MSMitsuo Sobajima

Mitsuo Sobajima

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Mitsuo Sobajima has a total of 32 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    IVUS-guided wiring using the deep vein as a landmark (IDEAL) technique for treating chronic total occlusions in peripheral artery disease

    by Yohei Ueno, Mitsuo Sobajima, Teruhiko Imamura, Hiroshi Onoda, Ryuichi Ushijima, Hiroshi Ueno, Koichiro Kinugawa

    Background: Endovascular therapy (EVT) is a well-established revascularization strategy for patients with peripheral artery disease. However, achieving optimal wire crossing in complex chronic total occlusion lesions remains technically challenging. Intravascular ultrasound (IVUS)-guided wiring facilitates safer and more effective procedures. However, aligning IVUS findings with fluoroscopic imaging is challenging due to catheter rotation. We report a novel technique—termed the IDEAL technique—that leverages the deep vein as an anatomical landmark to correct IVUS rotational orientation. Case presentation.: A 76-year-old female presented with chronic limb-threatening ischemia in the right toe. Contrast-enhanced computed tomography revealed a chronic total occlusion in the right superficial femoral artery. EVT was performed via the right common femoral artery. IVUS revealed that the first guidewire had entered the subintimal space partway through its course. Using preprocedural computed tomography, the deep vein was identified and its clock-face position relative to the artery was determined. This anatomical landmark enabled correction of IVUS image rotation, allowing accurate re-direction of a second guidewire under fluoroscopic guidance, thereby successfully crossing into the intraplaque lumen. Conclusions: The IDEAL technique quickly provides anatomical orientation by utilizing the deep vein as a landmark during IVUS-guided wiring—making it, quite literally, ideal.


  • Open Access

    Introduction of novel intravascular ultrasound preceding with angled guiding catheter (I-PAD) technique to treat chronic total occlusions in peripheral artery disease

    by Mitsuo Sobajima, Teruhiko Imamura, Yohei Ueno, Hiroshi Onoda, Ryuichi Ushijima, Hiroshi Ueno, Koichiro Kinugawa

    Background: The optimal endovascular treatment (EVT) for chronic total occlusion (CTO) lesions in patients with peripheral artery disease (PAD) has remained unestablished. We encountered a patient with PAD in whom CTO was successfully treated using a novel technique that involved intravascular ultrasound (IVUS) and angled guiding catheter: IVUS Preceding with Angled guiDing catheter (I-PAD) technique. Case presentation: A 74-year-old male presented with intermittent claudication attributed to CTO of the right external iliac artery. EVT was performed via the right common femoral artery. We retrogradely advanced the I-PAD system (i.e. partially extending the IVUS transducer portion from the tip of the angled guiding catheter) in the CTO lesion under the real-time guidance of IVUS imaging. We successfully traversed the CTO lesion without the use of a guidewire in approximately three minutes. The procedure concluded successfully without any procedure-related complications, following optimal stenting. Conclusions: The I-PAD might be an effective technique to accurately, quickly, and safely pass through CTO lesions.


  • Open Access

    Cardio–Splenic Relationship in Patients Receiving Trans-Catheter Aortic Valve Replacement

    by Teruhiko Imamura, Hayato Fujioka, Ryuichi Ushijima, Mitsuo Sobajima, Nobuyuki Fukuda, Hiroshi Ueno, Koichiro Kinugawa

    Background: The spleen seems to be a significant buffer of the effective circulating blood volume by changing its size dramatically according to hemodynamics. The cardio–splenic relationship has been recently proposed in the literature regarding heart failure cohorts, and the splenic size has been proposed as a prognostic factor in these cohorts. However, the clinical implication of the splenic size in patients receiving trans-catheter aortic valve replacement (TAVR) remains unknown. Methods: Patients who underwent TAVR at our institute between 2015 and 2022 were eligible. Of these, the patients whose abdominal computed tomography imaging was obtained before TAVR were included. The volume of the spleen was measured in all the participants. The prognostic impact of the indexed splenic volume (SVI) on the 2-year cardiac death or heart failure readmissions was evaluated. Results: A total of 343 patients (86 years, 98 males) were included. The median value of the peak velocity at the aortic valve was 4.4 (4.0, 4.8) m/s and the median SVI was 65.5 (48.9, 86.9) mL/m2. A lower SVI tended to be associated with a lower cardiac output, whereas a higher SVI was associated with a higher plasma volume. The SVI was independently associated with the 2-year cardiac death or heart failure readmission after TAVR with a hazard ratio of 1.09 (95% confidence interval 1.01–1.18, p = 0.041), adjusted for potential confounders. A calculated cutoff of SVI was 70.2 mL/m2, which significantly stratified the cumulative incidence of the primary outcome (10% versus 4%, p = 0.033). Conclusion: A high baseline SVI, which was associated with systemic congestion, was associated with a higher incidence of cardiac death or heart failure readmission after TAVR. Further studies are warranted to clarify the detailed cardio–splenic relationship and implication of measuring the SVI in this cohort.


  • Open Access

    Prognostic Impact of Modified H2FPEF Score in Patients Receiving Trans-Catheter Aortic Valve Replacement

    by Kousuke Akao, Teruhiko Imamura, Shuhei Tanaka, Hiroshi Onoda, Ryuichi Ushijima, Mitsuo Sobajima, Nobuyuki Fukuda, Hiroshi Ueno, Koichiro Kinugawa

    Background: H2FPEF is a recently introduced score for the diagnosis of heart failure with preserved ejection fraction (HFpEF). Many patients with severe aortic stenosis have clinical/subclinical HFpEF and have worsening heart failure even after trans-catheter aortic valve replacement (TAVR). We investigated the prognostic impact of the H2FPEF score in TAVR candidates. Methods: Patients undergoing TAVR procedures at a single academic center between 2015 and 2022 were included. The H2FPEF score was calculated using baseline characteristics before TAVR. The prognostic impact of the score on the post-TAVR composite endpoint, consisting of all-cause death and heart failure readmissions during the 2-year observation period, was evaluated. Results: A total of 244 patients (median age 86 years, 70 males) were included. The median value of H2FPEF score was 3 (2, 4). The score was significantly associated with the primary outcome with a hazard ratio of 1.33 (95% confidence interval 1.02–1.74, p = 0.036). We constructed a modified H2FPEF score by adjusting cutoffs of several items for better prognostic stratification (i.e., age and body mass index). A modified score had a higher area under the curve than the original one (0.65 vs. 0.59, p = 0.028) and was independently associated with the primary outcome with an adjusted hazard ratio of 1.22 (95% confidence interval 1.01–1.49, p = 0.047). Conclusions: A modified H2FPEF score, which was originally developed to diagnose the presence of HFpEF, could be used to risk-stratify elderly patients receiving TAVR. The clinical utility of this score should be validated in future studies.


  • Open Access

    Prognostic Impact of Polypharmacy following Trans-Catheter Aortic Valve Replacement

    by Teruhiko Imamura, Nikhil Narang, Ryuichi Ushijima, Mitsuo Sobajima, Nobuyuki Fukuda, Hiroshi Ueno, Koichiro Kinugawa

    Background: Polypharmacy in elderly patients with various comorbidities is associated with mortality and morbidity. However, the prognostic impact of polypharmacy in patients with severe aortic stenosis receiving trans-catheter aortic valve replacement remains unknown. Methods: Patients with severe aortic stenosis who received trans-catheter aortic valve replacement between 2015 and 2022 and were followed up at our institute following index discharge were included in this retrospective study. The impact of polypharmacy, which was defined as medication numbers ≥10 at index discharge, upon 2-year all-cause death was investigated. Results: A total of 345 patients (median age 85 [83, 89] years old, 99 (29%) men) were included. Median medication number was 9 (7, 10) at the index discharge and 88 (26%) were classified as receiving polypharmacy. Frailty index, including mini-mental state examination and CSHA score, were not significantly different between those with and without polypharmacy (p > 0.05 for both). Polypharmacy was associated with higher 2-year cumulative mortality with an adjusted hazard ratio of 21.4 (95% confidence interval, 6.06–74.8, p < 0.001). As a sub-analysis, the number of cardiovascular medications was not associated with 2-year mortality (hazard ratio 1.12, 95% confidence interval 0.86–1.48, p = 0.46), whereas a higher number of non-cardiovascular medications was associated with an incremental increase in 2-year mortality with a hazard ratio of 1.39 (95% confidence interval, 1.15–1.63, p < 0.001). Conclusions: In elderly patients with severe aortic stenosis, polypharmacy was associated with worse short-term survival following trans-catheter aortic valve replacement. Prognostic implication of aggressive intervention to decrease the amount of medication among those receiving TAVR requires further prospective studies.


  • Open Access

    Prognostic Impact of Baseline Six-Minute Walk Distance following Trans-Catheter Aortic Valve Replacement

    by Teruhiko Imamura, Nikhil Narang, Ryuichi Ushijima, Mitsuo Sobajima, Nobuyuki Fukuda, Hiroshi Ueno, Koichiro Kinugawa

    Background: The six-minute walk test is a practical tool for assessing functional capacity in patients with a variety of etiologies including pulmonary disease and heart failure. Six-minute walk distance (6MWD) is associated with mortality and morbidity in patients with a variety of comorbidities. We aimed to assess the prognostic impact of baseline 6MWD in patients with severe aortic stenosis undergoing trans-catheter aortic valve replacement (TAVR). Methods: Patients with severe aortic stenosis who underwent a six-minute walk test after index admission and underwent TAVR between 2015 and 2022 were included in this retrospective study. Patients were followed up for two years or until November 2022 following TAVR. The impact of baseline 6MWD on the primary composite outcome, defined as all-cause death and all-cause readmission during the 2-year observation period following index discharge, was assessed. Results: A total of 299 patients (median age 86 years old, 85 men) were included. They received a 6-min walk test prior to TAVR, underwent successful TAVR procedures, and were discharged alive. The median baseline 6MWD was 204 (143, 282) meters. Shorter baseline 6MWD was associated with higher cumulative incidence of the primary outcome with an adjusted hazard ratio of 0.76 (95% confidence interval 0.58–1.01, p = 0.055) with a cutoff 6MWD of 178 m during the 2-year observation period after index discharge. Conclusions: Overall, functional capacity was impaired in the elderly patients with severe aortic stenosis prior to TAVR. Patients with severe aortic stenosis having shorter baseline 6MWD tended to have higher rates of morbidity and mortality after successful TAVR. The clinical implication of aggressive cardiac rehabilitation to improve patients’ functional capacity and 6MWD-guided optimal patient selection remain the future concerns.


  • Open Access

    A Rescue Use of ECPELLA for Sepsis-Induced Cardiogenic Shock Followed by Mitral Valve Replacement

    by Makiko Nakamura, Teruhiko Imamura, Akira Oshima, Mitsuo Sobajima, Shigeki Yokoyama, Toshio Doi, Kazuaki Fukahara, Koichiro Kinugawa

    The use of veno-arterial extracorporeal membrane oxygenation (ECMO) in patients with sepsis-induced cardiogenic shock has been reported, but the clinical implication of the Impella percutaneous axial-flow left ventricular assist device for such patients remains unknown. We had a 37-year-old man with septic shock and severely reduced cardiac function. Veno-arterial ECMO and concomitant Impella CP support ameliorated his end-organ dysfunction and achieved cardiac recovery, whereas severe mitral valve regurgitation due to chordal rupture developed later. Mitral valve replacement concomitant with ECMO removal as well as an Impella upgrade successfully treated the patient. ECMO and Impella support might be an effective therapeutic strategy for the bridge to recovery in patients with sepsis-induced cardiogenic shock; however, paying attention to mitral chordal rupture is highly encouraged.


  • Open Access

    Trans-Apical Transcatheter Aortic Valve Replacement in a Dialysis Patient with Systolic Heart Failure

    by Akira Oshima, Teruhiko Imamura, Hiroshi Onoda, Yohei Ueno, Ryuichi Ushijima, Mitsuo Sobajima, Nobuyuki Fukuda, Shigeki Yokoyama, Toshio Doi, Kazuaki Fukahara, et al.

    Mortality and morbidity remain high following transcatheter aortic valve replacement (TAVR) in dialysis patients or those with low left ventricular ejection fraction. Therapeutic strategy for those with these comorbidities remains unestablished. We had a dialysis patient with peripheral artery disease and low left ventricular ejection fraction, who received successfully scheduled trans-apical TAVR following sufficient reverse remodeling by 3-month optimal medical therapy. Our strategy should be validated in a larger robust cohort.

  • Open Access

    Association between Lung Fluid Levels Estimated by Remote Dielectric Sensing Values and Invasive Hemodynamic Measurements

    by Teruhiko Imamura, Masakazu Hori, Yohei Ueno, Nikhil Narang, Hiroshi Onoda, Shuhei Tanaka, Makiko Nakamura, Naoya Kataoka, Mitsuo Sobajima, Nobuyuki Fukuda, et al.

    Background: Remote dielectric sensing (ReDS™) is an electromagnetic-based technology used to noninvasively measure lung fluid levels. The association between ReDS values and invasively measured hemodynamics, particularly among those with small physics, remains unknown. Methods: Consecutive patients with chronic heart failure who were admitted to our institute and underwent invasive right heart catheterization as well as simultaneous ReDS measurement at clinically stable conditions between September and November 2021 were prospectively included. The colinearity between ReDS values and pulmonary capillary wedge pressure was studied. Results: In total, 30 patients (median 79 (73, 84) years old, 13 men) were included. Median ReDS value was 26% (22%, 28%). ReDS values had a moderate collinearity with pulmonary capillary wedge pressure (r = 0.698, p < 0.001), even among those with a body height < 155 cm. ReDS values with a cutoff of 28% predicted a pulmonary capillary wedge pressure > 15 mmHg with sensitivity 0.70 and specificity 0.75. Conclusions: An electromagnetic-based engineering ReDS might be a potential tool to estimate cardiac pressure in patients with heart failure, including those with small physics.


  • Open Access

    Clinical Implications of Changes in Respiratory Instability Following Transcatheter Aortic Valve Replacement

    by Yohei Ueno, Teruhiko Imamura, Akira Oshima, Hiroshi Onoda, Ryuichi Ushijima, Mitsuo Sobajima, Nobuyuki Fukuda, Hiroshi Ueno, Koichiro Kinugawa

    Background: Respiratory instability, which can be quantified using respiratory stability time (RST), is associated with the severity and prognostic impact of the disease in patients with chronic heart failure. However, its clinical implications in patients with severe aortic stenosis receiving transcatheter aortic valve replacement (TAVR) remain unknown. Methods: Patients who received TAVR and had paired measurements of RST at a baseline and one week following TAVR were prospectively included. Changes in RST following TAVR and its impact on post-TAVR heart failure readmissions were investigated. Results: Seventy-one patients (median age, 86 years old; 35% men) were included. The baseline RST was correlated with the severity of heart failure including elevated levels of plasma B-type natriuretic peptide (p < 0.05 for all). RST improved significantly following TAVR from 34 (26, 37) s to 36 (33, 38) s (p < 0.001). Post-TAVR lower RST (n = 18) was associated with a higher 2-year cumulative incidence of heart failure readmission (21% vs. 8%, p = 0.039) with a hazard ratio of 5.47 (95% confidence interval 0.90–33.2). Conclusion: Overall, respiratory instability improved following TAVR. Persistent respiratory instability following TAVR was associated with heart failure recurrence.