Tadzio Raoul Roche
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Tadzio Raoul Roche has a total of 81 co-authors. Here are the top co-authors by number of shared publications:
- David Werner Tscholl
Institute for Anesthesiology and Perioperative Medicine, University Hospital Zurich, Zurich, Switzerland
36 shared publications - Christoph Beat Nöthiger
Institute of Anesthesiology and Perioperative Medicine, University Hospital Zurich, 8091 Zurich, Switzerland
29 shared publications - Donat Rudolf Spahn
Faculty of Medicine, University of Zürich, 8091 Zürich, Switzerland
25 shared publications - Julia Braun
Department of Epidemiology, Epidemiology, Biostatistics and Prevention Institute, University of Zurich, Zurich, Switzerland
16 shared publications - Kai Zacharowski
Department of Anaesthesiology, Intensive Care and Pain Therapy, University Hospital Frankfurt, Goethe University Frankfurt, Frankfurt, Germany
15 shared publications - Samira Akbas
Institut für Anästhesiologie und perioperative Medizin, Universitätsspital Zürich, Zürich, Schweiz
14 shared publications
Latest Publications
- Open Access
- 1 April 2026
- Published by JMIR Publications Inc. in JMIR Human Factors
- Vol. 13 (1) , e82703
Anesthesia Providers’ Perspectives on the Redesigned Philips Acoustic Alarm System: Qualitative Pre- and Postimplementation Study
Background: Alarm fatigue caused by frequent or false alarms poses a persistent threat to patient safety. Despite technological progress, alarm acoustics remain largely unchanged and are often perceived as disruptive. To address this, Philips redesigned its patient monitoring alarm sounds through a user-centered approach aimed at improving priority differentiation and reducing emotional strain. Objective: This study provides insights into human-technology interaction by examining anesthesia providers’ experiences with the original and updated alarms, with a focus on emotional responses, usability, and guidance for the user-centered design of future clinical alarm systems. Methods: This single-center qualitative study involved anesthesia providers who completed an online questionnaire before and after the implementation of the updated Philips alarms. Only those who completed the pre-implementation phase participated in the postimplementation phase. The questionnaire included 4 open-ended questions addressing perceptions of the current alarm sounds, suggestions for improvement, design expectations, and attitudes toward an alarm-free operating room. Responses were analyzed using thematic analysis to identify key usability and emotional response themes. Results: A total of 90 eligible anesthesia providers participated in the preimplementation phase, and 77 (85.6%) participated in the postimplementation phase. Positive emotional responses increased in the postimplementation phase, whereas concerns regarding alarm functionality also became more prominent. Before the introduction of the updated alarm sounds, participants predominantly called for softer sounds. Following implementation, the most frequently expressed concern shifted to the need for clearer prioritization of alarms. Across both phases, the primary expectation remained the alarms’ ability to effectively capture attention. The concept of an alarm-free operating room elicited concerns about increased workload and potential risks to patient safety. Conclusions: The redesigned alarm sounds were perceived more positively in terms of emotional acceptance; however, they did not improve the recognition of alarm priority. The modest acoustic changes did not address the broader issue of alarm overload. Suggestions such as visual-only alerts for low-priority alarms show potential but must be balanced with patient safety standards. Future alarm development should combine user feedback with expert-driven and evidence-based approaches to improve both usability and clinical effectiveness.
- 1 April 2026
- Published by JMIR Publications Inc. in JMIR Human Factors
- Vol. 13 (1) , e82703
Open AccessAnesthesia Providers’ Perspectives on the Redesigned Philips Acoustic Alarm System: Qualitative Pre- and Postimplementation Study
Background: Alarm fatigue caused by frequent or false alarms poses a persistent threat to patient safety. Despite technological progress, alarm acoustics remain largely unchanged and are often perceived as disruptive. To address this, Philips redesigned its patient monitoring alarm sounds through a user-centered approach aimed at improving priority differentiation and reducing emotional strain. Objective: This study provides insights into human-technology interaction by examining anesthesia providers’ experiences with the original and updated alarms, with a focus on emotional responses, usability, and guidance for the user-centered design of future clinical alarm systems. Methods: This single-center qualitative study involved anesthesia providers who completed an online questionnaire before and after the implementation of the updated Philips alarms. Only those who completed the pre-implementation phase participated in the postimplementation phase. The questionnaire included 4 open-ended questions addressing perceptions of the current alarm sounds, suggestions for improvement, design expectations, and attitudes toward an alarm-free operating room. Responses were analyzed using thematic analysis to identify key usability and emotional response themes. Results: A total of 90 eligible anesthesia providers participated in the preimplementation phase, and 77 (85.6%) participated in the postimplementation phase. Positive emotional responses increased in the postimplementation phase, whereas concerns regarding alarm functionality also became more prominent. Before the introduction of the updated alarm sounds, participants predominantly called for softer sounds. Following implementation, the most frequently expressed concern shifted to the need for clearer prioritization of alarms. Across both phases, the primary expectation remained the alarms’ ability to effectively capture attention. The concept of an alarm-free operating room elicited concerns about increased workload and potential risks to patient safety. Conclusions: The redesigned alarm sounds were perceived more positively in terms of emotional acceptance; however, they did not improve the recognition of alarm priority. The modest acoustic changes did not address the broader issue of alarm overload. Suggestions such as visual-only alerts for low-priority alarms show potential but must be balanced with patient safety standards. Future alarm development should combine user feedback with expert-driven and evidence-based approaches to improve both usability and clinical effectiveness.
- Open Access
- 12 March 2026
- Published by JMIR Publications Inc. in JMIR Formative Research
- Vol. 10, e84130
Using a Wearable-Based Animated Patient Avatar to Improve Patients’ Perception of Vital Signs: Multicenter Computer-Based Study
Background: Visual patient avatars are an innovative patient monitoring technology that can be used to translate numerical and waveform data into intuitive, avatar-based representations of patient conditions. Previous research indicates that this technology improves health care providers’ situational awareness compared to conventional monitoring methods. As patient-worn continuous vital sign monitoring continues to evolve, we introduce the Visual Patient Wearable device to provide avatar-based visualization tailored to this application. Objective: This study aimed to evaluate whether a wearable-based animated patient avatar can improve patients’ perception and recall of simulated vital sign deviations compared to conventional monitoring methods, and to assess the usability and acceptance of this avatar-based visualization. Methods: This computer-based study included 67 patients from 3 academic hospitals in Central Europe. Participants were randomly assigned to a Visual Patient Wearable group or a conventional monitoring group and viewed a standardized instructional video for their allocated method. They then completed 4 randomized clinical scenarios, each displayed for 6 seconds to simulate glance-based assessment. Accuracy in recalling vital sign deviations was measured, and Visual Patient Wearable participants additionally gave user feedback on Likert scales. Results: The Visual Patient Wearable system was associated with higher detection accuracy of vital sign deviations compared with standard monitoring layouts, increasing from a median correctness of 46% (IQR 33%-63%) with conventional monitoring to a median of 67% (IQR 49%-79%) with the Visual Patient Wearable system (P<.001). This corresponded to a risk ratio of 1.34 (95% CI 1.23%-1.47%). The magnitude of this association varied across signals, with the largest relative improvement observed for heart rhythm (137% improvement, 95% CI 85%-209%), followed by oxygen saturation (SpO2; 64% improvement, 95% CI 30%-108%) and temperature (30% improvement, 95% CI 5%-60%). No statistically significant reductions in risk were observed for heart rate, respiratory rate, or blood pressure. User experience ratings based on Likert scale assessments indicated high levels of satisfaction across all 6 vital sign categories (median score 4, IQR 4-5 on a 5-point scale). Conclusions: This computer-based study suggests that Visual Patient Wearable visualizations enhance patients’ ability to detect and recall simulated vital sign deviations. Participants found the system intuitive, easy to learn, and reassuring. The Visual Patient Wearable system provides an at-a-glance interface that may support patients’ understanding of their vital signs and could facilitate communication of relevant information to clinical staff, thereby potentially contributing to informed patient engagement. The next step is to develop a software prototype for wearable devices and test it in a clinical study.
- 12 March 2026
- Published by JMIR Publications Inc. in JMIR Formative Research
- Vol. 10, e84130
Open AccessUsing a Wearable-Based Animated Patient Avatar to Improve Patients’ Perception of Vital Signs: Multicenter Computer-Based Study
Background: Visual patient avatars are an innovative patient monitoring technology that can be used to translate numerical and waveform data into intuitive, avatar-based representations of patient conditions. Previous research indicates that this technology improves health care providers’ situational awareness compared to conventional monitoring methods. As patient-worn continuous vital sign monitoring continues to evolve, we introduce the Visual Patient Wearable device to provide avatar-based visualization tailored to this application. Objective: This study aimed to evaluate whether a wearable-based animated patient avatar can improve patients’ perception and recall of simulated vital sign deviations compared to conventional monitoring methods, and to assess the usability and acceptance of this avatar-based visualization. Methods: This computer-based study included 67 patients from 3 academic hospitals in Central Europe. Participants were randomly assigned to a Visual Patient Wearable group or a conventional monitoring group and viewed a standardized instructional video for their allocated method. They then completed 4 randomized clinical scenarios, each displayed for 6 seconds to simulate glance-based assessment. Accuracy in recalling vital sign deviations was measured, and Visual Patient Wearable participants additionally gave user feedback on Likert scales. Results: The Visual Patient Wearable system was associated with higher detection accuracy of vital sign deviations compared with standard monitoring layouts, increasing from a median correctness of 46% (IQR 33%-63%) with conventional monitoring to a median of 67% (IQR 49%-79%) with the Visual Patient Wearable system (P<.001). This corresponded to a risk ratio of 1.34 (95% CI 1.23%-1.47%). The magnitude of this association varied across signals, with the largest relative improvement observed for heart rhythm (137% improvement, 95% CI 85%-209%), followed by oxygen saturation (SpO2; 64% improvement, 95% CI 30%-108%) and temperature (30% improvement, 95% CI 5%-60%). No statistically significant reductions in risk were observed for heart rate, respiratory rate, or blood pressure. User experience ratings based on Likert scale assessments indicated high levels of satisfaction across all 6 vital sign categories (median score 4, IQR 4-5 on a 5-point scale). Conclusions: This computer-based study suggests that Visual Patient Wearable visualizations enhance patients’ ability to detect and recall simulated vital sign deviations. Participants found the system intuitive, easy to learn, and reassuring. The Visual Patient Wearable system provides an at-a-glance interface that may support patients’ understanding of their vital signs and could facilitate communication of relevant information to clinical staff, thereby potentially contributing to informed patient engagement. The next step is to develop a software prototype for wearable devices and test it in a clinical study.
- Open Access
- 24 November 2025
- Published by MDPI AG in Healthcare
- Vol. 13 (23) , 3033
User-Centered Redesign of Monitoring Alarms: A Pre–Post Study on Perception, Functionality, and Recognizability Following Real-Life Clinical Implementation
Background: Auditory alarms in patient monitoring are vital for clinical safety, but their harsh acoustic properties and high frequency contribute to stress, alarm fatigue, and reduced acceptance among healthcare staff. In collaboration with Sen Sound, Philips redesigned its alarm sounds to reduce auditory harshness, particularly for low- and medium-priority alarms, while preserving the salience of high-priority alerts. This study evaluated the impact of these refined alarm sounds in a real-world clinical setting. Objective: The goal was to determine whether anesthesia professionals perceive the refined Philips alarm sounds as more pleasant, clinically appropriate, and reliably recognizable compared with the traditional sounds. Methods: We conducted a single-center, pre–post intervention study at the University Hospital Zurich, Switzerland. Anesthesia providers assessed traditional and refined Philips alarm sounds with respect to perceived sound appeal, perceived functionality, and recognition accuracy. The primary outcome (sound appeal) was tested for superiority; using mixed-effects regression models. Results: Seventy-seven participants completed both study phases. Refined alarm sounds significantly improved perceived sound appeal (mean difference +0.51; 95% CI, 0.37–0.64; p < 0.001), while perceived functionality showed a small decrease (mean difference −0.15; 95% CI, −0.27 to −0.03). Recognition accuracy for low- and medium-priority alarms was higher with traditional sounds (low: 95.2% vs. 87.5%, p = 0.002; medium: 81.1% vs. 62.0%, p < 0.001), while high-priority alarms were more accurately identified with refined sounds (89.0% vs. 81.4%, p = 0.002). Overall, 71% of participants preferred the refined sounds, and 92% supported further development. Conclusions: Refined alarm sounds reduced perceived harshness and improved auditory comfort for anesthesia providers, but were associated with slightly lower perceived functionality and mixed recognition accuracy. High-priority alarms were identified more reliably, whereas low- and medium-priority alarms were less distinctly recognized, indicating a limited trade-off between sound appeal and clarity that primarily affected lower-priority signals. These findings suggest that while refinement can enhance the auditory environment, further development, potentially incorporating auditory icons or voice-based alerts, will be needed to optimize both user experience and patient safety in clinical practice.
- 24 November 2025
- Published by MDPI AG in Healthcare
- Vol. 13 (23) , 3033
Open AccessUser-Centered Redesign of Monitoring Alarms: A Pre–Post Study on Perception, Functionality, and Recognizability Following Real-Life Clinical Implementation
Background: Auditory alarms in patient monitoring are vital for clinical safety, but their harsh acoustic properties and high frequency contribute to stress, alarm fatigue, and reduced acceptance among healthcare staff. In collaboration with Sen Sound, Philips redesigned its alarm sounds to reduce auditory harshness, particularly for low- and medium-priority alarms, while preserving the salience of high-priority alerts. This study evaluated the impact of these refined alarm sounds in a real-world clinical setting. Objective: The goal was to determine whether anesthesia professionals perceive the refined Philips alarm sounds as more pleasant, clinically appropriate, and reliably recognizable compared with the traditional sounds. Methods: We conducted a single-center, pre–post intervention study at the University Hospital Zurich, Switzerland. Anesthesia providers assessed traditional and refined Philips alarm sounds with respect to perceived sound appeal, perceived functionality, and recognition accuracy. The primary outcome (sound appeal) was tested for superiority; using mixed-effects regression models. Results: Seventy-seven participants completed both study phases. Refined alarm sounds significantly improved perceived sound appeal (mean difference +0.51; 95% CI, 0.37–0.64; p < 0.001), while perceived functionality showed a small decrease (mean difference −0.15; 95% CI, −0.27 to −0.03). Recognition accuracy for low- and medium-priority alarms was higher with traditional sounds (low: 95.2% vs. 87.5%, p = 0.002; medium: 81.1% vs. 62.0%, p < 0.001), while high-priority alarms were more accurately identified with refined sounds (89.0% vs. 81.4%, p = 0.002). Overall, 71% of participants preferred the refined sounds, and 92% supported further development. Conclusions: Refined alarm sounds reduced perceived harshness and improved auditory comfort for anesthesia providers, but were associated with slightly lower perceived functionality and mixed recognition accuracy. High-priority alarms were identified more reliably, whereas low- and medium-priority alarms were less distinctly recognized, indicating a limited trade-off between sound appeal and clarity that primarily affected lower-priority signals. These findings suggest that while refinement can enhance the auditory environment, further development, potentially incorporating auditory icons or voice-based alerts, will be needed to optimize both user experience and patient safety in clinical practice.
- Open Access
- 15 September 2025
- Published by JMIR Publications Inc. in JMIR Preprints
Using a Wearable-Based Animated Patient Avatar to Improve Patients’ Perception of Vital Signs: Multicenter Computer-Based Study (Preprint)
BACKGROUND Visual patient avatars are an innovative patient monitoring technology that can be used to translate numerical and waveform data into intuitive, avatar-based representations of patient conditions. Previous research indicates that this technology improves health care providers’ situational awareness compared to conventional monitoring methods. As patient-worn continuous vital sign monitoring continues to evolve, we introduce the Visual Patient Wearable device to provide avatar-based visualization tailored to this application. OBJECTIVE This study aimed to evaluate whether a wearable-based animated patient avatar can improve patients’ perception and recall of simulated vital sign deviations compared to conventional monitoring methods, and to assess the usability and acceptance of this avatar-based visualization. METHODS This computer-based study included 67 patients from 3 academic hospitals in Central Europe. Participants were randomly assigned to a Visual Patient Wearable group or a conventional monitoring group and viewed a standardized instructional video for their allocated method. They then completed 4 randomized clinical scenarios, each displayed for 6 seconds to simulate glance-based assessment. Accuracy in recalling vital sign deviations was measured, and Visual Patient Wearable participants additionally gave user feedback on Likert scales. RESULTS The Visual Patient Wearable system was associated with higher detection accuracy of vital sign deviations compared with standard monitoring layouts, increasing from a median correctness of 46% (IQR 33%-63%) with conventional monitoring to a median of 67% (IQR 49%-79%) with the Visual Patient Wearable system (P<.001). This corresponded to a risk ratio of 1.34 (95% CI 1.23%-1.47%). The magnitude of this association varied across signals, with the largest relative improvement observed for heart rhythm (137% improvement, 95% CI 85%-209%), followed by oxygen saturation (SpO2; 64% improvement, 95% CI 30%-108%) and temperature (30% improvement, 95% CI 5%-60%). No statistically significant reductions in risk were observed for heart rate, respiratory rate, or blood pressure. User experience ratings based on Likert scale assessments indicated high levels of satisfaction across all 6 vital sign categories (median score 4, IQR 4-5 on a 5-point scale). CONCLUSIONS This computer-based study suggests that Visual Patient Wearable visualizations enhance patients’ ability to detect and recall simulated vital sign deviations. Participants found the system intuitive, easy to learn, and reassuring. The Visual Patient Wearable system provides an at-a-glance interface that may support patients’ understanding of their vital signs and could facilitate communication of relevant information to clinical staff, thereby potentially contributing to informed patient engagement. The next step is to develop a software prototype for wearable devices and test it in a clinical study.
- 15 September 2025
- Published by JMIR Publications Inc. in JMIR Preprints
Open AccessUsing a Wearable-Based Animated Patient Avatar to Improve Patients’ Perception of Vital Signs: Multicenter Computer-Based Study (Preprint)
BACKGROUND Visual patient avatars are an innovative patient monitoring technology that can be used to translate numerical and waveform data into intuitive, avatar-based representations of patient conditions. Previous research indicates that this technology improves health care providers’ situational awareness compared to conventional monitoring methods. As patient-worn continuous vital sign monitoring continues to evolve, we introduce the Visual Patient Wearable device to provide avatar-based visualization tailored to this application. OBJECTIVE This study aimed to evaluate whether a wearable-based animated patient avatar can improve patients’ perception and recall of simulated vital sign deviations compared to conventional monitoring methods, and to assess the usability and acceptance of this avatar-based visualization. METHODS This computer-based study included 67 patients from 3 academic hospitals in Central Europe. Participants were randomly assigned to a Visual Patient Wearable group or a conventional monitoring group and viewed a standardized instructional video for their allocated method. They then completed 4 randomized clinical scenarios, each displayed for 6 seconds to simulate glance-based assessment. Accuracy in recalling vital sign deviations was measured, and Visual Patient Wearable participants additionally gave user feedback on Likert scales. RESULTS The Visual Patient Wearable system was associated with higher detection accuracy of vital sign deviations compared with standard monitoring layouts, increasing from a median correctness of 46% (IQR 33%-63%) with conventional monitoring to a median of 67% (IQR 49%-79%) with the Visual Patient Wearable system (P<.001). This corresponded to a risk ratio of 1.34 (95% CI 1.23%-1.47%). The magnitude of this association varied across signals, with the largest relative improvement observed for heart rhythm (137% improvement, 95% CI 85%-209%), followed by oxygen saturation (SpO2; 64% improvement, 95% CI 30%-108%) and temperature (30% improvement, 95% CI 5%-60%). No statistically significant reductions in risk were observed for heart rate, respiratory rate, or blood pressure. User experience ratings based on Likert scale assessments indicated high levels of satisfaction across all 6 vital sign categories (median score 4, IQR 4-5 on a 5-point scale). CONCLUSIONS This computer-based study suggests that Visual Patient Wearable visualizations enhance patients’ ability to detect and recall simulated vital sign deviations. Participants found the system intuitive, easy to learn, and reassuring. The Visual Patient Wearable system provides an at-a-glance interface that may support patients’ understanding of their vital signs and could facilitate communication of relevant information to clinical staff, thereby potentially contributing to informed patient engagement. The next step is to develop a software prototype for wearable devices and test it in a clinical study.
- Open Access
- 20 August 2025
- Published by JMIR Publications Inc. in JMIR Preprints
Anaesthesia Providers’ Perspectives on the Redesigned Philips Acoustic Alarm System: A Qualitative Pre- and Post-Implementation Study (Preprint)
BACKGROUND Alarm fatigue caused by frequent or false alarms poses a persistent threat to patient safety. Despite technological progress, alarm acoustics remain largely unchanged and are often perceived as disruptive. To address this, Philips redesigned its patient monitoring alarm sounds using a user-centred approach aimed at improving priority differentiation and reducing emotional strain. OBJECTIVE This study provides insights into human–technology interaction by examining anaesthesia providers’ experiences with original and updated alarms, with a focus on emotional responses, usability, and guidance for the user-centred design of future clinical alarm systems. METHODS This single-centre qualitative study involved anaesthesia providers who completed an online questionnaire before and after implementation of the updated Philips alarms. Only those who completed the pre-phase participated in the post-phase. The questionnaire included four open-ended questions addressing perceptions of the current alarm sounds, suggestions for improvement, design expectations, and attitudes toward an alarm-free operating room. Responses were analysed using thematic analysis to identify key usability and emotional response themes, while quantitative data were summarised descriptively. RESULTS Ninety eligible providers participated in the pre- and 77 in the post-implementation phase. Positive emotional responses increased in the post-implementation phase, whereas concerns regarding alarm functionality also became more prominent. Prior to the introduction of the updated alarm sounds, participants predominantly called for softer alarm sounds. Following implementation, the most frequently expressed concern shifted to the need for clearer prioritisation of alarms. Across both phases, the primary expectation remained the alarms’ ability to effectively capture attention. The concept of an alarm-free operating room elicited concerns about increased workload and potential risks to patient safety. CONCLUSIONS The redesigned alarm sounds were better accepted emotionally; however, they did not improve the recognition of alarm priority. The modest acoustic changes did not address the broader issue of alarm overload. Suggestions such as visual-only alerts for low-priority alarms show potential but must be balanced with patient safety standards. Future alarm development should combine user feedback with expert-driven and evidence-based approaches to improve both usability and clinical effectiveness. CLINICALTRIAL Cantonal Ethics Committee Zurich (Req-2022-00689)
- 20 August 2025
- Published by JMIR Publications Inc. in JMIR Preprints
Open AccessAnaesthesia Providers’ Perspectives on the Redesigned Philips Acoustic Alarm System: A Qualitative Pre- and Post-Implementation Study (Preprint)
BACKGROUND Alarm fatigue caused by frequent or false alarms poses a persistent threat to patient safety. Despite technological progress, alarm acoustics remain largely unchanged and are often perceived as disruptive. To address this, Philips redesigned its patient monitoring alarm sounds using a user-centred approach aimed at improving priority differentiation and reducing emotional strain. OBJECTIVE This study provides insights into human–technology interaction by examining anaesthesia providers’ experiences with original and updated alarms, with a focus on emotional responses, usability, and guidance for the user-centred design of future clinical alarm systems. METHODS This single-centre qualitative study involved anaesthesia providers who completed an online questionnaire before and after implementation of the updated Philips alarms. Only those who completed the pre-phase participated in the post-phase. The questionnaire included four open-ended questions addressing perceptions of the current alarm sounds, suggestions for improvement, design expectations, and attitudes toward an alarm-free operating room. Responses were analysed using thematic analysis to identify key usability and emotional response themes, while quantitative data were summarised descriptively. RESULTS Ninety eligible providers participated in the pre- and 77 in the post-implementation phase. Positive emotional responses increased in the post-implementation phase, whereas concerns regarding alarm functionality also became more prominent. Prior to the introduction of the updated alarm sounds, participants predominantly called for softer alarm sounds. Following implementation, the most frequently expressed concern shifted to the need for clearer prioritisation of alarms. Across both phases, the primary expectation remained the alarms’ ability to effectively capture attention. The concept of an alarm-free operating room elicited concerns about increased workload and potential risks to patient safety. CONCLUSIONS The redesigned alarm sounds were better accepted emotionally; however, they did not improve the recognition of alarm priority. The modest acoustic changes did not address the broader issue of alarm overload. Suggestions such as visual-only alerts for low-priority alarms show potential but must be balanced with patient safety standards. Future alarm development should combine user feedback with expert-driven and evidence-based approaches to improve both usability and clinical effectiveness. CLINICALTRIAL Cantonal Ethics Committee Zurich (Req-2022-00689)
- 17 April 2025
- Published by Elsevier in British Journal of Anaesthesia
- Vol. 134 (6) , 1616-1619
The future of sound in patient monitoring: a call to action to embrace the evidence and move forward
- 17 April 2025
- Published by Elsevier in British Journal of Anaesthesia
- Vol. 134 (6) , 1616-1619
The future of sound in patient monitoring: a call to action to embrace the evidence and move forward
- 1 August 2024
- Published by Elsevier in British Journal of Anaesthesia
- Vol. 133 (4) , 889-892
Predicting vital sign deviations during surgery from patient monitoring data: developing and validating single-stream deep learning models
- 1 August 2024
- Published by Elsevier in British Journal of Anaesthesia
- Vol. 133 (4) , 889-892
Predicting vital sign deviations during surgery from patient monitoring data: developing and validating single-stream deep learning models
- Open Access
- 11 January 2024
- Published by JMIR Publications Inc. in JMIR Human Factors
- Vol. 11 (1) , e47991
User Perceptions of Visual Clot in a High-Fidelity Simulation Study: Mixed Qualitative-Quantitative Study
Background: Viscoelastic hemostatic assays, such as rotational thromboelastometry (ROTEM) or thromboelastography, enable prompt diagnosis and accelerate targeted treatment. However, the complex interpretation of the results remains challenging. Visual Clot—a situation awareness-based visualization technology—was developed to assist clinicians in interpreting viscoelastic tests. Objective: Following a previous high-fidelity simulation study, we analyzed users’ perceptions of the technology, to identify its strengths and limitations from clinicians’ perspectives. Methods: This is a mixed qualitative-quantitative study consisting of interviews and a survey. After solving coagulation scenarios using Visual Clot in high-fidelity simulations, we interviewed anesthesia personnel about the perceived advantages and disadvantages of the new tool. We used a template approach to identify dominant themes in interview responses. From these themes, we defined 5 statements, which were then rated on Likert scales in a questionnaire. Results: We interviewed 77 participants and 23 completed the survey. We identified 9 frequently mentioned topics by analyzing the interview responses. The most common themes were “positive design features,” “intuitive and easy to learn,” and “lack of a quantitative component.” In the survey, 21 respondents agreed that Visual Clot is easy to learn and 16 respondents stated that a combination of Visual Clot and ROTEM would help them manage complex hemostatic situations. Conclusions: A group of anesthesia care providers found Visual Clot well-designed, intuitive, and easy to learn. Participants highlighted its usefulness in emergencies, especially for clinicians inexperienced in coagulation management. However, the lack of quantitative information is an area for improvement.
- 11 January 2024
- Published by JMIR Publications Inc. in JMIR Human Factors
- Vol. 11 (1) , e47991
Open AccessUser Perceptions of Visual Clot in a High-Fidelity Simulation Study: Mixed Qualitative-Quantitative Study
Background: Viscoelastic hemostatic assays, such as rotational thromboelastometry (ROTEM) or thromboelastography, enable prompt diagnosis and accelerate targeted treatment. However, the complex interpretation of the results remains challenging. Visual Clot—a situation awareness-based visualization technology—was developed to assist clinicians in interpreting viscoelastic tests. Objective: Following a previous high-fidelity simulation study, we analyzed users’ perceptions of the technology, to identify its strengths and limitations from clinicians’ perspectives. Methods: This is a mixed qualitative-quantitative study consisting of interviews and a survey. After solving coagulation scenarios using Visual Clot in high-fidelity simulations, we interviewed anesthesia personnel about the perceived advantages and disadvantages of the new tool. We used a template approach to identify dominant themes in interview responses. From these themes, we defined 5 statements, which were then rated on Likert scales in a questionnaire. Results: We interviewed 77 participants and 23 completed the survey. We identified 9 frequently mentioned topics by analyzing the interview responses. The most common themes were “positive design features,” “intuitive and easy to learn,” and “lack of a quantitative component.” In the survey, 21 respondents agreed that Visual Clot is easy to learn and 16 respondents stated that a combination of Visual Clot and ROTEM would help them manage complex hemostatic situations. Conclusions: A group of anesthesia care providers found Visual Clot well-designed, intuitive, and easy to learn. Participants highlighted its usefulness in emergencies, especially for clinicians inexperienced in coagulation management. However, the lack of quantitative information is an area for improvement.
- Open Access
- 12 November 2023
- Published by MDPI AG in Diagnostics
- Vol. 13 (22) , 3432
The Visual Patient Avatar ICU Facilitates Information Transfer of Written Information by Visualization: A Multicenter Comparative Eye-Tracking Study
Patient monitoring is crucial in critical care medicine. Perceiving and interpreting multiple vital signs requires a high workload that can lead to decreased situation awareness and consequently inattentional blindness, defined as impaired perception of unexpectedly changing data. To facilitate information transfer, we developed and validated the Visual-Patient avatar. Generated by numerical data, the animation displays the status of vital signs and patient installations according to a user-centered design to improve situation awareness. As a surrogate parameter for information transfer in patient monitoring, we recorded visual attention using eye-tracking data. In this computer-based study, we compared the correlation of visually perceived and correctly interpreted vital signs between a Visual-Patient-avatar ICU and conventional patient monitoring. A total of 50 recruited study participants (25 nurses, 25 physicians) from five European study centers completed five randomized scenarios in both modalities. Using a stationary eye tracker as the primary endpoint, we recorded how long different areas of interest of the two monitoring modalities were viewed. In addition, we tested for a possible association between the length of time an area of interest was viewed and the correctness of the corresponding question. With the conventional monitor, participants looked at the installation site the longest (median 2.13–2.51 s). With the Visual-Patient-avatar ICU, gaze distribution was balanced; no area of interest was viewed for particularly long. For both modalities, the longer an area was viewed, the more likely the associated question was answered incorrectly (OR 0.97, 95% CI 0.95–0.99, p = 0.008). The Visual-Patient-avatar ICU facilitates and improves information transfer through its visualizations, especially with written information. The longer an area of interest was viewed, the more likely the associated question was answered incorrectly.
- 12 November 2023
- Published by MDPI AG in Diagnostics
- Vol. 13 (22) , 3432
Open AccessThe Visual Patient Avatar ICU Facilitates Information Transfer of Written Information by Visualization: A Multicenter Comparative Eye-Tracking Study
Patient monitoring is crucial in critical care medicine. Perceiving and interpreting multiple vital signs requires a high workload that can lead to decreased situation awareness and consequently inattentional blindness, defined as impaired perception of unexpectedly changing data. To facilitate information transfer, we developed and validated the Visual-Patient avatar. Generated by numerical data, the animation displays the status of vital signs and patient installations according to a user-centered design to improve situation awareness. As a surrogate parameter for information transfer in patient monitoring, we recorded visual attention using eye-tracking data. In this computer-based study, we compared the correlation of visually perceived and correctly interpreted vital signs between a Visual-Patient-avatar ICU and conventional patient monitoring. A total of 50 recruited study participants (25 nurses, 25 physicians) from five European study centers completed five randomized scenarios in both modalities. Using a stationary eye tracker as the primary endpoint, we recorded how long different areas of interest of the two monitoring modalities were viewed. In addition, we tested for a possible association between the length of time an area of interest was viewed and the correctness of the corresponding question. With the conventional monitor, participants looked at the installation site the longest (median 2.13–2.51 s). With the Visual-Patient-avatar ICU, gaze distribution was balanced; no area of interest was viewed for particularly long. For both modalities, the longer an area was viewed, the more likely the associated question was answered incorrectly (OR 0.97, 95% CI 0.95–0.99, p = 0.008). The Visual-Patient-avatar ICU facilitates and improves information transfer through its visualizations, especially with written information. The longer an area of interest was viewed, the more likely the associated question was answered incorrectly.
- Open Access
- 6 November 2023
- Published by MDPI AG in Diagnostics
- Vol. 13 (21) , 3391
User Perceptions of Avatar-Based Patient Monitoring for Intensive Care Units: An International Exploratory Sequential Mixed-Methods Study
Visual Patient Avatar ICU is an innovative approach to patient monitoring, enhancing the user’s situation awareness in intensive care settings. It dynamically displays the patient’s current vital signs using changes in color, shape, and animation. The technology can also indicate patient-inserted devices, such as arterial lines, central lines, and urinary catheters, along with their insertion locations. We conducted an international, multi-center study using a sequential qualitative-quantitative design to evaluate users’ perception of Visual Patient Avatar ICU among physicians and nurses. Twenty-five nurses and twenty-five physicians from the ICU participated in the structured interviews. Forty of them completed the online survey. Overall, ICU professionals expressed a positive outlook on Visual Patient Avatar ICU. They described Visual Patient Avatar ICU as a simple and intuitive tool that improved information retention and facilitated problem identification. However, a subset of participants expressed concerns about potential information overload and a sense of incompleteness due to missing exact numerical values. These findings provide valuable insights into user perceptions of Visual Patient Avatar ICU and encourage further technology development before clinical implementation.
- 6 November 2023
- Published by MDPI AG in Diagnostics
- Vol. 13 (21) , 3391
Open AccessUser Perceptions of Avatar-Based Patient Monitoring for Intensive Care Units: An International Exploratory Sequential Mixed-Methods Study
Visual Patient Avatar ICU is an innovative approach to patient monitoring, enhancing the user’s situation awareness in intensive care settings. It dynamically displays the patient’s current vital signs using changes in color, shape, and animation. The technology can also indicate patient-inserted devices, such as arterial lines, central lines, and urinary catheters, along with their insertion locations. We conducted an international, multi-center study using a sequential qualitative-quantitative design to evaluate users’ perception of Visual Patient Avatar ICU among physicians and nurses. Twenty-five nurses and twenty-five physicians from the ICU participated in the structured interviews. Forty of them completed the online survey. Overall, ICU professionals expressed a positive outlook on Visual Patient Avatar ICU. They described Visual Patient Avatar ICU as a simple and intuitive tool that improved information retention and facilitated problem identification. However, a subset of participants expressed concerns about potential information overload and a sense of incompleteness due to missing exact numerical values. These findings provide valuable insights into user perceptions of Visual Patient Avatar ICU and encourage further technology development before clinical implementation.