Miao Cao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Miao Cao has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
- Kun-Kun Deng
College of Materials Science and Engineering, Taiyuan University of Technology, Taiyuan 030024, China
3 shared publications Cui-Ju Wang
2 shared publicationsFei Li
College of Materials Science and Engineering, Taiyuan University of Science and Technology, Taiyuan, China
2 shared publications- Huiqin Chen
School of Materials Science and Engineering, Taiyuan University of Science and Technology, Taiyuan, China
2 shared publications Kai-Bo Nie
2 shared publicationsShuang Liu
College of Materials Science and Engineering, Taiyuan University of Science and Technology, Taiyuan, China
2 shared publications
Latest Publications
- 29 April 2026
- Published by Springer Nature in Metals and Materials International
- Vol. 32 (9) , 1-17
Achieving Excellent Stamping Formability by Regulating Interface in TA1/2024/AZ31/2024/TA1 Laminated Composites
- 29 April 2026
- Published by Springer Nature in Metals and Materials International
- Vol. 32 (9) , 1-17
Achieving Excellent Stamping Formability by Regulating Interface in TA1/2024/AZ31/2024/TA1 Laminated Composites
- 6 April 2025
- Published by Wiley in Advanced Engineering Materials
- Vol. 27 (12)
Study on the Effect of Annealing Temperature on the Forming and Mechanical Properties of Hot‐Pressed Ti/Al/Mg/Al/Ti‐Laminated Composites
To investigate the effect of annealing temperature on the forming and mechanical properties of hot‐pressed Ti/Al/Mg/Al/Ti (LMCS), LMCS was prepared using a hot‐pressing process at a pressure of 175 MPa and 480 °C for 60 min. The interface structure and formability were controlled by annealing at 200, 250, 300, and 350 °C for 1 h. The corresponding performance indicators were tested by tensiling, cupping, and T‐peeling tests and analyzed and characterized using scanning electron microscopy, electron backscatter diffraction, and X‐ray diffraction. The results show that at an annealing temperature of 300 °C, the basal texture is weak, and static recrystallization leads to uniform grain growth. The smaller average nuclear orientation difference (KAM) results in a decrease in dislocation density and local strain. Good formability is achieved at 300 °C, with a minimum ultimate tensile strength and yield strength of 189.02 and 237.75 MPa and a maximum elongation and cupping value of 3.62% and 4.88 mm, respectively. This provides theoretical guidance for the development of practical annealing processes for LMCS.
- 6 April 2025
- Published by Wiley in Advanced Engineering Materials
- Vol. 27 (12)
Study on the Effect of Annealing Temperature on the Forming and Mechanical Properties of Hot‐Pressed Ti/Al/Mg/Al/Ti‐Laminated Composites
To investigate the effect of annealing temperature on the forming and mechanical properties of hot‐pressed Ti/Al/Mg/Al/Ti (LMCS), LMCS was prepared using a hot‐pressing process at a pressure of 175 MPa and 480 °C for 60 min. The interface structure and formability were controlled by annealing at 200, 250, 300, and 350 °C for 1 h. The corresponding performance indicators were tested by tensiling, cupping, and T‐peeling tests and analyzed and characterized using scanning electron microscopy, electron backscatter diffraction, and X‐ray diffraction. The results show that at an annealing temperature of 300 °C, the basal texture is weak, and static recrystallization leads to uniform grain growth. The smaller average nuclear orientation difference (KAM) results in a decrease in dislocation density and local strain. Good formability is achieved at 300 °C, with a minimum ultimate tensile strength and yield strength of 189.02 and 237.75 MPa and a maximum elongation and cupping value of 3.62% and 4.88 mm, respectively. This provides theoretical guidance for the development of practical annealing processes for LMCS.
- Open Access
- 14 March 2023
- Published by Springer Nature in Metals and Materials International
- Vol. 29 (8) , 2413
Correction: Effect of Interface on Mechanical Properties and Stamping Formability of Ti/Al Multilayered Composites
- 14 March 2023
- Published by Springer Nature in Metals and Materials International
- Vol. 29 (8) , 2413
Open AccessCorrection: Effect of Interface on Mechanical Properties and Stamping Formability of Ti/Al Multilayered Composites
- 12 October 2022
- Published by Springer Nature in Metals and Materials International
- Vol. 29 (5) , 1469-1488
Effect of Interface on Mechanical Properties and Stamping Formability of Ti/Al Multilayered Composites
- 12 October 2022
- Published by Springer Nature in Metals and Materials International
- Vol. 29 (5) , 1469-1488
Effect of Interface on Mechanical Properties and Stamping Formability of Ti/Al Multilayered Composites
- Open Access
- 23 September 2022
- Published by Association for Computing Machinery (ACM)
- p. 1032-1036
Design of Parallel Light Tube Optical System for Collimation System of White-light Zero Position Instrument
Aiming at the design problem of parallel light tube optical system in the collimation system of high precision white light nullimeter, a parallel optical tube system for the collimation system of white light nullimeter is designed based on the design idea of Newton reflection telescope. The parallel optical tube system is designed based on off-axis Newton reflective structure. The effective aperture D is 150 mm, the focal length is 1500 mm, and the off-axis amount is 200 mm. The simulation experiment of the designed parallel optical tube system is carried out by ZEMAX software. When the Nyquist frequency is set to 50 lp/mm, the MTF values of the parallel optical tube system in the four fields of 0°, 0.01°, 0.02° and 0.03° are all greater than 0.3, and the MTF value in the 0° field of view is about 0.6445, and the deflection angle of the emitted parallel light is about 0.02°, which meets the design requirements of the white light aiming mirror zero position instrument collimation system.
- 23 September 2022
- Published by Association for Computing Machinery (ACM)
- p. 1032-1036
Open AccessDesign of Parallel Light Tube Optical System for Collimation System of White-light Zero Position Instrument
Aiming at the design problem of parallel light tube optical system in the collimation system of high precision white light nullimeter, a parallel optical tube system for the collimation system of white light nullimeter is designed based on the design idea of Newton reflection telescope. The parallel optical tube system is designed based on off-axis Newton reflective structure. The effective aperture D is 150 mm, the focal length is 1500 mm, and the off-axis amount is 200 mm. The simulation experiment of the designed parallel optical tube system is carried out by ZEMAX software. When the Nyquist frequency is set to 50 lp/mm, the MTF values of the parallel optical tube system in the four fields of 0°, 0.01°, 0.02° and 0.03° are all greater than 0.3, and the MTF value in the 0° field of view is about 0.6445, and the deflection angle of the emitted parallel light is about 0.02°, which meets the design requirements of the white light aiming mirror zero position instrument collimation system.
- Open Access
- 1 September 2021
- Published by Elsevier in Journal of Materials Research and Technology
- Vol. 14, 1655-1669
Effect of interface on mechanical properties and formability of Ti/Al/Ti laminated composites
- 1 September 2021
- Published by Elsevier in Journal of Materials Research and Technology
- Vol. 14, 1655-1669
Open AccessEffect of interface on mechanical properties and formability of Ti/Al/Ti laminated composites
- 1 April 2020
- Published by Elsevier in Journal of Materials Science & Technology
- Vol. 42, 17-27
Microstructural evolution and deformation behavior of copper alloy during rheoforging process
- 1 April 2020
- Published by Elsevier in Journal of Materials Science & Technology
- Vol. 42, 17-27
Microstructural evolution and deformation behavior of copper alloy during rheoforging process
- Open Access
- 1 January 2020
- Published by FapUNIFESP (SciELO) in Materials Research
- Vol. 23 (1)
Effect of Interface on Mechanical Properties of Ti/Al/Mg/Al/Ti Laminated Composites
Ti/Al/Mg/Al/Ti laminated composites were fabricated via hot-pressing at 350 °C, 400 °C and 450 °C successfully. The influences of interface morphology, diffusion zone, constraint effect on the mechanical properties were investigated. At Ti/Al interface, intermetallic compounds aren’t found. Whereas, they form at Al/Mg interface. With the increasing temperature, the bonding strength of Al/Mg interface doesn’t change linearly, and the maximum strength is obtained at 400 °C because of intermetallic compounds with appropriate thickness. With the increase of temperature, the hardness at both Ti/Al and Al/Mg interfaces increases owing to the solid solution and the intermetallic phases. Also, the ultimate tensile strength of LMCs increases with sacrificing the fracture elongation. The rule of mixture is used to predict the theoretical strength. It is found that the theoretical values are less than the measured, and the reasons may relate to interfaces in Ti/Al/Mg/Al/Ti laminated composites.
- 1 January 2020
- Published by FapUNIFESP (SciELO) in Materials Research
- Vol. 23 (1)
Open AccessEffect of Interface on Mechanical Properties of Ti/Al/Mg/Al/Ti Laminated Composites
Ti/Al/Mg/Al/Ti laminated composites were fabricated via hot-pressing at 350 °C, 400 °C and 450 °C successfully. The influences of interface morphology, diffusion zone, constraint effect on the mechanical properties were investigated. At Ti/Al interface, intermetallic compounds aren’t found. Whereas, they form at Al/Mg interface. With the increasing temperature, the bonding strength of Al/Mg interface doesn’t change linearly, and the maximum strength is obtained at 400 °C because of intermetallic compounds with appropriate thickness. With the increase of temperature, the hardness at both Ti/Al and Al/Mg interfaces increases owing to the solid solution and the intermetallic phases. Also, the ultimate tensile strength of LMCs increases with sacrificing the fracture elongation. The rule of mixture is used to predict the theoretical strength. It is found that the theoretical values are less than the measured, and the reasons may relate to interfaces in Ti/Al/Mg/Al/Ti laminated composites.