ASAnn Saterbak

Ann Saterbak

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Ann Saterbak has a total of 71 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Dermatological Effects of a Beeswax-Pine Resin Mixture on Abdominal Skin: A Proof-of-Concept Study Supporting the Development of an Affordable Investigational Ostomy Pouching System in Low-Income Regions

    by Darienne Rogers, Joanna Peng, Amy Guan, Westbrook Jensen, Jessica Alvarez, Pooja Patel, Ayesiga Herman, Dorothy Dow, Ann Saterbak, Amy Barto

    PURPOSE: The purpose of this study was to compare short-term abdominal skin responses, including erythema and edema, after the application of 2 beeswax-pine resin mixtures and a hydrocolloid sample prepared from an ostomy barrier ring used as an active comparator. DESIGN: Proof-of-concept, blinded, within-participant comparative skin irritation study. SUBJECTS AND SETTING: The sample comprised 50 healthy volunteers over 18 years of age; 54% (n = 27) were female; 68% (n = 34) were White, 18% (n = 9) were Asian, 4% (n = 2) were Black, 6% (n = 3) were multiracial, and 12% (n = 6) were Hispanic. The study setting was Duke University campus, located in the southeastern region of the United States. METHODS: Participants simultaneously wore 3 samples: the first was a beeswax-pine resin sample with beeswax sourced in the United States; the second was a beeswax-pine resin sample with beeswax sourced from Tanzania; and the third was a hydrocolloid active comparator from an ostomy barrier ring. Participants were examined by a physician on day 1 for preexisting dermatologic conditions on the lower abdomen, after which the 3 samples were placed and each covered with a thin-film wound dressing. The samples and dressings were removed and replaced daily, and a daily survey prompted self-reporting of adverse effects (itching and redness). Participants returned on day 7 for follow-up evaluation. The physician rated edema and erythema using the Draize skin scale (a previously validated instrument). Equivalence of the difference in mean day 7 combined Draize scores between each beeswax-pine resin mixture and the active comparator was tested using the Schuirmann two one-sided test procedure for equivalence. RESULTS: Day 7 Draize score assessments were analyzed from 35 subjects; 15 did not complete data collection for all end points. Both the United States and Tanzanian sourced beeswax-pine resin preparations were equivalent to the active comparator based on the mean differences in Draize scores (erythema plus edema) using the two one-sided test procedures for equivalence. CONCLUSIONS: The beeswax-pine resin mixtures did not produce increased short-term skin irritation when compared with the hydrocolloid active comparator, supporting further evaluation of this material as a skin-contact adhesive in an investigational ostomy pouching system.

  • Academic Benefits and Challenges of Cross-Cultural Biomedical Engineering Partnerships

    by Robert Ssekitoleko, Sara Mehta, Jackson Park, Jenna L Mueller, Tamara N. Fitzgerald, Ann Saterbak

  • Simulation Device for Uterine Atony in the Identification of Postpartum Hemorrhage

    by Jacklyn L. Herzberg, Morgan A. Bedingfield, Allison I. Goehringer, Skylah N. Connelly, Ashley R. Rosen, Bse Perisa S. Ashar, Ann Saterbak

    Introduction: Women who experience postpartum hemorrhage (PPH) after giving birth rapidly lose blood, which may lead to shock or death without immediate intervention. PPH most often results from uterine atony, when the uterus fails to contract after delivery. Worldwide, PPH causes 10 deaths hourly, with most deaths occurring in low-income settings. In these settings, medical staff may lack the training to identify the complication. Although uterine atony training models exist, many cost >$5000. Methods: To address the need for affordable training models, the Hemorrhage Education Reimagined (HER) model was created to train medical professionals to identify an atonic uterus through a bimanual examination after vaginal delivery. Twenty-five obstetrics and gynecology residents and attendings from an academic hospital evaluated the stages of atony of the HER model. Participants were asked to physically evaluate the model and give feedback on improvements to the model. Results: More than 80% of medical professionals were able to correctly discern an atonic uterus from a healthy uterus, but many had difficulty differentiating the moderately atonic uterus model from the severely atonic uterus model. The model met established design criteria, including low cost (<$100) and durability (more than 100 uses). Conclusions: The HER model is a low-cost uterine atony model. Its implementation empowers medical professionals to practice identifying uterine atony, with potential implications to improve the diagnosis of PPH. Current limitations include use of high-cost fabrication methods, such as laser cutting and 3D printing. Lower-cost options could include constructing the abdomen using cardboard or wood and hand molding the vaginal canal using clay.

  • Bridging engineering education and local innovation ecosystems in Africa through the invention education model

    by Theresa Mkandawire, Ashley Taylor, Matthew Wettergreen, Ann Saterbak, Padraic Casserly, Williams Baah, Will Moyo, Julia Jenjezwa, Hillary Lodzanyama, John Msumba, et al.

    This article shares lessons and impacts of solving engineering problems through Invention Education (IvE) in Africa. IvE is a transdisciplinary approach to engineering education that cultivates an ecosystem for fostering technical innovation to solve local and global challenges. The article shares a model of IvE, which includes the establishment and expansion of design studios as hands-on prototyping spaces for technology design, curricular integration of active learning and problem-based learning across engineering departments, and establishment of innovation ecosystem partnerships. Invention Education is a novel, transdisciplinary approach to engineering education that fosters technical innovation, improves health outcomes, and reduces poverty. While global evidence of IvE’s impact in high-income settings is well-documented, few successful models have been developed by and collaboratively created with universities in Africa. Our multi-institutional team, representing institutions from Malawi, Nigeria, Tanzania, the United States, and Ethiopia, has developed a scalable IvE model designed to empower engineering students in sub-Saharan Africa to solve real-world challenges. This article presents key outcomes of the IvE model, including the establishment of design studios as hubs for innovation, curricular integration of active learning methodologies, and the strengthening of partnerships within local innovation ecosystems. Drawing on 8 years of implementation, this work provides critical insights into the advancement of engineering education and innovation ecosystems in a geographical region that has untapped potential for these models. Finally, the discussion outlines a forward-looking plan to assess the sustainability of the model and its potential for broader scaling across diverse regional contexts.

  • Open Access

    Incorporating a Hands-On Device-Based Activity in a Human Factors Biomedical Engineering Course in Sub-Saharan Africa

    by Alick O Vweza, Sara Mehta, Matthew Wettergreen, Ann Saterbak

    A challenge in building the biomedical engineering human factors course at Malawi University of Business and Applied Sciences was integrating meaningful direct experiences with medical products. The instructor also noticed a significant gap between the topics in the course and their surrounding clinical context, a low-income setting. Recognizing that devices should be designed and evaluated in the context of the local users’ needs and situations, new hands-on modules were created and implemented in this BME human factors course. Students were asked to critically evaluate and make recommendations to improve the human factors aspects of the software and hardware of the IMPALA, a vital signs monitoring device developed for use in Malawi. Engaging with this medical device, students observed and understood many issues discussed in human factors, including the design of ports, controls, and other user interfaces. The collaboration between the course and the IMPALA project harnessed the local expertise of students to improve the design of a new patient monitoring system. Thus, the IMPALA project itself benefited from this collaboration. Second, students greatly benefited from applying the class concepts to the IMPALA. Students were engaged far more during the interactive components than during the lecture components. Many students successfully translated their knowledge on human factors to their final-year design project.


  • Open Access

    Design and Development of a Novel System for Remote Control of Stationary Oxygen Concentrator Flow Rate

    by Nikhil Gadiraju, Nikhil Peterson, Jessica Shah, Annabelle Chu, Michael A Larbie, Amy Bu, Ann Saterbak

    Purpose: Long-term oxygen therapy involves utilizing stationary oxygen concentrators to allow patients with respiratory illnesses to attain sufficient blood oxygenation via supplemental oxygen. Disadvantages of these devices include their lack of remote adjustability and domiciliary accessibility. To adjust oxygen flow, patients typically walk across their homes – a physically taxing activity – to manually rotate the knob of the concentrator flowmeter. The purpose of this investigation was to develop a control system device that allows patients to remotely adjust the oxygen flow rates on their stationary oxygen concentrator. Methods: The engineering design process was used to develop the novel FLO2 device. The two-part system is composed of 1) a smartphone application and 2) an adjustable concentrator attachment unit that mechanically interfaces with the stationary oxygen concentrator flowmeter. Results: Product testing indicates that users successfully communicated to the concentrator attachment from a maximum distance of 41m in an open field, suggesting usability from anywhere inside a standard home. The calibration algorithm adjusted oxygen flow rates with an accuracy of ± 0.019 LPM and a precision of ± 0.042 LPM. Conclusion: Initial design testing suggests the device as a reliable and accurate method of wirelessly adjusting oxygen flow on a stationary oxygen concentrator, but further testing should be performed on different stationary oxygen concentrator models.


  • Open Access

    Simulation device for shoulder reductions: overview of prototyping, testing, and design instructions

    by Sorab Taneja, Will Tenpas, Mehul Jain, Peter Alfonsi, Abhinav Ratagiri, Ann Saterbak, Jason Theiling

    Background: Shoulder dislocations are common occurrences, yet there are few simulation devices to train medical personnel on how to reduce these dislocations. Reductions require a familiarity with the shoulder and a nuanced motion against strong muscle tension. The goal of this work is to describe the design of an easily replicated, low-cost simulator for training shoulder reductions. Materials and methods: An iterative, stepwise engineering design process was used to design and implement ReducTrain. A needs analysis with clinical experts led to the selection of the traction-countertraction and external rotation methods as educationally relevant techniques to include. A set of design requirements and acceptance criteria was established that considered durability, assembly time, and cost. An iterative prototyping development process was used to meet the acceptance criteria. Testing protocols for each design requirement are also presented. Step-by-step instructions are provided to allow the replication of ReducTrain from easily sourced materials, including plywood, resistance bands, dowels, and various fasteners, as well as a 3D-printed shoulder model, whose printable file is included at a link in the Additional file 1: Appendix. Results: A description of the final model is given. The total cost for all materials for one ReducTrain model is under US $200, and it takes about 3 h and 20 min to assemble. Based on repetitive testing, the device should not see any noticeable changes in durability after 1000 uses but may exhibit some changes in resistance band strength after 2000 uses. Discussion: The ReducTrain device fills a gap in emergency medicine and orthopedic simulation. Its wide variety of uses points to its utility in several instructional formats. With the rise of makerspaces and public workshops, the construction of the device can be easily completed. While the device has some limitations, its robust design allows for simple upkeep and a customizable training experience. Conclusion: A simplified anatomical design allows for the ReducTrain model to serve as a viable training device for shoulder reductions.