Benaoumeur Aour
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Benaoumeur Aour has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Abderrahim Talha
University of Sidi Bel Abbes
2 shared publications A. S. Bouaziz
École Nationale Polytechnique d’Oran, Algeria
1 shared publication- Ahmed Drai
Mechanical Engineering department, Mustapha STAMBOULI University of Mascara, 29000, Mascara, Algeria
1 shared publication - Belabbes Bachir Bouiadjra
LMPM, Department of Mechanical Engineering, University of Sidi Bel Abbes, Sidi Bel Abbes, Algeria
1 shared publication - D. Aroussi
École Nationale Polytechnique d’Oran, Algeria
1 shared publication - Mohammed Salah Bennouna
Département de génie mécanique, faculté des sciences appliquées, université Kasdi-Merbah, Ouargla, Algérie
1 shared publication
Latest Publications
- Open Access
- 7 May 2020
- Published by Gruppo Italiano Frattura in Fracture and Structural Integrity
- Vol. 14 (53) , 51-65
The Effect of corrosion on the quality repair of the aluminum alloy A 5083 H11 by bonded composites
In this paper, the effect of corrosion on the performance of the bonded composite patch repair in aluminum alloy A5083 marine structure was investigated using three dimensional finite element methods. To this end, two patches made in carbon/epoxy and boron/epoxy, bonded on corroded plates with and without crack, were tested under different applied loads. The effect of both corrosion and cracked materials on the damage of the adhesive FM73, was also highlighted. The obtained results show that, the corrosion has a significant effect on the quality repair performance. Indeed, it is proved that, the rate of damage increases with the increase of the applied load, and is more significant in the case of plates cracked and repaired by carbon/epoxy patch. Hence, the best performances were obtained using boron/epoxy patches
- 7 May 2020
- Published by Gruppo Italiano Frattura in Fracture and Structural Integrity
- Vol. 14 (53) , 51-65
Open AccessThe Effect of corrosion on the quality repair of the aluminum alloy A 5083 H11 by bonded composites
In this paper, the effect of corrosion on the performance of the bonded composite patch repair in aluminum alloy A5083 marine structure was investigated using three dimensional finite element methods. To this end, two patches made in carbon/epoxy and boron/epoxy, bonded on corroded plates with and without crack, were tested under different applied loads. The effect of both corrosion and cracked materials on the damage of the adhesive FM73, was also highlighted. The obtained results show that, the corrosion has a significant effect on the quality repair performance. Indeed, it is proved that, the rate of damage increases with the increase of the applied load, and is more significant in the case of plates cracked and repaired by carbon/epoxy patch. Hence, the best performances were obtained using boron/epoxy patches
- Open Access
- 31 March 2020
- Published by Gruppo Italiano Frattura in Fracture and Structural Integrity
- Vol. 14 (52) , 181-196
Finte element modeling of the behavior of polymethyl-methacrylate (PMMA) during high pressure torsion process.
High Pressure Torsion (HPT) is a highly effective super-plastic deformation process for obtaining nano-materials with high performance mechanical properties. In view of its optimization, it is of paramount importance to evaluate the relations between the behavior of the material under the effects of different processing parameters. In this context, this work aims to highlight the plastic strain distribution in the deformed material as a function of the hydrostatic pressure, the torsion angle and the temperature of the material applied during the process. A typical amorphous polymer (Polymethyl-Methacrylate: PMMA) has been tested. Firstly, in order to identify the material parameters of a phenomenological elasto-viscoplastic model compression tests at different temperatures and strain rates have been carried out. Then, the distributions of the effective plastic strain, the equivalent plastic strain rate and the hydrostatic stress were analyzed using finite elements method. Recommendations on process conditions were proclaimed at the end of this work according to the obtained numerical results.
- 31 March 2020
- Published by Gruppo Italiano Frattura in Fracture and Structural Integrity
- Vol. 14 (52) , 181-196
Open AccessFinte element modeling of the behavior of polymethyl-methacrylate (PMMA) during high pressure torsion process.
High Pressure Torsion (HPT) is a highly effective super-plastic deformation process for obtaining nano-materials with high performance mechanical properties. In view of its optimization, it is of paramount importance to evaluate the relations between the behavior of the material under the effects of different processing parameters. In this context, this work aims to highlight the plastic strain distribution in the deformed material as a function of the hydrostatic pressure, the torsion angle and the temperature of the material applied during the process. A typical amorphous polymer (Polymethyl-Methacrylate: PMMA) has been tested. Firstly, in order to identify the material parameters of a phenomenological elasto-viscoplastic model compression tests at different temperatures and strain rates have been carried out. Then, the distributions of the effective plastic strain, the equivalent plastic strain rate and the hydrostatic stress were analyzed using finite elements method. Recommendations on process conditions were proclaimed at the end of this work according to the obtained numerical results.
- Open Access
- 1 December 2019
- Published by Engineering, Technology & Applied Science Research in Engineering, Technology & Applied Science Research
- Vol. 9 (6) , 5093-5098
A Comparative Study of 316L Stainless Steel and a Titanium Alloy in an Aggressive Biological Medium
The electrochemical behavior of stainless steel and titanium alloys is affected after prolonged contact with basic or acidic solutions, indicating a change in their surface properties. The human body often rejects invasive devices that aim to alter the biological or chemical composition of blood or other body fluids. Stents, fixation plates and screws, spinal implant devices, aneurysm clips, intramedullary nails and stems, temporary fixation devices and surgical instruments, etc. have been made from stainless steel AISI 316L for several years. Although the mechanical performance of implants and devices may be governed by their bulk properties, their interaction with the environment is managed by the characteristics of their superficial layer. In the case of biomedical devices, resistance to corrosion and biocompatibility has paramount importance. This study compares the corrosion behavior of 316L stainless steel and a titanium alloy in a Hank solution. The obtained results show that the titanium alloy has a higher potential than 316L stainless steel and lower corrosion current.
- 1 December 2019
- Published by Engineering, Technology & Applied Science Research in Engineering, Technology & Applied Science Research
- Vol. 9 (6) , 5093-5098
Open AccessA Comparative Study of 316L Stainless Steel and a Titanium Alloy in an Aggressive Biological Medium
The electrochemical behavior of stainless steel and titanium alloys is affected after prolonged contact with basic or acidic solutions, indicating a change in their surface properties. The human body often rejects invasive devices that aim to alter the biological or chemical composition of blood or other body fluids. Stents, fixation plates and screws, spinal implant devices, aneurysm clips, intramedullary nails and stems, temporary fixation devices and surgical instruments, etc. have been made from stainless steel AISI 316L for several years. Although the mechanical performance of implants and devices may be governed by their bulk properties, their interaction with the environment is managed by the characteristics of their superficial layer. In the case of biomedical devices, resistance to corrosion and biocompatibility has paramount importance. This study compares the corrosion behavior of 316L stainless steel and a titanium alloy in a Hank solution. The obtained results show that the titanium alloy has a higher potential than 316L stainless steel and lower corrosion current.