Rudra Pratap
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Rudra Pratap has a total of 108 co-authors. Here are the top co-authors by number of shared publications:
- Kaustav Roy
Centre for Nanoscience and Engineering, Indian Institute of Science 1 , Bengaluru 560012
8 shared publications - Sudhanshu Tiwari
OxideMEMS Lab, Elmore Family School of Electrical and Computer Engineering, Purdue University, West Lafayette, USA
6 shared publications Anuj Ashok
Centre for Nanoscience and Engineering Indian Institute of Science - 560012 Bengaluru India
5 shared publicationsVijayendra Shastri
Center for Nanoscience and Engineering, Indian Institute of Science, Bangalore 560012, India
5 shared publications- Antony Jeyaseelan
Materials Science Division, CSIR-National Aerospace Laboratories, Bangalore—560017, India
4 shared publications - Anuj Ashok
Centre for Nanoscience and Engineering, Indian Institute of Science 1 , Bengaluru 560012
4 shared publications
Latest Publications
- 1 October 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 26 (20) , 30450-30462
Multimode Resonant Pressure Sensor With High Sensitivity and Wide Operating Range
- 1 October 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 26 (20) , 30450-30462
Multimode Resonant Pressure Sensor With High Sensitivity and Wide Operating Range
- 7 November 2025
- Published by Elsevier in Biomaterials
- Vol. 328, 123844
Selective killing of cancer-associated fibroblasts by ultrasound-mediated mechanical forces
- 7 November 2025
- Published by Elsevier in Biomaterials
- Vol. 328, 123844
Selective killing of cancer-associated fibroblasts by ultrasound-mediated mechanical forces
- 18 April 2025
- Published by AIP Publishing in Applied Physics Reviews
- Vol. 12 (2)
Boosting quality factor of resonant sensors in fluids
Micro-mechanical resonators are widely used in modern sensing technology due to their high-quality factor (Q), enabling sensitive detection of various stimuli. However, the performance of these resonators in fluid environments is limited by significant viscous and acoustic radiation losses that reduce their Q. Here, we present a paradigm-shifting discovery that challenges the conventional wisdom of resonant sensing in fluids. We report an optimal volume of fluid over a 2D micro-resonator that increases the Q by up to 1000% compared to that in air. We have conducted precise experiments on piezoelectric, circular, membrane-type micro-resonators of 4 mm diameter fabricated using microelectromechanical systems technology on silicon-on-insulator wafers. The top side of the resonator was filled with different volumes of a fluid, i.e., fluidically loading only on one side of the membrane rather than entirely immersing the device, and its Q was measured through resonance tracking by actuating the resonator with an appropriate voltage. We found the existence of an optimal volume of fluid that maximized the Q. We argue that this phenomenon is a result of a balance between the enhancement of kinetic energy of the resonator due to mass loading of the fluid and the energy dissipation through viscous and acoustic radiation losses in the fluid medium. This remarkable enhancement in Q substantially improves the sensitivity of the resonator, with important implications for diverse applications such as biosensing and chemical detection. Our findings challenge the prevailing understanding of resonant sensing in fluids, providing new avenues for the development of highly sensitive sensors.
- 18 April 2025
- Published by AIP Publishing in Applied Physics Reviews
- Vol. 12 (2)
Boosting quality factor of resonant sensors in fluids
Micro-mechanical resonators are widely used in modern sensing technology due to their high-quality factor (Q), enabling sensitive detection of various stimuli. However, the performance of these resonators in fluid environments is limited by significant viscous and acoustic radiation losses that reduce their Q. Here, we present a paradigm-shifting discovery that challenges the conventional wisdom of resonant sensing in fluids. We report an optimal volume of fluid over a 2D micro-resonator that increases the Q by up to 1000% compared to that in air. We have conducted precise experiments on piezoelectric, circular, membrane-type micro-resonators of 4 mm diameter fabricated using microelectromechanical systems technology on silicon-on-insulator wafers. The top side of the resonator was filled with different volumes of a fluid, i.e., fluidically loading only on one side of the membrane rather than entirely immersing the device, and its Q was measured through resonance tracking by actuating the resonator with an appropriate voltage. We found the existence of an optimal volume of fluid that maximized the Q. We argue that this phenomenon is a result of a balance between the enhancement of kinetic energy of the resonator due to mass loading of the fluid and the energy dissipation through viscous and acoustic radiation losses in the fluid medium. This remarkable enhancement in Q substantially improves the sensitivity of the resonator, with important implications for diverse applications such as biosensing and chemical detection. Our findings challenge the prevailing understanding of resonant sensing in fluids, providing new avenues for the development of highly sensitive sensors.
- 4 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Microelectromechanical Systems
- Vol. 33 (6) , 793-805
Synchronized Opto-Electro-Mechanical Measurements for Estimation of Energy Dissipation in Thin-Film-Piezoelectricon-Substrate MEMS/NEMS Devices
Piezoelectric microelectromechanical systems have significant market potential owing to their superior capabilities of transduction to those of standard capacitive and piezoresistive devices. However, piezoelectric films are often lossy, which reduces the Quality Factor of devices and affects their performance. It is thus important to examine all sources of energy dissipation in such devices and accurately determine them based on experimental data. Currently used methods to quantify energy dissipation from different sources and the properties of materials based on experimental data are set-up for piezoelectric devices, in which energy storage and dissipation primarily occur in the same piezoelectric material. Moreover, such methods rely on resonance-antiresonance measurements, and thus are unsuitable for thin-film-piezoelectric-on-substrate (TPoS) Micro/Nano devices that have i) a significant portion of energy stored in the substrate/device layer, ii) a low signal-to-noise ratio owing to either lossy piezoelectric films or high motional impedance, or iii) a larger feedthrough capacitance, arising primarily from collocated electrodes, in addition to the internal capacitance of the piezoelectric film. In this paper, we propose a method that overcomes these challenges based on synchronized optical and electrical measurements. We develop a comprehensive physics-based model to extract all the relevant parameters for the device, including the coefficient of piezoelectric coupling, internal and feedthrough capacitance, loss tangents (dielectric, piezoelectric, and mechanical), and the contributions of different sources to the Quality Factor of the device. We showcase the proposed method by using a PZT-based TPoS MEMS cantilever and a Piezoelectric Micromachined Ultrasonic Transducers (PMUT). 2024-0063
- 4 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Microelectromechanical Systems
- Vol. 33 (6) , 793-805
Synchronized Opto-Electro-Mechanical Measurements for Estimation of Energy Dissipation in Thin-Film-Piezoelectricon-Substrate MEMS/NEMS Devices
Piezoelectric microelectromechanical systems have significant market potential owing to their superior capabilities of transduction to those of standard capacitive and piezoresistive devices. However, piezoelectric films are often lossy, which reduces the Quality Factor of devices and affects their performance. It is thus important to examine all sources of energy dissipation in such devices and accurately determine them based on experimental data. Currently used methods to quantify energy dissipation from different sources and the properties of materials based on experimental data are set-up for piezoelectric devices, in which energy storage and dissipation primarily occur in the same piezoelectric material. Moreover, such methods rely on resonance-antiresonance measurements, and thus are unsuitable for thin-film-piezoelectric-on-substrate (TPoS) Micro/Nano devices that have i) a significant portion of energy stored in the substrate/device layer, ii) a low signal-to-noise ratio owing to either lossy piezoelectric films or high motional impedance, or iii) a larger feedthrough capacitance, arising primarily from collocated electrodes, in addition to the internal capacitance of the piezoelectric film. In this paper, we propose a method that overcomes these challenges based on synchronized optical and electrical measurements. We develop a comprehensive physics-based model to extract all the relevant parameters for the device, including the coefficient of piezoelectric coupling, internal and feedthrough capacitance, loss tangents (dielectric, piezoelectric, and mechanical), and the contributions of different sources to the Quality Factor of the device. We showcase the proposed method by using a PZT-based TPoS MEMS cantilever and a Piezoelectric Micromachined Ultrasonic Transducers (PMUT). 2024-0063
- 23 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-8
PMUT-Powered Photoacoustic Detection: Revolutionizing Microfluidic Concentration Measurements
This report introduces a novel optofluidic platform based on piezo-MEMS technology, capable of identifying subtle variations in the fluid concentration. The system utilizes piezoelectric micromachined ultrasound transducers (PMUTs) as receivers to capture sound waves produced by nanosecond photoacoustic (PA) pulses emanating from a fluid target housed in PDMS microchannels. Additionally, a dedicated low-noise single-channel amplifier has been developed to extract the minute analog voltage signals from the PMUTs, given the inherently weak ultrasound signals generated by fluid targets. The PMUTs’ proficiency in detecting changes in fluid concentration under both static and time-varying conditions has been documented and verified, confirming the platform’s efficacy in monitoring fluid concentrations.
- 23 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-8
PMUT-Powered Photoacoustic Detection: Revolutionizing Microfluidic Concentration Measurements
This report introduces a novel optofluidic platform based on piezo-MEMS technology, capable of identifying subtle variations in the fluid concentration. The system utilizes piezoelectric micromachined ultrasound transducers (PMUTs) as receivers to capture sound waves produced by nanosecond photoacoustic (PA) pulses emanating from a fluid target housed in PDMS microchannels. Additionally, a dedicated low-noise single-channel amplifier has been developed to extract the minute analog voltage signals from the PMUTs, given the inherently weak ultrasound signals generated by fluid targets. The PMUTs’ proficiency in detecting changes in fluid concentration under both static and time-varying conditions has been documented and verified, confirming the platform’s efficacy in monitoring fluid concentrations.
- 24 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Letters
- Vol. 8 (3) , 1-4
Photoacoustic Imaging With Single-Element, Low-Frequency Thin-Film PMUT
For the first time, we present photoacoustic (PA) imaging using a single-element (single-cell) piezoelectric micromachined ultrasound transducer (PMUT) with a low resonant frequency of approximately 1 MHz and a compact effective aperture as tiny as 0.06 mm $^{2}$ . Adding to this innovation, we introduce pioneering image enhancement techniques applied directly to images obtained from this standalone single-cell PMUT, aiming to elevate and refine PA image quality. Our approach employs a trio of advanced methods: 1) frame averaging to ensure clarity by reducing image clutter; 2) cutting-edge mathematical algorithms to fine-tune image quality metrics; and 3) precise hardware positioning for accurate image capture. These techniques underwent rigorous validation using both agar phantom and ex-vivo tissue samples. As benchmarks for our progress, we utilized quantifiers including full width at half maximum (FWHM), signal-to-noise ratio (SNR), and contrast ratio (CR). Our results were striking: a 34% improvement in FWHM, a 23% boost in SNR, and a 25% enhancement in CR. These numbers clearly demonstrate the efficacy of our methods in optimizing PA images through a low-frequency PMUT-based detector. In conclusion, our research indicates that these enhancement methods could be instrumental in shaping a cost-effective and efficient future for PMUT-based photoacoustic imaging (PAI) systems.
- 24 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Letters
- Vol. 8 (3) , 1-4
Photoacoustic Imaging With Single-Element, Low-Frequency Thin-Film PMUT
For the first time, we present photoacoustic (PA) imaging using a single-element (single-cell) piezoelectric micromachined ultrasound transducer (PMUT) with a low resonant frequency of approximately 1 MHz and a compact effective aperture as tiny as 0.06 mm $^{2}$ . Adding to this innovation, we introduce pioneering image enhancement techniques applied directly to images obtained from this standalone single-cell PMUT, aiming to elevate and refine PA image quality. Our approach employs a trio of advanced methods: 1) frame averaging to ensure clarity by reducing image clutter; 2) cutting-edge mathematical algorithms to fine-tune image quality metrics; and 3) precise hardware positioning for accurate image capture. These techniques underwent rigorous validation using both agar phantom and ex-vivo tissue samples. As benchmarks for our progress, we utilized quantifiers including full width at half maximum (FWHM), signal-to-noise ratio (SNR), and contrast ratio (CR). Our results were striking: a 34% improvement in FWHM, a 23% boost in SNR, and a 25% enhancement in CR. These numbers clearly demonstrate the efficacy of our methods in optimizing PA images through a low-frequency PMUT-based detector. In conclusion, our research indicates that these enhancement methods could be instrumental in shaping a cost-effective and efficient future for PMUT-based photoacoustic imaging (PAI) systems.
- 27 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (4) , 4380-4386
Low-Cost Scalable PCB-Based 2-D Transducer Arrays for Volumetric Photoacoustic Imaging
Photoacoustic (PA) imaging provides deep tissue molecular imaging of chromophores with optical absorption contrast and ultrasonic resolution. Present PA imaging techniques are predominantly limited to one 2-D plane per acquisition. The 2-D ultrasound (US) transducers, required for real-time 3-D PA imaging, are high cost, complex to fabricate, and have limited scalability in design. We present novel printed circuit board (PCB)-based 2-D matrix US transducer arrays that are capable of being bulk manufactured at low cost without using laborious US fabrication tools. The 2-D US array specifications are easily scalable with respect to widely available PCB design tools. To demonstrate scalability, we fabricated low-frequency (11 MHz) $8\times8$ matrix array and high-frequency (40 MHz) $4\times4$ matrix array by directly bonding an undiced polyvinylidene difluoride (PVDF) piezoelectric material of desired thickness to the custom designed PCB substrate. Characterization results demonstrate wideband PA receive sensitivity for both the low-frequency (6-dB bandwidth: 87%) and the high-frequency (6-dB bandwidth: 188%) arrays. Volumetric PA imaging results of light-absorbing targets inside optical scattering medium demonstrate improved spatial resolution and field of view (FOV) with an increase in aperture size.
- 27 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (4) , 4380-4386
Low-Cost Scalable PCB-Based 2-D Transducer Arrays for Volumetric Photoacoustic Imaging
Photoacoustic (PA) imaging provides deep tissue molecular imaging of chromophores with optical absorption contrast and ultrasonic resolution. Present PA imaging techniques are predominantly limited to one 2-D plane per acquisition. The 2-D ultrasound (US) transducers, required for real-time 3-D PA imaging, are high cost, complex to fabricate, and have limited scalability in design. We present novel printed circuit board (PCB)-based 2-D matrix US transducer arrays that are capable of being bulk manufactured at low cost without using laborious US fabrication tools. The 2-D US array specifications are easily scalable with respect to widely available PCB design tools. To demonstrate scalability, we fabricated low-frequency (11 MHz) $8\times8$ matrix array and high-frequency (40 MHz) $4\times4$ matrix array by directly bonding an undiced polyvinylidene difluoride (PVDF) piezoelectric material of desired thickness to the custom designed PCB substrate. Characterization results demonstrate wideband PA receive sensitivity for both the low-frequency (6-dB bandwidth: 87%) and the high-frequency (6-dB bandwidth: 188%) arrays. Volumetric PA imaging results of light-absorbing targets inside optical scattering medium demonstrate improved spatial resolution and field of view (FOV) with an increase in aperture size.
- Open Access
Boosting Resonant Sensing in Fluids: A Surprising Discovery
Micro-mechanical resonators are widely used in modern sensing technology due to their high quality-factor (Q), enabling sensitive detection of various stimuli. However, the performance of these resonators in fluid environments is limited by significant viscous and acoustic radiation losses that reduce their Q. Here, we present a paradigm-shifting discovery that challenges the conventional wisdom of resonant sensing in fluids. We report an optimal volume of fluid over a 2D micro-resonator that increases the Q by up to 1000% compared to that in air. We have conducted precise experiments on piezoelectric, circular, membrane-type micro-resonators of 4 mm diameter fabricated using MEMS technology on silicon-on-insulator (SOI) wafers. The top side of the resonator was filled with different volumes of fluid and its Q was measured through resonance tracking by actuating the resonator with an appropriate voltage. We found the existence of an optimal volume of fluid that maximized the Q. We argue that this phenomenon is a result of a balance between the enhancement of kinetic energy of the resonator due to mass loading of the fluid and the energy dissipation through viscous and acoustic radiation losses in the fluid medium. This remarkable enhancement in Q substantially improves the sensitivity of the resonator, with important implications for diverse applications such as biosensing, chemical detection, and environmental monitoring. Our findings challenge the prevailing understanding of resonant sensing in fluids and open up new avenues for the development of highly sensitive and accurate sensors.
Open AccessBoosting Resonant Sensing in Fluids: A Surprising Discovery
Micro-mechanical resonators are widely used in modern sensing technology due to their high quality-factor (Q), enabling sensitive detection of various stimuli. However, the performance of these resonators in fluid environments is limited by significant viscous and acoustic radiation losses that reduce their Q. Here, we present a paradigm-shifting discovery that challenges the conventional wisdom of resonant sensing in fluids. We report an optimal volume of fluid over a 2D micro-resonator that increases the Q by up to 1000% compared to that in air. We have conducted precise experiments on piezoelectric, circular, membrane-type micro-resonators of 4 mm diameter fabricated using MEMS technology on silicon-on-insulator (SOI) wafers. The top side of the resonator was filled with different volumes of fluid and its Q was measured through resonance tracking by actuating the resonator with an appropriate voltage. We found the existence of an optimal volume of fluid that maximized the Q. We argue that this phenomenon is a result of a balance between the enhancement of kinetic energy of the resonator due to mass loading of the fluid and the energy dissipation through viscous and acoustic radiation losses in the fluid medium. This remarkable enhancement in Q substantially improves the sensitivity of the resonator, with important implications for diverse applications such as biosensing, chemical detection, and environmental monitoring. Our findings challenge the prevailing understanding of resonant sensing in fluids and open up new avenues for the development of highly sensitive and accurate sensors.
- Open Access
- 29 November 2023
- Published by IOP Publishing in Journal of Micromechanics and Microengineering
- Vol. 34 (1) , 013001
MEMS audio speakers *
Miniaturization of electro-mechanical sensors and actuators has benefited from an advancement in CMOS technology over the years. However, miniaturization of audio speakers has seen considerable development only in the recent times. This paper reviews the developments in micro-electro-mechanical-systems (MEMS) audio speaker research and the initial commercial products available in the market. At first glance, it appears that the relatively slow development of MEMS speakers can be attributed to the fact that the principle of actuation has remained unchanged for several decades. Unfortunately, the physics behind audible sound production holds us back from exclusively adopting miniaturized speakers—sound pressure level is directly proportional to the area of the sound radiating surface. Nevertheless, researchers are continuing to explore new avenues for designing and developing MEMS speakers, without limiting themselves to the existing actuation principles. With newly discovered materials and improving technology, the research in MEMS speakers is gaining attention and new products are emerging. A speaker design based on piezoelectric actuation or electrostatics actuation is favorable at MEMS scale. Indian research community is also contributing to advances in MEMS speakers and near-ultrasonic devices. This paper reviews the development in MEMS audio speakers in India and in the world. The tabulated review findings aim to offer readers an overview of the development of micro-speakers and to provide guidance for designing new micro-speakers.
- 29 November 2023
- Published by IOP Publishing in Journal of Micromechanics and Microengineering
- Vol. 34 (1) , 013001
Open AccessMEMS audio speakers *
Miniaturization of electro-mechanical sensors and actuators has benefited from an advancement in CMOS technology over the years. However, miniaturization of audio speakers has seen considerable development only in the recent times. This paper reviews the developments in micro-electro-mechanical-systems (MEMS) audio speaker research and the initial commercial products available in the market. At first glance, it appears that the relatively slow development of MEMS speakers can be attributed to the fact that the principle of actuation has remained unchanged for several decades. Unfortunately, the physics behind audible sound production holds us back from exclusively adopting miniaturized speakers—sound pressure level is directly proportional to the area of the sound radiating surface. Nevertheless, researchers are continuing to explore new avenues for designing and developing MEMS speakers, without limiting themselves to the existing actuation principles. With newly discovered materials and improving technology, the research in MEMS speakers is gaining attention and new products are emerging. A speaker design based on piezoelectric actuation or electrostatics actuation is favorable at MEMS scale. Indian research community is also contributing to advances in MEMS speakers and near-ultrasonic devices. This paper reviews the development in MEMS audio speakers in India and in the world. The tabulated review findings aim to offer readers an overview of the development of micro-speakers and to provide guidance for designing new micro-speakers.
- 19 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Letters
- Vol. 7 (12) , 1-4
Ultrasensitive Pressure Sensor Based on an Integrated Circular Piezoelectric MEMS Resonator and Diaphragm Structure
In this letter, we report an ultrasensitive pressure sensor based on an integrated circular piezoelectric microelectromechanical resonator and stainless-steel diaphragm structure. Finite element analysis is conducted to validate the working principle of the sensor, identify modes with high-pressure sensitivity and estimate the resonance frequency drift. The sensor operates on the principle of frequency shift caused by the coupling between the applied pressure and stress of the resonator. The high electromechanical coupling coefficient of Lead Zirconate Titanate facilitates seamless transduction between the physical domains of interest. The sensitivity of the sensor is 31, 711 ppm/bar and 14, 600 ppm/bar for the first and second flexural modes with nonlinearity of 2.2% full-scale (FS) and 0.84%FS, respectively, in the operating range of 0-5 bar at room temperature. The sensor exhibits excellent repeatability for multiple bidirectional pressure sweep. The proof of concept demonstrated in this letter will enable miniaturization and batch fabrication of pressure sensors with high sensitivity and bandwidth of operation.
- 19 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Letters
- Vol. 7 (12) , 1-4
Ultrasensitive Pressure Sensor Based on an Integrated Circular Piezoelectric MEMS Resonator and Diaphragm Structure
In this letter, we report an ultrasensitive pressure sensor based on an integrated circular piezoelectric microelectromechanical resonator and stainless-steel diaphragm structure. Finite element analysis is conducted to validate the working principle of the sensor, identify modes with high-pressure sensitivity and estimate the resonance frequency drift. The sensor operates on the principle of frequency shift caused by the coupling between the applied pressure and stress of the resonator. The high electromechanical coupling coefficient of Lead Zirconate Titanate facilitates seamless transduction between the physical domains of interest. The sensitivity of the sensor is 31, 711 ppm/bar and 14, 600 ppm/bar for the first and second flexural modes with nonlinearity of 2.2% full-scale (FS) and 0.84%FS, respectively, in the operating range of 0-5 bar at room temperature. The sensor exhibits excellent repeatability for multiple bidirectional pressure sweep. The proof of concept demonstrated in this letter will enable miniaturization and batch fabrication of pressure sensors with high sensitivity and bandwidth of operation.