Andressa Zabudovski Schroeder
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Andressa Zabudovski Schroeder has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Alexandre Roberto Roman Coelho
Universidade Federal do Paraná, Brazil
2 shared publications - Edmar Stieven Filho
Hospital de Clínicas da Universidade Federal do Paraná Curitiba Brazil
2 shared publications - Paul André Alain Milcent
Universidade Federal do Paraná (UFPR), Brasil
2 shared publications - Sthéphano Pellizzaro Rosa
Universidade Federal do Paraná, Brazil
2 shared publications - Ygor Luiz Degraf da Fonseca
Universidade Federal do Paraná, Brazil
2 shared publications - Adria Karina Farias de Aquino
Universidade Federal do Paraná, Hospital de Clínicas
1 shared publication
Latest Publications
- Open Access
- 10 December 2021
- Published by Universidade de São Paulo. Agência de Bibliotecas e Coleções Digitais in Revista de Medicina
- Vol. 100 (5) , 442-448
Apendicectomia aberta versus videolaparoscópica em crianças: estudo prospectivo em hospital público terciário
Introdução: Apendicectomia é um dos procedimentos cirúrgicos mais realizados em crianças e é a terapia de escolha no tratamento da apendicite aguda. Há evidências na literatura que favorecem a realização da cirurgia pela via laparoscópica em detrimento da via aberta na população pediátrica. Objetivo: comparar a apendicectomia aberta e laparoscópica no tratamento da apendicite aguda em crianças em um hospital terciário público do Brasil. Métodos: estudo observacional prospectivo comparando apendicectomias abertas e videolaparoscópicas realizadas em pacientes pediátricos com apendicite aguda atendidos entre março/2017 e março/2018. Foram analisados aspectos epidemiológicos; pré-operatórios (clínica, exames laboratoriais e de imagem, tempo entre admissão e procedimento); intra-operatórios (tempo de procedimento, técnica); pós-operatório (tempo de internação; complicações). Resultados: amostra de 63 pacientes, com média de idade de 8 anos. 80,9% apresentavam vômitos, sinal de Bloomberg em 63,5% e dor abdominal difusa em 71,4%. Realizado hemograma em 43 pacientes, com 72% de leucocitose e 51,2%, bastonetose; radiografia abdominal em 12 e ultrassonografia em 47,6%. 31,7% realizaram apendicectomia laparoscópica, enquanto 68,3%, apendicectomia aberta. Não houve diferença entre os grupos quanto as condições da cavidade e características do apêndice. O grupo da cirurgia aberta teve 52,3% de apendicectomias complicadas, complicação pós-operatória em 2,3% e tempo de internação médio de 3 dias, já no da laparoscópia, 60% foram complicadas, 10% com complicação pós-operatória e 2,9 dias de tempo de internação médio. Conclusão: o presente estudo permite afirmar, com limitações estatísticas, que não há diferença entre apendicectomia aberta e videolaparoscópica quanto ao tempo entre a admissão e o procedimento, tempo de internação e complicações pós-operatórias, sendo relevante a diferença no tempo do procedimento.
- 10 December 2021
- Published by Universidade de São Paulo. Agência de Bibliotecas e Coleções Digitais in Revista de Medicina
- Vol. 100 (5) , 442-448
Open AccessApendicectomia aberta versus videolaparoscópica em crianças: estudo prospectivo em hospital público terciário
Introdução: Apendicectomia é um dos procedimentos cirúrgicos mais realizados em crianças e é a terapia de escolha no tratamento da apendicite aguda. Há evidências na literatura que favorecem a realização da cirurgia pela via laparoscópica em detrimento da via aberta na população pediátrica. Objetivo: comparar a apendicectomia aberta e laparoscópica no tratamento da apendicite aguda em crianças em um hospital terciário público do Brasil. Métodos: estudo observacional prospectivo comparando apendicectomias abertas e videolaparoscópicas realizadas em pacientes pediátricos com apendicite aguda atendidos entre março/2017 e março/2018. Foram analisados aspectos epidemiológicos; pré-operatórios (clínica, exames laboratoriais e de imagem, tempo entre admissão e procedimento); intra-operatórios (tempo de procedimento, técnica); pós-operatório (tempo de internação; complicações). Resultados: amostra de 63 pacientes, com média de idade de 8 anos. 80,9% apresentavam vômitos, sinal de Bloomberg em 63,5% e dor abdominal difusa em 71,4%. Realizado hemograma em 43 pacientes, com 72% de leucocitose e 51,2%, bastonetose; radiografia abdominal em 12 e ultrassonografia em 47,6%. 31,7% realizaram apendicectomia laparoscópica, enquanto 68,3%, apendicectomia aberta. Não houve diferença entre os grupos quanto as condições da cavidade e características do apêndice. O grupo da cirurgia aberta teve 52,3% de apendicectomias complicadas, complicação pós-operatória em 2,3% e tempo de internação médio de 3 dias, já no da laparoscópia, 60% foram complicadas, 10% com complicação pós-operatória e 2,9 dias de tempo de internação médio. Conclusão: o presente estudo permite afirmar, com limitações estatísticas, que não há diferença entre apendicectomia aberta e videolaparoscópica quanto ao tempo entre a admissão e o procedimento, tempo de internação e complicações pós-operatórias, sendo relevante a diferença no tempo do procedimento.
- Open Access
- 1 January 2020
- Published by FapUNIFESP (SciELO) in Revista Brasileira de Educação Médica
- Vol. 44 (1)
An Affordable Knee Arthroscopy Simulator
Introduction: The objective of this study is to describe a model of knee arthroscopy simulator that is affordable, low-cost and easily reproducible, aiming to enable the diffusion of more effective active teaching and training methodologies. Methods: For the creation of the arthroscopic camera, an endoscopic camera for mobile phones and computers model SXT-5.0M manufactured by KKMOON were used. The camera was introduced in a metal tube, which was coupled to a set of three 20 mm PVC hydraulic connectors to simulate the handle and sleeve of the arthroscope. The camera has a resolution of 1280 x 720 pixels and is equipped with six built-in white LED lamps, simulating and eliminating the need to use an additional light source. The knee model was developed using a PVC pipe fixed on a wooden support, to which synthetic femur and tibia models were affixed. Four three-centimeter diameter holes, compatible with the standard arthroscopic portals, were made in the body of the PVC pipe. For the menisci, a model was made out of modeling clay (Corfix®), until the anatomical structures were close to the real ones. The model consists of both menisci and the intercondylar eminence, simulating the proximal tibial articular surface. The model made out of modeling clay was the basis for the production of a thin Crystal Polyester Resin mold. Using the resin mold, the meniscal models were made of Silicone Rubber Type II, widely used in industry and crafts. Results: A functional and reproducible simulator was obtained, consisting of a knee model and an arthroscopic camera. The simulator works adequately adapted to a TV, monitor or computer, and allows the simulation of diagnostic procedures, meniscectomy and meniscoplasty. Conclusion: It is possible to develop a knee arthroscopy simulator, with components available in local and electronic commerce, at a cost of approximately R$ 300.
- 1 January 2020
- Published by FapUNIFESP (SciELO) in Revista Brasileira de Educação Médica
- Vol. 44 (1)
Open AccessAn Affordable Knee Arthroscopy Simulator
Introduction: The objective of this study is to describe a model of knee arthroscopy simulator that is affordable, low-cost and easily reproducible, aiming to enable the diffusion of more effective active teaching and training methodologies. Methods: For the creation of the arthroscopic camera, an endoscopic camera for mobile phones and computers model SXT-5.0M manufactured by KKMOON were used. The camera was introduced in a metal tube, which was coupled to a set of three 20 mm PVC hydraulic connectors to simulate the handle and sleeve of the arthroscope. The camera has a resolution of 1280 x 720 pixels and is equipped with six built-in white LED lamps, simulating and eliminating the need to use an additional light source. The knee model was developed using a PVC pipe fixed on a wooden support, to which synthetic femur and tibia models were affixed. Four three-centimeter diameter holes, compatible with the standard arthroscopic portals, were made in the body of the PVC pipe. For the menisci, a model was made out of modeling clay (Corfix®), until the anatomical structures were close to the real ones. The model consists of both menisci and the intercondylar eminence, simulating the proximal tibial articular surface. The model made out of modeling clay was the basis for the production of a thin Crystal Polyester Resin mold. Using the resin mold, the meniscal models were made of Silicone Rubber Type II, widely used in industry and crafts. Results: A functional and reproducible simulator was obtained, consisting of a knee model and an arthroscopic camera. The simulator works adequately adapted to a TV, monitor or computer, and allows the simulation of diagnostic procedures, meniscectomy and meniscoplasty. Conclusion: It is possible to develop a knee arthroscopy simulator, with components available in local and electronic commerce, at a cost of approximately R$ 300.
- Open Access
- 1 January 2020
- Published by FapUNIFESP (SciELO) in Revista Brasileira de Educação Médica
- Vol. 44 (1)
Um Simulador de Artroscopia de Joelho Acessível
Introduction: The objective of this study is to describe a model of knee arthroscopy simulator that is affordable, low-cost and easily reproducible, aiming to enable the diffusion of more effective active teaching and training methodologies. Methods: For the creation of the arthroscopic camera, an endoscopic camera for mobile phones and computers model SXT-5.0M manufactured by KKMOON were used. The camera was introduced in a metal tube, which was coupled to a set of three 20 mm PVC hydraulic connectors to simulate the handle and sleeve of the arthroscope. The camera has a resolution of 1280 x 720 pixels and is equipped with six built-in white LED lamps, simulating and eliminating the need to use an additional light source. The knee model was developed using a PVC pipe fixed on a wooden support, to which synthetic femur and tibia models were affixed. Four three-centimeter diameter holes, compatible with the standard arthroscopic portals, were made in the body of the PVC pipe. For the menisci, a model was made out of modeling clay (Corfix®), until the anatomical structures were close to the real ones. The model consists of both menisci and the intercondylar eminence, simulating the proximal tibial articular surface. The model made out of modeling clay was the basis for the production of a thin Crystal Polyester Resin mold. Using the resin mold, the meniscal models were made of Silicone Rubber Type II, widely used in industry and crafts. Results: A functional and reproducible simulator was obtained, consisting of a knee model and an arthroscopic camera. The simulator works adequately adapted to a TV, monitor or computer, and allows the simulation of diagnostic procedures, meniscectomy and meniscoplasty. Conclusion: It is possible to develop a knee arthroscopy simulator, with components available in local and electronic commerce, at a cost of approximately R$ 300.
- 1 January 2020
- Published by FapUNIFESP (SciELO) in Revista Brasileira de Educação Médica
- Vol. 44 (1)
Open AccessUm Simulador de Artroscopia de Joelho Acessível
Introduction: The objective of this study is to describe a model of knee arthroscopy simulator that is affordable, low-cost and easily reproducible, aiming to enable the diffusion of more effective active teaching and training methodologies. Methods: For the creation of the arthroscopic camera, an endoscopic camera for mobile phones and computers model SXT-5.0M manufactured by KKMOON were used. The camera was introduced in a metal tube, which was coupled to a set of three 20 mm PVC hydraulic connectors to simulate the handle and sleeve of the arthroscope. The camera has a resolution of 1280 x 720 pixels and is equipped with six built-in white LED lamps, simulating and eliminating the need to use an additional light source. The knee model was developed using a PVC pipe fixed on a wooden support, to which synthetic femur and tibia models were affixed. Four three-centimeter diameter holes, compatible with the standard arthroscopic portals, were made in the body of the PVC pipe. For the menisci, a model was made out of modeling clay (Corfix®), until the anatomical structures were close to the real ones. The model consists of both menisci and the intercondylar eminence, simulating the proximal tibial articular surface. The model made out of modeling clay was the basis for the production of a thin Crystal Polyester Resin mold. Using the resin mold, the meniscal models were made of Silicone Rubber Type II, widely used in industry and crafts. Results: A functional and reproducible simulator was obtained, consisting of a knee model and an arthroscopic camera. The simulator works adequately adapted to a TV, monitor or computer, and allows the simulation of diagnostic procedures, meniscectomy and meniscoplasty. Conclusion: It is possible to develop a knee arthroscopy simulator, with components available in local and electronic commerce, at a cost of approximately R$ 300.