T. S. Ajmal
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
T. S. Ajmal has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
Shashi Bhushan Arya
2 shared publications- Shashi Bhushan Arya
Corrosion Engineering Lab, Department of Metallurgical and Materials Engineering, National Institute of Technology Karnataka Surathkal, Mangalore, India
2 shared publications Jiyaul Haque
Department of Chemistry, Indian Institute of Technology (Banaras Hindu University), Varanasi, India
1 shared publicationK. Rajendra Udupa
1 shared publicationL. R. Thippeswamy
Department of Mechanical Engineering, National Institute of Technology Karnataka, Mangalore, India
1 shared publicationM. A. Quraishi
Department of Chemistry, Indian Institute of Technology (Banaras Hindu University), Varanasi, India
1 shared publication
Latest Publications
- 5 September 2024
- Published by Wiley in Materials and Corrosion
- Vol. 76 (1) , 175-187
Enhancing the Flow‐Accelerated Corrosion Resistance of X70 API Steel Through Laser Surface Melting in Synthetic Oilfield Water
Hydrodynamic flow conditions play a critical role in piping failure due to sharp variations of the Reynolds number in process and petrochemical industries. The current study aims to enhance flow‐accelerated corrosion (FAC) resistance using metallurgy of the surface by utilizing the laser surface melting (LSM) technique. The FAC behavior of API X70 steel in simulated Indian synthetic oilfield water was studied by utilizing a closed‐loop corrosion apparatus to simulate the pipeline flow. Electrochemical corrosion experiments (AC and DC methods) were conducted at a constant fluid velocity of 3 m/s in untreated and LSM‐treated samples (at 2.5 and 3.0 kW) placed at a 90° pipe elbow. Experimental results showed that LSM‐treated samples displayed enhanced resistance to FAC, attributed to changes in surface metallurgy. Additionally, it was observed that the corrosion rate varied within the pipe elbow for the different samples at different locations.
- 5 September 2024
- Published by Wiley in Materials and Corrosion
- Vol. 76 (1) , 175-187
Enhancing the Flow‐Accelerated Corrosion Resistance of X70 API Steel Through Laser Surface Melting in Synthetic Oilfield Water
Hydrodynamic flow conditions play a critical role in piping failure due to sharp variations of the Reynolds number in process and petrochemical industries. The current study aims to enhance flow‐accelerated corrosion (FAC) resistance using metallurgy of the surface by utilizing the laser surface melting (LSM) technique. The FAC behavior of API X70 steel in simulated Indian synthetic oilfield water was studied by utilizing a closed‐loop corrosion apparatus to simulate the pipeline flow. Electrochemical corrosion experiments (AC and DC methods) were conducted at a constant fluid velocity of 3 m/s in untreated and LSM‐treated samples (at 2.5 and 3.0 kW) placed at a 90° pipe elbow. Experimental results showed that LSM‐treated samples displayed enhanced resistance to FAC, attributed to changes in surface metallurgy. Additionally, it was observed that the corrosion rate varied within the pipe elbow for the different samples at different locations.
- 3 April 2020
- Published by SAGE Publications in Corrosion Engineering, Science and Technology: The International Journal of Corrosion Processes and Corrosion Control
- Vol. 55 (6) , 487-496
Influence of green inhibitor on flow-accelerated corrosion of API X70 line pipe steel in synthetic oilfield water
Inhibition effect of oleic acid hydrazide (OAH), a green corrosion inhibitor on API X70 steel in an Indian oilfield produced water was investigated for the first time under flow condition. The test was carried out at a more critical location (90-degree pipe elbow) in a circulating loop system with the fixed flow velocity. This location is deliberately chosen because, at this location, catastrophic failure of a low alloy steel piping system usually takes place under highly corrosive turbulent flow with higher wall shear stress and flow velocity. The corrosion examination was carried out by varying the concentrations (0.05, 0.15, 0.30 g L−1) of the OAH inhibitor under flow condition. The maximum inhibitor efficiency is found 87.7% at 0.30 g L−1 concentration. The formation of protective film was confirmed by SEM, XPS, Raman spectroscopy and FTIR spectra.
- 3 April 2020
- Published by SAGE Publications in Corrosion Engineering, Science and Technology: The International Journal of Corrosion Processes and Corrosion Control
- Vol. 55 (6) , 487-496
Influence of green inhibitor on flow-accelerated corrosion of API X70 line pipe steel in synthetic oilfield water
Inhibition effect of oleic acid hydrazide (OAH), a green corrosion inhibitor on API X70 steel in an Indian oilfield produced water was investigated for the first time under flow condition. The test was carried out at a more critical location (90-degree pipe elbow) in a circulating loop system with the fixed flow velocity. This location is deliberately chosen because, at this location, catastrophic failure of a low alloy steel piping system usually takes place under highly corrosive turbulent flow with higher wall shear stress and flow velocity. The corrosion examination was carried out by varying the concentrations (0.05, 0.15, 0.30 g L−1) of the OAH inhibitor under flow condition. The maximum inhibitor efficiency is found 87.7% at 0.30 g L−1 concentration. The formation of protective film was confirmed by SEM, XPS, Raman spectroscopy and FTIR spectra.