijing, China
4 shared publications
Latest Publications
- Open Access
- 1 January 2027
- Published by XMLink in Korean Circulation Journal
- Vol. 57
Triglyceride-Glucose Index and Triglycerides Within a Dual-Axis Framework of ApoB and the LDL-C/TC Ratio: A Prospective UK Biobank Study
Wang B, et al. Korean Circ J. 2027 ;57:e79. https://doi.org/10.4070/kcj.2026.0299
- 1 January 2027
- Published by XMLink in Korean Circulation Journal
- Vol. 57
Open AccessTriglyceride-Glucose Index and Triglycerides Within a Dual-Axis Framework of ApoB and the LDL-C/TC Ratio: A Prospective UK Biobank Study
Wang B, et al. Korean Circ J. 2027 ;57:e79. https://doi.org/10.4070/kcj.2026.0299
- 9 May 2026
- Published by Oxford University Press (OUP) in European Journal of Preventive Cardiology
ASCVD risk stratification using apolipoprotein B and the LDL-C to total cholesterol ratio
Aims: Low-density lipoprotein cholesterol (LDL-C) is causal for atherosclerotic cardiovascular disease (ASCVD), yet substantial risk heterogeneity persists across the LDL-C distribution. We tested whether LDL-related susceptibility is better explained by a dual-axis structure integrating apolipoprotein B (ApoB)-defined particle burden with LDL cholesterol composition captured by the LDL-C/total cholesterol (LDL-C/TC) ratio. Methods and results: We analysed six US cohorts of adults without cardiovascular disease or receiving lipid-lowering therapy at baseline. ApoB and the LDL-C/TC ratio were dichotomized at 90 mg/dL and 0.60, respectively, to define four phenotypes. Incident ASCVD was assessed using multivariable Cox proportional hazards models, with prespecified subgroup analyses by age, sex, and clinical risk groups. Among 9238 Atherosclerosis Risk in Communities Study participants (2038 ASCVD events; median follow-up 25.6 years), ApoB and the Martin/Hopkins LDL-C/TC ratio showed stronger per–SD associations with ASCVD [adjusted hazard ratios (HRs) 1.20 and 1.27] than LDL-C levels. Cross-classification of ApoB and the LDL-C/TC ratio identified four phenotypes. Dual-normal participants exhibited the lowest ASCVD incidence, whereas the dual-elevated phenotype showed the highest risk (HR 1.67). Among discordant phenotypes, the low-ApoB/high-ratio group was associated with modestly higher risk (HR 1.28), while the high-ApoB/low-ratio phenotype demonstrated borderline associations. Conclusion: LDL-related atherogenic risk is more coherently explained by a dual-axis framework integrating ApoB-defined particle burden with LDL cholesterol composition captured by the LDL-C/TC ratio. This structure reveals composition-driven vulnerability not apparent from ApoB or contemporary risk scores and supports a scalable strategy in which routine ratio interpretation, coupled with selective ApoB testing, may enhance ASCVD risk stratification within preventive paradigms.
- 9 May 2026
- Published by Oxford University Press (OUP) in European Journal of Preventive Cardiology
ASCVD risk stratification using apolipoprotein B and the LDL-C to total cholesterol ratio
Aims: Low-density lipoprotein cholesterol (LDL-C) is causal for atherosclerotic cardiovascular disease (ASCVD), yet substantial risk heterogeneity persists across the LDL-C distribution. We tested whether LDL-related susceptibility is better explained by a dual-axis structure integrating apolipoprotein B (ApoB)-defined particle burden with LDL cholesterol composition captured by the LDL-C/total cholesterol (LDL-C/TC) ratio. Methods and results: We analysed six US cohorts of adults without cardiovascular disease or receiving lipid-lowering therapy at baseline. ApoB and the LDL-C/TC ratio were dichotomized at 90 mg/dL and 0.60, respectively, to define four phenotypes. Incident ASCVD was assessed using multivariable Cox proportional hazards models, with prespecified subgroup analyses by age, sex, and clinical risk groups. Among 9238 Atherosclerosis Risk in Communities Study participants (2038 ASCVD events; median follow-up 25.6 years), ApoB and the Martin/Hopkins LDL-C/TC ratio showed stronger per–SD associations with ASCVD [adjusted hazard ratios (HRs) 1.20 and 1.27] than LDL-C levels. Cross-classification of ApoB and the LDL-C/TC ratio identified four phenotypes. Dual-normal participants exhibited the lowest ASCVD incidence, whereas the dual-elevated phenotype showed the highest risk (HR 1.67). Among discordant phenotypes, the low-ApoB/high-ratio group was associated with modestly higher risk (HR 1.28), while the high-ApoB/low-ratio phenotype demonstrated borderline associations. Conclusion: LDL-related atherogenic risk is more coherently explained by a dual-axis framework integrating ApoB-defined particle burden with LDL cholesterol composition captured by the LDL-C/TC ratio. This structure reveals composition-driven vulnerability not apparent from ApoB or contemporary risk scores and supports a scalable strategy in which routine ratio interpretation, coupled with selective ApoB testing, may enhance ASCVD risk stratification within preventive paradigms.
- Open Access
- 8 October 2025
- Published by JMIR Publications Inc. in JMIR Aging
- Vol. 8, e76981
Comparative Diagnostic Accuracy of AI-Assisted Fluorine-18 Fluorodeoxyglucose Positron Emission Tomography Versus Structural Magnetic Resonance Imaging in Alzheimer Disease: Systematic Review and Meta-Analysis
Background: Neuroimaging is crucial in the diagnosis of Alzheimer disease (AD). In recent years, artificial intelligence (AI)–based neuroimaging technology has rapidly developed, providing new methods for accurate diagnosis of AD, but its performance differences still need to be systematically evaluated. Objective: This study aims to conduct a systematic review and meta-analysis comparing the diagnostic performance of AI-assisted fluorine-18 fluorodeoxyglucose positron emission tomography (18F-FDG PET) and structural magnetic resonance imaging (sMRI) for AD. Methods: Databases including Web of Science, PubMed, and Embase were searched from inception to January 2025 to identify original studies that developed or validated AI models for AD diagnosis using 18F-FDG PET or sMRI. Methodological quality was assessed using the TRIPOD-AI (Transparent Reporting of a Multivariable Prediction Model for Individual Prognosis or Diagnosis–Artificial Intelligence) checklist. A bivariate mixed-effects model was employed to calculate pooled sensitivity, specificity, and summary receiver operating characteristic curve area (SROC-AUC). Results: A total of 38 studies were included, with 28 moderate-to-high-quality studies analyzed. Pooled SROC-AUC values were 0.94 (95% CI 0.92‐0.96) for sMRI and 0.96 (95% CI 0.94‐0.98) for 18F-FDG PET, demonstrating statistically significant intermodal differences (P=.02). Subgroup analyses revealed that for machine learning, pooled SROC-AUCs were 0.89 (95% CI 0.86‐0.92) for sMRI and 0.95 (95% CI 0.92‐0.96) for 18F-FDG PET, while for deep learning, these values were 0.96 (95% CI 0.94‐0.97) and 0.97 (95% CI 0.96‐0.99), respectively. Meta-regression identified heterogeneity arising from study quality stratification, algorithm types, and validation strategies. Conclusions: Both AI-assisted 18F-FDG PET and sMRI exhibit high diagnostic accuracy in AD, with 18F-FDG PET demonstrating superior overall diagnostic performance compared to sMRI.
- 8 October 2025
- Published by JMIR Publications Inc. in JMIR Aging
- Vol. 8, e76981
Open AccessComparative Diagnostic Accuracy of AI-Assisted Fluorine-18 Fluorodeoxyglucose Positron Emission Tomography Versus Structural Magnetic Resonance Imaging in Alzheimer Disease: Systematic Review and Meta-Analysis
Background: Neuroimaging is crucial in the diagnosis of Alzheimer disease (AD). In recent years, artificial intelligence (AI)–based neuroimaging technology has rapidly developed, providing new methods for accurate diagnosis of AD, but its performance differences still need to be systematically evaluated. Objective: This study aims to conduct a systematic review and meta-analysis comparing the diagnostic performance of AI-assisted fluorine-18 fluorodeoxyglucose positron emission tomography (18F-FDG PET) and structural magnetic resonance imaging (sMRI) for AD. Methods: Databases including Web of Science, PubMed, and Embase were searched from inception to January 2025 to identify original studies that developed or validated AI models for AD diagnosis using 18F-FDG PET or sMRI. Methodological quality was assessed using the TRIPOD-AI (Transparent Reporting of a Multivariable Prediction Model for Individual Prognosis or Diagnosis–Artificial Intelligence) checklist. A bivariate mixed-effects model was employed to calculate pooled sensitivity, specificity, and summary receiver operating characteristic curve area (SROC-AUC). Results: A total of 38 studies were included, with 28 moderate-to-high-quality studies analyzed. Pooled SROC-AUC values were 0.94 (95% CI 0.92‐0.96) for sMRI and 0.96 (95% CI 0.94‐0.98) for 18F-FDG PET, demonstrating statistically significant intermodal differences (P=.02). Subgroup analyses revealed that for machine learning, pooled SROC-AUCs were 0.89 (95% CI 0.86‐0.92) for sMRI and 0.95 (95% CI 0.92‐0.96) for 18F-FDG PET, while for deep learning, these values were 0.96 (95% CI 0.94‐0.97) and 0.97 (95% CI 0.96‐0.99), respectively. Meta-regression identified heterogeneity arising from study quality stratification, algorithm types, and validation strategies. Conclusions: Both AI-assisted 18F-FDG PET and sMRI exhibit high diagnostic accuracy in AD, with 18F-FDG PET demonstrating superior overall diagnostic performance compared to sMRI.
- Open Access
- 5 May 2025
- Published by JMIR Publications Inc. in JMIR Preprints
Accuracy Comparison of AI-Assisted 18F-FDG PET and Structural MRI in Alzheimer's Disease Diagnosis: A Systematic Review and Meta-Analysis (Preprint)
BACKGROUND Neuroimaging is crucial in the diagnosis of Alzheimer's disease (AD). In recent years, artificial intelligence (AI) based neuroimaging technology has rapidly developed, providing new methods for accurate diagnosis of AD, but its performance differences still need to be systematically evaluated. OBJECTIVE To conduct a systematic review and meta-analysis comparing the diagnostic performance of AI-assisted fluorine-18 fluorodeoxyglucose positron emission tomography (18F-FDG PET) and structural magnetic resonance imaging (sMRI) for AD. METHODS Databases including Web of Science, PubMed, and Embase were searched from inception to January 2025 to identify original studies developing or validating AI models for AD diagnosis using ¹⁸F-FDG PET or sMRI. Methodological quality was assessed using the Transparent Reporting of a Multivariable Prediction Model for Individual Prognosis or Diagnosis-Artificial Intelligence(TRIPOD-AI) checklist. A bivariate mixed-effects model was employed to calculate pooled sensitivity, specificity, and summary receiver operating characteristic curve area (SROC-AUC). RESULTS 38 studies were included, with 28 moderate-to-high-quality studies analyzed. Pooled SROC-AUC values were 0.94 (95% CI: 0.92–0.96) for sMRI and 0.96 (95% CI: 0.94–0.98) for ¹⁸F-FDG PET, demonstrating statistically significant intermodal differences (P=.02). Subgroup analyses revealed that in machine learning (ML), pooled SROC-AUCs were 0.89 (95% CI: 0.86–0.92) for sMRI and 0.95 (95% CI: 0.92–0.96) for ¹⁸F-FDG PET, while in deep learning (DL), these values were 0.96 (95% CI: 0.94–0.97) and 0.97 (95% CI: 0.96–0.99), respectively. Meta-regression identified heterogeneity arising from study quality stratification, algorithm types, and validation strategies. CONCLUSIONS Both AI-assisted 18F-FDG PET and sMRI exhibit high diagnostic accuracy in AD, with 18F-FDG PET demonstrating superior overall diagnostic performance compared to sMRI.
- 5 May 2025
- Published by JMIR Publications Inc. in JMIR Preprints
Open AccessAccuracy Comparison of AI-Assisted 18F-FDG PET and Structural MRI in Alzheimer's Disease Diagnosis: A Systematic Review and Meta-Analysis (Preprint)
BACKGROUND Neuroimaging is crucial in the diagnosis of Alzheimer's disease (AD). In recent years, artificial intelligence (AI) based neuroimaging technology has rapidly developed, providing new methods for accurate diagnosis of AD, but its performance differences still need to be systematically evaluated. OBJECTIVE To conduct a systematic review and meta-analysis comparing the diagnostic performance of AI-assisted fluorine-18 fluorodeoxyglucose positron emission tomography (18F-FDG PET) and structural magnetic resonance imaging (sMRI) for AD. METHODS Databases including Web of Science, PubMed, and Embase were searched from inception to January 2025 to identify original studies developing or validating AI models for AD diagnosis using ¹⁸F-FDG PET or sMRI. Methodological quality was assessed using the Transparent Reporting of a Multivariable Prediction Model for Individual Prognosis or Diagnosis-Artificial Intelligence(TRIPOD-AI) checklist. A bivariate mixed-effects model was employed to calculate pooled sensitivity, specificity, and summary receiver operating characteristic curve area (SROC-AUC). RESULTS 38 studies were included, with 28 moderate-to-high-quality studies analyzed. Pooled SROC-AUC values were 0.94 (95% CI: 0.92–0.96) for sMRI and 0.96 (95% CI: 0.94–0.98) for ¹⁸F-FDG PET, demonstrating statistically significant intermodal differences (P=.02). Subgroup analyses revealed that in machine learning (ML), pooled SROC-AUCs were 0.89 (95% CI: 0.86–0.92) for sMRI and 0.95 (95% CI: 0.92–0.96) for ¹⁸F-FDG PET, while in deep learning (DL), these values were 0.96 (95% CI: 0.94–0.97) and 0.97 (95% CI: 0.96–0.99), respectively. Meta-regression identified heterogeneity arising from study quality stratification, algorithm types, and validation strategies. CONCLUSIONS Both AI-assisted 18F-FDG PET and sMRI exhibit high diagnostic accuracy in AD, with 18F-FDG PET demonstrating superior overall diagnostic performance compared to sMRI.
- Open Access
- 22 April 2025
- Published by IMR Press in Reviews in Cardiovascular Medicine
- Vol. 26 (4) , 28251
Induced Pluripotent Stem Cells in Congenital Long QT Syndrome: Research Progress and Clinical Applications
Congenital long QT syndrome (LQTS) is a potentially life-threatening hereditary arrhythmia characterized by a prolonged QT interval on electrocardiogram (ECG) due to delayed ventricular repolarization. This condition predisposes individuals to severe arrhythmic events, including ventricular tachycardia and sudden cardiac death. Traditional approaches to LQTS research and treatment are limited by an incomplete understanding of its gene-specific pathophysiology, variable clinical presentation, and the challenges associated with developing effective, personalized therapies. Recent advances in human induced pluripotent stem cell (iPSC) technology have opened new avenues for elucidating LQTS mechanisms and testing therapeutic strategies. By generating cardiomyocytes from patient-specific iPSCs (iPSC-CMs), it is now possible to recreate the patient’s genetic context and study LQTS in a controlled environment. This comprehensive review describes how iPSC technology deepens our understanding of LQTS and accelerates the development of tailored treatments, as well as ongoing challenges such as incomplete cell maturation and cellular heterogeneity.
- 22 April 2025
- Published by IMR Press in Reviews in Cardiovascular Medicine
- Vol. 26 (4) , 28251
Open AccessInduced Pluripotent Stem Cells in Congenital Long QT Syndrome: Research Progress and Clinical Applications
Congenital long QT syndrome (LQTS) is a potentially life-threatening hereditary arrhythmia characterized by a prolonged QT interval on electrocardiogram (ECG) due to delayed ventricular repolarization. This condition predisposes individuals to severe arrhythmic events, including ventricular tachycardia and sudden cardiac death. Traditional approaches to LQTS research and treatment are limited by an incomplete understanding of its gene-specific pathophysiology, variable clinical presentation, and the challenges associated with developing effective, personalized therapies. Recent advances in human induced pluripotent stem cell (iPSC) technology have opened new avenues for elucidating LQTS mechanisms and testing therapeutic strategies. By generating cardiomyocytes from patient-specific iPSCs (iPSC-CMs), it is now possible to recreate the patient’s genetic context and study LQTS in a controlled environment. This comprehensive review describes how iPSC technology deepens our understanding of LQTS and accelerates the development of tailored treatments, as well as ongoing challenges such as incomplete cell maturation and cellular heterogeneity.
- Open Access
Exploring data security risks associated with trauma medical data within hospitals in China: a qualitative study
Objectives To explore data security risks associated with trauma medical data within hospitals in China, identify and explore the potential underlying factors contributing to these risks and collect suggestions from different stakeholders. Design This is a qualitative study involving two types of hospital personnel. Data analysis was performed using thematic analysis. Setting The study was conducted in 21 tertiary hospitals from 12 provinces in China, distributed across the eastern, central and western regions of the country. The interviews were conducted between April and August 2022. Participants A total of 27 respondents (7 department heads and 20 doctors) were interviewed through stratified purposive sampling. Results Data security risks associated with trauma medical data might arise from trauma physicians’ inadequate management of trauma data, the absence of trauma data administrators and data management systems and the lack of security measures for trauma databases. Feasible suggestions included training trauma physicians, establishing a trauma data administrator and a trauma data management system and improving basic data security protection measures. Conclusions Determining the risks of trauma medical data security and providing tailored suggestions contribute to the development of healthcare data governance in China. This research establishes a foundation for addressing the current risks related to trauma medical data security and could contribute to efforts to improve the overall capacity of trauma data management in China.
Open AccessExploring data security risks associated with trauma medical data within hospitals in China: a qualitative study
Objectives To explore data security risks associated with trauma medical data within hospitals in China, identify and explore the potential underlying factors contributing to these risks and collect suggestions from different stakeholders. Design This is a qualitative study involving two types of hospital personnel. Data analysis was performed using thematic analysis. Setting The study was conducted in 21 tertiary hospitals from 12 provinces in China, distributed across the eastern, central and western regions of the country. The interviews were conducted between April and August 2022. Participants A total of 27 respondents (7 department heads and 20 doctors) were interviewed through stratified purposive sampling. Results Data security risks associated with trauma medical data might arise from trauma physicians’ inadequate management of trauma data, the absence of trauma data administrators and data management systems and the lack of security measures for trauma databases. Feasible suggestions included training trauma physicians, establishing a trauma data administrator and a trauma data management system and improving basic data security protection measures. Conclusions Determining the risks of trauma medical data security and providing tailored suggestions contribute to the development of healthcare data governance in China. This research establishes a foundation for addressing the current risks related to trauma medical data security and could contribute to efforts to improve the overall capacity of trauma data management in China.