COCarlos Osorno-Cruz

Carlos Osorno-Cruz

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Carlos Osorno-Cruz has a total of 37 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

    • 16 August 2022
      • Vol. 4  (2)
    Open Access

    Venous Outflow for Brain Arteriovenous Malformations: Overview and Treatment Implications.

    by C Osorno-Cruz, Z Hasanpour, R Peart, W Dodd, D Laurent, S Aghili-Mehrizi, B Lucke-Wold, N Chalouhi

    Recent evidence has demonstrated a close relationship between the cerebral venous and lymphatic systems. Venous congestion has been implicated in a host of neurologic disorders, with relevance for vascular etiologies. The authors aim to review the literature as it pertains to brain arteriovenous malformations' (BAVMs) venous hemodynamics and glymphatic pathways, as well as the implications of BAVM treatment. BAVMs offer a unique challenge, with sudden alteration in flow dynamics leading to increased hemorrhage risk and difficult challenges post-treatment. Recent progress in the understanding of CNS fluid dynamics and glymphatic pathways have revealed important implications for BAVM pathology and treatment. As imaging techniques and treatment modalities advance, there is a need to further investigate this relationship as it relates to therapeutic options and post-treatment sequalae.

  • 3D aneurysm wall enhancement is associated with symptomatic presentation

    by Ashrita Raghuram, Sebastian Sanchez, Linder Wendt, Steven Cochran, Daizo Ishii, Carlos Osorno, Girish Bathla, Timothy R Koscik, James Torner, David Hasan, et al.

    Background Aneurysm wall enhancement (AWE) is a potential surrogate biomarker for aneurysm instability. Previous studies have assessed AWE using 2D multiplanar methods, most of which were conducted qualitatively. Objective To use a new quantitative tool to analyze a large cohort of saccular aneurysms with 3D-AWE maps Methods Saccular aneurysms were imaged prospectively with 3T high resolution MRI. 3D-AWE maps of symptomatic (defined as ruptured or presentation with sentinel headache/cranial nerve neuropathy) and asymptomatic aneurysms were created by extending orthogonal probes from the aneurysm lumen into the wall. Three metrics were used to characterize enhancement: 3D circumferential AWE (3D-CAWE), aneurysm-specific contrast uptake (SAWE), and focal AWE (FAWE). Aneurysms with a circumferential AWE higher than the corpus callosum (3D-CAWE ≥1) were classified as 3D-CAWE+. Symptomatic presentation was analyzed with univariate and multivariate logistic models. Aneurysm size, size ratio, aspect ratio, irregular morphology, and PHASES and ELAPSS scores were compared with the new AWE metrics. Bleb and microhemorrhage analyses were also performed. Results Ninety-three aneurysms were analyzed. 3D-CAWE, SAWE, and FAWE were associated with symptomatic status (OR=1.34, 1.25, and 1.08, respectively). A multivariate model including aneurysm size, 3D-CAWE+, age, female gender, and FAWE detected symptomatic status with 80% specificity and 90% sensitivity (area under the curve=0.914, =0.967). FAWE was also associated with irregular morphology and high-risk location (p=0.043 and p=0.001, respectively). In general, blebs enhanced 56% more than the aneurysm body. Areas of microhemorrhage co-localized with areas of increased SAWE (p=0.047). Conclusions 3D-AWE mapping provides a new set of metrics that could potentially improve the identification of symptomatic aneurysms.


  • Open Access

    Single surgeon experience with minimally invasive supraorbital craniotomy versus bifrontal craniotomy for anterior skull base meningiomas

    by Scott Christopher Seaman, Muhammad Salman Ali, Anthony Marincovich, Carlos Osorno-Cruz, Jeremy D. W. Greenlee

    Background: Anterior skull base meningiomas (ASBMs) account for about 10% of meningiomas. Bifrontal craniotomy (BFC) represents the traditional transcranial approach to accessing meningiomas in these locations. Supraorbital craniotomy (SOC) provides a minimally invasive subfrontal corridor in select patients. Here, we present our series of ASBM accessed by SOC and BFC by a single surgeon to review decision-making and compare outcomes in both techniques. Methods: Thirty-three patients were identified with ASBM. Age, tumor characteristics, presenting symptoms, postoperative complications, and outcomes were analyzed. Results: Bifrontal and SOC were performed in 13 and 20 patients, respectively. Mean follow-up time was 98.4 months. Patients undergoing SOC had smaller tumor size, located farther from the posterior table of frontal sinus, had less peritumoral edema, and decreased length of stay compared to patients undergoing BFC. Extent of resection was slightly better with BFC (99.8%) compared to SOC (91.8%), although this difference did not reach statistical significance. Recurrence-free survival and rate of re-do surgeries were not different between two groups. BFC was associated with higher rates of postoperative encephalomalacia. Conclusion: SOC provides an excellent surgical option for ASBMs providing comparable extent of resection, minimal manipulation of brain, and excellent cosmetic outcomes for patients. The patient selection is key to maximize the benefits from this approach.


  • Open Access

    Quantitative Susceptibility Mapping and Vessel Wall Imaging as Screening Tools to Detect Microbleed in Sentinel Headache

    by Daizo Ishii, Daichi Nakagawa, Mario Zanaty, Jorge A. Roa, Sami Al Kasab, Amir Shaban, Joseph S. Hudson, Carlos Osorno-Cruz, Stefano Byer, Lauren Allan, et al.

    Background: MR-quantitative susceptibility mapping (QSM) can identify microbleeds (MBs) in intracranial aneurysm (IA) wall associated with sentinel headache (SH) preceding subarachnoid hemorrhage. However, its use is limited, due to associated skull base bonny and air artifact. MR-vessel wall imaging (VWI) is not limited by such artifact and therefore could be an alternative to QSM. The purpose of this study was to investigate the correlation between QSM and VWI in detecting MBs and to help develop a diagnostic strategy for SH. Methods: We performed a prospective study of subjects with one or more unruptured IAs in our hospital. All subjects underwent evaluation using 3T-MRI for MR angiography (MRA), QSM, and pre- and post-contrast VWI of the IAs. Presence/absence of MBs detected by QSM was correlated with aneurysm wall enhancement (AWE) on VWI. Results: A total of 40 subjects harboring 51 unruptured IAs were enrolled in the study. MBs evident on the QSM sequence was detected in 12 (23.5%) IAs of 11 subjects. All these subjects had a history of severe headache suggestive of SH. AWE was detected in 22 (43.1%) IAs. Using positive QSM as a surrogate for MBs, the sensitivity, specificity, positive predictive value, and negative predictive value of AWE on VWI for detecting MBs were 91.7%, 71.8%, 50%, and 96.6%, respectively. Conclusions: Positive QSM findings strongly suggested the presence of MBs with SH, whereas, the lack of AWE on VWI can rule it out with a probability of 96.6%. If proven in a larger cohort, combining QSM and VWI could be an adjunctive tool to help diagnose SH, especially in cases with negative or non-diagnostic CT and lumbar puncture.


  • Objective quantification of contrast enhancement of unruptured intracranial aneurysms: a high-resolution vessel wall imaging validation study

    by Jorge A. Roa, Mario Zanaty, Carlos Osorno-Cruz, Daizo Ishii, Girish Bathla, Santiago Ortega-Gutierrez, David M. Hasan, Edgar A. Samaniego

    OBJECTIVE: High-resolution vessel wall imaging (HR-VWI) has emerged as a valuable tool in assessing unruptured intracranial aneurysms (UIAs). There is no standardized method to quantify contrast enhancement of the aneurysm wall. Contrast enhancement can be objectively measured as signal intensity (SI) or subjectively adjudicated. In this study, the authors compared the different methods to quantify wall enhancement of UIAs and determined the sensitivity and specificity of each method as a surrogate of aneurysm instability. They also compared SI quantification between scanners from different manufacturers. METHODS: The University of Iowa HR-VWI Project database was analyzed. This database compiles patients with UIAs who prospectively underwent HR-VWI using a 3T MRI scanner. The mean and maximal SI values of the aneurysm wall, pituitary stalk, and genu of the corpus callosum were used to compare 3 different measurement methods: 1) aneurysm enhancement ratio AER = (SI wall post − SI wall pre )/SI wall pre ; 2) aneurysm-to–pituitary stalk contrast ratio CR stalk = SI wall post /SI stalk post ; and 3) aneurysm enhancement index AEI = ([SI wall post /SI brain post ] − [SI wall pre /SI brain pre ])/(SI wall pre /SI brain pre ) (where “pre” indicates precontrast images and “post” indicates postcontrast images). Size ≥ 7 mm was used as a surrogate of aneurysm instability for receiver operating characteristic (ROC) curve analysis. To determine if the objective quantification of SI varies among scanners from different manufacturers, 9 UIAs underwent the same HR-VWI protocol using a 3T General Electric (GE) scanner and a 3T Siemens scanner. Three UIAs also underwent a third scanning procedure on a unit with a different magnet strength (7T GE). RESULTS: Eighty patients with 102 UIAs were included in the study. The mean age was 64.5 ± 12.2 years, and 64 (80%) patients were women. UIAs ≥ 7 mm had significantly higher SIs than smaller UIAs (< 7 mm): AER = 0.82 vs 0.49, p < 0.001; CR stalk = 0.84 vs 0.61, p < 0.001; and AEI = 0.81 vs 0.48, p < 0.001. ROC curves demonstrated optimal sensitivity of 81.5% for CR stalk ≥ 0.60, 75.9% for AEI ≥ 0.50, and 74.1% for AER ≥ 0.49. Intermanufacturer correlation between 3T GE and 3T Siemens MRI scanners for CR stalk using mean and maximal SI values was excellent (Pearson coefficients > 0.80, p < 0.001). A similar correlation was identified among the 3 UIAs that underwent 7T imaging. CONCLUSIONS: CR stalk using maximal SI values was the most reliable objective method to quantify enhancement of UIAs on HR-VWI. The same ratios were obtained between different manufacturers and on scans obtained using magnets of different strengths.