PPPhilip von Platen

Philip von Platen

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Philip von Platen has a total of 35 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Structured robust control for a hybrid functional electrical stimulation exoskeleton system with uncertain dynamics

    by Chenglin Lyu, Fábio Silva Andrade, Marlon Nievenheim, Philip von Platen, L. Cornelius Bollheimer, Steffen Leonhardt, Marian Walter

  • Enhancing Gait Analysis and Pathway Classification Through Ground Impedance-Based Shoes: An Innovative Approach

    by Shubhanshu Sharma, Boby George, Chenglin Lyu, Philip von Platen, Markus Lüken, Marian Walter, L. Cornelius Bollheimer, Steffen Leonhardt

    The type of walking pathway influences gait. Thus a wearable gait sensing technique is important for continuous gait analysis. However, most of the wearable sensing technologies employed in gait analysis solely provide data on gait parameters and do not have mechanisms to sense and account for the type of pathways. In this paper, a novel technique is developed to simultaneously identify some of the spatiotemporal gait parameters and the type of pathway on which the subject is walking. This is achieved by measuring the electrical impedance of the floor between the shoes employing a measurement system reported recently. This paper shows that gait parameters can be derived using the impedance values measured between the shoes. These impedance values change as the legs move, primarily due to changes in capacitance between the shoe and the pathway. A suitable algorithm is developed and tested to estimate the gait parameters and walking speed from the developed prototype, and this is compared with the parameters obtained from reference force plate-based sensing. The testing is done on seven human subjects. The average root mean square error values for different gait parameters were found to be 0.02 s, 1.4 cm, 2.6 cm, 0.07 s, 0.8 steps/min, 2.24 % and 2.24 %, for stride time, stride length, step length, step time, cadence, stance phase, swing phase, respectively and a worst-case error of ±5 % in walking speed is observed. Further, the human subjects walked on different pedestrian pathways. Different features were extracted from the impedance waveform, which helped in successfully classifying all the six types of pathways we tested.

  • Fatigue Assessment and Control With Lower Limb Exoskeletons

    by Lukas Bergmann, Lea Hansmann, Philip von Platen, Steffen Leonhardt, Chuong Ngo

    Acknowledging the vital importance of fatigue management for improving rehabilitation results, customizing treatment, safeguarding patient well-being, and enhancing the quality of life of hemiplegic patients, this study presents the development of a tailored fatigue model and a corresponding human-in-the-loop (HiL) control system for exoskeleton-assisted walking. For this, the selected three-compartment controller fatigue model including a resting recovery parameter was adapted to a dynamic walking task scenario, incorporating a torque–velocity–angle dependency to quantify muscle activity. The model parameters were experimentally verified in a study with six healthy subjects, demonstrating accurate prediction of maximum voluntary contraction (MVC) decline with an average mean absolute error of 4.9%MVC. Subsequently, an HiL control mechanism was developed, utilizing ratings of perceived fatigue and state of fatigue values as reference metrics. The presented control approach effectively regulates fatigue levels within a 0%MVC–6%MVC steady-state error range during simulations. Experimental validation confirmed this performance, however, with partly higher steady-state errors mainly due to the restrictions of the exoskeleton's assistance. This preliminary study provides a promising foundation for future research, demonstrating the potential to manage fatigue effectively in exoskeleton users, offering an improved, personalized experience.


  • Physiological hardware-in-the-loop test bench for mechanical ventilation

    by Philip von Platen, Lennard Lesch, Arnhold Lohse, Steffen Leonhardt, Marian Walter

    This article presents a hardware-in-the-loop system that can simulate a patient’s physiological responses to mechanical ventilation. The system includes a hardware platform with a mechatronic lung that can physically simulate the respiratory mechanics. A computational patient model replicates the pressure/volume behaviour of the lungs and the impaired gas exchange. Based on current ventilator settings, the model calculates signal curves, which are then transmitted to the physically existing sensors. This enables the test bench to reproduce the pressure/volume behaviour of the lungs and the gas exchange of a simulated patient on mechanical ventilation. In the future, the hardware-in-the-loop system could play an important role in testing and validating highly automated functions in mechanical ventilation and represent an alternative to animal testing.


  • Robust closed-loop control of systemic oxygenation in acute lung injury

    by Philip von Platen, Adel Abdelsamed, Arnhold Lohse, Martin Russ, Celina Wolters, Philipp A. Pickerodt, Roland C.E. Francis, Steffen Leonhardt, Marian Walter


  • Open Access

    Closed-Loop FES Control of a Hybrid Exoskeleton during Sit-to-Stand Exercises: Concept and First Evaluation

    by Chenglin Lyu, Pedro Truppel Morim, Bernhard Penzlin, Felix Röhren, Lukas Bergmann, Philip von Platen, Cornelius Bollheimer, Steffen Leonhardt, Chuong Ngo

    Rehabilitation of paralysis caused by a stroke or a spinal cord injury remains a complex and time-consuming task. This work proposes a hybrid exoskeleton approach combining a traditional exoskeleton and functional electrical stimulation (FES) as a promising method in rehabilitation. However, hybrid exoskeletons with a closed-loop FES control strategy are functionally challenging to achieve and have not been reported often. Therefore, this study aimed to investigate a powered lower-limb exoskeleton with a closed-loop FES control for Sit-to-Stand (STS) movements. A body motion capture system was applied to record precise hip and knee trajectories of references for establishing the human model. A closed-loop control strategy with allocation factors is proposed featuring a two-layer cascaded proportional–integral–derivative (PID) controller for both FES and exoskeleton control. Experiments were performed on two participants to examine the feasibility of the hybrid exoskeleton and the closed-loop FES control. Both open- and closed-loop FES control showed the desired performance with a relatively low root-mean-squared error (max 1.3∘ in open-loop and max 4.1∘ in closed-loop) in hip and knee trajectories. Notably, the closed-loop FES control strategy can achieve the same performance with nearly 60% of the electrical power input compared to the open-loop control, which reduced muscle fatigue and improved robustness during the training. This study provides novel insights into body motion capture application and proposes a closed-loop FES control for hybrid exoskeletons.


  • Open Access

    SOLVe: a closed-loop system focused on protective mechanical ventilation

    by Philip von Platen, Philipp A. Pickerodt, Martin Russ, Mahdi Taher, Lea Hinken, Wolfgang Braun, Rainer Köbrich, Anake Pomprapa, Roland C. E. Francis, Steffen Leonhardt, et al.

    Background: Mechanical ventilation is an essential component in the treatment of patients with acute respiratory distress syndrome. Prompt adaptation of the settings of a ventilator to the variable needs of patients is essential to ensure personalised and protective ventilation. Still, it is challenging and time-consuming for the therapist at the bedside. In addition, general implementation barriers hinder the timely incorporation of new evidence from clinical studies into routine clinical practice. Results: We present a system combing clinical evidence and expert knowledge within a physiological closed-loop control structure for mechanical ventilation. The system includes multiple controllers to support adequate gas exchange while adhering to multiple evidence-based components of lung protective ventilation. We performed a pilot study on three animals with an induced ARDS. The system achieved a time-in-target of over 75 % for all targets and avoided any critical phases of low oxygen saturation, despite provoked disturbances such as disconnections from the ventilator and positional changes of the subject. Conclusions: The presented system can provide personalised and lung-protective ventilation and reduce clinician workload in clinical practice.


  • Open Access

    The dawn of physiological closed-loop ventilation—a review

    by Philip von Platen, Anake Pomprapa, Burkhard Lachmann, Steffen Leonhardt

    The level of automation in mechanical ventilation has been steadily increasing over the last few decades. There has recently been renewed interest in physiological closed-loop control of ventilation. The development of these systems has followed a similar path to that of manual clinical ventilation, starting with ensuring optimal gas exchange and shifting to the prevention of ventilator-induced lung injury. Systems currently aim to encompass both aspects, and early commercial systems are appearing. These developments remain unknown to many clinicians and, hence, limit their adoption into the clinical environment. This review shows the evolution of the physiological closed-loop control of mechanical ventilation.


  • Robust physiological control of rotary blood pumps for heart failure therapy

    by Daniel Rüschen, Sebastian Opitz, Philip von Platen, Leonie Korn, Steffen Leonhardt, Marian Walter

    Left ventricular assist devices (LVADs) have become a viable alternative to heart transplantation in heart failure therapy. In clinical practice, rotary blood pumps used as LVADs are operated at a constant rotational speed and thus do not adapt to the varying demand of the patient. This paper presents a robust control approach for automatic adaptation of the blood pump speed to the blood flow demand of the patient’s body, which enables a defined load sharing between an LVAD and the native ventricle. Robust stability was checked using a detailed model of the human cardiovascular system with uncertainties that describe the most important native physiological control loops as well as a range of pathologies. The robust assistance controller was tested in an in vivo setup and was able to stabilize the cardiovascular system after myocardial infarction.