Mika Alanen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Mika Alanen has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Mikko Malaska
Tampere University, Tampere, Finland
5 shared publications - Kristo Mela
Tampere University Finland
2 shared publications - Mikko Salminen
Jensen Hughes, Tampere, Finland
2 shared publications - Sami Pajunen
Faculty of Built Environment Tampere University Tampere Finland
2 shared publications - František Wald
Department of Steel and Timber Structures, Faculty of Civil Engineering, Czech Technical University in Prague, Thákurova 7, 166 29 Prague 6, Czech Republic
1 shared publication - Hüseyin Emre Ilgın
Tampere University
1 shared publication
Latest Publications
- Open Access
- 22 April 2024
- Published by Elsevier in Fire Safety Journal
- Vol. 146
Experimental determination of the charring rate of cross-laminated timber panels
- 22 April 2024
- Published by Elsevier in Fire Safety Journal
- Vol. 146
Open AccessExperimental determination of the charring rate of cross-laminated timber panels
- Open Access
Evaluating Fire Performance: An Experimental Comparison of Dovetail Massive Wooden Board Elements and Cross-Laminated Timber
The use of adhesives and metal connectors is vital in engineered wood product (EWP) composition. However, the utilization of adhesives poses sustainability and recyclability challenges due to the emission of toxic gases. Similarly, metal fasteners negatively impact the disposal, reusability, and recyclability of EWPs. An alternative solution that exclusively employs pure wood, known as dovetail massive wooden board elements (DMWBEs), eliminates the need for adhesives and metal fasteners. This paper presents an experimental comparative assessment of the fire/charring performance of DMWBEs and cross-laminated timber (CLT). Model-scale test specimens measuring 200 mm in thickness, 950 mm in width, and 950 mm in length were vertically tested according to EN 1363-1. The charring behavior of DMWBEs closely resembled that of solid timber, with only a slight increase in the charring rate. Charring primarily occurred in the third lamella layer out of five, with no observable flames or hot gases on the unexposed side. The dovetail detail effectively prevented char fall-off with the tested lamella thickness. CLT specimens exhibited a notable rise in the charring rate due to the fall-off of the first lamellae layer.
Open AccessEvaluating Fire Performance: An Experimental Comparison of Dovetail Massive Wooden Board Elements and Cross-Laminated Timber
The use of adhesives and metal connectors is vital in engineered wood product (EWP) composition. However, the utilization of adhesives poses sustainability and recyclability challenges due to the emission of toxic gases. Similarly, metal fasteners negatively impact the disposal, reusability, and recyclability of EWPs. An alternative solution that exclusively employs pure wood, known as dovetail massive wooden board elements (DMWBEs), eliminates the need for adhesives and metal fasteners. This paper presents an experimental comparative assessment of the fire/charring performance of DMWBEs and cross-laminated timber (CLT). Model-scale test specimens measuring 200 mm in thickness, 950 mm in width, and 950 mm in length were vertically tested according to EN 1363-1. The charring behavior of DMWBEs closely resembled that of solid timber, with only a slight increase in the charring rate. Charring primarily occurred in the third lamella layer out of five, with no observable flames or hot gases on the unexposed side. The dovetail detail effectively prevented char fall-off with the tested lamella thickness. CLT specimens exhibited a notable rise in the charring rate due to the fall-off of the first lamellae layer.
- Open Access
- 3 August 2023
- Published by Springer Nature in Fire Technology
- Vol. 60 (4) , 2581-2600
Fire Performance of Steel-Timber Hybrid Beam Section
Slim-floor-type of steel-timber hybrid floor systems which use steel beams contained within the depth of the cross-laminated timber (CLT) floor slab offer many benefits, but there is still very little research available on the fire resistance performance of these systems. In the study presented in this paper two furnace tests and numerical simulations have been conducted to investigate the thermal profiles of the steel member and CLT slabs and to obtain information on the temperature development and charring of the hybrid beam section when it is exposed to standard fire conditions. Also, the effects of intumescent fire protection on temperatures and charring performance were investigated. Numerical 2D thermal simulations for unprotected and protected cases were conducted using SAFIR software, and the agreement between experiments and numerical-analysis predictions were in general very good. The results show that intumescent protection reduces the temperatures of the steel and CLT components as well as charring depth significantly, and the start of charring at CLT slab support may be delayed if intumescent paint protection thicker than that required for the load bearing steel member is used. The result also showed that CLT temperatures exceed 100°C already in the early stages of the fire which decrease the strength and stiffness properties of CLT much before the start of charring. Therefore, the fire design of the CLT slab support should not only consider the char depth and residual cross-section analysis but also the reduction in strength.
- 3 August 2023
- Published by Springer Nature in Fire Technology
- Vol. 60 (4) , 2581-2600
Open AccessFire Performance of Steel-Timber Hybrid Beam Section
Slim-floor-type of steel-timber hybrid floor systems which use steel beams contained within the depth of the cross-laminated timber (CLT) floor slab offer many benefits, but there is still very little research available on the fire resistance performance of these systems. In the study presented in this paper two furnace tests and numerical simulations have been conducted to investigate the thermal profiles of the steel member and CLT slabs and to obtain information on the temperature development and charring of the hybrid beam section when it is exposed to standard fire conditions. Also, the effects of intumescent fire protection on temperatures and charring performance were investigated. Numerical 2D thermal simulations for unprotected and protected cases were conducted using SAFIR software, and the agreement between experiments and numerical-analysis predictions were in general very good. The results show that intumescent protection reduces the temperatures of the steel and CLT components as well as charring depth significantly, and the start of charring at CLT slab support may be delayed if intumescent paint protection thicker than that required for the load bearing steel member is used. The result also showed that CLT temperatures exceed 100°C already in the early stages of the fire which decrease the strength and stiffness properties of CLT much before the start of charring. Therefore, the fire design of the CLT slab support should not only consider the char depth and residual cross-section analysis but also the reduction in strength.