SMSamuel Mumford

Samuel Mumford

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Samuel Mumford has a total of 35 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Emergence of ferromagnetism through the metal-insulator transition in undoped indium tin oxide films

    by Samuel Mumford, Tiffany Paul, Aharon Kapitulnik

    We present a detailed study of the emergence of bulk ferromagnetism in low-carrier-density samples of undoped indium tin oxide. We use annealing to increase the density of oxygen vacancies and change the sample morphology without introducing impurities through the metal insulator transition (MIT). We utilize a novel and highly sensitive “Corbino-disk torque magnetometry” technique to simultaneously measure the thermodynamic and transport effects of magnetism on the same sample after successive annealing. With increased sample granularity, the carrier density increases, the sample becomes more metallic, and ferromagnetism appears as the resistance approaches the MIT. Ferromagnetism is observed through the detection of magnetization hysteresis, the anomalous Hall effect (AHE), and hysteretic magnetoresistance. A sign change of the AHE as the MIT is approached may elucidate the interplay between the impurity band and the conduction band on the weakly insulating side of the MIT.


  • Sample shape and boundary dependence of measured transverse thermal properties

    by Samuel Mumford, Tiffany Paul, Erik Kountz, Aharon Kapitulnik

    Despite increased interest in thermal Hall measurements for the analysis of insulating quantum materials, there remains large uncertainty in such measurements due to contact misalignment. In this paper, we propose that sample geometry and uncertain boundary conditions provide an additional source of uncertainty in the measurement of D x y or κ x y . By running simple simulations in an open source finite-element solver, we demonstrate that measured D x y can be changed by a non-negligible fraction in samples with similar width and length. This geometric corrective factor depends on the distinction between a uniform heat flow and constant temperature boundary couplings to a bath. Sample geometry and boundary conditions can be accounted for through simulation or by using rectangular samples to make thermal Hall measurements more reliable and reproducible. Finally, we detail a contactless optical method for measuring D x y based on an existing photothermal microscope technique. This method is insensitive to the longitudinal diffusivity pollution caused by contact misalignment.


  • Open Access

    Sample Shape and Boundary Dependence of Measured Transverse Thermal Properties

    by Samuel Mumford, Tiffany Paul, Erik Kountz, Aharon Kapitulnik

    Despite increased interest in thermal Hall measurements for the analysis of insulating quantum materials, there remains large uncertainty in such measurements due to contact misalignment. In this paper we propose that sample geometry and uncertain boundary conditions may account for uncertainty in the measurement of $D_{xy}$ or $\kappa_{xy}$ as well. By running simple simulations in an open source finite-element solver, we demonstrate that measured $D_{xy}$ in a thermal Hall bar can be changed by a factor of order unity in samples with similar width and length. This geometric corrective factor depends on the distinction between uniform heat flow and constant temperature boundary couplings to a bath. Sample geometry and boundary conditions can be accounted for through simulation or by using rectangular samples to make thermal Hall measurements more reliable and reproducible when the amplitude of $\kappa_{xy}$ is important. Finally, we propose a contactless optical method for measuring $D_{xy}$ which is insensitive to the longitudinal diffusivity pollution caused by contact misalignment.

  • A cantilever torque magnetometry method for the measurement of Hall conductivity of highly resistive samples

    by Samuel Mumford, Tiffany Paul, Seung Hwan Lee, Amir Yacoby, Aharon Kapitulnik

    We present the first measurements of Hall conductivity utilizing a torque magnetometry method. A Corbino disk exhibits a magnetic dipole moment proportional to Hall conductivity when voltage is applied across a test material. This magnetic dipole moment can be measured through torque magnetometry. The symmetry of this contactless technique allows for the measurement of Hall conductivity in previously inaccessible materials. Finally, we calculate a low-temperature noise bound, demonstrate the lack of systematic errors, and measure the Hall conductivity of sputtered indium tin oxide.


  • Progress on the ARIADNE Axion Experiment

    by A. A. Geraci for the ARIADNE Collaboration, H. Fosbinder-Elkins, C. Lohmeyer, J. Dargert, M. Cunningham, M. Harkness, E. Levenson-Falk, S. Mumford, A. Kapitulnik, A. Arvanitaki, et al.


  • Open Access

    Temperature uniformity in the CERN CLOUD chamber

    by António Dias, Sebastian Ehrhart, Alexander Vogel, Christina Williamson, João Almeida, Jasper Kirkby, Serge Mathot, Samuel Mumford, Antti Onnela

    The CLOUD (Cosmics Leaving OUtdoor Droplets) experiment at CERN (European Council for Nuclear Research) investigates the nucleation and growth of aerosol particles under atmospheric conditions and their activation into cloud droplets. A key feature of the CLOUD experiment is precise control of the experimental parameters. Temperature uniformity and stability in the chamber are important since many of the processes under study are sensitive to temperature and also to contaminants that can be released from the stainless steel walls by upward temperature fluctuations. The air enclosed within the 26 m3 CLOUD chamber is equipped with several arrays (strings) of high precision, fast-response thermometers to measure its temperature. Here we present a study of the air temperature uniformity inside the CLOUD chamber under various experimental conditions. Measurements were performed under calibration conditions and run conditions, which are distinguished by the flow rate of fresh air and trace gases entering the chamber at 20 and up to 210 L min−1, respectively. During steady-state calibration runs between −70 and +20 °C, the air temperature uniformity is better than ±0.06 °C in the radial direction and ±0.1 °C in the vertical direction. Larger non-uniformities are present during experimental runs, depending on the temperature control of the make-up air and trace gases (since some trace gases require elevated temperatures until injection into the chamber). The temperature stability is ±0.04 °C over periods of several hours during either calibration or steady-state run conditions. During rapid adiabatic expansions to activate cloud droplets and ice particles, the chamber walls are up to 10 °C warmer than the enclosed air. This results in temperature differences of ±1.5 °C in the vertical direction and ±1 °C in the horizontal direction, while the air returns to its equilibrium temperature with a time constant of about 200 s.