Dmitry Alexeev
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Dmitry Alexeev has a total of 47 co-authors. Here are the top co-authors by number of shared publications:
- Petros Koumoutsakos
Harvard University
4 shared publications - Lucas Amoudruz
School of Engineering and Applied Sciences, Harvard University, 29 Oxford St, Cambridge, Massachusetts, 02138, UNITED STATES
3 shared publications Sergey Litvinov
Computational Science and Engineering Laboratory, ETH Zurich, CH-8092 Zurich, Switzerland
2 shared publications- Alexandru Calotoiu
ETH Zurich, Zurich, Switzerland
1 shared publication - Andreas Herten
Forschungszentrum Jülich
1 shared publication - Athena E. Economides
Institute of Neuropathology, University of Zürich, Zürich, Switzerland
1 shared publication
Latest Publications
- Open Access
- 15 November 2025
- Published by Association for Computing Machinery (ACM)
- p. 125-136
Computing the Full Earth System at 1km Resolution
- 15 November 2025
- Published by Association for Computing Machinery (ACM)
- p. 125-136
Open AccessComputing the Full Earth System at 1km Resolution
- 14 May 2025
- Published by American Physical Society (APS) in Physical Review Fluids
- Vol. 10 (5)
Inertial focusing of spherical particles: The effects of rotational motion
- 14 May 2025
- Published by American Physical Society (APS) in Physical Review Fluids
- Vol. 10 (5)
Inertial focusing of spherical particles: The effects of rotational motion
- 22 March 2021
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 15 (3) , 034062
Hierarchical Bayesian Uncertainty Quantification for a Model of the Red Blood Cell
Simulations of blood flows in microfluidic devices and physiological systems are gaining importance in complementing experimental and clinical studies. The predictive capabilities of these simulations hinge on the parameters of the red blood cell (RBC) model that are usually calibrated from experimental data. However, these parameter values may vary drastically when calibrated using different experimental quantities or experimental settings. In turn, the results of existing blood flow simulations largely depend on the utilized parameters that have been chosen to validate a particular experiment. We suggest a revision to this type of model calibration to properly integrate experimental data in the computational models and accordingly inform their predictions. In this context, we introduce the calibration of a popular RBC model using data-driven, hierarchical Bayesian inference. We employ data from classical experiments of RBC stretching by optical tweezers and tank treading in shear flows, and distinguish the calibration of the model parameters through single-level and hierarchical Bayesian uncertainty quantification. We find that the optimal model parameters depend not only on the data used for the inference but also on the way the data are used in the inference process. Single-level Bayesian models predict well the data used in their calibration, but are inferior to the hierarchical Bayesian model at predicting previously unseen data. This work demonstrates that the proper integration of experimental data is essential for the development of a robust and transferable RBC model. We believe that the present study can serve as a prototype across scientific fields, in revising the integration of computational models and heterogeneous experimental data.
- 22 March 2021
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 15 (3) , 034062
Hierarchical Bayesian Uncertainty Quantification for a Model of the Red Blood Cell
Simulations of blood flows in microfluidic devices and physiological systems are gaining importance in complementing experimental and clinical studies. The predictive capabilities of these simulations hinge on the parameters of the red blood cell (RBC) model that are usually calibrated from experimental data. However, these parameter values may vary drastically when calibrated using different experimental quantities or experimental settings. In turn, the results of existing blood flow simulations largely depend on the utilized parameters that have been chosen to validate a particular experiment. We suggest a revision to this type of model calibration to properly integrate experimental data in the computational models and accordingly inform their predictions. In this context, we introduce the calibration of a popular RBC model using data-driven, hierarchical Bayesian inference. We employ data from classical experiments of RBC stretching by optical tweezers and tank treading in shear flows, and distinguish the calibration of the model parameters through single-level and hierarchical Bayesian uncertainty quantification. We find that the optimal model parameters depend not only on the data used for the inference but also on the way the data are used in the inference process. Single-level Bayesian models predict well the data used in their calibration, but are inferior to the hierarchical Bayesian model at predicting previously unseen data. This work demonstrates that the proper integration of experimental data is essential for the development of a robust and transferable RBC model. We believe that the present study can serve as a prototype across scientific fields, in revising the integration of computational models and heterogeneous experimental data.
- 1 September 2020
- Published by Elsevier in Computer Physics Communications
- Vol. 254
Mirheo: High-performance mesoscale simulations for microfluidics
- 1 September 2020
- Published by Elsevier in Computer Physics Communications
- Vol. 254
Mirheo: High-performance mesoscale simulations for microfluidics
- Open Access
- 15 November 2015
- Published by Association for Computing Machinery (ACM)
- p. 1-12
The in-silico lab-on-a-chip
We present simulations of blood and cancer cell separation in complex microfluidic channels with subcellular resolution, demonstrating unprecedented time to solution, performing at 65.5% of the available 39.4 PetaInstructions/s in the 18, 688 nodes of the Titan supercomputer. These simulations outperform by one to three orders of magnitude the current state of the art in terms of numbers of simulated cells and computational elements. The computational setup emulates the conditions and the geometric complexity of microfluidic experiments and our results reproduce the experimental findings. These simulations provide sub-micron resolution while accessing time scales relevant to engineering designs. We demonstrate an improvement of up to 45X over competing state-of-the-art solvers, thus establishing the frontiers of simulations by particle based methods. Our simulations redefine the role of computational science for the development of microfluidics -- a technology that is becoming as important to medicine as integrated circuits have been to computers.
- 15 November 2015
- Published by Association for Computing Machinery (ACM)
- p. 1-12
Open AccessThe in-silico lab-on-a-chip
We present simulations of blood and cancer cell separation in complex microfluidic channels with subcellular resolution, demonstrating unprecedented time to solution, performing at 65.5% of the available 39.4 PetaInstructions/s in the 18, 688 nodes of the Titan supercomputer. These simulations outperform by one to three orders of magnitude the current state of the art in terms of numbers of simulated cells and computational elements. The computational setup emulates the conditions and the geometric complexity of microfluidic experiments and our results reproduce the experimental findings. These simulations provide sub-micron resolution while accessing time scales relevant to engineering designs. We demonstrate an improvement of up to 45X over competing state-of-the-art solvers, thus establishing the frontiers of simulations by particle based methods. Our simulations redefine the role of computational science for the development of microfluidics -- a technology that is becoming as important to medicine as integrated circuits have been to computers.