Da Un Jeong
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Da Un Jeong has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
- Ki Moo Lim
Department of Biomedical Engineering, Kumoh National Institute of Technology, Gumi, Republic of Korea
8 shared publications - Aroli Marcellinus
Department of IT Convergence Engineering, Kumoh National Institute of Technology, Gumi 39253, Republic of Korea
2 shared publications - Jin Woo Chang
Department of Neurosurgery, Yonsei University College of Medicine, Seoul, Republic of Korea
2 shared publications - Abebe Tekle Abrha
Department of IT Convergence Engineering, Kumoh National Institute of Technology, Gumi, Korea
1 shared publication Aroli Marcellinus
Department of IT Convergence Engineering Kumoh National Institute of Technology Gumi Korea
1 shared publication- Aulia Khamas Heikhmakhtiar
School of Computing, Telkom University, Bandung, Indonesia
1 shared publication
Latest Publications
- Top Cited PapersOpen Access
- 1 August 2023
- Published by MDPI AG in Diagnostics
- Vol. 13 (15) , 2566
PPG Signals-Based Blood-Pressure Estimation Using Grid Search in Hyperparameter Optimization of CNN–LSTM
Researchers commonly use continuous noninvasive blood-pressure measurement (cNIBP) based on photoplethysmography (PPG) signals to monitor blood pressure conveniently. However, the performance of the system still needs to be improved. Accuracy and precision in blood-pressure measurements are critical factors in diagnosing and managing patients’ health conditions. Therefore, we propose a convolutional long short-term memory neural network (CNN–LSTM) with grid search ability, which provides a robust blood-pressure estimation system by extracting meaningful information from PPG signals and reducing the complexity of hyperparameter optimization in the proposed model. The multiparameter intelligent monitoring for intensive care III (MIMIC III) dataset obtained PPG and arterial-blood-pressure (ABP) signals. We obtained 75,226 signal segments, with 60,180 signals allocated for training data, 12,030 signals allocated for the validation set, and 15,045 signals allocated for the test data. During training, we applied five-fold cross-validation with a grid-search method to select the best model and determine the optimal hyperparameter settings. The optimized configuration of the CNN–LSTM layers consisted of five convolutional layers, one long short-term memory (LSTM) layer, and two fully connected layers for blood-pressure estimation. This study successfully achieved good accuracy in assessing both systolic blood pressure (SBP) and diastolic blood pressure (DBP) by calculating the standard deviation (SD) and the mean absolute error (MAE), resulting in values of 7.89 ± 3.79 and 5.34 ± 2.89 mmHg, respectively. The optimal configuration of the CNN–LSTM provided satisfactory performance according to the standards set by the British Hypertension Society (BHS), the Association for the Advancement of Medical Instrumentation (AAMI), and the Institute of Electrical and Electronics Engineers (IEEE) for blood-pressure monitoring devices.
- 1 August 2023
- Published by MDPI AG in Diagnostics
- Vol. 13 (15) , 2566
Top Cited PapersOpen AccessPPG Signals-Based Blood-Pressure Estimation Using Grid Search in Hyperparameter Optimization of CNN–LSTM
Researchers commonly use continuous noninvasive blood-pressure measurement (cNIBP) based on photoplethysmography (PPG) signals to monitor blood pressure conveniently. However, the performance of the system still needs to be improved. Accuracy and precision in blood-pressure measurements are critical factors in diagnosing and managing patients’ health conditions. Therefore, we propose a convolutional long short-term memory neural network (CNN–LSTM) with grid search ability, which provides a robust blood-pressure estimation system by extracting meaningful information from PPG signals and reducing the complexity of hyperparameter optimization in the proposed model. The multiparameter intelligent monitoring for intensive care III (MIMIC III) dataset obtained PPG and arterial-blood-pressure (ABP) signals. We obtained 75,226 signal segments, with 60,180 signals allocated for training data, 12,030 signals allocated for the validation set, and 15,045 signals allocated for the test data. During training, we applied five-fold cross-validation with a grid-search method to select the best model and determine the optimal hyperparameter settings. The optimized configuration of the CNN–LSTM layers consisted of five convolutional layers, one long short-term memory (LSTM) layer, and two fully connected layers for blood-pressure estimation. This study successfully achieved good accuracy in assessing both systolic blood pressure (SBP) and diastolic blood pressure (DBP) by calculating the standard deviation (SD) and the mean absolute error (MAE), resulting in values of 7.89 ± 3.79 and 5.34 ± 2.89 mmHg, respectively. The optimal configuration of the CNN–LSTM provided satisfactory performance according to the standards set by the British Hypertension Society (BHS), the Association for the Advancement of Medical Instrumentation (AAMI), and the Institute of Electrical and Electronics Engineers (IEEE) for blood-pressure monitoring devices.
- Open Access
- 30 January 2023
- Published by MDPI AG in Biomedicines
- Vol. 11 (2) , 406
Application of Convolutional Neural Networks Using Action Potential Shape for In-Silico Proarrhythmic Risk Assessment
This study proposes a convolutional neural network (CNN) model using action potential (AP) shapes as input for proarrhythmic risk assessment, considering the hypothesis that machine-learning features automatically extracted from AP shapes contain more meaningful information than do manually extracted indicators. We used 28 drugs listed in the comprehensive in vitro proarrhythmia assay (CiPA), consisting of eight high-risk, eleven intermediate-risk, and nine low-risk torsadogenic drugs. We performed drug simulations to generate AP shapes using experimental drug data, obtaining 2000 AP shapes per drug. The proposed CNN model was trained to classify the TdP risk into three levels, high-, intermediate-, and low-risk, based on in silico AP shapes generated using 12 drugs. We then evaluated the performance of the proposed model for 16 drugs. The classification accuracy of the proposed CNN model was excellent for high- and low-risk drugs, with AUCs of 0.914 and 0.951, respectively. The model performance for intermediate-risk drugs was good, at 0.814. Our proposed model can accurately assess the TdP risks of drugs from in silico AP shapes, reflecting the pharmacokinetics of ionic currents. We need to secure more drugs for future studies to improve the TdP-risk-assessment robustness.
- 30 January 2023
- Published by MDPI AG in Biomedicines
- Vol. 11 (2) , 406
Open AccessApplication of Convolutional Neural Networks Using Action Potential Shape for In-Silico Proarrhythmic Risk Assessment
This study proposes a convolutional neural network (CNN) model using action potential (AP) shapes as input for proarrhythmic risk assessment, considering the hypothesis that machine-learning features automatically extracted from AP shapes contain more meaningful information than do manually extracted indicators. We used 28 drugs listed in the comprehensive in vitro proarrhythmia assay (CiPA), consisting of eight high-risk, eleven intermediate-risk, and nine low-risk torsadogenic drugs. We performed drug simulations to generate AP shapes using experimental drug data, obtaining 2000 AP shapes per drug. The proposed CNN model was trained to classify the TdP risk into three levels, high-, intermediate-, and low-risk, based on in silico AP shapes generated using 12 drugs. We then evaluated the performance of the proposed model for 16 drugs. The classification accuracy of the proposed CNN model was excellent for high- and low-risk drugs, with AUCs of 0.914 and 0.951, respectively. The model performance for intermediate-risk drugs was good, at 0.814. Our proposed model can accurately assess the TdP risks of drugs from in silico AP shapes, reflecting the pharmacokinetics of ionic currents. We need to secure more drugs for future studies to improve the TdP-risk-assessment robustness.
- Open Access
- 1 November 2022
- Published by MDPI AG in Bioengineering
- Vol. 9 (11) , 628
Sensitivity Analysis of Cardiac Alternans and Tachyarrhythmia to Ion Channel Conductance Using Population Modeling
Action potential duration (APD) alternans, an alternating phenomenon between action potentials in cardiomyocytes, causes heart arrhythmia when the heart rate is high. However, some of the APD alternans observed in clinical trials occurs under slow heart rate conditions of 100 to 120 bpm, increasing the likelihood of heart arrhythmias such as atrial fibrillation. Advanced studies have identified the occurrence of this type of APD alternans in terms of electrophysiological ion channel currents in cells. However, they only identified physiological phenomena, such as action potential due to random changes in a particular ion channel’s conductivity through ion models specializing in specific ion channel currents. In this study, we performed parameter sensitivity analysis via population modeling using a validated human ventricular physiology model to check the sensitivity of APD alternans to ion channel conductances. Through population modeling, we expressed the changes in alternans onset cycle length (AOCL) and mean APD in AOCL (AO meanAPD) according to the variations in ion channel conductance. Finally, we identified the ion channel that maximally affected the occurrence of APD alternans. AOCL and AO meanAPD were sensitive to changes in the plateau Ca2+ current. Accordingly, it was expected that APD alternans would be vulnerable to changes in intracellular calcium concentration.
- 1 November 2022
- Published by MDPI AG in Bioengineering
- Vol. 9 (11) , 628
Open AccessSensitivity Analysis of Cardiac Alternans and Tachyarrhythmia to Ion Channel Conductance Using Population Modeling
Action potential duration (APD) alternans, an alternating phenomenon between action potentials in cardiomyocytes, causes heart arrhythmia when the heart rate is high. However, some of the APD alternans observed in clinical trials occurs under slow heart rate conditions of 100 to 120 bpm, increasing the likelihood of heart arrhythmias such as atrial fibrillation. Advanced studies have identified the occurrence of this type of APD alternans in terms of electrophysiological ion channel currents in cells. However, they only identified physiological phenomena, such as action potential due to random changes in a particular ion channel’s conductivity through ion models specializing in specific ion channel currents. In this study, we performed parameter sensitivity analysis via population modeling using a validated human ventricular physiology model to check the sensitivity of APD alternans to ion channel conductances. Through population modeling, we expressed the changes in alternans onset cycle length (AOCL) and mean APD in AOCL (AO meanAPD) according to the variations in ion channel conductance. Finally, we identified the ion channel that maximally affected the occurrence of APD alternans. AOCL and AO meanAPD were sensitive to changes in the plateau Ca2+ current. Accordingly, it was expected that APD alternans would be vulnerable to changes in intracellular calcium concentration.
- Open Access
- 17 May 2022
- Published by Wiley in CPT: Pharmacometrics & Systems Pharmacology
- Vol. 11 (5) , 653-664
Proarrhythmic risk assessment of drugs by dVm/dt shapes using the convolutional neural network
Comprehensive in vitro Proarrhythmia Assay (CiPA) projects for assessing proarrhythmic drugs suggested a logistic regression model using qNet as the Torsades de Pointes (TdP) risk assessment biomarker, obtained from in silico simulation. However, using a single in silico feature, such as qNet, cannot reflect whole characteristics related to TdP in the entire action potential (AP) shape. Thus, this study proposed a deep convolutional neural network (CNN) model using differential action potential shapes to classify three proarrhythmic risk levels: high, intermediate, and low, considering both characteristics related to TdP not only in the depolarization phase but also the repolarization phase of AP shape. We performed an in silico simulation and got AP shapes with drug effects using half‐maximal inhibitory concentration and Hill coefficients of 28 drugs released by CiPA groups. Then, we trained the deep CNN model with the differential AP shapes of 12 drugs and tested it with those of 16 drugs. Our model had a better performance for classifying the proarrhythmic risk of drugs than the traditional logistic regression model using qNet. The classification accuracy was 98% for high‐risk level drugs, 94% for intermediate‐risk level drugs, and 89% for low‐risk level drugs.
- 17 May 2022
- Published by Wiley in CPT: Pharmacometrics & Systems Pharmacology
- Vol. 11 (5) , 653-664
Open AccessProarrhythmic risk assessment of drugs by dVm/dt shapes using the convolutional neural network
Comprehensive in vitro Proarrhythmia Assay (CiPA) projects for assessing proarrhythmic drugs suggested a logistic regression model using qNet as the Torsades de Pointes (TdP) risk assessment biomarker, obtained from in silico simulation. However, using a single in silico feature, such as qNet, cannot reflect whole characteristics related to TdP in the entire action potential (AP) shape. Thus, this study proposed a deep convolutional neural network (CNN) model using differential action potential shapes to classify three proarrhythmic risk levels: high, intermediate, and low, considering both characteristics related to TdP not only in the depolarization phase but also the repolarization phase of AP shape. We performed an in silico simulation and got AP shapes with drug effects using half‐maximal inhibitory concentration and Hill coefficients of 28 drugs released by CiPA groups. Then, we trained the deep CNN model with the differential AP shapes of 12 drugs and tested it with those of 16 drugs. Our model had a better performance for classifying the proarrhythmic risk of drugs than the traditional logistic regression model using qNet. The classification accuracy was 98% for high‐risk level drugs, 94% for intermediate‐risk level drugs, and 89% for low‐risk level drugs.
- Open Access
- 16 March 2021
- Published by Wiley in Computational and Mathematical Methods in Medicine
- Vol. 2021, 1-5
Optimal Length of Heart Rate Variability Data and Forecasting Time for Ventricular Fibrillation Prediction Using Machine Learning
Ventricular fibrillation (VF) is a cardiovascular disease that is one of the major causes of mortality worldwide, according to the World Health Organization. Heart rate variability (HRV) is a biomarker that is used for detecting and predicting life-threatening arrhythmias. Predicting the occurrence of VF in advance is important for saving patients from sudden death. We extracted features from seven HRV data lengths to predict the onset of VF before nine different forecast times and observed the prediction accuracies. By using only five features, an artificial neural network classifier was trained and validated based on 10-fold cross-validation. Maximum prediction accuracies of 88.18% and 88.64% were observed at HRV data lengths of 10 and 20 s, respectively, at a forecast time of 0 s. The worst prediction accuracy was recorded at an HRV data length of 70 s and a forecast time of 80 s. Our results showed that features extracted from HRV signals near the VF onset could yield relatively high VF prediction accuracies.
- 16 March 2021
- Published by Wiley in Computational and Mathematical Methods in Medicine
- Vol. 2021, 1-5
Open AccessOptimal Length of Heart Rate Variability Data and Forecasting Time for Ventricular Fibrillation Prediction Using Machine Learning
Ventricular fibrillation (VF) is a cardiovascular disease that is one of the major causes of mortality worldwide, according to the World Health Organization. Heart rate variability (HRV) is a biomarker that is used for detecting and predicting life-threatening arrhythmias. Predicting the occurrence of VF in advance is important for saving patients from sudden death. We extracted features from seven HRV data lengths to predict the onset of VF before nine different forecast times and observed the prediction accuracies. By using only five features, an artificial neural network classifier was trained and validated based on 10-fold cross-validation. Maximum prediction accuracies of 88.18% and 88.64% were observed at HRV data lengths of 10 and 20 s, respectively, at a forecast time of 0 s. The worst prediction accuracy was recorded at an HRV data length of 70 s and a forecast time of 80 s. Our results showed that features extracted from HRV signals near the VF onset could yield relatively high VF prediction accuracies.
- Open Access
- 31 March 2020
- Published by Hindawi Limited in Computational and Mathematical Methods in Medicine
- Vol. 2020, 1-11
Computational Study to Identify the Effects of the KCNJ2 E299V Mutation in Cardiac Pumping Capacity
The KCNJ2 gene mutations induce short QT syndrome (SQT3) by directly increasing the IK1 current. There have been many studies on the electrophysiological effects of mutations such as the KCNJ2 D172N that cause the SQT3. However, the KCNJ2 E299V mutation is distinguished from other representative gene mutations that can induce the short QT syndrome (SQT3) in that it increased IK1 current by impairing the inward rectification of K+ channels. The studies of the electromechanical effects on myocardial cells and mechanisms of E299V mutations are limited. Therefore, we investigated the electrophysiological changes and the concomitant mechanical responses according to the expression levels of the KCNJ2 E299V mutation during sinus rhythm and ventricular fibrillation. We performed excitation-contraction coupling simulations using a human ventricular model with both electrophysiological and mechanical properties. In order to observe the electromechanical changes due to the expression of KCNJ2 E299V mutation, the simulations were performed under normal condition (WT), heterogeneous mutation condition (WT/E299V), and pure mutation condition (E299V). First, a single-cell simulation was performed in three types of ventricular cells (endocardial cell, midmyocardial cell, and epicardial cell) to confirm the electrophysiological changes and arrhythmogenesis caused by the KCNJ2 E299V mutation. In three-dimensional sinus rhythm simulations, we compared electrical changes and the corresponding changes in mechanical performance caused by the expression level of E299V mutation. Then, we observed the electromechanical properties of the E299V mutation during ventricular fibrillation using the three-dimensional reentry simulation. The KCNJ2 E299V mutation accelerated the opening of the IK1 channel and increased IK1 current, resulting in a decrease in action potential duration. Accordingly, the QT interval was reduced by 48 and 60 compared to the WT condition, for the WT/E299V and E299V conditions, respectively. During sustained reentry, the wavelength was reduced due to the KCNJ2 E299V mutation. Furthermore, there was almost no ventricular contraction in both WT/E299V and E299V conditions. We concluded that in both sinus rhythm and fibrillation, the KCNJ2 E299V mutation results in very low contractility regardless of the expression level of mutation and increases the risk of cardiac arrest and cardiac death.
- 31 March 2020
- Published by Hindawi Limited in Computational and Mathematical Methods in Medicine
- Vol. 2020, 1-11
Open AccessComputational Study to Identify the Effects of the KCNJ2 E299V Mutation in Cardiac Pumping Capacity
The KCNJ2 gene mutations induce short QT syndrome (SQT3) by directly increasing the IK1 current. There have been many studies on the electrophysiological effects of mutations such as the KCNJ2 D172N that cause the SQT3. However, the KCNJ2 E299V mutation is distinguished from other representative gene mutations that can induce the short QT syndrome (SQT3) in that it increased IK1 current by impairing the inward rectification of K+ channels. The studies of the electromechanical effects on myocardial cells and mechanisms of E299V mutations are limited. Therefore, we investigated the electrophysiological changes and the concomitant mechanical responses according to the expression levels of the KCNJ2 E299V mutation during sinus rhythm and ventricular fibrillation. We performed excitation-contraction coupling simulations using a human ventricular model with both electrophysiological and mechanical properties. In order to observe the electromechanical changes due to the expression of KCNJ2 E299V mutation, the simulations were performed under normal condition (WT), heterogeneous mutation condition (WT/E299V), and pure mutation condition (E299V). First, a single-cell simulation was performed in three types of ventricular cells (endocardial cell, midmyocardial cell, and epicardial cell) to confirm the electrophysiological changes and arrhythmogenesis caused by the KCNJ2 E299V mutation. In three-dimensional sinus rhythm simulations, we compared electrical changes and the corresponding changes in mechanical performance caused by the expression level of E299V mutation. Then, we observed the electromechanical properties of the E299V mutation during ventricular fibrillation using the three-dimensional reentry simulation. The KCNJ2 E299V mutation accelerated the opening of the IK1 channel and increased IK1 current, resulting in a decrease in action potential duration. Accordingly, the QT interval was reduced by 48 and 60 compared to the WT condition, for the WT/E299V and E299V conditions, respectively. During sustained reentry, the wavelength was reduced due to the KCNJ2 E299V mutation. Furthermore, there was almost no ventricular contraction in both WT/E299V and E299V conditions. We concluded that in both sinus rhythm and fibrillation, the KCNJ2 E299V mutation results in very low contractility regardless of the expression level of mutation and increases the risk of cardiac arrest and cardiac death.
- Open Access
- 1 January 2020
- Published by XMLink in Journal of Korean Medical Science
- Vol. 35 (29) , e238
Proarrhythmogenic Effect of the L532P and N588K KCNH2 Mutations in the Human Heart Using a 3D Electrophysiological Model
Heikhmakhtiar AK, et al. J Korean Med Sci. 2020 Jun;35(29):e238. https://doi.org/10.3346/jkms.2020.35.e238
- 1 January 2020
- Published by XMLink in Journal of Korean Medical Science
- Vol. 35 (29) , e238
Open AccessProarrhythmogenic Effect of the L532P and N588K KCNH2 Mutations in the Human Heart Using a 3D Electrophysiological Model
Heikhmakhtiar AK, et al. J Korean Med Sci. 2020 Jun;35(29):e238. https://doi.org/10.3346/jkms.2020.35.e238
- Open Access
- 15 June 2018
- Published by Springer Nature in BioMedical Engineering OnLine
- Vol. 17 (1) , 79
The effect of myocardial action potential duration on cardiac pumping efficacy: a computational study
Although studies on the relation between arrhythmias and the action potential duration (APD) have been carried out, most of them are based only on electrophysiological factors of the heart and lack experiments that consider cardiac mechanical and electromechanical characteristics. Therefore, we conducted this study to clarify the relevance of the shortening of APD of a cell in relation to the mechanical contraction activity of the heart and the associated risk of arrhythmia. The human ventricular model used in this study has two dynamic characteristics: electrophysiological conduction and mechanical contraction. The model simulating electrophysiological characteristics was consisted of lumped parameter circuit that can mimic the phenomenon of ion exchange through the cell membrane of myocyte and consisted of 214,319 tetrahedral finite elements. In contrast, the model simulating mechanical contraction characteristics was constructed to mimic cardiac contraction by means of the crossbridge of a myofilament and consisted of 14,720 hermite-based finite elements to represent a natural 3D curve of the cardiac surface. First, we performed a single cell simulation and the electrophysiological simulation according to the change of the APD by changing the electrical conductivity of the I Ks channel. Thus, we confirmed the correlation between APD and intracellular Ca2+ concentration. Then, we compared mechanical response through mechanical simulation using Ca2+ data from electrical simulation. The APD and the sum of the intracellular Ca2+ concentrations showed a positive correlation. The shortened APD reduced the conduction wavelength of ventricular cells by shortening the plateau and early repolarization in myocardial cells. The decrease in APD reduced ventricular pumping efficiency by more than 60% as compared with the normal group (normal conditions). This change is caused by the decline of ventricular output owing to reduced ATP consumption during the crossbridge of myofilaments and decreased tension. The shortening of APD owing to increased electrical conductivity of a protein channel on myocardial cells likely decreases the wavelength and the pumping efficiency of the ventricles. Additionally, it may increase tissue sensitivity to ventricular fibrillation, including reentry, and cause symptoms such as dyspnea and dizziness.
- 15 June 2018
- Published by Springer Nature in BioMedical Engineering OnLine
- Vol. 17 (1) , 79
Open AccessThe effect of myocardial action potential duration on cardiac pumping efficacy: a computational study
Although studies on the relation between arrhythmias and the action potential duration (APD) have been carried out, most of them are based only on electrophysiological factors of the heart and lack experiments that consider cardiac mechanical and electromechanical characteristics. Therefore, we conducted this study to clarify the relevance of the shortening of APD of a cell in relation to the mechanical contraction activity of the heart and the associated risk of arrhythmia. The human ventricular model used in this study has two dynamic characteristics: electrophysiological conduction and mechanical contraction. The model simulating electrophysiological characteristics was consisted of lumped parameter circuit that can mimic the phenomenon of ion exchange through the cell membrane of myocyte and consisted of 214,319 tetrahedral finite elements. In contrast, the model simulating mechanical contraction characteristics was constructed to mimic cardiac contraction by means of the crossbridge of a myofilament and consisted of 14,720 hermite-based finite elements to represent a natural 3D curve of the cardiac surface. First, we performed a single cell simulation and the electrophysiological simulation according to the change of the APD by changing the electrical conductivity of the I Ks channel. Thus, we confirmed the correlation between APD and intracellular Ca2+ concentration. Then, we compared mechanical response through mechanical simulation using Ca2+ data from electrical simulation. The APD and the sum of the intracellular Ca2+ concentrations showed a positive correlation. The shortened APD reduced the conduction wavelength of ventricular cells by shortening the plateau and early repolarization in myocardial cells. The decrease in APD reduced ventricular pumping efficiency by more than 60% as compared with the normal group (normal conditions). This change is caused by the decline of ventricular output owing to reduced ATP consumption during the crossbridge of myofilaments and decreased tension. The shortening of APD owing to increased electrical conductivity of a protein channel on myocardial cells likely decreases the wavelength and the pumping efficiency of the ventricles. Additionally, it may increase tissue sensitivity to ventricular fibrillation, including reentry, and cause symptoms such as dyspnea and dizziness.
- Open Access
- 1 January 2018
- Published by XMLink in Yonsei Medical Journal
- Vol. 59 (3) , 406-415
Effect of Placenta-Derived Mesenchymal Stem Cells in a Dementia Rat Model via Microglial Mediation: a Comparison between Stem Cell Transplant Methods
Cho JS, et al. Yonsei Med J. 2018 May;59(3):406-415. https://doi.org/10.3349/ymj.2018.59.3.406
- 1 January 2018
- Published by XMLink in Yonsei Medical Journal
- Vol. 59 (3) , 406-415
Open AccessEffect of Placenta-Derived Mesenchymal Stem Cells in a Dementia Rat Model via Microglial Mediation: a Comparison between Stem Cell Transplant Methods
Cho JS, et al. Yonsei Med J. 2018 May;59(3):406-415. https://doi.org/10.3349/ymj.2018.59.3.406