JKJunhoi Kim

Junhoi Kim

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Junhoi Kim has a total of 17 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Laser-Assisted Recovery of On-Chip Phage Viral DNA for Phage Fluorescence Immunoassay Microchip

    by Seohee Chang, Soohyun Kim, Daewon Lee, Seung Ah Lee, Junho Chung, Sunghoon Kwon, Junhoi Kim


  • Open Access

    A High-Throughput Single-Clone Phage Fluorescence Microwell Immunoassay and Laser-Driven Clonal Retrieval System

    by Seohee Chang, Soohyun Kim, Jerome Han, Suji Ha, Hyunho Lee, Seo Woo Song, Daewon Lee, Sunghoon Kwon, Junho Chung, Junhoi Kim

    Phage display is one of the most frequently used platform technologies utilized to screen and select therapeutic antibodies, and has contributed to the development of more than 10 therapeutic antibodies used in the clinic. Despite advantages like efficiency and low cost, it has intrinsic technical limitations, such as the asymmetrical amplification of the library after each round of biopanning, which is regarded as a reason for it yielding a very limited number of antigen binders. In this study, we developed a high-throughput single-clonal screening system comprised of fluorescence immunoassays and a laser-driven clonal DNA retrieval system using microchip technology. Using this system, from a single-chain variable fragment (scFv) library displayed on phages with a complexity of 5.21 × 105 harboring random mutations at five amino acid residues, more than 70,000 clones—corresponding to ~14% of the library complexity—were screened, resulting in 78 antigen-reactive scFv sequences with mutations restricted to the randomized residues. Our results demonstrate that this system can significantly reduce the number of biopanning rounds, or even eliminate the need for this process for libraries with lower complexity, providing an opportunity to obtain more diverse clones from the library.


  • Potentiometric Multichannel Cytometer Microchip for High-throughput Microdispersion Analysis

    by Junhoi Kim, Eun-Geun Kim, Sangwook Bae, Sunghoon Kwon, Honggu Chun

    The parallelization of microfluidic cytometry is expected to lead to considerably enhanced throughput enabling point-of-care diagnosis. In this article, the development of a microfluidic potentiometric multichannel cytometer is presented. Parallelized microfluidic channels sharing a fluid path inevitably suffer from interchannel signal crosstalk that results from electrical coupling within the microfluidic channel network. By employing three planar electrodes within a single detection channel, we electrically decoupled each channel unit, thereby enabling parallel analysis by using a single cytometer microchip with multiple microfluidic channels. The triple-electrode configuration is validated by analyzing the size and concentration of polystyrene microbeads (diameters: 1.99, 2.58, 3, and 3.68 μm; concentration range: ∼2 × 10(5) mL(-1) to ∼1 × 10(7) mL(-1)) and bacterial microdispersion samples (Bacillus subtilis, concentration range: ∼4 × 10(5) CFU mL(-1) to ∼3 × 10(6) CFU mL(-1)). Crosstalk-free parallelized analysis is then demonstrated using a 16-channel potentiometric cytometer (maximum cross-correlation coefficients |r|: < 0.13 in all channel combinations). A detection throughput of ∼48,000 s(-1) was achieved; the throughout can be easily increased with the degree of parallelism of a single microchip without additional technical complexities. Therefore, this methodology should enable high-throughput and low-cost cytometry.