Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Katiuska Rosas has a total of 30 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Transcranial optical monitoring for detecting intracranial pressure alterations in children with benign external hydrocephalus: a proof-of-concept study

    by Federica Maruccia, Susanna Tagliabue, Jonas B. Fischer, Michał Kacprzak, Santi Pérez-Hoyos, Katiuska Rosas, Ignacio Delgado Álvarez, Juan Sahuquillo, Turgut Durduran, Maria A. Poca

    Benign external hydrocephalus (BEH) is a condition usually diagnosed during the first year of life in infants presenting with macrocephaly or a rapidly increasing head circumference (HC). Neuroradiological findings show enlarged subarachnoid spaces—specifically at the frontotemporal lobes— and normal or moderately enlarged ventricles.1,2 BEH is commonly considered a self-limiting condition that does not require any treatment, but some children may present temporary or permanent psychomotor delays.3 – 7 Fine, gross motor and attentional skills have been identified as the most compromised developmental areas in infants with BEH.7 – 10 Additional complications, such as an increased risk of subdural hematoma and hypotonia, have also been reported.4,11,12


  • Neurodevelopmental profile in children with benign external hydrocephalus syndrome. A pilot cohort study

    by Federica Maruccia, Laura Gomáriz, Katiuska Rosas, Turgut Durduran, Fernando Paredes-Carmona, Juan Sahuquillo, Maria A. Poca

    Purpose The management of children with benign external hydrocephalus (BEH) remains controversial. Most BEH children do well in the long-term, but a substantial number have temporary or permanent psychomotor delays. The study aims to assess the prevalence and pattern of neurodevelopmental delay in a cohort of children with BEH. Methods We conducted a cohort study of 42 BEH children (30 boys and 12 girls, aged 6 to 38 months). A pediatric neurosurgeon performed a first clinical evaluation to confirm/reject the diagnosis according to the clinical features and neuroimaging studies. Two trained evaluators assessed the child’s psychomotor development using the third edition of the Bayley Scales of Infant and Toddler Development (Bayley-III). Developmental delay was defined as a scaled score < 7 according to the simple scale and/or a composite score < 85. Results Eighteen children (43%) presented statistically lower scores in the gross motor and composite motor of the Bayley-III scales compared to their healthy peers. Conclusion In BEH, it is important to establish a diagnostic algorithm that helps to discriminate BEH patients that have self-limiting delays from those at risk of a persistent delay that should be referred for additional studies and/or interventions that might improve the natural evolution of a disease with high impact on the children and adult’s quality of life.


  • Open Access

    How to Choose a Shunt for Patients with Normal Pressure Hydrocephalus: A Short Guide to Selecting the Best Shunt Assembly

    by Juan Sahuquillo, Katiuska Rosas, Helena Calvo, Aloma Alcina, Dario Gándara, Diego López-Bermeo, Maria-Antonia Poca

    Most patients with hydrocephalus are still managed with the implantation of a cerebrospinal fluid (CSF) shunt in which the CSF flow is regulated by a differential-pressure valve (DPV). Our aim in this review is to discuss some basic concepts in fluid mechanics that are frequently ignored but that should be understood by neurosurgeons to enable them to choose the most adequate shunt for each patient. We will present data, some of which is not provided by manufacturers, which may help neurosurgeons in selecting the most appropriate shunt. To do so, we focused on the management of patients with idiopathic “normal-pressure hydrocephalus” (iNPH), as one of the most challenging scenarios, in which the combination of optimal technology, patient characteristics, and knowledge of fluid mechanics can significantly modify the surgical results. For a better understanding of the available hardware and its evolution over time, we will have a second look at the design of the first DPV and the reasons why additional devices were incorporated to control for shunt overdrainage and its related complications. We try to persuade the reader that a clear understanding of the physical concepts of the CSF and shunt dynamics is key to understand the pathophysiology of iNPH and to improve its treatment.


  • Open Access

    Considerations in the Use of Gravitational Valves in the Management of Hydrocephalus. Some Lessons Learned with the Dual-Switch Valve

    by Maria A. Poca, Dario F. Gándara, Katiuska Rosas, Aloma Alcina, Diego López-Bermeo, Juan Sahuquillo

    In the past decade, there has been a clear trend towards better outcomes in patients with hydrocephalus, especially those with normal pressure hydrocephalus (NPH). This is partly due to the availability of more sophisticated hardware and a better understanding of implants. However, there is little evidence to show the superiority of a specific type of valve over another. The most commonly reported consequence of hydrodynamic mismatch is shunt over-drainage. Simple differential pressure valves, with a fixed opening pressure or even adjustable valves, lead to non-physiologic intraventricular pressure (IVP) as soon as the patient moves into an upright posture. These valves fail to maintain IVP within physiological limits due to the changes in hydrostatic pressure in the drainage system. To solve this problem more complex third-generation hydrostatic valves have been designed. These gravitational devices aim to reduce flow through a shunt system when the patient is upright but there are important technical differences between them. Here we review the main characteristics of the Miethke® Dual-Switch valve, which includes two valve chambers arranged in parallel: a low-opening pressure valve, designed for working in the supine position, and a second high-opening pressure valve, which starts working when the patient assumes the upright position. This paper specifies the main advantages and drawbacks of this device and provide a series of recommendations for its use. The discussion of this specific gravitational valve allows us to emphasize the importance of using gravitational control in implanted shunts and some the caveats neurosurgeons should take into consideration when using gravitational devices in patients with hydrocephalus. The correct function of any gravitational device depends on adequate device implantation along the vertical body axis. Misalignment from the vertical axis equal to or more than 45° might eliminate the beneficial effect of these devices.


  • Bilateral Optic Neuritis Secondary to Immune Etiology by anti-PD-L1 Antibody

    by Mikel Vicente-Pascual, Cristina Molins-Rojas, Katiuska Rosas-Soto, Eleonor P. Murata-Yonamine, Daniel Vázquez-Justes, Francisco Purroy, Alicia Traveset-Maeso


  • Distal catheter lengthening in pediatric patients with hydrocephalus using a guidewire-assisted technique

    by Maria A. Poca, Paola Cano, Francisca Munar, Diego González, Katiuska Rosas, Juan Sahuquillo

    Purpose The aim of this study was to evaluate the lengthening or replacement of the peritoneal catheter in a ventriculoperitoneal shunt by using a simple guidewire-assisted technique. Here we report on our experience with this methodology, its indications, caveats, and contraindications. Methods A prospective study was performed in 59 consecutively shunted children who required elective lengthening of the peritoneal catheter (25 females and 34 males, mean 10.5 + 4.2 years). The procedure required an incision of only 1 cm over the distal catheter. The catheter was sectioned, and a soft hydrophilic guidewire was inserted into the exposed end of it, which serves as a route for the guidewire to reach the intraperitoneal space. The procedure was followed by the replacement of the patient’s catheter with one with additional length as considered appropriate, prior to putting additional slots in the last 5 to 8 cm of the new catheter. Results The technique was used in 62 CSF shunts (3 patients had a double derivative system). Fifty-five of the 62 (89%) procedures performed were effective. A conventional peritoneal opening technique was used in the 7 unsuccessful attempts. One patient presented a migration of the abdominal catheter during the first days after surgery. No incident of peritoneal perforation was associated with this technique, nor were any infections or other early or late complications associated with this surgical procedure. Conclusion The technique we propose permits the peritoneal catheter of a derivative system to be lengthened or replaced in a manner that is simple, fast, and safe.

  • Spatial recognition memory in a virtual reality task is altered in refractory temporal lobe epilepsy

    by Katiuska Rosas, Isabel Parrón, Pedro Serrano, José Manuel Cimadevilla