Ziad Khalifa
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ziad Khalifa has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
- Sameh Osama Abdellatif
The British University in Egypt (BUE)
5 shared publications - Moustafa Zahran
Institute of Intelligent Manufacturing Technology, Shenzhen Polytechnic University, Shenzhen, 518055, People’s Republic of China
3 shared publications - Amira Ali
FabLab, Centre for Emerging Learning Technologies (CELT), BUE, Elshrouk, Cairo, Egypt
2 shared publications Magdi Abdel Azzem
2 shared publications- Magdi Abdel Azzem
Menoufia Univ, Fac Sci, Chem Dept, Shibin Al Kawm 32511, Egypt
2 shared publications Magdy A-H Zahran
2 shared publications
Latest Publications
- Open Access
- 11 November 2026
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 16 (49) , 66744-66759
Interface coupled MoS 2 @NiCoV-LDH heterostructures for efficient water splitting: synergistic synthesis and DFT insights
Schematic diagram of a bifunctional alkaline electrocatalyst for water splitting using MoS 2 @NiCoV-LDH/NF as cathode and anode.
- 11 November 2026
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 16 (49) , 66744-66759
Open AccessInterface coupled MoS 2 @NiCoV-LDH heterostructures for efficient water splitting: synergistic synthesis and DFT insights
Schematic diagram of a bifunctional alkaline electrocatalyst for water splitting using MoS 2 @NiCoV-LDH/NF as cathode and anode.
- 2 June 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Letters
- Vol. 10 (7) , 1501404
Experimentally Verified Numerical Model of Time-Dependent Degradation and Defects in OFETs for Sensing Applications
This study presents an experimentally verified numerical model addressing time-dependent degradation and defect profiles in organic field-effect transistors (OFETs). We identified a significant research gap in understanding the interplay between defects and degradation mechanisms, which are crucial for enhancing OFET performance and reliability. Notably, our findings showed that the threshold voltage increased from 0.47 V to 1.70 V in bottom gate/top contact devices due to charge trap accumulation, while carrier mobility dropped from 5.1 cm²/V·s to 3.3 cm²/V·s. The model also captures the impact of environmental factors, with the simulation revealing a maximum RMSE deviation of 5.1%, underscoring threshold voltage as the most critical parameter affected by degradation. This comprehensive analysis provides valuable insights for future OFET optimization.
- 2 June 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Letters
- Vol. 10 (7) , 1501404
Experimentally Verified Numerical Model of Time-Dependent Degradation and Defects in OFETs for Sensing Applications
This study presents an experimentally verified numerical model addressing time-dependent degradation and defect profiles in organic field-effect transistors (OFETs). We identified a significant research gap in understanding the interplay between defects and degradation mechanisms, which are crucial for enhancing OFET performance and reliability. Notably, our findings showed that the threshold voltage increased from 0.47 V to 1.70 V in bottom gate/top contact devices due to charge trap accumulation, while carrier mobility dropped from 5.1 cm²/V·s to 3.3 cm²/V·s. The model also captures the impact of environmental factors, with the simulation revealing a maximum RMSE deviation of 5.1%, underscoring threshold voltage as the most critical parameter affected by degradation. This comprehensive analysis provides valuable insights for future OFET optimization.
- 20 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (13) , 24473-24484
Experimentally Driven Numerical Model of Carbon/Polyaniline-Based Glucose Monitoring Sensors: An Evaluation Using a New Figure of Merit
This study presents an experimentally driven numerical model for evaluating carbon/polyaniline (PANI)-based glucose monitoring sensors, focusing on innovative configurations using graphene-PANI and carbon nanotube (CNT)-PANI composites. We performed a thorough analysis of the morphological, electrophysical, and electrical properties of these materials, ultimately leading to the extraction of key electrical parameters for integration into a finite element model (FEM). This model simulates the entire sensor, enabling the estimation of critical performance metrics such as sensitivity, limit of detection (LOD), linearity, and power consumption. Our findings demonstrate that the CNT-PANI configuration significantly outperforms the laser induced graphene (LIG)-PANI electrode, achieving a figure of merit (FOM) of 0.99 compared to 0.62, thanks to its superior electrical conductivity and high surface area, which facilitates enhanced charge transfer and electrochemical reactions. The optimized sensor configurations reveal optimal parameters for LIG-PANI and CNT-PANI, underscoring the trade-offs between conductivity and overall sensor performance. Notably, the CNT-PANI composite exhibits the highest sensitivity of 2778 μA mM-1 cm-2 and the lowest LOD of 0.09 μM, making it a promising candidate for glucose detection in clinical applications. This work highlights the importance of power consumption in sensor design, with all configurations operating at 0.232 mW, and sets a new benchmark for future glucose monitoring technologies. Finally, the study illustrated a clinical investigation to verify the selectivity and sensitivity of PANI towards various molar concentrations of glucose.
- 20 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (13) , 24473-24484
Experimentally Driven Numerical Model of Carbon/Polyaniline-Based Glucose Monitoring Sensors: An Evaluation Using a New Figure of Merit
This study presents an experimentally driven numerical model for evaluating carbon/polyaniline (PANI)-based glucose monitoring sensors, focusing on innovative configurations using graphene-PANI and carbon nanotube (CNT)-PANI composites. We performed a thorough analysis of the morphological, electrophysical, and electrical properties of these materials, ultimately leading to the extraction of key electrical parameters for integration into a finite element model (FEM). This model simulates the entire sensor, enabling the estimation of critical performance metrics such as sensitivity, limit of detection (LOD), linearity, and power consumption. Our findings demonstrate that the CNT-PANI configuration significantly outperforms the laser induced graphene (LIG)-PANI electrode, achieving a figure of merit (FOM) of 0.99 compared to 0.62, thanks to its superior electrical conductivity and high surface area, which facilitates enhanced charge transfer and electrochemical reactions. The optimized sensor configurations reveal optimal parameters for LIG-PANI and CNT-PANI, underscoring the trade-offs between conductivity and overall sensor performance. Notably, the CNT-PANI composite exhibits the highest sensitivity of 2778 μA mM-1 cm-2 and the lowest LOD of 0.09 μM, making it a promising candidate for glucose detection in clinical applications. This work highlights the importance of power consumption in sensor design, with all configurations operating at 0.232 mW, and sets a new benchmark for future glucose monitoring technologies. Finally, the study illustrated a clinical investigation to verify the selectivity and sensitivity of PANI towards various molar concentrations of glucose.
- 8 October 2024
- Published by Springer Nature in Optical and Quantum Electronics
- Vol. 56 (10) , 1-16
Unveiling the indoor performance of perovskite/silicon tan-dem solar cells: a comprehensive exploration through numerically modelled energy band diagrams
- 8 October 2024
- Published by Springer Nature in Optical and Quantum Electronics
- Vol. 56 (10) , 1-16
Unveiling the indoor performance of perovskite/silicon tan-dem solar cells: a comprehensive exploration through numerically modelled energy band diagrams
- 12 February 2022
- Published by SPIE-Intl Soc Optical Eng in Journal of Photonics for Energy
- Vol. 12 (02) , 022202-11
Investigating the variation in the optical properties of TiO2 thin-film utilized in bifacial solar cells using machine learning algorithm
Among various solar cell architectures, dye-sensitized solar cells (DSSCs) and perovskite solar cells have demonstrated the capability of being bifacial as both can be fabricated on conducting glass electrodes. In both cells, TiO2 plays a key role in the optoelectronic properties of the cell. Various studies have reported a range of recipes and deposition techniques for TiO2 thin films. Such variety introduces some uncertainties into the optical properties of the prepared films as well as in the process repeatability. Here, we utilized machine learning methods to correlate the film porosity to the film refractive index, making it capable of studying the impact of varying the fabrication and deposition techniques. Image postprocessing for scanning electron microscope measurements was utilized to estimate the film porosity, and the refractive index was calculated from the T–λ spectra. Four sets of samples with complete bifacial DSSCs were fabricated and characterized. They recorded a maximum current of 23.42 mA. They were fabricated using carboxymethyl cellulose-based suspension and deposited via the spin-coating sol-gel method. The fabricated cells showed an overall conversion efficiency of 7.9% under optical injection of the AM1.5G spectrum from the front side and LED indoor lighting from the counter electrode.
- 12 February 2022
- Published by SPIE-Intl Soc Optical Eng in Journal of Photonics for Energy
- Vol. 12 (02) , 022202-11
Investigating the variation in the optical properties of TiO2 thin-film utilized in bifacial solar cells using machine learning algorithm
Among various solar cell architectures, dye-sensitized solar cells (DSSCs) and perovskite solar cells have demonstrated the capability of being bifacial as both can be fabricated on conducting glass electrodes. In both cells, TiO2 plays a key role in the optoelectronic properties of the cell. Various studies have reported a range of recipes and deposition techniques for TiO2 thin films. Such variety introduces some uncertainties into the optical properties of the prepared films as well as in the process repeatability. Here, we utilized machine learning methods to correlate the film porosity to the film refractive index, making it capable of studying the impact of varying the fabrication and deposition techniques. Image postprocessing for scanning electron microscope measurements was utilized to estimate the film porosity, and the refractive index was calculated from the T–λ spectra. Four sets of samples with complete bifacial DSSCs were fabricated and characterized. They recorded a maximum current of 23.42 mA. They were fabricated using carboxymethyl cellulose-based suspension and deposited via the spin-coating sol-gel method. The fabricated cells showed an overall conversion efficiency of 7.9% under optical injection of the AM1.5G spectrum from the front side and LED indoor lighting from the counter electrode.
- 1 October 2021
- Published by Elsevier in Electrochimica Acta
- Vol. 394
Gum Arabic-capped silver nanoparticles for electrochemical amplification sensing of methylene blue in river water
- 1 October 2021
- Published by Elsevier in Electrochimica Acta
- Vol. 394
Gum Arabic-capped silver nanoparticles for electrochemical amplification sensing of methylene blue in river water
- Open Access
- 14 October 2020
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 10 (62) , 37675-37682
Mucilage-capped silver nanoparticles for glucose electrochemical sensing and fuel cell applications
A simple, cost-effective and green mucilage-capped silver nanoparticles (Mucilage-AgNPs) modified glassy carbon electrode (GC) composite was constructed for efficient and facile electrochemical oxidation of glucose for the first time. Mucilage-AgNPs were synthesized through the direct chemical reduction of Ag+ by mucilage extracted from Opuntia ficus-indica. Mucilage-AgNPs were identified and characterized using ultraviolet-visible spectroscopy, transmission electron microscopy and square wave voltammetry. Modification of the GC with AgNPs was carried out via a transfer-sticking technique with an immobilization time of 1 h. The Mucilage-AgNPs/GC composite was studied as a possible anode for glucose oxidation in a biofuel cell. The composite resulted in glucose oxidation with a current density and power density of 85.7 μA cm−2 and 25.7 μW cm−2, respectively. Glucose sensing using the Mucilage-AgNPs/GC composite was achieved successfully via two pathways: glucose oxidation and AgNP inhibition. The glucose oxidation-based sensor showed a lower detection limit of 0.01 mM and a linear range of 0.01 to 2.2 mM. The AgNPs inhibition-based sensor provides an indirect determination pathway of glucose with a detection limit of 0.1 mM and a linear range of 0.1 to 1.9 mM. AgNP inhibition is a novel pathway that could be used for determining a large number of organic and inorganic molecules. Overall, the Mucilage-AgNPs/GC is considered a pioneering composite for glucose sensing and fuel cell applications.
- 14 October 2020
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 10 (62) , 37675-37682
Open AccessMucilage-capped silver nanoparticles for glucose electrochemical sensing and fuel cell applications
A simple, cost-effective and green mucilage-capped silver nanoparticles (Mucilage-AgNPs) modified glassy carbon electrode (GC) composite was constructed for efficient and facile electrochemical oxidation of glucose for the first time. Mucilage-AgNPs were synthesized through the direct chemical reduction of Ag+ by mucilage extracted from Opuntia ficus-indica. Mucilage-AgNPs were identified and characterized using ultraviolet-visible spectroscopy, transmission electron microscopy and square wave voltammetry. Modification of the GC with AgNPs was carried out via a transfer-sticking technique with an immobilization time of 1 h. The Mucilage-AgNPs/GC composite was studied as a possible anode for glucose oxidation in a biofuel cell. The composite resulted in glucose oxidation with a current density and power density of 85.7 μA cm−2 and 25.7 μW cm−2, respectively. Glucose sensing using the Mucilage-AgNPs/GC composite was achieved successfully via two pathways: glucose oxidation and AgNP inhibition. The glucose oxidation-based sensor showed a lower detection limit of 0.01 mM and a linear range of 0.01 to 2.2 mM. The AgNPs inhibition-based sensor provides an indirect determination pathway of glucose with a detection limit of 0.1 mM and a linear range of 0.1 to 1.9 mM. AgNP inhibition is a novel pathway that could be used for determining a large number of organic and inorganic molecules. Overall, the Mucilage-AgNPs/GC is considered a pioneering composite for glucose sensing and fuel cell applications.
- 22 July 2020
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 5 (30) , 18950-18957
Individual and Simultaneous Voltammetric Determination of Ultra-Trace Environmental Contaminant Dihydroxybenzene Isomers Based on a Composite Electrode Sandwich-like Structure
An advanced electroanalytical technique for the simultaneous assessment of environmental contaminant dihydroxybenzene isomers, catechol (CC), hydroquinone (HQ), and resorcinol (RC), has been investigated using palladium nanoparticles (PdNPs) incorporated onto a poly(1,5-diaminonaphthalene) (DAN) matrix over a glassy carbon electrode (GCE). Concurrently, these types of phenols can be assessed by the PdDAN/GCE modified electrode employing square wave voltammetry and cyclic voltammetry (CV) techniques under optimal conditions. This modified electrode has demonstrated linear responses for CC, HQ, and RC from 50.0 to 1000.0 mM; concomitantly, low detection limits of 0.22, 0.22, and 0.47 nM and low quantification limits of 0.740, 0.758, and 1.590 nM, have been, respectively, shown. Successfully, the simultaneous assessment of the three isomers in river stream water, tap water, and underground water has been implemented via the modified electrode under investigation. In comparison to reported studies, the PdDAN catalytic electrode has shown an effective sensitivity, leverage reproducibility, long-term stability, and excellent anti-interference capability for the determination of dihydroxybenzene isomers.
- 22 July 2020
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 5 (30) , 18950-18957
Individual and Simultaneous Voltammetric Determination of Ultra-Trace Environmental Contaminant Dihydroxybenzene Isomers Based on a Composite Electrode Sandwich-like Structure
An advanced electroanalytical technique for the simultaneous assessment of environmental contaminant dihydroxybenzene isomers, catechol (CC), hydroquinone (HQ), and resorcinol (RC), has been investigated using palladium nanoparticles (PdNPs) incorporated onto a poly(1,5-diaminonaphthalene) (DAN) matrix over a glassy carbon electrode (GCE). Concurrently, these types of phenols can be assessed by the PdDAN/GCE modified electrode employing square wave voltammetry and cyclic voltammetry (CV) techniques under optimal conditions. This modified electrode has demonstrated linear responses for CC, HQ, and RC from 50.0 to 1000.0 mM; concomitantly, low detection limits of 0.22, 0.22, and 0.47 nM and low quantification limits of 0.740, 0.758, and 1.590 nM, have been, respectively, shown. Successfully, the simultaneous assessment of the three isomers in river stream water, tap water, and underground water has been implemented via the modified electrode under investigation. In comparison to reported studies, the PdDAN catalytic electrode has shown an effective sensitivity, leverage reproducibility, long-term stability, and excellent anti-interference capability for the determination of dihydroxybenzene isomers.
- 24 March 2020
- Published by American Chemical Society (ACS) in ACS Applied Nano Materials
- Vol. 3 (4) , 3868-3875
Dissolved Organic Matter-Capped Silver Nanoparticles for Electrochemical Aggregation Sensing of Atrazine in Aqueous Systems
- 24 March 2020
- Published by American Chemical Society (ACS) in ACS Applied Nano Materials
- Vol. 3 (4) , 3868-3875
Dissolved Organic Matter-Capped Silver Nanoparticles for Electrochemical Aggregation Sensing of Atrazine in Aqueous Systems