MDMürüvvet Dayıoğlu

Mürüvvet Dayıoğlu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Mürüvvet Dayıoğlu has a total of 26 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Performance of handheld ultrasound devices in diagnosis of pulmonary hypertension and right heart dysfunction in ICU patients

    by Mürüvvet Dayıoğlu, Gül Gürsel, Seçil Özercan, Eda Macit Aydın, Özge Nadastepe

    Aim: The use of handheld ultrasonography devices (HHUD) has increased recently but there are limited data about their performance in the evaluation of right heart dysfunction (RHD) and pulmonary hypertension (PHT). The aim of the study is to compare the performance of a HHUD with a conventional ultrasound device (CUD) in assessing PHT and RHD.Methods: This single‐center prospective study was performed in a seven‐bed teaching hospital intensive care unit (ICU). PHT and RHD criteria were compared by HHUD and CUD. Additional PHT criteria and right ventricle (RV) systolic and diastolic dysfunction criteria were also measured.Results: Forty‐six patients were included in the study. There was no significant difference between the imaging rates and mean values of the parameters measured by both devices. When the positivity rates for additional PHT parameters and RHD criteria were compared, there were no significant differences between the devices. In Bland‐Altman's analysis, there was good agreement and there was no bias between the measurements of the two devices but left ventricular end‐systolic eccentricity index (LVSEI), right atrium area (RAA), and pulmonary artery diameter (PAD). Ninety percent of the patients had PHT probability, of whom 43% had a low, 37% had intermediate and 10% had a high probability of PHT. Ninety‐two percent of the patients had RHD and there was no significant difference between the devices in the diagnosis of RHD (p = .212). When RV systolic and diastolic dysfunction evaluations of the devices were compared according to the British Society of Echocardiography (BSE) criteria there was no significant difference between the devices’ measurements in the evaluation of systolic and diastolic function.Conclusion: The imaging and measurement capabilities of the HHUDs for PHT and RHD parameters were similar to CUDs, and considering the inconsistent parameters, the HHUD can be useful in diagnosing these problems.


  • Open Access

    Comparison of Calculated and Measured Energy Expenditure Determination Methods

    by Mürüvvet Dayıoğlu, Alper Yosunkaya

    Amaç: Yoğun bakım hastalarında enerji tüketiminin doğru belirlenmesinde indirekt kalorimetri (İK) altın standart olarak kabul edilir. Bu çalışmanın amacı mekanik ventilasyon uygulanan hastalarda ölçülen enerji tüketimini (ÖET), tahmin ettirici eşitliklerle hesaplanan enerji tüketimi (HET) ile karşılaştırmaktır. Gereç ve Yöntem: Bu çalışma tıbbi/cerrahi yoğun bakım ünitemize yatırılan kırk hasta üzerinde yapıldı. İK ile ölçülen 24 saatlik enerji tüketimi ile Harris-Benedict, Schofield, Ireton-Jones ve Swinamer denklemleri kullanılarak aktüel ve düzeltilmiş kilolara göre, düzeltme faktörleri de eklenerek karşılaştırıldı. Bulgular: ÖET'nin ortalaması 2697,9±606,0 kcal/gün olarak bulundu. Eşitlikler kullanılarak hesaplanan tüm HET değerleri ÖET ile koreleydi ve düzeltilmiş kilolar ile korelasyon güçlenmekteydi, bununla birlikte Bland-Altman analizi uyum limitlerinin geniş olduğunu gösterdi. HET’nin ÖET’nin %80 ve %110 arasına tekabül etmesi yeterli beslenme aralığı olarak kabul edildi ve düzeltilmiş vücut ağırlığı ve Long faktörlerinin kullanılması ile en iyi yeterlilik düzeylerini sağladı; ancak en iyi ihtimalde bile hastaların %20’sinin düşük veya yüksek beslenme riski altındaydı. Sonuç: Geniş uyum limitleri nedeniyle mekanik ventilasyon uygulanan yoğun bakım hastalarında enerji tüketimini belirlemede tahmin denklemlerinin güvenilir olmadığı sonucuna varılmıştır. ÖET’nin %80-110’u aralığına giren tahminler de yetersiz beslenme ihtimalini işaret etmektedir. Çalışmamız, beslenme yönetiminin bireysel yaklaşım gerektirdiğini işaret eden çalışmaları desteklemektedir.


  • Open Access

    Evaluation of ultrasound-measured gastric volume and content in type 2 diabetes mellitus patients undergoing elective surgery: a prospective observational study

    by Asiye Demi̇rel, Mürüvvet Dayıoğlu, Ayşe Neslihan Balkaya, Anıl Onur, Füsun Gözen

    Objectives: Delayed gastric emptying create a risk of pulmonary aspiration during anesthesia. We aim to assess the antral cross-sectional area (CSA) and gastric volume using ultrasound techniques and to investigate the relationship between these variables and both the duration and regulation of type 2 diabetes mellitus (DM). Methods: Gastric volume was estimated by measuring the antral CSA in the supine and right lateral decubitus (RLD) positions in 80 patients. The antral content was qualitatively classified according to Perlas et al. (grades 0, 1, and 2), and gastric volume was computed using a previously described formula. The presence of solid content or > 1.5 mL/kg fluid in the stomach was classified as indicative of a full stomach. Results: The mean duration of diabetes among the subjects was 9.4 ± 3.7 years. The mean fasting duration was 10.2 ± 2.1 hours for solids and 2.5 ± 0.7 for liquids. Twelve of the 80 patients exhibited grade 2 stomach. Age (p = 0.005), Body mass index (p = 0.001), solid fasting duration (p = 0.027), and supine and RLD CSA (p < 0.001 for both) were significantly associated with full stomach. A history of ≥8 years of diabetes (p < 0.001) and peripheral neuropathy (p = 0.005) was identified as a risk factor for a full stomach. Conclusions: Despite adherence to standard fasting protocols, 15% of the type 2 DM patients were identified with a 'full stomach' condition. Preoperative ultrasound assessment of gastric contents in patients with type 2 DM, especially with long-standing diabetes (≥ 8 years) and with peripheral neuropathy is recommended. The findings of this study necessitate additional investigation to support the conceptualization of specific guidelines for diabetes to mitigate the risk of pulmonary aspiration.


  • Open Access

    Clinical evaluation of intravenous sedation in pediatric endoscopic procedures: A retrospective observational study

    by Nermin Kilicarslan, Muruvvet Dayioglu, Ayse Neslihan Balkaya, Kaan Demiroren

    Objective: The main benefits of sedation are to reduce the patient’s anxiety and discomfort, to improve their tolerability. The aim of study was evaluate intravenous sedation for pediatric gastrointestinal endoscopic procedures Materials and Methods: We analyzed patients’ data, who underwent gastrointestinal endoscopic procedures in our pediatric endoscopy unit, retrospectively. All gastrointestinal endoscopic procedures were performed by a pediatric gastroenterologist and sedations were managed by an anaesthesia team, including two staff anesthesiologists. Results: During the study period, 530 gastrointestinal endoscopic procedures were performed. 461 (87%) were esophagogastroduodenoscopy, 56 (10.6%) were both esophagogastroduodenoscopy and colonoscopy and 13 (2.5%) were percutaneous endoscopic gastrostomy. Propofol was given all of the patients either as a single drug (6 patients, 1%) or in combinations (77.4% with midazolam; 12.3% with ketamine and 9.2% with fentanyl). Overall adverse event rate due to sedation was 19.6%, but no serious side effects were documented. The most frequent side effects were injection pain (10.4%), and nausea (7.5%). Allergic reactions were experienced in 1.3% patients and resolved with methylprednisolone and antihistaminic medications. Respiratory depression was observed in only two girls (3 and17 years old) and did not need advanced interventions to control the problem. Seven patients’ gastroscopies were interrupted by gastroenterologist due to gastric content in order to prevent vomiting and aspiration. Conclusions: Intravenous sedation for pediatric gastrointestinal endoscopic procedures can be applied safely and successfully with a trained team and organized endoscopy unit.


  • Our Experience in Anesthesia Management in Operations for Congenital Pediatric Cardiac Diseases

    by Buket Özyaprak, Filiz Ata, Mürüvvet Dayıoğlu, Kurtbey Anarat, Mehmet Kaydul, Yılmaz Apaydın, Mehmet Gamlı, Ümran Karaca, Serkan Seçici, Cüneyt Eriş, et al.