HTHiroyuki Tetsuka

Hiroyuki Tetsuka

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Hiroyuki Tetsuka has a total of 62 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Wireless bioelectronic control architectures for muscle-powered biohybrid robotic systems

    by Hiroyuki Tetsuka, Minoru Hirano

    Wireless bioelectronic interfaces are increasingly used to control tissue-engineered, muscle-powered biohybrid robotic systems. However, a unifying engineering framework linking device design to system-level control remains underdeveloped. Here, we formulate wireless control in biohybrid robotics as a coupled co-design problem integrating signal delivery, spatial selectivity, scalability, sensing and feedback, controller implementation, biological life support, and interface stability. We analyze three representative actuation and control strategies—wireless electrical stimulation, wireless optoelectronic stimulation, and neuromuscular integration—which operate in distinct regimes with characteristic trade-offs. Across these modalities, the tissue–device interface emerges as a key constraint governing the interplay among electrical or optical signal delivery, circuit performance, sensing, and biomechanical response. We outline practical design principles spanning electromagnetic field distribution, circuit architecture, actuator mechanics, multi-actuator addressing, and closed-loop control. Rather than treating neural organoids as an inevitable end point, we compare conventional electronic controllers, neuronal culture–silicon interfaces, and organoid–microelectrode array systems as alternative trajectories toward closed-loop autonomy. This system-level perspective provides design guidelines for stable, scalable, and application-driven biohybrid robotic systems.

  • Open Access

    Miniaturized wireless bioelectronics for electrically driven biohybrid robots

    by Hiroyuki Tetsuka, Jiaju Ma, Minoru Hirano

    Although biohybrid robots offer the potential for soft, adaptive actuation by harnessing living muscle, practical operation in cell culture environments is often limited by the requirement of immersed leads or cumbersome stimulation equipment. Here, we present a thin, miniaturized, wireless bioelectronic stimulator that can electrically drive biohybrid robots while maintaining stability in aqueous cell culture media. Built on a 50-µm liquid crystal polymer (LCP) substrate, the device integrates a planar receiving coil, interconnects, a diode-based rectifier, and a tank capacitor. This enables the device to convert an approximately 4.9-MHz radio-frequency (RF) input into pulsed direct current (DC), which is delivered through integrated stimulation electrodes. The stimulator has a footprint of ~ 32 mm² and a total thickness and mass of ~ 100 μm and ~ 7 mg, respectively. We integrated the stimulator with a nanopatterned carbon nanotube (CNT)/gelatin hydrogel fin seeded with human induced pluripotent stem cell-derived cardiomyocytes (iPSC-CMs) to generate propulsion through fin flapping. By optimizing the thickness of the polydimethylsiloxane (PDMS) encapsulation layer, the density was tuned, and the robot remained freely floating and retained shape integrity during operation. This produced autonomous forward locomotion of 74.8 ± 16.4 μm s − 1 . The stimulator generated distance-dependent output voltage pulses and enabled external pacing/modulation under the tested conditions, without a marked loss of cardiomyocyte attachment or α-actinin-positive sarcomeric organization. Together, these results provide a proof-of-concept compact, media-compatible, wireless bioelectronic interface toward closed-system biohybrid robotics.


  • Open Access

    Miniaturized wireless bioelectronics for electrically driven biohybrid robots

    by Hiroyuki Tetsuka, Jiaju Ma, Minoru Hirano

    Although biohybrid robots offer the potential for soft, adaptive actuation by harnessing living muscle, practical operation in cell culture environments is often limited by the requirement of immersed leads or cumbersome stimulation equipment. Here, we present a thin, miniaturized, wireless bioelectronic stimulator that can electrically drive biohybrid robots while maintaining stability in aqueous cell culture media. Built on a 50-µm liquid crystal polymer (LCP) substrate, the device integrates a planar receiving coil, interconnects, a diode-based rectifier, and a tank capacitor. This enables the device to convert an approximately 4.9-MHz radio-frequency (RF) input into pulsed direct current (DC), which is delivered through integrated stimulation electrodes. The stimulator has a footprint of ∼23 mm 2 and a total thickness and mass of ∼100 µm and ∼7 mg, respectively. We integrated the stimulator with a nanopatterned carbon nanotube (CNT)/gelatin hydrogel fin seeded with human induced pluripotent stem cell-derived cardiomyocytes (iPSC-CMs) to generate propulsion through fin flapping. By optimizing the thickness of the polydimethylsiloxane (PDMS) encapsulation layer, the density was tuned, and the robot remained freely floating and retained shape integrity during operation. This produced autonomous forward locomotion of ∼70 µm/s. The stimulator generated distance-dependent output voltage pulses of ∼2–6 V and reliably synchronized fin flapping rates of up to 2 Hz without an observable loss of cell attachment or sarcomeric organization. Together, these results establish a compact, media-compatible, wireless, bioelectronic interface suitable for closed-system biohybrid robotics.

  • Wirelessly steerable bioelectronic neuromuscular robots adapting neurocardiac junctions

    by Hiroyuki Tetsuka, Samuele Gobbi, Takaaki Hatanaka, Lorenzo Pirrami, Su Ryon Shin

    Biological motions of native muscle tissues rely on the nervous system to interface movement with the surrounding environment. The neural innervation of muscles, crucial for regulating movement, is the fundamental infrastructure for swiftly responding to changes in body tissue requirements. This study introduces a bioelectronic neuromuscular robot integrated with the motor nervous system through electrical synapses to evoke cardiac muscle activities and steer robotic motion. Serving as an artificial brain and wirelessly regulating selective neural activation to initiate robot fin motion, a wireless frequency multiplexing bioelectronic device is used to control the robot. Frequency multiplexing bioelectronics enables the control of the robot locomotion speed and direction by modulating the flapping of the robot fins through the wireless motor innervation of cardiac muscles. The robots demonstrated an average locomotion speed of ~0.52 ± 0.22 millimeters per second, fin-flapping frequency up to 2.0 hertz, and turning locomotion path curvature of ~0.11 ± 0.04 radians per millimeter. These systems will contribute to the expansion of biohybrid machines into the brain-to-motor frontier for developing autonomous biohybrid systems capable of advanced adaptive motor control and learning.


  • Materials and technical innovations in 3D printing in biomedical applications

    by Hiroyuki Tetsuka, Su Ryon Shin

    This review highlights the recent advancements of new materials and 3D printing techniques developed to address the unfulfilled needs of the conventional 3D printing methodologies in biomedical applications.


  • Nitrogen‐Functionalized Graphene Quantum Dots: A Versatile Platform for Integrated Optoelectronic Devices

    by Hiroyuki Tetsuka

    Over the past 10 years, graphene quantum dots (GQDs) have grown into a highly innovative optical material in various research fields, including electronics, photonics, biotechnologies, etc. With the increasing implementation of GQDs in these fields, GQDs with tunable optical properties will emerge that could be especially suitable for applications in the field of integrated photonics. Herein, a short summary of the recent state of our research on the development of nitrogen‐functionalized GQDs with tunable optical properties and their integration into photodetectors is given.


  • Non-ionic Fluorosurfactant Improves Wettability of Nitrogen-functionalized Graphene Quantum Dots for Integration with Optoelectronic Devices

    by Hiroyuki Tetsuka, Takayuki Matsui

    Combining high mobility graphene transistors with efficient light-absorbing graphene quantum dots produces highly sensitive photodetectors with wide spectral response. However, an inherent difficulty in fabricating such devices is the wettability of the hydrophilic graphene quantum dots onto the hydrophobic graphene transistor array. We describe a smooth, uniform coating of a graphene quantum dot layer by adding a non-ionic fluorosurfactant: Capstone FS-30. It reduces the surface tension of hydrophilic graphene quantum dots on the hydrophobic substrate, sufficiently improving the wetting property.