Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Boris Kostov has a total of 20 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Hydrodynamic Impact of Expeller Vanes on Single Stage Centrifugal Pump Performance: A CFD Approach

    by Kliment Klimentov, Gencho Popov, Boris Kostov, Salaf Ibrahim

    The study evaluates the influence of expeller vanes on the hydrodynamics of a centrifugal pump and on the generated axial and radial forces. Four geometric impeller variants with different con-figurations and numbers of expeller vanes were analyzed. The results show that the addition of expeller vanes significantly modifies the unsteady hydrodynamic structures and leads to substantial changes in force amplitudes. Geometry G1 exhibits the most unfavorable radial load behavior, whereas geometry G3 provides the most balanced hydraulic and mechanical performance. Modifi-cation G4 improves the radial force but increases axial force fluctuations due to the larger number of rear expeller vanes. In conclusion, configuration G3 is identified as the optimal design, offering the best compromise between hydraulic efficiency, load stability, and mechanical reliability.

  • Open Access

    Slip Risk on Surfaces Made with 3D Printing Technology

    by Bartosz Wieczorek, Łukasz Gierz, Łukasz Warguła, Grzegorz Kinal, Boris Kostov, Konrd Jan Waluś

    Slip risk on surfaces used by humans or active in mechanisms is studied to mitigate its effects or harness its beneficial outcomes. This article presents pioneering research on the risk of surfaces created using 3D printing technology. The study examines three materials (Polylactic Acid, PLA; Polyethylene Terephthalate Glycol, PET-G; and Thermoplastic Polyurethane, TPU), considering three print head movement directions relative to the British Portable Skid Resistance Tester (BSRT) measurement direction. In addition, surface roughness tests were performed. Dry tests showed that the structure created by the printing direction perpendicular to the movement direction is the safest in terms of slip risk. The SRVs of the measured samples on a qualitative scale were classified on this scale as materials with low or extremely low slip risk (ranging from 55 to 90 SRV dry and 35 to 60 SRV wet). Referring to the influence of the type of material on the SRV, it was found that the safest material in terms of reducing the risk of slipping in dry conditions is TPU and, in wet conditions, PLA. During wet tests, the best properties that reduce the risk of slippage in most cases are shown by the printing direction on a horizontal plane at an angle of 45° to the direction of movement. Statistical analysis showed that the printing direction and roughness do not have a statistically significant effect on the SRV, but the type of material and the type of method (dry and wet) and their interaction have a significant effect.


  • Open Access

    Studying the Impact of Diffuser Return Guide Vanes on the Energy Performance of a Multistage Centrifugal Pump

    by Jan Górecki, Kliment Klimentov, Gencho Popov, Boris Kostov, Salaf Ibrahim

    The head, efficiency, and cavitation characteristics of centrifugal pumps are highly dependent on the velocity field in front of the impeller inlet. In multistage pumps, the velocity field in front of the second and each subsequent stage is determined by the shape (design) of the diffuser return guide vanes. This current work presents the results obtained by performing a numerical study using ANSYS CFX 14.0 to determine the impact of the shape (design) of diffuser return guide vanes on the head and coefficient of efficiency of one stage of a multistage centrifugal pump. Three RGVs with different Outlet angles are studied: α6—original RGV with α6=90 deg, RGV1 with α6=110 deg and RGV2 with α6=128 deg. The results obtained after performing CFD modeling indicate that with one of the studied RGVs, the pump stage head increases by nearly 20%, while the hydraulic coefficient of efficiency remains almost constant. Applying entropy production theory is used to determine the impact of the various components of entropy production on the total head loss in the studied pump stage. The impact of the Outlet angle of the RGV on the velocity field of the flow in front of the next impeller (stage) as well as the RGV head is also analyzed. The numerical results of the original RGV are compared with the experimental data obtained from large-scale studies of pumps performed at the Laboratory of Hydraulic Machines of the University “Angel Kanchev” of Ruse, Bulgaria. When using the modified RGVs, the head curve of the original pump can be obtained by operating at a lower speed or with a smaller impeller diameter. This may lead to an overall increase in the energy efficiency of the machine, which could be explored as a future task.


  • Open Access

    Identification of the Problem in Controlling the Air–Fuel Mixture Ratio (Lambda Coefficient λ) in Small Spark-Ignition Engines for Positive Pressure Ventilators

    by Łukasz Warguła, Piotr Kaczmarzyk, Bartosz Wieczorek, Łukasz Gierz, Daniel Małozięć, Tomasz Góral, Boris Kostov, Grigor Stambolov

    The air–fuel ratio is a crucial parameter in internal combustion engines that affects optimal engine performance, emissions, fuel efficiency, engine durability, power, and efficiency. Positive pressure ventilators (PPVs) create specific operating conditions for drive units, characterized by a reduced ambient pressure compared to standard atmospheric pressure, which is used to control carburetor-based fuel supply systems. The impact of these conditions was investigated for four commonly used PPVs (with internal combustion engines) in fire services across the European Union (EU), using a lambda (λ), carbon dioxide (CO2), carbon monoxide (CO), and hydrogen carbon (HC) analyser for exhaust gases. All four ventilators were found to operate with lean and very lean mixtures, with their lambda coefficients ranging from 1.6 to 2.2. The conducted tests of the CO2, CO, and HC concentrations in the exhaust gases of all four fans show dependencies consistent with theoretical analyses of the impact of the fuel–air mixture on emissions. It can be observed that as the amount of burned air decreases, the values of CO and HC decrease, while the concentration of CO2 increases with the increase in engine load. Such an operation can accelerate engine wear, increase the emission of harmful exhaust gases, and reduce the effective performance of the device. This condition is attributed to an inadequate design process, where drive units are typically designed to operate within atmospheric pressure conditions, as is common for these engines. However, when operating with a PPV, the fan’s rotor induces significant air movement, leading to a reduction in ambient pressure on the intake side where the engine is located, thereby disrupting its proper operation.


  • Open Access

    Analysis of Density Distribution in a Cylindrical Specimen under Compaction Using the Example of Dry Ice

    by Jan Górecki, Maciej Berdychowski, Krzysztof Wałęsa, Boris Kostov

    When dealing with processes involving the compaction of bulk materials, very often the quality of the product is determined based on density measurements. Methods used in the industry do not produce compacted materials with high degrees of homogeneity. As a result, the quality of the resulting product, interpreted as its density, varies over the cross-section of the product. In this article, the authors present the results of a numerical study involving the analysis of the density distribution of compacted dry ice during the reciprocating process. The Drucker–Prager/cap model was used in this study, which allowed the change in mechanical properties of the compacted material to be taken into account during the simulation of the process. The diameter, height and density of the cylindrical specimens used in the numerical tests were taken as the variable parameters. Thus, as a result of the testing, the authors could formulate conclusions relating to their impact on the homogeneity of the material.

  • Open Access

    Research on the Distribution of Axial Excitation of Positive Pressure Ventilators in the Aspect of Stability Safety of the Load-Bearing Frame

    by Bartosz Wieczorek, Piotr Kaczmarzyk, Łukasz Warguła, Marcin Giedrowicz, Damian Bąk, Łukasz Gierz, Grigor Stambolov, Boris Kostov

    Positive pressure ventilators are exposed to self-shifting during their operation. The aim of the article was to perform research analysing dynamic excitations resulting from vibrations caused by the operation of the drive system. The tests included four different fans, including one with an...


  • Open Access

    Applying Criteria Equations in Studying the Energy Efficiency of Pump Systems

    by Gencho Popov, Stanislaw Legutko, Kliment Klimentov, Boris Kostov

    This paper presents a method for evaluating the energy efficiency of pump systems used to transport fluids .It is mainly scientifically applied and engineering-applied in nature and aims to propose a new approach (method) to researchers in their study of the energy efficiency of such systems. By applying the well-known scientific method of Dimensional Analysis (Buckingham π-theorem), dimensionless complexes (π-criterions and their relevant equations, which are original (innovative) and are offered for the first time in the scientific literature), used in accomplishing an energy assessment and analysis of such systems, are obtained. The criterion ∏1 = ev/ρgD represents specific energy consumption in kWh/m3 for a given pipe system with an exemplary diameter D. The criterion ∏2 = Q/[n(Hp − Hst)D2] represents a generalized parameter which is characterized by the selected method of flow rate (Q) regulation for a pump system with given static head Hst—by changing the speed of rotation (VFD, Variable Frequency Drive), by throttling, leading to an increase of the system hydraulic losses hv = (HpHst) or by diverting a part of the flow, known as “by-pass”, where the pump operates with the required system head Hp, but ensures higher flow rates, i.e., Qp > Qs. The flow rate criterion ∏3 = Q/(νD) characterizes the flow rate for a pipe system with an exemplary diameter D, used to transport a liquid with known viscosity ν. An example for applying these dimensionless complexes in accomplishing a quantitative evaluation of the energy efficiency of a given pump system is presented. A method for determining the main parameters forming these criterions, used to describe the different methods of flow rate regulation, has been developed. To demonstrate the application of this method, newly proposed by the authors, including obtaining the relevant criteria equations of the type ∏1 = f(∏2, ∏3), a certain pump system was used. This original approach for studying pump systems used to transport fluids can be used both to accomplish an energy analysis of such systems as well as to solve for optimization or other engineering problems.


  • Open Access

    Analyzing the Energy Efficiency of Fan Systems by Using the Dimensional Analysis (DA) Method

    by Gencho Popov, Kliment Klimentov, Boris Kostov, Reneta Dimitrova

    This work represents a method for investigating the energy efficiency of fan systems used to transport fluids. Applying the methods of dimensional analysis (DA) enables establishing five dimensionless complexes ( π criteria), including some basic parameters having impacts on the consumed energy used for the transportation of a unit quantity of air. The proposed criterion π 1 includes the specific energy consumption e v (specific fan power SFP), and is used for the quantitative evaluation of the energy effectiveness of the fluid transportation. This criterion also includes the main geometric size of the pipe system (network) and the gas properties. The criterion π 3 indicates the impact of the applied method of flow rate regulation on the effective energy use of fan systems. This criterion includes parameters characterizing the selected method of flow rate regulation: speed ( n ) for using the frequency method and the referred length ( L T P ) of the pipe system for using the throttle method. The established (proposed) dimensionless parameters are used to study a concrete fan system. The obtained results concerning the evaluation of the impact of the two most used methods of flow rate regulation (frequency and throttle), as well as the density variation as a result of the temperature change, on the effective energy use are graphically presented: π 1 = f ( π 3 ) .