Kazuki Hashimoto
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Kazuki Hashimoto has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Daisuke Yamazaki
Department of Neurosurgery, Shinshu University School of Medicine, 3-1-1 Asahi, Matsumoto 390-8621, Japan
1 shared publication - Hidetoshi Onodera
Graduate School of Informatics, Kyoto University, Kyoto, Japan
1 shared publication - Hiroshi Nomura
Department of Biomolecular Sciences, Field of Omics Health Sciences, Nagoya University Graduate School of Medicine, Nagoya, 1-1-20 Daiko-minami, Higashi-ku, 461-8673, Japan
1 shared publication M. Horinakal
Fujitsu Labs. Ltd., Kawasaki, Japan
1 shared publication- Takafumi Okuda
Department of Electrical Engineering Kyoto University Kyoto Japan
1 shared publication - Takamichi Nakamoto
Institute of Integrated Research, Institute of Science Tokyo, Yokohama, Japan
1 shared publication
Latest Publications
- 1 April 2020
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 91 (4) , 044703
Measurement of internal magnetic flux density distribution in air-core toroidal transformer under high-frequency excitation
An investigation of air-core toroidal transformers has been undertaken to enable power converters to achieve megahertz operation. The characteristics of the air-core toroidal transformer govern the behaviors of the internal magnetic flux of the transformer. Understanding the behaviors at an above-megahertz level is a key issue in the design of the air-core toroidal transformer. This paper discusses the internal magnetic flux density distribution in the air-core toroidal transformer under high-frequency excitation. We propose a measurement method for the distribution and show the obtained results under a sinusoidal excitation with an amplitude of 1.5 A and a frequency of 1 MHz. The results reveal a non-uniform distribution in the tangential and normal directions. The cause of this non-uniformity was found to be the structure of the air-core toroidal transformer. In addition, the validity of the proposed measurement method was confirmed by comparing the experimentally obtained results with a numerical estimation using the Biot–Savart law. These results suggest that the proposed measurement method is capable of investigating the distributed characteristics of air-core toroidal transformers under megahertz excitation.
- 1 April 2020
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 91 (4) , 044703
Measurement of internal magnetic flux density distribution in air-core toroidal transformer under high-frequency excitation
An investigation of air-core toroidal transformers has been undertaken to enable power converters to achieve megahertz operation. The characteristics of the air-core toroidal transformer govern the behaviors of the internal magnetic flux of the transformer. Understanding the behaviors at an above-megahertz level is a key issue in the design of the air-core toroidal transformer. This paper discusses the internal magnetic flux density distribution in the air-core toroidal transformer under high-frequency excitation. We propose a measurement method for the distribution and show the obtained results under a sinusoidal excitation with an amplitude of 1.5 A and a frequency of 1 MHz. The results reveal a non-uniform distribution in the tangential and normal directions. The cause of this non-uniformity was found to be the structure of the air-core toroidal transformer. In addition, the validity of the proposed measurement method was confirmed by comparing the experimentally obtained results with a numerical estimation using the Biot–Savart law. These results suggest that the proposed measurement method is capable of investigating the distributed characteristics of air-core toroidal transformers under megahertz excitation.
- 1 March 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 179-180
Olfactory display using surface acoustic wave device and micropumps for wearable applications
Olfaction is expected to provide reality and a sense of immersion in multimedia contents. Therefore, an olfactory display, a gadget to present scents to one or more user(s), has been developed. A wearable olfactory display has advantage from the viewpoint of reducing the odorant diffusion into the atmosphere and is suitable for virtual reality applications. In this study, we developed a portable olfactory display using surface acoustic wave (SAW) device and micropumps. In the experiment using quartz crystal microbalance (QCM) gas sensor, we confirmed that the olfactory display can present the odorant with intended intensity.
- 1 March 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 179-180
Olfactory display using surface acoustic wave device and micropumps for wearable applications
Olfaction is expected to provide reality and a sense of immersion in multimedia contents. Therefore, an olfactory display, a gadget to present scents to one or more user(s), has been developed. A wearable olfactory display has advantage from the viewpoint of reducing the odorant diffusion into the atmosphere and is suitable for virtual reality applications. In this study, we developed a portable olfactory display using surface acoustic wave (SAW) device and micropumps. In the experiment using quartz crystal microbalance (QCM) gas sensor, we confirmed that the olfactory display can present the odorant with intended intensity.
- 28 September 2004
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 240-525
A 25GHz clock buffer and a 50Gb/s 2:1 selector in 90nm CMOS
- 28 September 2004
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 240-525
A 25GHz clock buffer and a 50Gb/s 2:1 selector in 90nm CMOS