Jan Grosek
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Jan Grosek has a total of 1000 co-authors. Here are the top co-authors by number of shared publications:
- Blaž Trotovšek
Department of Abdominal Surgery, University Medical Center Ljubljana, 1000 Ljubljana, Slovenia
5 shared publications Aleš Tomažič
Univ Med Ctr Ljubljana, Dept Abdominal Surg, Zaloska 7, Ljubljana 1000, Slovenia
4 shared publications- Aleš Tomažič
Department of Abdominal Surgery, University Medical Centre Ljubljana, Zaloška Cesta 7, 1000 Ljubljana, Slovenia
4 shared publications - Miha Petrič
Department of Abdominal Surgery, University Medical Centre Ljubljana, Zaloška 7, 1000 Ljubljana, Slovenia
3 shared publications - Andraž Hubad
Department of Abdominal Surgery, University Medical Centre Ljubljana, Zaloška Cesta 7, 1000 Ljubljana, Slovenia
2 shared publications - Boštjan Plešnik
Department of Abdominal Surgery, University Medical Center Ljubljana, Zaloska 7, 1000 Ljubljana, Slovenia
2 shared publications
Latest Publications
- Open Access
- 1 September 2026
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 15 (17) , 6778
Early Adoption of Technically Complex Robotic Ventral Hernia Repair in a Low-Volume Center: A Retrospective Comparative Analysis with Consecutive Open Cases
Background/Objectives: Robotic-assisted abdominal wall reconstruction is increasingly used for ventral hernias; however, implementation in low-volume settings and early adoption of technically complex cases remain controversial. This study aimed to evaluate perioperative outcomes of robotic ventral hernia repair with early inclusion of technically complex cases and to compare these results with open surgery. Methods: Prospectively collected data were retrospectively analyzed for consecutive technically complex robotic ventral hernia repairs performed between September 2021 and December 2025. A cohort of consecutive open Rives–Stoppa repairs was included for comparison (n = 21 per group). Outcomes included operative time, length of hospital stay (LOS), and perioperative complications. Results: Operative time was significantly longer in the robotic group (median 310 vs. 118 min, p < 0.001). The median LOS was significantly shorter following robotic repair (3 vs. 5 days, p = 0.0018). Postoperative complications occurred in 10% of robotic cases and 24% of open cases (p = 0.41). Major complications and reoperation rates were low and comparable between groups. Technically complex robotic cases, including procedures requiring component separation, were introduced early and were associated with acceptable short-term outcomes. Conclusions: Technically complex robotic hernia repair was associated with significantly shorter hospital stay compared with open surgery, despite longer operative times and higher procedural complexity. Complication rates were comparable between groups. Early inclusion of technically complex cases was not associated with a statistically significant increase in short-term complications.
- 1 September 2026
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 15 (17) , 6778
Open AccessEarly Adoption of Technically Complex Robotic Ventral Hernia Repair in a Low-Volume Center: A Retrospective Comparative Analysis with Consecutive Open Cases
Background/Objectives: Robotic-assisted abdominal wall reconstruction is increasingly used for ventral hernias; however, implementation in low-volume settings and early adoption of technically complex cases remain controversial. This study aimed to evaluate perioperative outcomes of robotic ventral hernia repair with early inclusion of technically complex cases and to compare these results with open surgery. Methods: Prospectively collected data were retrospectively analyzed for consecutive technically complex robotic ventral hernia repairs performed between September 2021 and December 2025. A cohort of consecutive open Rives–Stoppa repairs was included for comparison (n = 21 per group). Outcomes included operative time, length of hospital stay (LOS), and perioperative complications. Results: Operative time was significantly longer in the robotic group (median 310 vs. 118 min, p < 0.001). The median LOS was significantly shorter following robotic repair (3 vs. 5 days, p = 0.0018). Postoperative complications occurred in 10% of robotic cases and 24% of open cases (p = 0.41). Major complications and reoperation rates were low and comparable between groups. Technically complex robotic cases, including procedures requiring component separation, were introduced early and were associated with acceptable short-term outcomes. Conclusions: Technically complex robotic hernia repair was associated with significantly shorter hospital stay compared with open surgery, despite longer operative times and higher procedural complexity. Complication rates were comparable between groups. Early inclusion of technically complex cases was not associated with a statistically significant increase in short-term complications.
- Open Access
- 3 August 2026
- Published by MDPI AG in Preprints.org
Early Adoption of Complex Robotic Ventral Hernia Repair in a Low-Volume Center: A Retrospective Comparative Analysis with Consecutive Open Cases
Background/Objectives: Robotic-assisted abdominal wall reconstruction is increasingly used for complex ventral hernias; however, implementation in low-volume settings and early adoption of complex cases remain controversial. This study aimed to evaluate perioperative outcomes of robotic ventral hernia repair with early inclusion of complex cases and to compare these results with open surgery. Methods: Prospectively collected data were retrospectively analyzed for consecutive complex robotic ventral hernia repairs performed between September 2021 and December 2025. A cohort of consecutive open Rives–Stoppa repairs was included for comparison (n = 21 per group). Outcomes included operative time, length of hospital stay (LOS), and perioperative complications. Results: Operative time was significantly longer in the robotic group (median 310 vs. 118 minutes, p < 0.001). The median LOS was significantly shorter following robotic repair (3 vs. 5 days, p = 0.0018). Postoperative complications occurred in 10% of robotic cases and 24% of open cases (p = 0.41). Major complications and reoperation rates were low and comparable between groups. Complex robotic cases, including procedures requiring component separation, were introduced early without evidence of worse short-term outcomes. Conclusions: Robotic ventral hernia repair was associated with significantly shorter hospital stay compared with open surgery, despite longer operative times and higher procedural complexity. Complication rates were comparable between groups. Early inclusion of technically complex cases did not compromise short-term outcomes.
- 3 August 2026
- Published by MDPI AG in Preprints.org
Open AccessEarly Adoption of Complex Robotic Ventral Hernia Repair in a Low-Volume Center: A Retrospective Comparative Analysis with Consecutive Open Cases
Background/Objectives: Robotic-assisted abdominal wall reconstruction is increasingly used for complex ventral hernias; however, implementation in low-volume settings and early adoption of complex cases remain controversial. This study aimed to evaluate perioperative outcomes of robotic ventral hernia repair with early inclusion of complex cases and to compare these results with open surgery. Methods: Prospectively collected data were retrospectively analyzed for consecutive complex robotic ventral hernia repairs performed between September 2021 and December 2025. A cohort of consecutive open Rives–Stoppa repairs was included for comparison (n = 21 per group). Outcomes included operative time, length of hospital stay (LOS), and perioperative complications. Results: Operative time was significantly longer in the robotic group (median 310 vs. 118 minutes, p < 0.001). The median LOS was significantly shorter following robotic repair (3 vs. 5 days, p = 0.0018). Postoperative complications occurred in 10% of robotic cases and 24% of open cases (p = 0.41). Major complications and reoperation rates were low and comparable between groups. Complex robotic cases, including procedures requiring component separation, were introduced early without evidence of worse short-term outcomes. Conclusions: Robotic ventral hernia repair was associated with significantly shorter hospital stay compared with open surgery, despite longer operative times and higher procedural complexity. Complication rates were comparable between groups. Early inclusion of technically complex cases did not compromise short-term outcomes.
- Open Access
- 20 July 2026
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 15 (14) , 5669
Safe Implementation of Robotic Colorectal Surgery: Balancing Surgical Training and Patient Safety with the Dual-Console System
Background: Robotic platforms expand minimally invasive options in colorectal surgery but raise concerns about training and patient safety. Dual-console systems may enable real-time coaching while preserving outcomes. Methods: We implemented a structured framework for safe implementation of robotic colorectal surgery that balances trainee autonomy with patient safety using a dual-console model. Early cases emphasized low-complexity pathology with escalation by predefined benchmarks. We prospectively gathered data and evaluated early program outcomes with primary endpoints including intraoperative adverse events, conversion to open surgery, 30-day morbidity, anastomotic integrity, and oncologic quality metrics. Secondary endpoints included operative time. Results: We included the analysis of 17 patients operated by one surgeon under supervision and compared the results to other senior colorectal surgeons. Out of the 17 patients, there were no conversions or anastomotic leaks. Overall complications were comparable to baseline robotic cases. Resection margins and lymph node yields met oncologic standards. Operative times were longer during early adoption but approached baseline with progression. Operative times were significantly reduced after eight cases and approached the times of senior surgeons after 13 cases. Conclusions: A dual-console strategy enables safe, scalable training in robotic colorectal surgery without compromising short-term patient outcomes or oncologic quality. Key elements include rigorous case selection, proficiency-based progression, real-time coaching, standardized protocols, and continuous data surveillance. This framework can guide institutions seeking to expand robotic colorectal programs while safeguarding patients and accelerating the learning curve.
- 20 July 2026
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 15 (14) , 5669
Open AccessSafe Implementation of Robotic Colorectal Surgery: Balancing Surgical Training and Patient Safety with the Dual-Console System
Background: Robotic platforms expand minimally invasive options in colorectal surgery but raise concerns about training and patient safety. Dual-console systems may enable real-time coaching while preserving outcomes. Methods: We implemented a structured framework for safe implementation of robotic colorectal surgery that balances trainee autonomy with patient safety using a dual-console model. Early cases emphasized low-complexity pathology with escalation by predefined benchmarks. We prospectively gathered data and evaluated early program outcomes with primary endpoints including intraoperative adverse events, conversion to open surgery, 30-day morbidity, anastomotic integrity, and oncologic quality metrics. Secondary endpoints included operative time. Results: We included the analysis of 17 patients operated by one surgeon under supervision and compared the results to other senior colorectal surgeons. Out of the 17 patients, there were no conversions or anastomotic leaks. Overall complications were comparable to baseline robotic cases. Resection margins and lymph node yields met oncologic standards. Operative times were longer during early adoption but approached baseline with progression. Operative times were significantly reduced after eight cases and approached the times of senior surgeons after 13 cases. Conclusions: A dual-console strategy enables safe, scalable training in robotic colorectal surgery without compromising short-term patient outcomes or oncologic quality. Key elements include rigorous case selection, proficiency-based progression, real-time coaching, standardized protocols, and continuous data surveillance. This framework can guide institutions seeking to expand robotic colorectal programs while safeguarding patients and accelerating the learning curve.
- Open Access
- 22 March 2026
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 15 (6) , 2424
Safety of Simultaneous Robot-Assisted Resection of Colorectal Malignancy and Synchronous Liver Metastases
Introduction: Simultaneous resection of primary colorectal malignancies and liver metastases resulted in outcomes comparable to those achieved through a two-stage procedure, while offering the advantage of a single surgical intervention. The role of the robotic approach remains underexplored because of the lack of comprehensive evidence. The objective of our study was to examine the safety of the robotic surgical platform, assess its short-term outcomes, and compare them with those of open procedures. Methods and Material: We retrospectively analyzed data from an initial small series of eight consecutive patients treated at the UMC Ljubljana between March 2023 and December 2025. These patients underwent robot-assisted simultaneous resection of colorectal malignancies and liver metastases. Their outcomes were compared with those of an open cohort of eight patients. Results: The median operative time was 334 min (range, 193–415 min). No conversions or transfusions were required. Three patients experienced severe complications, accounting for 37.5% of the cohort. The median duration of hospitalization was 9.5 days. The median number of lymph nodes retrieved was 22. Complete (R0) resection of the primary tumor was achieved in all cases (100%), whereas resection of the liver was achieved in 87.5% of the cases. Importantly, there were no instances of re-hospitalization within 30 days or mortality within 90 days. Conclusions: Although the rate of severe complications is relatively high, the robotic surgical platform allows for the safe simultaneous resection of colorectal malignancies and liver metastases, achieving short-term outcomes comparable to those of open surgery.
- 22 March 2026
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 15 (6) , 2424
Open AccessSafety of Simultaneous Robot-Assisted Resection of Colorectal Malignancy and Synchronous Liver Metastases
Introduction: Simultaneous resection of primary colorectal malignancies and liver metastases resulted in outcomes comparable to those achieved through a two-stage procedure, while offering the advantage of a single surgical intervention. The role of the robotic approach remains underexplored because of the lack of comprehensive evidence. The objective of our study was to examine the safety of the robotic surgical platform, assess its short-term outcomes, and compare them with those of open procedures. Methods and Material: We retrospectively analyzed data from an initial small series of eight consecutive patients treated at the UMC Ljubljana between March 2023 and December 2025. These patients underwent robot-assisted simultaneous resection of colorectal malignancies and liver metastases. Their outcomes were compared with those of an open cohort of eight patients. Results: The median operative time was 334 min (range, 193–415 min). No conversions or transfusions were required. Three patients experienced severe complications, accounting for 37.5% of the cohort. The median duration of hospitalization was 9.5 days. The median number of lymph nodes retrieved was 22. Complete (R0) resection of the primary tumor was achieved in all cases (100%), whereas resection of the liver was achieved in 87.5% of the cases. Importantly, there were no instances of re-hospitalization within 30 days or mortality within 90 days. Conclusions: Although the rate of severe complications is relatively high, the robotic surgical platform allows for the safe simultaneous resection of colorectal malignancies and liver metastases, achieving short-term outcomes comparable to those of open surgery.
- Open Access
Establishing a Robot-Assisted Liver Surgery Program: Early Experience from University Medical Center Ljubljana
Background and Objectives: Robot-assisted procedures represent a significant advancement in minimally invasive liver resection techniques. Nonetheless, the introduction of a novel surgical technique in a new environment necessitates meticulous planning and a gradual, stepwise approach. This study describes the adoption of a robotic surgical platform for liver resection at a high-volume tertiary care center. Materials and Methods: We retrospectively analyzed data that had been prospectively collected from fifty robot-assisted liver resections. Descriptive statistics, including frequencies, percentages, means/medians, and standard deviations, were employed for description and summary. Results: The median operative duration was 166 min (range: 85–400 min), with an average intraoperative blood loss of 200 mL (range: 50–1000 milliliters). Intraoperative or postoperative blood transfusion was required in 8% of patients. Conversion to open resection was necessary in one patient (2%). The mean duration of hospitalization was 5 days (range: 3–20 days), with a 30-day readmission rate of 6% and no mortality within 90 days. Postoperative complications classified as Clavien-Dindo grade 3 or higher were observed in five patients (10%). The mean tumor size varied according to pathology: 58.5 mm (range: 30–120 mm) in the hepatocellular carcinoma group; 27.4 mm (range: 10–32 mm) in the secondary malignancy group; and 42.6 mm (range: 24–60 mm) in the intrahepatic cholangiocarcinoma group. The median number of lymph nodes harvested during lymphadenectomy (IHHCA/GBCA) was 5.4, ranging from 1 to 11. The R0 resection rate for malignant tumors was 88.2% (of 30/34). Conclusions: This study validates the safe integration of robot-assisted surgery into liver disease treatment, supported by our initial experience. Despite its technical advantages, robotic-assisted liver surgery remains complex and demanding. Structured robotic training within established programs, meticulous patient selection, and a stepwise implementation approach are critical during the early phases to optimize the outcomes.
Open AccessEstablishing a Robot-Assisted Liver Surgery Program: Early Experience from University Medical Center Ljubljana
Background and Objectives: Robot-assisted procedures represent a significant advancement in minimally invasive liver resection techniques. Nonetheless, the introduction of a novel surgical technique in a new environment necessitates meticulous planning and a gradual, stepwise approach. This study describes the adoption of a robotic surgical platform for liver resection at a high-volume tertiary care center. Materials and Methods: We retrospectively analyzed data that had been prospectively collected from fifty robot-assisted liver resections. Descriptive statistics, including frequencies, percentages, means/medians, and standard deviations, were employed for description and summary. Results: The median operative duration was 166 min (range: 85–400 min), with an average intraoperative blood loss of 200 mL (range: 50–1000 milliliters). Intraoperative or postoperative blood transfusion was required in 8% of patients. Conversion to open resection was necessary in one patient (2%). The mean duration of hospitalization was 5 days (range: 3–20 days), with a 30-day readmission rate of 6% and no mortality within 90 days. Postoperative complications classified as Clavien-Dindo grade 3 or higher were observed in five patients (10%). The mean tumor size varied according to pathology: 58.5 mm (range: 30–120 mm) in the hepatocellular carcinoma group; 27.4 mm (range: 10–32 mm) in the secondary malignancy group; and 42.6 mm (range: 24–60 mm) in the intrahepatic cholangiocarcinoma group. The median number of lymph nodes harvested during lymphadenectomy (IHHCA/GBCA) was 5.4, ranging from 1 to 11. The R0 resection rate for malignant tumors was 88.2% (of 30/34). Conclusions: This study validates the safe integration of robot-assisted surgery into liver disease treatment, supported by our initial experience. Despite its technical advantages, robotic-assisted liver surgery remains complex and demanding. Structured robotic training within established programs, meticulous patient selection, and a stepwise implementation approach are critical during the early phases to optimize the outcomes.
- Open Access
- 9 June 2023
- Published by MDPI AG in Surgical Techniques Development
- Vol. 12 (2) , 99-106
Minimally Invasive Peritoneal Dialysis Catheter Insertion with Intraoperative Ultrasound-Doppler Measurement of Rectus Muscle Width and Inferior Epigastric Artery Localization
Laparoscopic peritoneal dialysis catheter insertion is an established method for peritoneal dialysis catheter placement. One critical aspect of this procedure is rectus sheath tunneling. Proper peritoneal dialysis catheter incorporation within the abdominal wall is important for reducing pericatheter leaks and for proper peritoneal dialysis functioning. Particularly, accurate positioning of the internal cuff within the rectus muscle sheath is crucial to prevent potential dialysate fluid leakage. In the present report, we describe the utilization of intraoperative ultrasound as a valuable tool for determining the ideal location of the internal cuff and assessing the course of the inferior epigastric artery during rectus sheath tunneling. This technique aims to optimize the position of the internal cuff and minimize complications such as vessel injury and pericatheter leaks. Furthermore, we demonstrate that post-catheter insertion, ultrasound imaging offers valuable insights into evaluating the appropriate placement of the internal cuff, external subcutaneous cuff, and potential bleeding within the abdominal wall.
- 9 June 2023
- Published by MDPI AG in Surgical Techniques Development
- Vol. 12 (2) , 99-106
Open AccessMinimally Invasive Peritoneal Dialysis Catheter Insertion with Intraoperative Ultrasound-Doppler Measurement of Rectus Muscle Width and Inferior Epigastric Artery Localization
Laparoscopic peritoneal dialysis catheter insertion is an established method for peritoneal dialysis catheter placement. One critical aspect of this procedure is rectus sheath tunneling. Proper peritoneal dialysis catheter incorporation within the abdominal wall is important for reducing pericatheter leaks and for proper peritoneal dialysis functioning. Particularly, accurate positioning of the internal cuff within the rectus muscle sheath is crucial to prevent potential dialysate fluid leakage. In the present report, we describe the utilization of intraoperative ultrasound as a valuable tool for determining the ideal location of the internal cuff and assessing the course of the inferior epigastric artery during rectus sheath tunneling. This technique aims to optimize the position of the internal cuff and minimize complications such as vessel injury and pericatheter leaks. Furthermore, we demonstrate that post-catheter insertion, ultrasound imaging offers valuable insights into evaluating the appropriate placement of the internal cuff, external subcutaneous cuff, and potential bleeding within the abdominal wall.
- Open Access
The Significance of Blood and Peritoneal Fluid Biochemical Markers in Identifying Early Anastomotic Leak following Colorectal Resection—Findings from a Single-Center Study
Background and Objectives: The aim of our study was to evaluate the value of leukocyte, C reactive protein (CRP), procalcitonin, lactate, and carcinoembryonic antigen (CEA) in blood and peritoneal fluid in early recognition of anastomotic leak (AL) after colorectal resections. Materials and Methods: Our pilot prospective cohort study was conducted at the abdominal surgery department at University Medical Center Ljubljana. A total of 43 patients who underwent open or laparoscopic colorectal resection because of benign or malignant etiology were enrolled. All of the patients had primary anastomosis without stoma formation. Results: Three patients in our patient group developed AL (7%). We found a statistically significant elevation of serum lactate levels in patients that developed AL compared to those who did not but noted no statistically relevant difference in the blood or peritoneal fluid levels of other biochemical markers. Conclusions: Elevated lactate levels may be considered a promising biomarker for the early diagnosis of AL, but more research on bigger patient groups is warranted.
Open AccessThe Significance of Blood and Peritoneal Fluid Biochemical Markers in Identifying Early Anastomotic Leak following Colorectal Resection—Findings from a Single-Center Study
Background and Objectives: The aim of our study was to evaluate the value of leukocyte, C reactive protein (CRP), procalcitonin, lactate, and carcinoembryonic antigen (CEA) in blood and peritoneal fluid in early recognition of anastomotic leak (AL) after colorectal resections. Materials and Methods: Our pilot prospective cohort study was conducted at the abdominal surgery department at University Medical Center Ljubljana. A total of 43 patients who underwent open or laparoscopic colorectal resection because of benign or malignant etiology were enrolled. All of the patients had primary anastomosis without stoma formation. Results: Three patients in our patient group developed AL (7%). We found a statistically significant elevation of serum lactate levels in patients that developed AL compared to those who did not but noted no statistically relevant difference in the blood or peritoneal fluid levels of other biochemical markers. Conclusions: Elevated lactate levels may be considered a promising biomarker for the early diagnosis of AL, but more research on bigger patient groups is warranted.
- Open Access
- 24 May 2022
- Published by Elsevier in The Lancet Global Health
- Vol. 10 (7) , e1003-e1011
Effects of hospital facilities on patient outcomes after cancer surgery: an international, prospective, observational study
- 24 May 2022
- Published by Elsevier in The Lancet Global Health
- Vol. 10 (7) , e1003-e1011
Open AccessEffects of hospital facilities on patient outcomes after cancer surgery: an international, prospective, observational study
- Open Access
- 1 April 2022
- Published by Medknow in Journal of Minimal Access Surgery
- Vol. 18 (2) , 311-313
Simultaneous robotic resection of pheochromocytoma and gastrointestinal stromal tumour in an adult neurofibromatosis type 1 patient
The risk of tumours, including pheochromocytoma and gastrointestinal stromal tumour is higher in patients with neurofibromatosis Type 1 (NF1). The co-occurrence of these two tumours is rare, and most patients are symptomatic. In this case report we describe the case of an asymptomatic 42-year-old female patient with left adrenal mass and concurrent lesion in the jejunum, just distal to the ligament of Treitz. Both tumours were successfully simultaneously removed by totally robotic transperitoneal technique using da Vinci Robotic Surgical System Xi.
- 1 April 2022
- Published by Medknow in Journal of Minimal Access Surgery
- Vol. 18 (2) , 311-313
Open AccessSimultaneous robotic resection of pheochromocytoma and gastrointestinal stromal tumour in an adult neurofibromatosis type 1 patient
The risk of tumours, including pheochromocytoma and gastrointestinal stromal tumour is higher in patients with neurofibromatosis Type 1 (NF1). The co-occurrence of these two tumours is rare, and most patients are symptomatic. In this case report we describe the case of an asymptomatic 42-year-old female patient with left adrenal mass and concurrent lesion in the jejunum, just distal to the ligament of Treitz. Both tumours were successfully simultaneously removed by totally robotic transperitoneal technique using da Vinci Robotic Surgical System Xi.
- Open Access
- 10 January 2022
- Published by MDPI AG in Biomedicines
- Vol. 10 (1) , 142
Differential Expression of Decorin in Metastasising Colorectal Carcinoma Is Regulated by miR-200c and Long Non-Coding RNAs
Decorin (DCN) is one of the matricellular proteins that participate in normal cells’ function as well as in cancerogenesis. While its expression in primary tumours is well known, there is limited data about its expression in metastases. Furthermore, the post-transcriptional regulation of DCN is still questionable, although it is well accepted that it is an important mechanism of developing metastatic cancer. The aim of our study was to analyse the expression of DCN and its potential regulatory ncRNAs in metastatic colorectal carcinoma (CRC). Nineteen patients with metastatic CRC were included. Using qPCR, we analysed the expression of DCN, miR-200c and five lncRNAs (LUCAT1, MALAT1, lncTCF7, XIST, and ZFAS1) in lymph node and liver metastases in comparison to the invasive front and central part of a primary tumour. Our results showed insignificant upregulation of DCN and significant upregulation for miR-200c, MALAT1, lncTCF7 and ZFAS1 in metastases compared to the primary tumour. miR-200c showed a positive correlation with DCN, and the aforementioned lncRNAs exhibited a significant positive correlation with miR-200c expression in metastatic CRC. Our results suggest that DCN as well as miR-200c, MALAT1, lncTCF7 and ZFAS1 contribute to the development of metastases in CRC and that regulation of DCN expression in CRC by ncRNAs is accomplished in an indirect manner.
- 10 January 2022
- Published by MDPI AG in Biomedicines
- Vol. 10 (1) , 142
Open AccessDifferential Expression of Decorin in Metastasising Colorectal Carcinoma Is Regulated by miR-200c and Long Non-Coding RNAs
Decorin (DCN) is one of the matricellular proteins that participate in normal cells’ function as well as in cancerogenesis. While its expression in primary tumours is well known, there is limited data about its expression in metastases. Furthermore, the post-transcriptional regulation of DCN is still questionable, although it is well accepted that it is an important mechanism of developing metastatic cancer. The aim of our study was to analyse the expression of DCN and its potential regulatory ncRNAs in metastatic colorectal carcinoma (CRC). Nineteen patients with metastatic CRC were included. Using qPCR, we analysed the expression of DCN, miR-200c and five lncRNAs (LUCAT1, MALAT1, lncTCF7, XIST, and ZFAS1) in lymph node and liver metastases in comparison to the invasive front and central part of a primary tumour. Our results showed insignificant upregulation of DCN and significant upregulation for miR-200c, MALAT1, lncTCF7 and ZFAS1 in metastases compared to the primary tumour. miR-200c showed a positive correlation with DCN, and the aforementioned lncRNAs exhibited a significant positive correlation with miR-200c expression in metastatic CRC. Our results suggest that DCN as well as miR-200c, MALAT1, lncTCF7 and ZFAS1 contribute to the development of metastases in CRC and that regulation of DCN expression in CRC by ncRNAs is accomplished in an indirect manner.