Andrea Ianni
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Andrea Ianni has a total of 58 co-authors. Here are the top co-authors by number of shared publications:
- Aldo Ianni
INFN Laboratori Nazionali del Gran Sasso, Via Giovanni Acitelli, 22, 67100 Assergi (AQ)
2 shared publications - Cristiano Galbiati
Princeton University
2 shared publications - Davide Franco
Université de Paris Cité
2 shared publications - Gemma Testera
Istituto Nazionale di Fisica Nucleare Sezione di Genova 16146 Genova Italy
2 shared publications - Giuliana Fiorillo
Istituto Nazionale Di Fisica Nucleare Sezione Di Napoli
2 shared publications - Marco Razeti
Istituto Nazionale di Fisica Nucleare Sezione di Cagliari 09042 Cagliari Italy
2 shared publications
Latest Publications
- 18 March 2022
- Published by ASME International in Journal of Fluids Engineering
- Vol. 144 (8)
Natural Convection and Transport of Background Contamination in the Borexino Neutrino Detector
The Borexino detector at Gran Sasso National Laboratories (INFN) has obtained extraordinary achievements for solar neutrino and geoneutrino physics during its lifetime. More recently, Borexino has provided the first experimental evidence of the subdominant CNO solar neutrino flux thanks to an outstanding low background level obtained by means of intense purification campaigns and a continuous improvement of the detector thermal stabilization over the years. In particular, this impressive thermal steadiness has led to a progressive mitigation of the internal convective currents which are responsible for the continuous background contamination of the detector sensitive inner volume. To this purpose, numerical analyses are essential to better comprehend the detector fluid dynamics, the background behavior, and are also important to propose effective countermeasures to further reduce natural convection inside the detector. In this framework, the present work investigates the flow characteristics of the liquid scintillator by means of computational fluid dynamics analyses. In particular, a full 3D model of the Borexino inner vessel is considered in the simulations, addressing the complex nature of the natural convective currents under consideration both in transient and stationary conditions. The calculated flow pattern has been adopted to predict the transport behavior of 210Po, that is fundamental for the independent constraint of 210Bi, the main background constituent affecting CNO measurement. The convection-diffusion analysis demonstrates the applicability of the adopted methodology showing a good agreement between calculation and experimental data.
- 18 March 2022
- Published by ASME International in Journal of Fluids Engineering
- Vol. 144 (8)
Natural Convection and Transport of Background Contamination in the Borexino Neutrino Detector
The Borexino detector at Gran Sasso National Laboratories (INFN) has obtained extraordinary achievements for solar neutrino and geoneutrino physics during its lifetime. More recently, Borexino has provided the first experimental evidence of the subdominant CNO solar neutrino flux thanks to an outstanding low background level obtained by means of intense purification campaigns and a continuous improvement of the detector thermal stabilization over the years. In particular, this impressive thermal steadiness has led to a progressive mitigation of the internal convective currents which are responsible for the continuous background contamination of the detector sensitive inner volume. To this purpose, numerical analyses are essential to better comprehend the detector fluid dynamics, the background behavior, and are also important to propose effective countermeasures to further reduce natural convection inside the detector. In this framework, the present work investigates the flow characteristics of the liquid scintillator by means of computational fluid dynamics analyses. In particular, a full 3D model of the Borexino inner vessel is considered in the simulations, addressing the complex nature of the natural convective currents under consideration both in transient and stationary conditions. The calculated flow pattern has been adopted to predict the transport behavior of 210Po, that is fundamental for the independent constraint of 210Bi, the main background constituent affecting CNO measurement. The convection-diffusion analysis demonstrates the applicability of the adopted methodology showing a good agreement between calculation and experimental data.
- Open Access
Mechanical Ventilator Milano (MVM): A Novel Mechanical Ventilator Designed for Mass Scale Production in Response to the COVID-19 Pandemics
We present here the design of the Mechanical Ventilator Milano (MVM), a novel mechanical ventilator designed for mass scale production in response to the COVID-19 pandemics, to compensate for the dramatic shortage of such ventilators in many countries. This ventilator is an electro-mechanical equivalent of the old, reliable Manley Ventilator. Our design is optimized to permit large sale production in short time and at a limited cost, relying on off-the-shelf components, readily available worldwide from hardware suppliers. Operation of the MVM requires only a source of compressed oxygen (or compressed medical air) and electrical power. The MVM control and monitoring unit can be connected and networked via WiFi so that no additional electrical connections are necessary other than the connection to the electrical power. At this stage the MVM is not a certified medical device. Construction of the first prototypes is starting with a team of engineers, scientists and computing experts. The purpose of this paper is to disseminate the conceptual design of the MVM broadly and to solicit feed-back from the scientific and medical community to speed the process of review, improvement and possible implementation.
Open AccessMechanical Ventilator Milano (MVM): A Novel Mechanical Ventilator Designed for Mass Scale Production in Response to the COVID-19 Pandemics
We present here the design of the Mechanical Ventilator Milano (MVM), a novel mechanical ventilator designed for mass scale production in response to the COVID-19 pandemics, to compensate for the dramatic shortage of such ventilators in many countries. This ventilator is an electro-mechanical equivalent of the old, reliable Manley Ventilator. Our design is optimized to permit large sale production in short time and at a limited cost, relying on off-the-shelf components, readily available worldwide from hardware suppliers. Operation of the MVM requires only a source of compressed oxygen (or compressed medical air) and electrical power. The MVM control and monitoring unit can be connected and networked via WiFi so that no additional electrical connections are necessary other than the connection to the electrical power. At this stage the MVM is not a certified medical device. Construction of the first prototypes is starting with a team of engineers, scientists and computing experts. The purpose of this paper is to disseminate the conceptual design of the MVM broadly and to solicit feed-back from the scientific and medical community to speed the process of review, improvement and possible implementation.
- Open Access
Solar neutrino detection in a large volume double-phase liquid argon experiment
Precision measurements of solar neutrinos emitted by specific nuclear reaction chains in the Sun are of great interest for developing an improved understanding of star formation and evolution. Given the expected neutrino fluxes and known detection reactions, such measurements require detectors capable of collecting neutrino-electron scattering data in exposures on the order of 1 ktonne yr, with good energy resolution and extremely low background. Two-phase liquid argon time projection chambers (LAr TPCs) are under development for direct Dark Matter WIMP searches, which possess very large sensitive mass, high scintillation light yield, good energy resolution, and good spatial resolution in all three cartesian directions. While enabling Dark Matter searches with sensitivity extending to the "neutrino floor" (given by the rate of nuclear recoil events from solar neutrino coherent scattering), such detectors could also enable precision measurements of solar neutrino fluxes using the neutrino-electron elastic scattering events. Modeling results are presented for the cosmogenic and radiogenic backgrounds affecting solar neutrino detection in a 300 tonne (100 tonne fiducial) LAr TPC operating at LNGS depth (3,800 meters of water equivalent). The results show that such a detector could measure the CNO neutrino rate with ~15% precision, and significantly improve the precision of the 7Be and pep neutrino rates compared to the currently available results from the Borexino organic liquid scintillator detector.
Open AccessSolar neutrino detection in a large volume double-phase liquid argon experiment
Precision measurements of solar neutrinos emitted by specific nuclear reaction chains in the Sun are of great interest for developing an improved understanding of star formation and evolution. Given the expected neutrino fluxes and known detection reactions, such measurements require detectors capable of collecting neutrino-electron scattering data in exposures on the order of 1 ktonne yr, with good energy resolution and extremely low background. Two-phase liquid argon time projection chambers (LAr TPCs) are under development for direct Dark Matter WIMP searches, which possess very large sensitive mass, high scintillation light yield, good energy resolution, and good spatial resolution in all three cartesian directions. While enabling Dark Matter searches with sensitivity extending to the "neutrino floor" (given by the rate of nuclear recoil events from solar neutrino coherent scattering), such detectors could also enable precision measurements of solar neutrino fluxes using the neutrino-electron elastic scattering events. Modeling results are presented for the cosmogenic and radiogenic backgrounds affecting solar neutrino detection in a 300 tonne (100 tonne fiducial) LAr TPC operating at LNGS depth (3,800 meters of water equivalent). The results show that such a detector could measure the CNO neutrino rate with ~15% precision, and significantly improve the precision of the 7Be and pep neutrino rates compared to the currently available results from the Borexino organic liquid scintillator detector.