Boosayarat Tomapatanaget
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Boosayarat Tomapatanaget has a total of 52 co-authors. Here are the top co-authors by number of shared publications:
Thawatchai Tuntulani
Supramolecular Chemistry Research Unit, Department of, Chemistry, Faculty of Science, Chulalongkorn University, Phayathai Road, Patumwan, Bangkok 10330, Thailand
8 shared publications- Vithaya Ruangpornvisuti
Supramolecular Chemistry Research Unit, Department of Chemistry, Faculty of Science, Chulalongkorn University, Bangkok 10330, Thailand
4 shared publications Gamolwan Tumcharern
National Nanotechnology Center, National Science and Technology Development Agency, Pathumthani 12120, Thailand
3 shared publicationsJaturong Kongwutthivech
Department of Chemistry, Faculty of Science, Chulalongkorn University, Bangkok, Thailand
3 shared publicationsYanisa Sanguansap
Supramolecular Chemistry Research Unit, Department of Chemistry, Faculty of Science, Chulalongkorn University, Bangkok 10330, Thailand
3 shared publicationsAnusak Chaicham
Chulalongkorn Univ, Dept Chem, Fac Sci, Bangkok 10330, Thailand
2 shared publications
Latest Publications
- 1 January 2026
- Published by Royal Society of Chemistry (RSC) in Materials Chemistry Frontiers
Pillar[5]arene-guided supramolecular pseudorotaxane nanoparticles for the multi-responsive, highly selective sensing of l -glutathione and gold( iii ) ions
The supramolecular pseudorotaxane polymeric nanoparticles (HNP5A⊂BS-SPNs) developed through self-assembly driven by host–guest complexation giving rigid polymeric nanoparticles and pronouncing a dual-responsive fluorescence sensing platform for GSH and Au 3+ which generates AuNPs-NP5A⊂BS formation.
- 1 January 2026
- Published by Royal Society of Chemistry (RSC) in Materials Chemistry Frontiers
Pillar[5]arene-guided supramolecular pseudorotaxane nanoparticles for the multi-responsive, highly selective sensing of l -glutathione and gold( iii ) ions
The supramolecular pseudorotaxane polymeric nanoparticles (HNP5A⊂BS-SPNs) developed through self-assembly driven by host–guest complexation giving rigid polymeric nanoparticles and pronouncing a dual-responsive fluorescence sensing platform for GSH and Au 3+ which generates AuNPs-NP5A⊂BS formation.
- 6 June 2024
- Published by Springer Nature in Microchimica Acta
- Vol. 191 (7) , 1-11
Fluorescent-based micellar incorporated hydrogel materials for selective determination of long-chain aldehydes
A highly sensitive micelle-induced sensory has been developed for detection of long-chain aldehydes as potential biomarkers of respiratory cancers. The micelle-like sensor was fabricated through the partial self-assembly of CTAB and S2 surfactants, containing a fluorescent hydrazine-functionalized dye (Naph-NH2). In principle, long-chain aldehydes with amphiphilic character act as the induced-fit surfactants to form well-entrapped micellar particles, as well as react with Naph-NH2 to form hydrazone derivatives resulting in fluorescent enhancement. The limit of detection (LOD) of micellar Naph-NH2/CTAB/S2 platform was calculated to be \(\sim\) 64.09–80.98 µM for detection of long-chain aldehydes, which showed fluorescent imaging in lung cancer cells (A549). This micellar sensory probe demonstrated practical applicability for long-chain aldehyde sensing in human blood samples with an accepted percent recovery of ~ 94.02–102.4%. Beyond Naph-NH2/CTAB/S2 sensor, the milcellar hybrid sensor was successfully developed by incorporating a micelle-like platform with supramolecular gel regarding to carboxylate-based gelators (Gel1), which showed a tenfold improvement in sensitivity. Expectedly, the determination of long-chain aldehydes through these sensing platforms holds significant promise for point-of-care cancer diagnosis and therapy. Graphical Abstract- 6 June 2024
- Published by Springer Nature in Microchimica Acta
- Vol. 191 (7) , 1-11
Fluorescent-based micellar incorporated hydrogel materials for selective determination of long-chain aldehydes
A highly sensitive micelle-induced sensory has been developed for detection of long-chain aldehydes as potential biomarkers of respiratory cancers. The micelle-like sensor was fabricated through the partial self-assembly of CTAB and S2 surfactants, containing a fluorescent hydrazine-functionalized dye (Naph-NH2). In principle, long-chain aldehydes with amphiphilic character act as the induced-fit surfactants to form well-entrapped micellar particles, as well as react with Naph-NH2 to form hydrazone derivatives resulting in fluorescent enhancement. The limit of detection (LOD) of micellar Naph-NH2/CTAB/S2 platform was calculated to be \(\sim\) 64.09–80.98 µM for detection of long-chain aldehydes, which showed fluorescent imaging in lung cancer cells (A549). This micellar sensory probe demonstrated practical applicability for long-chain aldehyde sensing in human blood samples with an accepted percent recovery of ~ 94.02–102.4%. Beyond Naph-NH2/CTAB/S2 sensor, the milcellar hybrid sensor was successfully developed by incorporating a micelle-like platform with supramolecular gel regarding to carboxylate-based gelators (Gel1), which showed a tenfold improvement in sensitivity. Expectedly, the determination of long-chain aldehydes through these sensing platforms holds significant promise for point-of-care cancer diagnosis and therapy. Graphical Abstract- 11 July 2023
- Published by Royal Society of Chemistry (RSC) in Chemical Communications
- Vol. 59 (60) , 9207-9210
Supramolecular self-assembled polymeric nanospheres based on hydrazino naphthalimide functionalised pillar[5]arene for long chain aldehyde detection
A novel fluorescent sensor composed of bis-hydrazino naphthalimide decorated with a pillar[5]arene motif demonstrated highly selective fluorescent sensing of nonanal and octanalviaself-assembled supramolecular polymeric nanoparticles.
- 11 July 2023
- Published by Royal Society of Chemistry (RSC) in Chemical Communications
- Vol. 59 (60) , 9207-9210
Supramolecular self-assembled polymeric nanospheres based on hydrazino naphthalimide functionalised pillar[5]arene for long chain aldehyde detection
A novel fluorescent sensor composed of bis-hydrazino naphthalimide decorated with a pillar[5]arene motif demonstrated highly selective fluorescent sensing of nonanal and octanalviaself-assembled supramolecular polymeric nanoparticles.
- 2 June 2023
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 148 (13) , 2956-2964
A fluorescence-based sweat test sensor in a proof-of-concept clinical study for COVID-19 screening diagnosis
During the corona virus disease 2019 (COVID-19) pandemic period, rapid screening of covid-19 patients has been of great interest by developing a fluorescent sensor for complexation with nonanal, which is a marker for Covid-19 detection in sweat. Solid phase micro-extraction gas chromatography-mass spectrometry (SPME GC-MS) was initially used to quantify nonanal in armpit sweat samples based on an external calibration curve. A sample containing a nonanal content above the threshold of 1.04 μL is expected to be COVID-19 positive with a sensitivity and specificity of 87% and 89%, respectively, validated by comparison with RT-PCR results. For more practical applications, helicene dye-encapsulated ethyl cellulose, namely EC@dyeNH, was applied to screen 140 sweat samples collected from the foreheads of volunteers. The mixed sensor and sweat solution droplets were then visualized and imaged under blacklight. The COVID-19 positive droplets exhibited yellow fluorescence emission, the brightness of which could be measured by using ImageJ in the grey scale. With the optimum color intensity of >73 for positive results, the screening performance was observed with a sensitivity and specificity of 96% and 93%, respectively. The overall test time of this method is approximately less than 15 min. This alternative method offers a promising practical screening approach for the diagnosis of COVID-19 in sweat.
- 2 June 2023
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 148 (13) , 2956-2964
A fluorescence-based sweat test sensor in a proof-of-concept clinical study for COVID-19 screening diagnosis
During the corona virus disease 2019 (COVID-19) pandemic period, rapid screening of covid-19 patients has been of great interest by developing a fluorescent sensor for complexation with nonanal, which is a marker for Covid-19 detection in sweat. Solid phase micro-extraction gas chromatography-mass spectrometry (SPME GC-MS) was initially used to quantify nonanal in armpit sweat samples based on an external calibration curve. A sample containing a nonanal content above the threshold of 1.04 μL is expected to be COVID-19 positive with a sensitivity and specificity of 87% and 89%, respectively, validated by comparison with RT-PCR results. For more practical applications, helicene dye-encapsulated ethyl cellulose, namely EC@dyeNH, was applied to screen 140 sweat samples collected from the foreheads of volunteers. The mixed sensor and sweat solution droplets were then visualized and imaged under blacklight. The COVID-19 positive droplets exhibited yellow fluorescence emission, the brightness of which could be measured by using ImageJ in the grey scale. With the optimum color intensity of >73 for positive results, the screening performance was observed with a sensitivity and specificity of 96% and 93%, respectively. The overall test time of this method is approximately less than 15 min. This alternative method offers a promising practical screening approach for the diagnosis of COVID-19 in sweat.
- 27 October 2022
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 14 (44) , 49495-49507
Helicene-Hydrazide Encapsulated Ethyl Cellulose as a Potential Fluorescence Sensor for Highly Specific Detection of Nonanal in Aqueous Solutions and a Proof-of-Concept Clinical Study in Lung Fluid
Over the past years, lung cancer has been one of the vital cancer-related mortalities worldwide and has inevitably exhibited the highest death rate with the subsequent need for facile and convenient diagnosis approaches to identify the severity of cancer. Previous research has reported long-chain aldehyde compounds such as hexanal, heptanal, octanal, and nonanal as potential biomarkers of lung cancer. Herein, the helicene dye-encapsulated ethyl cellulose (EC@dye-NH) nanosensors have been applied for the potentially sensitive and specific detection of long-chain aldehydes in aqueous media. The sensors contain the intrinsic hydrazide group of dye-NH, which is capable of reacting an aldehyde group via imine formation and the EC backbone. This offers the synergistic forces of hydrophobic interactions with alkyl long-chain aldehydes, which could induce self-assembly encapsulation of EC@dye-NH nanosensors and strong fluorescence responses. The addition of long-chain aldehyde would induce the complete micellar-like nanoparticle formation within 15 min in acetate buffer pH 5.0. The limit of detection (LOD) values of EC@dye-NH nanosensors toward heptanal, octanal, and nonanal were 40, 100, and 10 μM, respectively, without interference from the lung fluid matrices and short-chain aldehydes. For practical applicability, this sensing platform was developed for quantification of the long-chain aldehydes in lung fluid samples with 98-101% recoveries. This EC@dye-NH nanosensor was applied to quantify nonanal contents in lung fluid samples. The results of this method based on EC@dye-NH nanosensors were then validated using standard gas chromatography-mass spectrometry (GC-MS), which gave results consistent with the proposed method. With intracellular imaging application, the EC@dye-NH nanosensors demonstrated excellent intracellular uptake and strong green fluorescence emission upon introducing the nonanal into the lung cancer cells (A549). Thus, the developed nanosensing approach served as the potential fluorescent probes in medical and biological fields, especially for lung cancer disease diagnosis based on highly selective and sensitive detection of long-chain aldehydes.
- 27 October 2022
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 14 (44) , 49495-49507
Helicene-Hydrazide Encapsulated Ethyl Cellulose as a Potential Fluorescence Sensor for Highly Specific Detection of Nonanal in Aqueous Solutions and a Proof-of-Concept Clinical Study in Lung Fluid
Over the past years, lung cancer has been one of the vital cancer-related mortalities worldwide and has inevitably exhibited the highest death rate with the subsequent need for facile and convenient diagnosis approaches to identify the severity of cancer. Previous research has reported long-chain aldehyde compounds such as hexanal, heptanal, octanal, and nonanal as potential biomarkers of lung cancer. Herein, the helicene dye-encapsulated ethyl cellulose (EC@dye-NH) nanosensors have been applied for the potentially sensitive and specific detection of long-chain aldehydes in aqueous media. The sensors contain the intrinsic hydrazide group of dye-NH, which is capable of reacting an aldehyde group via imine formation and the EC backbone. This offers the synergistic forces of hydrophobic interactions with alkyl long-chain aldehydes, which could induce self-assembly encapsulation of EC@dye-NH nanosensors and strong fluorescence responses. The addition of long-chain aldehyde would induce the complete micellar-like nanoparticle formation within 15 min in acetate buffer pH 5.0. The limit of detection (LOD) values of EC@dye-NH nanosensors toward heptanal, octanal, and nonanal were 40, 100, and 10 μM, respectively, without interference from the lung fluid matrices and short-chain aldehydes. For practical applicability, this sensing platform was developed for quantification of the long-chain aldehydes in lung fluid samples with 98-101% recoveries. This EC@dye-NH nanosensor was applied to quantify nonanal contents in lung fluid samples. The results of this method based on EC@dye-NH nanosensors were then validated using standard gas chromatography-mass spectrometry (GC-MS), which gave results consistent with the proposed method. With intracellular imaging application, the EC@dye-NH nanosensors demonstrated excellent intracellular uptake and strong green fluorescence emission upon introducing the nonanal into the lung cancer cells (A549). Thus, the developed nanosensing approach served as the potential fluorescent probes in medical and biological fields, especially for lung cancer disease diagnosis based on highly selective and sensitive detection of long-chain aldehydes.
- 9 July 2021
- Published by Royal Society of Chemistry (RSC) in Materials Chemistry Frontiers
- Vol. 5 (18) , 6850-6859
Enhancement of sensitivity for dichlorvos detection by a low-weight gelator based on bolaamphiphile amino acid derivatives decorated with a hybrid graphene quantum dot/enzyme/hydrogel
Developing the sensitivity of an optical biosensor motivates the exploration of an amplification strategy for the incorporation of a biosensor system in a supramolecular hydrogel. We developed novel fluorescent hybrid materials comprising graphene quantum dots and enzymes supported by L-phenylalanine derived bis(urea) supramolecular hydrogels (GQDs/Enz/Gels) for detection of organophosphates. The addition of acetylcholinesterase (AChE) and choline oxidase (ChOx) during the formation of self-assembled GQDs/Gel materials resulted in enzyme-functionalized gel networks. Significant turn-off fluorescence of the encapsulated GQDs in the hydrogels was due to hydrogen peroxide generated from the active enzymatic reaction. The addition of insecticide dichlorvos to the GQDs/Enz/Gels resulted in the recovery of fluorescence in proportion to the concentration of dichlorvos, with a detection limit of 2.61 × 10−8 M which outperforms those in solution by 100-fold improvement and a wider linear range of 1.25 × 10−8–1.25 × 10−4 M compared to those of the biosensor in solution. These hybrid hydrogels show promising sensitivity to the detection of oxy-form organophosphate pesticides and expectedly offer scope for the development of rapid and environmentally friendly techniques.
- 9 July 2021
- Published by Royal Society of Chemistry (RSC) in Materials Chemistry Frontiers
- Vol. 5 (18) , 6850-6859
Enhancement of sensitivity for dichlorvos detection by a low-weight gelator based on bolaamphiphile amino acid derivatives decorated with a hybrid graphene quantum dot/enzyme/hydrogel
Developing the sensitivity of an optical biosensor motivates the exploration of an amplification strategy for the incorporation of a biosensor system in a supramolecular hydrogel. We developed novel fluorescent hybrid materials comprising graphene quantum dots and enzymes supported by L-phenylalanine derived bis(urea) supramolecular hydrogels (GQDs/Enz/Gels) for detection of organophosphates. The addition of acetylcholinesterase (AChE) and choline oxidase (ChOx) during the formation of self-assembled GQDs/Gel materials resulted in enzyme-functionalized gel networks. Significant turn-off fluorescence of the encapsulated GQDs in the hydrogels was due to hydrogen peroxide generated from the active enzymatic reaction. The addition of insecticide dichlorvos to the GQDs/Enz/Gels resulted in the recovery of fluorescence in proportion to the concentration of dichlorvos, with a detection limit of 2.61 × 10−8 M which outperforms those in solution by 100-fold improvement and a wider linear range of 1.25 × 10−8–1.25 × 10−4 M compared to those of the biosensor in solution. These hybrid hydrogels show promising sensitivity to the detection of oxy-form organophosphate pesticides and expectedly offer scope for the development of rapid and environmentally friendly techniques.
- 27 January 2020
- Published by Springer Nature in Journal of Fluorescence
- Vol. 30 (2) , 259-267
Dual Naked-Eye Optical Sensor Based on Imidazolium Cation and Napthalamide for Specific Detection of Fluoride
A novel naked eye fluorescence sensor (ANI) based on naphthalimide and imidazolium moieties for fluoride detection has been designed and synthesized by multiple step synthesis. The fluorescence response of ANI sensor was significantly quenched in the presence of fluoride ion upon the interaction between an acidic amide proton and acidic C2 proton (-C(2)H-) of imidazolium compound. The binding behavior of ANI and F− ion was extensively explored by using NMR titration. Comparison of binding ability of ANI and AN sensors addressed the dominant electrostatic and hydrogen bonding interaction with F− ion. Consequently, ANI sensor highlights a strong binding with F− ions with a high selectivity over AN. Interestingly, ANI demonstrated a naked-eye response with colorimetric and fluorometric assay.
- 27 January 2020
- Published by Springer Nature in Journal of Fluorescence
- Vol. 30 (2) , 259-267
Dual Naked-Eye Optical Sensor Based on Imidazolium Cation and Napthalamide for Specific Detection of Fluoride
A novel naked eye fluorescence sensor (ANI) based on naphthalimide and imidazolium moieties for fluoride detection has been designed and synthesized by multiple step synthesis. The fluorescence response of ANI sensor was significantly quenched in the presence of fluoride ion upon the interaction between an acidic amide proton and acidic C2 proton (-C(2)H-) of imidazolium compound. The binding behavior of ANI and F− ion was extensively explored by using NMR titration. Comparison of binding ability of ANI and AN sensors addressed the dominant electrostatic and hydrogen bonding interaction with F− ion. Consequently, ANI sensor highlights a strong binding with F− ions with a high selectivity over AN. Interestingly, ANI demonstrated a naked-eye response with colorimetric and fluorometric assay.