Anam Chandra Sekar
Anam Chandra Sekar has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Ashwini Thandu
Department of Prosthodontics and Crown & Bridge, SVS Institute of Dental Sciences, Mahabubnagar, IND
1 shared publication - Bhukya P. Nayak
SVS Institute of Dental Sciences, Mahabubnagar, Kaloji Narayana Rao University of Health Sciences, Telangana 509001, India
1 shared publication - Elad Yakobson
Magdent Ltd., Bnei-Brak 5120109, Israel
1 shared publication - Jamil Awad Shibli
Dental Research Division, Department of Periodontology and Oral Implantology, University of Guarulhos (UNG), Guarulhos 07023-070, Brazil
1 shared publication Kunchala Sailasri
Department of Prosthodontics and Crown & Bridge, SVS Institute of Dental Sciences, Mahabubnagar, IND
1 shared publication- Oleg Dolkart
Division of Orthopaedic Surgery, Tel Aviv Sourasky Medical Center, Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel
1 shared publication
Latest Publications
- Open Access
- 29 April 2022
- Published by Springer Nature in Cureus
- Vol. 14 (4) , e24591
Biomechanical Evaluation of Stress Distribution in Equicrestal and Sub-crestally Placed, Platform-Switched Morse Taper Dental Implants in D3 Bone: Finite Element Analysis
The aim of the study was to assess the effect of implant placement depth on stress distribution in bone around a platform-switched and Morse taper dental implants placed at the equi-crestal and 1 mm and 2 mm sub-crestal levels in a D3 bone using the 3D finite element analysis. A mechanical model of a partially edentulous maxilla was generated from a computerized tomography (CT) scan of an edentulous patient, as it can give exact bony contours of cortical bone. Also, from accurate geometric measurements obtained from the manufacturer, 3D models of Morse taper and platform-switched implants were manually drawn. The implant and bone models were then superimposed to simulate implant insertion in bone. Three implant positioning levels such as the equi-crestal, 1 mm sub-crestal, and 2 mm sub-crestal models were created, and meshing was done to create the number of elements for distribution of applying loads. The elastic properties of cortical bone and implant, such as Young's modulus and Poisson's ratio (µ), were determined. A load (axial and oblique) of 200N that simulated masticatory force was applied. On comparing stresses within the bone around the equi-crestal and 1 mm and 2 mm sub-crestal implants, it was observed that the maximum stresses were seen within cortical bone around the equi-crestally placed implant (21.694), the least in the 2 mm sub-crestally placed implant (18.85), and intermediate stresses were seen within the 1 mm sub-crestally placed implant (18.876). Sub-crestal (1-2mm) placement of a Morse taper and a platform-switched implant is recommended for long-term success, as maximum von Mises stresses were found within cortical bone around the equi-crestal implant followed by the 1 mm sub-crestal implant and then the 2 mm sub-crestal implant.
- 29 April 2022
- Published by Springer Nature in Cureus
- Vol. 14 (4) , e24591
Open AccessBiomechanical Evaluation of Stress Distribution in Equicrestal and Sub-crestally Placed, Platform-Switched Morse Taper Dental Implants in D3 Bone: Finite Element Analysis
The aim of the study was to assess the effect of implant placement depth on stress distribution in bone around a platform-switched and Morse taper dental implants placed at the equi-crestal and 1 mm and 2 mm sub-crestal levels in a D3 bone using the 3D finite element analysis. A mechanical model of a partially edentulous maxilla was generated from a computerized tomography (CT) scan of an edentulous patient, as it can give exact bony contours of cortical bone. Also, from accurate geometric measurements obtained from the manufacturer, 3D models of Morse taper and platform-switched implants were manually drawn. The implant and bone models were then superimposed to simulate implant insertion in bone. Three implant positioning levels such as the equi-crestal, 1 mm sub-crestal, and 2 mm sub-crestal models were created, and meshing was done to create the number of elements for distribution of applying loads. The elastic properties of cortical bone and implant, such as Young's modulus and Poisson's ratio (µ), were determined. A load (axial and oblique) of 200N that simulated masticatory force was applied. On comparing stresses within the bone around the equi-crestal and 1 mm and 2 mm sub-crestal implants, it was observed that the maximum stresses were seen within cortical bone around the equi-crestally placed implant (21.694), the least in the 2 mm sub-crestally placed implant (18.85), and intermediate stresses were seen within the 1 mm sub-crestally placed implant (18.876). Sub-crestal (1-2mm) placement of a Morse taper and a platform-switched implant is recommended for long-term success, as maximum von Mises stresses were found within cortical bone around the equi-crestal implant followed by the 1 mm sub-crestal implant and then the 2 mm sub-crestal implant.
- Open Access
Effect of the Pulsed Electromagnetic Field (PEMF) on Dental Implants Stability: A Randomized Controlled Clinical Trial
A pulsed electromagnetic field (PEMF) has been shown to contribute to heightening bone regeneration in a range of clinical areas, including dentistry. Due to the scarcity of studies using PEMF in oral implantology, the present experiment scrutinized the effect of PEMF can lead to improving the stability of the implant. A total of 19 subjects (40 implants in total) were selected to participate in the current study and were randomly allocated to either the PEMF group or control group. Subjects in the PEMF group received an activated miniaturized electromagnetic device (MED) while the control group received a sham healing cup. Implants stability was assessed by resonance frequency analyses (RFA) via implant stability quotient (ISQ) calculations. RFA were recorded as following: immediately after procedure, and then 2, 4, 6, 8 and 12 weeks later. Radiographic analysis was performed at baseline, 6 and 12 weeks after implant placement. Proinflammatory cytokines were evaluated in peri-implant crevicular fluid (PICF). The PEMF group presented higher ISQ mean values when compared to the control group. The primary stability time frame (the first 2 weeks) MED group depicted an increase in stability of 6.8%, compared to a decrease of 7.6% in the control group related to the baseline. An overall stability increase of 13% was found in MED treated group (p = 0.02), in contrast, the overall stability in the control group decreased by 2% (p = 0.008). TNF-α concentration during first 4 weeks was lower in the MED treated group. The data strongly suggests that MED generated continuing a PEMF may be considered as a new way to stimulate the stability of the implants at the early healing period.
Open AccessEffect of the Pulsed Electromagnetic Field (PEMF) on Dental Implants Stability: A Randomized Controlled Clinical Trial
A pulsed electromagnetic field (PEMF) has been shown to contribute to heightening bone regeneration in a range of clinical areas, including dentistry. Due to the scarcity of studies using PEMF in oral implantology, the present experiment scrutinized the effect of PEMF can lead to improving the stability of the implant. A total of 19 subjects (40 implants in total) were selected to participate in the current study and were randomly allocated to either the PEMF group or control group. Subjects in the PEMF group received an activated miniaturized electromagnetic device (MED) while the control group received a sham healing cup. Implants stability was assessed by resonance frequency analyses (RFA) via implant stability quotient (ISQ) calculations. RFA were recorded as following: immediately after procedure, and then 2, 4, 6, 8 and 12 weeks later. Radiographic analysis was performed at baseline, 6 and 12 weeks after implant placement. Proinflammatory cytokines were evaluated in peri-implant crevicular fluid (PICF). The PEMF group presented higher ISQ mean values when compared to the control group. The primary stability time frame (the first 2 weeks) MED group depicted an increase in stability of 6.8%, compared to a decrease of 7.6% in the control group related to the baseline. An overall stability increase of 13% was found in MED treated group (p = 0.02), in contrast, the overall stability in the control group decreased by 2% (p = 0.008). TNF-α concentration during first 4 weeks was lower in the MED treated group. The data strongly suggests that MED generated continuing a PEMF may be considered as a new way to stimulate the stability of the implants at the early healing period.