Yina F. Jiménez Cerón
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Yina F. Jiménez Cerón has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Carlos Arturo Madera Parra
Grupo de Investigación de Estudio y Control de la Contaminación Ambiental (ECCA), Universidad del Valle, Cali, Colombia
1 shared publication - Carolina Fernández Tulande1 shared publication
- Edwin Rengifo Canizales1 shared publication
- Huber M. Pino Alegría1 shared publication
- Jaime Lara-Borrero
Department of Civil Engineering, Pontificia Universidad Javeriana, Bogotá 110231, Colombia
1 shared publication John R. Agudelo
Grupo de Manejo Eficiente de La Energía -GIMEL, Facultad de Ingeniería, Universidad de Antioquia UdeA, Medellín, Colombia
1 shared publication
Latest Publications
- 1 June 2025
- Published by Springer Nature in Environmental Science and Pollution Research
- Vol. 32 (29) , 17760-17775
Impact of C1–C5 fumigated alcohols as low-carbon diesel fuel substitutes on carbonyl emissions
Alcohols are promising renewable low-carbon fuels; however, there is concern regarding the increased emission of toxic oxygenated compounds, particularly when the alcohols are fumigated into the intake manifold instead of blended with the substituted fuel. This study investigates the impact of fumigating C1 to C5 alcohols on the emission of carbonyl compounds from an automotive diesel engine operating on methanol (M), ethanol (E), butanol (Bu), and pentanol (Pe). The alcohols were used to substitute 10% and 20% of the engine’s power output under typical urban driving conditions. Exhaust gases were sampled using 2,4-dinitrophenylhydrazine cartridges, followed by extraction with acetonitrile and quantification via HPLC–UV. The results indicate that both the type of alcohol and the extent of power output substitution significantly increased carbonyl emissions compared to the base fuel (B10). Specifically, M and E caused substantial increases in formaldehyde levels, with percentage increases ranging from 223 to 439% (650–1086 mg/kWh) for M and 51–195% (303–594 mg/kWh) for E at 10% and 20% power-output substitution, respectively. A dramatic rise in acetaldehyde emissions was observed with E, with an increase of 11,058% (2643 mg/kWh) for E10 and 13,934% (3229 mg/kWh) for E20. Bu, on the other hand, primarily increased emissions of butyraldehyde and benzaldehyde, with increases of 2415–3312% (195–264 mg/kWh). In addition, significant increases in acetaldehyde, acrolein, and propionaldehyde were observed. Pe, tested only at 10% power-output substitution (Pe10), resulted in a three-fold increase in acetaldehyde emissions (740 mg/kWh) and a 370% increase in propionaldehyde (35 mg/kWh) compared to the base fuel. Furthermore, a previously undetected aromatic carbonyl compound, p-tolualdehyde (301 mg/kWh), was identified. The total carbonyl emissions with partial substitution of C1–C5 alcohols followed this order (in mg/kWh): E (2987–3868) > Pe (1249) > M (724–1147) > Bu (684–761) > B10 (270). These findings indicate the need for careful consideration when using energy-substituted alcohols in diesel engines, where the implementation of dedicated carbonyl-catalyst systems should also be considered to mitigate the impact of the measured emissions. Graphical abstract
- 1 June 2025
- Published by Springer Nature in Environmental Science and Pollution Research
- Vol. 32 (29) , 17760-17775
Impact of C1–C5 fumigated alcohols as low-carbon diesel fuel substitutes on carbonyl emissions
Alcohols are promising renewable low-carbon fuels; however, there is concern regarding the increased emission of toxic oxygenated compounds, particularly when the alcohols are fumigated into the intake manifold instead of blended with the substituted fuel. This study investigates the impact of fumigating C1 to C5 alcohols on the emission of carbonyl compounds from an automotive diesel engine operating on methanol (M), ethanol (E), butanol (Bu), and pentanol (Pe). The alcohols were used to substitute 10% and 20% of the engine’s power output under typical urban driving conditions. Exhaust gases were sampled using 2,4-dinitrophenylhydrazine cartridges, followed by extraction with acetonitrile and quantification via HPLC–UV. The results indicate that both the type of alcohol and the extent of power output substitution significantly increased carbonyl emissions compared to the base fuel (B10). Specifically, M and E caused substantial increases in formaldehyde levels, with percentage increases ranging from 223 to 439% (650–1086 mg/kWh) for M and 51–195% (303–594 mg/kWh) for E at 10% and 20% power-output substitution, respectively. A dramatic rise in acetaldehyde emissions was observed with E, with an increase of 11,058% (2643 mg/kWh) for E10 and 13,934% (3229 mg/kWh) for E20. Bu, on the other hand, primarily increased emissions of butyraldehyde and benzaldehyde, with increases of 2415–3312% (195–264 mg/kWh). In addition, significant increases in acetaldehyde, acrolein, and propionaldehyde were observed. Pe, tested only at 10% power-output substitution (Pe10), resulted in a three-fold increase in acetaldehyde emissions (740 mg/kWh) and a 370% increase in propionaldehyde (35 mg/kWh) compared to the base fuel. Furthermore, a previously undetected aromatic carbonyl compound, p-tolualdehyde (301 mg/kWh), was identified. The total carbonyl emissions with partial substitution of C1–C5 alcohols followed this order (in mg/kWh): E (2987–3868) > Pe (1249) > M (724–1147) > Bu (684–761) > B10 (270). These findings indicate the need for careful consideration when using energy-substituted alcohols in diesel engines, where the implementation of dedicated carbonyl-catalyst systems should also be considered to mitigate the impact of the measured emissions. Graphical abstract
- Open Access
- 1 July 2018
- Published by Universidad de Ciencias Aplicadas Y Ambientales - UDCA in Revista U.D.C.A Actualidad & Divulgación Científica
- Vol. 21 (2)
Tratamiento de lixiviados utilizando humedales construidos y determinación de conductividades hidráulicas en clima tropical
In recent years, constructed wetlands have been widely used for the purification of wastewater, representing an alternative method that offers multiple advantages when compared to other treatment systems. The present study assessed the efficiency of six horizontal subsurface flow constructed wetlands (HSSFCW) at pilot scale for the removal of organic matter (COD), nutrients (N-NO3-, P-PO43-) and lead (Pb2+). The study also looked at the operating time on hydraulic conductivity (Ks) to treat leachate from the "El Ojito" Sanitary Landfill in the municipality of Popayán, Cauca. Three wetlands were planted with Heliconia psittacorum (HSSFCW-H. p), and three with Cyperus haspan (HSSFCW-C. h). The support medium used was gravel. They were operated at a flow of 0.012m3/day, and a hydraulic retention time of 4 days. The units received effluent from the oxidation pond. The results showed mean removals of COD (51.67 and 64.00%), N-NO3- (45.33 and 48.17%), P-PO43- (53.67 and 62.67%) and Pb+2 (5.74 and 14.75%) for HSSFCW-H. p and HSSFCW-C. h respectively. Hydraulic conductivity values were between 700 and 1000m/day. The wetland system proved to be efficient for the secondary treatment of leachate from mature landfills, obtaining removal efficiencies significantly higher in HSSFCW-C. h. Los humedales construidos en los últimos años han sido ampliamente usados en la depuración de una gran variedad de aguas residuales, por ser una alternativa que ofrece múltiples ventajas, en comparación con otros sistemas de tratamiento. Este estudio evaluó la eficiencia de seis sistemas de humedales, construidos de flujo subsuperficial horizontal (HCFSSH), a escala piloto, para la remoción de materia orgánica (DQO), nutrientes (N-NO3-, P-PO43-) y plomo (Pb+2), además de la incidencia del tiempo de operación sobre la conductividad hidráulica (Ks) para tratar lixiviados del Relleno Sanitario “El Ojito”, del municipio de Popayán, Cauca. Tres humedales fueron plantados con Heliconia psittacorum (HCFSSH-H. p) y tres con Cyperus haspan (HCFSSH-C. h); el medio de soporte utilizado fue grava, operados con un caudal de 0.012m3/día y un tiempo de retención hidráulico de 4 días; las unidades recibieron efluente de una laguna de oxidación. Los resultados mostraron remociones medias de: DQO (51,67 y 64,00%), N-NO3- (45,33 y 48,17%), P-PO43- (53,67 y 62,67%) y Pb+2 (5,74 y 14,75%) para los HCFSSH-H. p y HCFSSH-C. h, respectivamente y valores de conductividad hidráulica, entre 700 y 1000m/día. El sistema de humedales mostró ser eficiente para el tratamiento secundario de lixiviado de rellenos sanitarios maduros, obteniendo eficiencias de remoción, significativamente mayores, en los HCFSSH-C. h.
- 1 July 2018
- Published by Universidad de Ciencias Aplicadas Y Ambientales - UDCA in Revista U.D.C.A Actualidad & Divulgación Científica
- Vol. 21 (2)
Open AccessTratamiento de lixiviados utilizando humedales construidos y determinación de conductividades hidráulicas en clima tropical
In recent years, constructed wetlands have been widely used for the purification of wastewater, representing an alternative method that offers multiple advantages when compared to other treatment systems. The present study assessed the efficiency of six horizontal subsurface flow constructed wetlands (HSSFCW) at pilot scale for the removal of organic matter (COD), nutrients (N-NO3-, P-PO43-) and lead (Pb2+). The study also looked at the operating time on hydraulic conductivity (Ks) to treat leachate from the "El Ojito" Sanitary Landfill in the municipality of Popayán, Cauca. Three wetlands were planted with Heliconia psittacorum (HSSFCW-H. p), and three with Cyperus haspan (HSSFCW-C. h). The support medium used was gravel. They were operated at a flow of 0.012m3/day, and a hydraulic retention time of 4 days. The units received effluent from the oxidation pond. The results showed mean removals of COD (51.67 and 64.00%), N-NO3- (45.33 and 48.17%), P-PO43- (53.67 and 62.67%) and Pb+2 (5.74 and 14.75%) for HSSFCW-H. p and HSSFCW-C. h respectively. Hydraulic conductivity values were between 700 and 1000m/day. The wetland system proved to be efficient for the secondary treatment of leachate from mature landfills, obtaining removal efficiencies significantly higher in HSSFCW-C. h. Los humedales construidos en los últimos años han sido ampliamente usados en la depuración de una gran variedad de aguas residuales, por ser una alternativa que ofrece múltiples ventajas, en comparación con otros sistemas de tratamiento. Este estudio evaluó la eficiencia de seis sistemas de humedales, construidos de flujo subsuperficial horizontal (HCFSSH), a escala piloto, para la remoción de materia orgánica (DQO), nutrientes (N-NO3-, P-PO43-) y plomo (Pb+2), además de la incidencia del tiempo de operación sobre la conductividad hidráulica (Ks) para tratar lixiviados del Relleno Sanitario “El Ojito”, del municipio de Popayán, Cauca. Tres humedales fueron plantados con Heliconia psittacorum (HCFSSH-H. p) y tres con Cyperus haspan (HCFSSH-C. h); el medio de soporte utilizado fue grava, operados con un caudal de 0.012m3/día y un tiempo de retención hidráulico de 4 días; las unidades recibieron efluente de una laguna de oxidación. Los resultados mostraron remociones medias de: DQO (51,67 y 64,00%), N-NO3- (45,33 y 48,17%), P-PO43- (53,67 y 62,67%) y Pb+2 (5,74 y 14,75%) para los HCFSSH-H. p y HCFSSH-C. h, respectivamente y valores de conductividad hidráulica, entre 700 y 1000m/día. El sistema de humedales mostró ser eficiente para el tratamiento secundario de lixiviado de rellenos sanitarios maduros, obteniendo eficiencias de remoción, significativamente mayores, en los HCFSSH-C. h.