Jyh-Horng Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jyh-Horng Wang has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Po-Quang Chen
Department of Orthopedic Surgery, National Taiwan University Hospital, Taipei 100, Taiwan
2 shared publications - Yi-You Huang
Department of Biomedical Engineering, College of Medicine, College of Engineering, National Taiwan University, Taipei, Taiwan
2 shared publications - Chen-Sheng Chen
Department of Physical Therapy and Assistive Technology, National Yang Ming Chiao Tung University, Taipei 112304, Taiwan
1 shared publication - Jui-Yang Hsieh
Department of Biomedical Engineering, National Taiwan University, Taipei, Taiwan (R.O.C.)
1 shared publication - Jui-Yang Hsieh
Department of Biomedical Engineering, National Taiwan University, Taipei 100, Taiwan
1 shared publication - Shao-Ming Chuang
Department of Physical Therapy and Assistive Technology, National Yang Ming Chiao Tung University, Taipei 112, Taiwan
1 shared publication
Latest Publications
- Open Access
- 19 November 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (22) , 11759
Comparison of the Optimal Design of Spinal Hybrid Elastic Rod for Dynamic Stabilization: A Finite Element Analysis
The spinal hybrid elastic (SHE) rod is a semi-rigid pedicle screw-based rod for spinal dynamic stabilization. This study investigated the biomechanical effects of different ratios of SHE rod using finite element analysis (FEA). A three-dimensional nonlinear FEA of an intact lumbar spine model (INT) was constructed. The SHE rod was composed of an inner nitinol stick (NS) and an outer polycarbonate urethane shell (PS). Four groups implanted at L3–L4 had the same outer diameter (5.5 mm) but different NS diameter/PS thickness ratios: Nt45, Nt35, Nt25, and Nt15. The resultant intervertebral range of motion (ROM), disc stress, facet joint contact force, screw stress, NS stress, and PCU stress were analyzed. The results indicated that ROM, disc stress, and facet force decreased moderately in the implanted L3–L4 levels and increased slightly in the adjacent L2–L3 levels. The NS stress and NS diameter trended towards inverse proportionality. Changing the ratio did not markedly influence screw or PS stress. The SHE rod system with elastic NS and insulated PS has a 5.5 mm diameter for universal pedicle screws. The SHE rod system provides sufficient spinal support and increases gentle adjacent segment stress. Considering the durability, the optimal NS diameter/PS thickness ratio of the SHE rod system is 3.5/2.0 mm.
- 19 November 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (22) , 11759
Open AccessComparison of the Optimal Design of Spinal Hybrid Elastic Rod for Dynamic Stabilization: A Finite Element Analysis
The spinal hybrid elastic (SHE) rod is a semi-rigid pedicle screw-based rod for spinal dynamic stabilization. This study investigated the biomechanical effects of different ratios of SHE rod using finite element analysis (FEA). A three-dimensional nonlinear FEA of an intact lumbar spine model (INT) was constructed. The SHE rod was composed of an inner nitinol stick (NS) and an outer polycarbonate urethane shell (PS). Four groups implanted at L3–L4 had the same outer diameter (5.5 mm) but different NS diameter/PS thickness ratios: Nt45, Nt35, Nt25, and Nt15. The resultant intervertebral range of motion (ROM), disc stress, facet joint contact force, screw stress, NS stress, and PCU stress were analyzed. The results indicated that ROM, disc stress, and facet force decreased moderately in the implanted L3–L4 levels and increased slightly in the adjacent L2–L3 levels. The NS stress and NS diameter trended towards inverse proportionality. Changing the ratio did not markedly influence screw or PS stress. The SHE rod system with elastic NS and insulated PS has a 5.5 mm diameter for universal pedicle screws. The SHE rod system provides sufficient spinal support and increases gentle adjacent segment stress. Considering the durability, the optimal NS diameter/PS thickness ratio of the SHE rod system is 3.5/2.0 mm.
- 24 March 2022
- Published by Springer Nature in Journal of Medical and Biological Engineering
- Vol. 42 (2) , 196-203
Comparison of Osseointegration in Different Intravertebral Fixators
- 24 March 2022
- Published by Springer Nature in Journal of Medical and Biological Engineering
- Vol. 42 (2) , 196-203
Comparison of Osseointegration in Different Intravertebral Fixators