Hans J. Zander
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Hans J. Zander has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Scott F. Lempka
University of Michigan
4 shared publications Andrew J Will
Twin Cities Pain Clinic, Edina, MN, United States of America
1 shared publicationAnthony F. DiMarco
Department of Physical Medicine and Rehabilitation, Case Western Reserve University, Cleveland, OH, USA
1 shared publication- Carlos J. Anaya
Iota Biosciences, Inc., Alameda, CA
1 shared publication - David A. Dinsmoor
Medtronic plc, Minneapolis, MN, United States
1 shared publication - Evan R. Rogers
Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI, United States of America
1 shared publication
Latest Publications
- Open Access
- 1 August 2023
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 20 (4) , 046028
Evoked compound action potentials during spinal cord stimulation: effects of posture and pulse width on signal features and neural activation within the spinal cord
Objective. Evoked compound action potential (ECAP) recordings have emerged as a quantitative measure of the neural response during spinal cord stimulation (SCS) to treat pain. However, utilization of ECAP recordings to optimize stimulation efficacy requires an understanding of the factors influencing these recordings and their relationship to the underlying neural activation. Approach. We acquired a library of ECAP recordings from 56 patients over a wide assortment of postures and stimulation parameters, and then processed these signals to quantify several aspects of these recordings (e.g., ECAP threshold (ET), amplitude, latency, growth rate). We compared our experimental findings against a computational model that examined the effect of variable distances between the spinal cord and the SCS electrodes. Main results. Postural shifts strongly influenced the experimental ECAP recordings, with a 65.7% lower ET and 178.5% higher growth rate when supine versus seated. The computational model exhibited similar trends, with a 71.9% lower ET and 231.5% higher growth rate for a 2.0 mm cerebrospinal fluid (CSF) layer (representing a supine posture) versus a 4.4 mm CSF layer (representing a prone posture). Furthermore, the computational model demonstrated that constant ECAP amplitudes may not equate to a constant degree of neural activation. Significance. These results demonstrate large variability across all ECAP metrics and the inability of a constant ECAP amplitude to provide constant neural activation. These results are critical to improve the delivery, efficacy, and robustness of clinical SCS technologies utilizing these ECAP recordings to provide closed-loop stimulation.
- 1 August 2023
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 20 (4) , 046028
Open AccessEvoked compound action potentials during spinal cord stimulation: effects of posture and pulse width on signal features and neural activation within the spinal cord
Objective. Evoked compound action potential (ECAP) recordings have emerged as a quantitative measure of the neural response during spinal cord stimulation (SCS) to treat pain. However, utilization of ECAP recordings to optimize stimulation efficacy requires an understanding of the factors influencing these recordings and their relationship to the underlying neural activation. Approach. We acquired a library of ECAP recordings from 56 patients over a wide assortment of postures and stimulation parameters, and then processed these signals to quantify several aspects of these recordings (e.g., ECAP threshold (ET), amplitude, latency, growth rate). We compared our experimental findings against a computational model that examined the effect of variable distances between the spinal cord and the SCS electrodes. Main results. Postural shifts strongly influenced the experimental ECAP recordings, with a 65.7% lower ET and 178.5% higher growth rate when supine versus seated. The computational model exhibited similar trends, with a 71.9% lower ET and 231.5% higher growth rate for a 2.0 mm cerebrospinal fluid (CSF) layer (representing a supine posture) versus a 4.4 mm CSF layer (representing a prone posture). Furthermore, the computational model demonstrated that constant ECAP amplitudes may not equate to a constant degree of neural activation. Significance. These results demonstrate large variability across all ECAP metrics and the inability of a constant ECAP amplitude to provide constant neural activation. These results are critical to improve the delivery, efficacy, and robustness of clinical SCS technologies utilizing these ECAP recordings to provide closed-loop stimulation.
- 1 December 2022
- Published by Elsevier in Neuromodulation: Technology at the Neural Interface
- Vol. 25 (8) , 1317-1329
Model-Based Optimization of Spinal Cord Stimulation for Inspiratory Muscle Activation
- 1 December 2022
- Published by Elsevier in Neuromodulation: Technology at the Neural Interface
- Vol. 25 (8) , 1317-1329
Model-Based Optimization of Spinal Cord Stimulation for Inspiratory Muscle Activation
- 25 September 2021
- Published by Elsevier in The Journal of Pain
- Vol. 23 (3) , 434-449
Neural Recruitment During Conventional, Burst, and 10-kHz Spinal Cord Stimulation for Pain
- 25 September 2021
- Published by Elsevier in The Journal of Pain
- Vol. 23 (3) , 434-449
Neural Recruitment During Conventional, Burst, and 10-kHz Spinal Cord Stimulation for Pain
- 1 June 2020
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 17 (3) , 036019
Anatomical and technical factors affecting the neural response to epidural spinal cord stimulation
Objective . Spinal cord stimulation (SCS) is a common neurostimulation therapy to treat chronic pain. Computational models represent a valuable tool to study the potential mechanisms of action of SCS and to optimize the design and implementation of SCS technologies. However, it is imperative that these computational models include the appropriate level of detail to accurately predict the neural response to SCS and to correlate model predictions with clinical outcomes. Therefore, the goal of this study was to investigate several anatomic and technical factors that may affect model-based predictions of neural activation during thoracic SCS. Approach . We developed computational models that consisted of detailed finite element models of the lower thoracic spinal cord, surrounding tissues, and implanted SCS electrode arrays. We positioned multicompartment models of sensory axons within the spinal cord to calculate the activation threshold for each sensory axon. We then investigated how activation thresholds changed as a function of several anatomical variables (e.g. spine geometry, dorsal rootlet anatomy), stimulation type (i.e. voltage-controlled vs. current-controlled), electrode impedance, lead position, lead type, and electrical properties of surrounding tissues (e.g. dura conductivity, frequency-dependent conductivity). Main results. Several anatomic and modeling factors produced significant percent differences or errors in activation thresholds. Rostrocaudal positioning of the cathode with respect to the vertebrae had a large effect (up to 32%) on activation thresholds. Variability in electrode impedance produced significant changes in activation thresholds for voltage-controlled stimulation (38% to 51%), but had little effect on activation thresholds for current-controlled stimulation (less than 13%). Changing the dura conductivity also produced significant differences in activation thresholds. Significance. This study demonstrates several anatomic and technical factors that can affect the neural response to SCS. These factors should be considered in clinical implementation and in future computational modeling studies of thoracic SCS.
- 1 June 2020
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 17 (3) , 036019
Anatomical and technical factors affecting the neural response to epidural spinal cord stimulation
Objective . Spinal cord stimulation (SCS) is a common neurostimulation therapy to treat chronic pain. Computational models represent a valuable tool to study the potential mechanisms of action of SCS and to optimize the design and implementation of SCS technologies. However, it is imperative that these computational models include the appropriate level of detail to accurately predict the neural response to SCS and to correlate model predictions with clinical outcomes. Therefore, the goal of this study was to investigate several anatomic and technical factors that may affect model-based predictions of neural activation during thoracic SCS. Approach . We developed computational models that consisted of detailed finite element models of the lower thoracic spinal cord, surrounding tissues, and implanted SCS electrode arrays. We positioned multicompartment models of sensory axons within the spinal cord to calculate the activation threshold for each sensory axon. We then investigated how activation thresholds changed as a function of several anatomical variables (e.g. spine geometry, dorsal rootlet anatomy), stimulation type (i.e. voltage-controlled vs. current-controlled), electrode impedance, lead position, lead type, and electrical properties of surrounding tissues (e.g. dura conductivity, frequency-dependent conductivity). Main results. Several anatomic and modeling factors produced significant percent differences or errors in activation thresholds. Rostrocaudal positioning of the cathode with respect to the vertebrae had a large effect (up to 32%) on activation thresholds. Variability in electrode impedance produced significant changes in activation thresholds for voltage-controlled stimulation (38% to 51%), but had little effect on activation thresholds for current-controlled stimulation (less than 13%). Changing the dura conductivity also produced significant differences in activation thresholds. Significance. This study demonstrates several anatomic and technical factors that can affect the neural response to SCS. These factors should be considered in clinical implementation and in future computational modeling studies of thoracic SCS.
- 1 April 2020
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 17 (2) , 026033
Realistic anatomically detailed open-source spinal cord stimulation (RADO-SCS) model
Objective . Computational current flow models of spinal cord stimulation (SCS) are widely used in device development, clinical trial design, and patient programming. Proprietary models of varied sophistication have been developed. An open-source model with state-of-the-art precision would serve as a standard for SCS simulation. Approach . We developed a sophisticated SCS modeling platform, named Realistic Anatomically Detailed Open-Source Spinal Cord Stimulation (RADO-SCS) model. This platform consists of realistic and detailed spinal cord and ancillary tissues anatomy derived based on prior imaging and cadaveric studies. In our finite element model of the T9-T11 spine levels, we represented the following tissues: vertebrae, intervertebral disc, epidural space, epidural space vasculature, dura mater, dural sac, intraforaminal tissue, cerebrospinal fluid (CSF), whitematter, spinal cord vasculature, Lissauer’s tract, gray matter, dorsal and ventral roots and rootlets, dorsal root ganglion (DRG), sympathetic chain (trunk and ganglion), thoracic aorta and its branching, peripheral vasculature, and soft tissues (thorax). As an exemplary application to illustrate the model workflow, we simulated a bipolar SCS montage and calculated the corresponding activation thresholds for individual axons populating the spinal cord. Main results . RADO-SCS provides state-of-the-art precision across 19 tissue compartments. The resulting model calculations of the electric fields generated in the white-matter and gray matter, and the axonal activation thresholds are broadly consistent with prior simulations. Significance . The RADO-SCS can be used to simulate any SCS approach with both unprecedented resolution (precision) and transparency (reproducibility). Freely-available online, the RADO-SCS will be updated continuously with version control.
- 1 April 2020
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 17 (2) , 026033
Realistic anatomically detailed open-source spinal cord stimulation (RADO-SCS) model
Objective . Computational current flow models of spinal cord stimulation (SCS) are widely used in device development, clinical trial design, and patient programming. Proprietary models of varied sophistication have been developed. An open-source model with state-of-the-art precision would serve as a standard for SCS simulation. Approach . We developed a sophisticated SCS modeling platform, named Realistic Anatomically Detailed Open-Source Spinal Cord Stimulation (RADO-SCS) model. This platform consists of realistic and detailed spinal cord and ancillary tissues anatomy derived based on prior imaging and cadaveric studies. In our finite element model of the T9-T11 spine levels, we represented the following tissues: vertebrae, intervertebral disc, epidural space, epidural space vasculature, dura mater, dural sac, intraforaminal tissue, cerebrospinal fluid (CSF), whitematter, spinal cord vasculature, Lissauer’s tract, gray matter, dorsal and ventral roots and rootlets, dorsal root ganglion (DRG), sympathetic chain (trunk and ganglion), thoracic aorta and its branching, peripheral vasculature, and soft tissues (thorax). As an exemplary application to illustrate the model workflow, we simulated a bipolar SCS montage and calculated the corresponding activation thresholds for individual axons populating the spinal cord. Main results . RADO-SCS provides state-of-the-art precision across 19 tissue compartments. The resulting model calculations of the electric fields generated in the white-matter and gray matter, and the axonal activation thresholds are broadly consistent with prior simulations. Significance . The RADO-SCS can be used to simulate any SCS approach with both unprecedented resolution (precision) and transparency (reproducibility). Freely-available online, the RADO-SCS will be updated continuously with version control.