KCKevin K. Crown

Kevin K. Crown

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Kevin K. Crown has a total of 33 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Water-soluble swab material for environmental sampling

    by Kevin K. Crown, Timothy N. Lambert, Maria Kelly, Nelson S. Bell, Joshua Santarpia

    Biological threats represent a growing vulnerability to national security, affecting both military and civilian populations. Deliberate dissemination of chemical and biological (CB) agents can have immediate and significant impacts on public health and the economy, highlighting the need for faster and more efficient techniques to assess contamination and safely clear affected areas for public reentry following an accidental or intentional biological release. Current surface sampling procedures set forth by the Centers for Disease Control and Prevention (CDC) call for sampling swab materials that are not soluble in aqueous bacterial growth medium. These have been shown here to be inefficient, releasing less than 40% of the captured biological material into aqueous solution for detection. Since the CDC put these procedures in place, there has been no impetus for industry to develop sampling swabs that release 100% of the sample they capture from a non-porous surface. This project developed cost-effective, novel, biologically hospitable, adsorbent materials that dissolve in water, releasing 100% of the captured sample. These fibers maintain structural integrity during sampling, can be premoistened without premature dissolution, and rapidly dissolve in solution, facilitating efficient sample release. Forcespun PVA fibrous swabs demonstrated significantly higher spore capture and release efficiency compared to traditional materials, without inhibiting bacterial growth or spore germination. These swabs could significantly improve current sampling technologies and procedures via increased spore detection and analysis efficiency. Higher sampling efficiency could translate to fewer samples required for analysis and significantly less time to render an area safe for public reentry. Increased sampling efficiency would also provide faster impact data to decision makers and lead to improved consequence management. Prior to this study, water-soluble swabs suitable for this purpose have not yet been developed. IMPORTANCE: Accurate environmental sampling is critical for detecting low‐level microbial contamination in both public health and biodefense settings. Our water‐soluble PVA swab material achieves up to 100% spore release from non-porous surfaces, more than double the recovery of traditional swabs, while being compatible with scalable, low‐cost fabrication methods. This new tool will enable more sensitive, faster, and more reliable surface monitoring across a wide range of environmental and diagnostic applications.

  • Water-soluble aerosol collection medium for environmental bioaerosol collections

    by Kevin K. Crown, Sean M. Kinahan, Gabriel A. Lucero, Eric C. Carnes, Yury E. Salkovskiy, Aleksandr Fadeev, Joshua L. Santarpia

    Filtration is one of the most common means of collecting aerosolized particles of biological origin for downstream analysis. Collection media that are not water-soluble are typically made of glass ...

  • Open Access

    Micropleated Nanofibrous Filters for High‐Efficiency Submicron Aerosol Filtration: A Comparative Study with Chemical, Biological, Radiological, and Nuclear Gas Mask Filters

    by Aleksandr Fadeev, Kevin Crown, Sean Kinahan, Gabriel Lucero, Hayden Stromsodt, Svetlana Romanova, Yury Salkovskiy

    Electrospinning is a versatile technique for producing polymer nanofibrous fabrics with enhanced functionalities, making it attractive for next‐generation respiratory protection. A major limitation of electrospun filters designed for submicron aerosol capture at ≥99.99% efficiency is their comparatively high breathing resistance relative to conventional glass fiber and expanded polytetrafluoroethylene (ePTFE) media. To address this limitation, this study introduces micropleated filters made by multiple‐jet needleless electrospinning, where nanofibers are deposited onto uniaxially prestretched textile substrates. Upon release, the substrates contracted to their original dimensions, forming densely packed micro‐pleats that increased the effective surface area without altering the overall filter size. Prestretching the substrate to 225% prior to nanofiber deposition produced a twofold increase in quality factor compared with nanofiber mats deposited on unstretched substrates, driven by improved submicron aerosol filtration and reduced pressure drop. The micro‐pleated filters achieved quality factors exceeding 0.26 Pa −1 , comparable to high‐performance ePTFE‐based military gas mask filters and more than three times higher than glass fiber filters. The micropleated filters also outperformed ePTFE filters in capturing and releasing aerosolized MS2 bacteriophage. These findings demonstrate that micropleated electrospun filters offer a promising pathway toward high‐efficiency, multifunctional filtration systems applicable to defense, healthcare, and environmental protection.


  • Open Access

    Aerosol tracer testing in Boeing 767 and 777 aircraft to simulate exposure potential of infectious aerosol such as SARS-CoV-2

    by Sean M. Kinahan, David B. Silcott, Blake E. Silcott, Ryan M. Silcott, Peter J. Silcott, Braden J. Silcott, Steven L. Distelhorst, Vicki L. Herrera, Danielle N. Rivera, Kevin K. Crown, et al.

    The COVID-19 pandemic has reintroduced questions regarding the potential risk of SARS-CoV-2 exposure amongst passengers on an aircraft. Quantifying risk with computational fluid dynamics models or contact tracing methods alone is challenging, as experimental results for inflight biological aerosols is lacking. Using fluorescent aerosol tracers and real time optical sensors, coupled with DNA-tagged tracers for aerosol deposition, we executed ground and inflight testing on Boeing 767 and 777 airframes. Analysis here represents tracer particles released from a simulated infected passenger, in multiple rows and seats, to determine the exposure risk via penetration into breathing zones in that row and numerous rows ahead and behind the index case. We present here conclusions from 118 releases of fluorescent tracer particles, with 40+ Instantaneous Biological Analyzer and Collector sensors placed in passenger breathing zones for real-time measurement of simulated virus particle penetration. Results from both airframes showed a minimum reduction of 99.54% of 1 μm aerosols from the index source to the breathing zone of a typical passenger seated directly next to the source. An average 99.97 to 99.98% reduction was measured for the breathing zones tested in the 767 and 777, respectively. Contamination of surfaces from aerosol sources was minimal, and DNA-tagged 3 μm tracer aerosol collection techniques agreed with fluorescent methodologies.


  • Open Access

    Aerosol tracer testing in Boeing 767 and 777 aircraft to simulate exposure potential of infectious aerosol such as SARS-CoV-2

    by Sean M Kinahan, David B Silcott, Blake E Silcott, Ryan M Silcott, Peter J Silcott, Braden J Silcott, Steven L Distelhorst, Vicki L Herrera, Danielle N Rivera, Kevin K Crown, et al.

    The COVID-19 pandemic has reintroduced questions regarding the potential risk of SARS-CoV-2 exposure amongst passengers on an aircraft. Quantifying risk with computational fluid dynamics models or contact tracing methods alone is challenging, as experimental results for inflight biological aerosols is lacking. Using fluorescent aerosol tracers and real time optical sensors, coupled with DNA-tagged tracers for aerosol deposition, we executed ground and inflight testing on Boeing 767 and 777 airframes. Analysis here represents tracer particles released from a simulated infected passenger, in multiple rows and seats, to determine the exposure risk via penetration into breathing zones in that row and numerous rows ahead and behind the index case. We completed over 65 releases of 180,000,000 fluorescent particles from the source, with 40+ Instantaneous Biological Analyzer and Collector sensors placed in passenger breathing zones for real-time measurement of simulated virus particle penetration. Results from both airframes showed a minimum reduction of 99.54% of 1 µm aerosols from the index source to the breathing zone of a typical passenger seated directly next to the source. An average 99.97 to 99.98% reduction was measured for the breathing zones tested in the 767 and 777, respectively. Contamination of surfaces from aerosol sources was minimal, and DNA-tagged 3 µm tracer aerosol collection techniques agreed with fluorescent methodologies.