Luiza Maria Ferreira Dantas
Research Subjects
Luiza Maria Ferreira Dantas has a total of 45 co-authors. Here are the top co-authors by number of shared publications:
- Iranaldo Santos da Silva
Department of Chemical Technology, Federal University of Maranhão, São Luís, Brazil
7 shared publications - Auro Atsushi Tanaka
Department of Chemistry, Federal University of Maranhão, Av. dos Portugueses, 1966, São Luís, MA 65080-805, Brazil
3 shared publications - Rodrigo Alejandro Abarza Munoz
Federal University of Uberlândia
3 shared publications - Dianderson Cristiano M. Ferreira
Universidade Federal de Uberlândia
2 shared publications Eduardo M. Richter
2 shared publicationsIranaldo S. da Silva
2 shared publications
Latest Publications
- Open Access
- 11 September 2026
- Published by Elsevier in SSRN Electronic Journal
Lab-made stencil-printed sensor for acetaminophen determination in biological samples: Towards point-of-care assessment in intoxication cases
Acetaminophen (ACT) is an analgesic and antipyretic widely used to relieve headaches, fever, and cold symptoms. As prescribed by a doctor it is a safe medicine; however, excessive consumption can cause hepatotoxicity and nephrotoxicity, which are associated with liver and kidney damage. Despite numerous electroanalytical methods for ACT detection, simpler and more portable platforms for rapid intoxication assessment are still needed. Therefore, this study reports the development of a simple, sensitive, and accurate method for determining ACT based on a lab-made stencil-printed sensor fabricated using repurposed margarine packaging as a substrate and commercial conductive ink composed of carbon black and graphite (SPE/CB-G), for the analysis of pharmaceutical formulations and biological samples such as urine, oral fluid, and plasma. At an ACT concentration of 0.20 mmol L-1, a well-defined redox couple was observed, with oxidation and reduction peak potentials at +0.37 V and +0.12 V (vs Ag pseudo-reference), respectively. All experimental conditions were optimized, resulting in a B-R buffer pH 6.0 with a concentration of 0.12 mol L-1 as supporting electrolyte. Square-wave voltammetry was selected for the proposed method and optimized using a central composite design, yielding optimal parameters of 20 Hz frequency, 10 mV potential step, and 25 mV amplitude. The calibration curves were constructed using standard solutions ranging from 100 to 1000 µmol L-1, with a limit of detection of 7.7 µmol L-1. The effect of organic interferents, such as ascorbic acid and uric acid, was studied at ratios of 10:1, 50:1, and 100:1 ([ACT]:[interferent]), with no significant difference observed. The proposed method was successfully applied to the analysis of the pharmaceutical sample, yielding an accuracy of (94 ± 2%). For each human biological sample three different concentrations were used, yielding recoveries ranging from (101 ± 2% to 110 ± 2%), demonstrating good accuracy and precision, with satisfactory recoveries and low variability, indicating that the methodology is suitable for quantifying the analyte in different complex matrices. Furthermore, SPE/CB-G shows great potential as a rapid, simple, and selective point-of-care sensor for assessing ACT intoxication in clinical settings.
- 11 September 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessLab-made stencil-printed sensor for acetaminophen determination in biological samples: Towards point-of-care assessment in intoxication cases
Acetaminophen (ACT) is an analgesic and antipyretic widely used to relieve headaches, fever, and cold symptoms. As prescribed by a doctor it is a safe medicine; however, excessive consumption can cause hepatotoxicity and nephrotoxicity, which are associated with liver and kidney damage. Despite numerous electroanalytical methods for ACT detection, simpler and more portable platforms for rapid intoxication assessment are still needed. Therefore, this study reports the development of a simple, sensitive, and accurate method for determining ACT based on a lab-made stencil-printed sensor fabricated using repurposed margarine packaging as a substrate and commercial conductive ink composed of carbon black and graphite (SPE/CB-G), for the analysis of pharmaceutical formulations and biological samples such as urine, oral fluid, and plasma. At an ACT concentration of 0.20 mmol L-1, a well-defined redox couple was observed, with oxidation and reduction peak potentials at +0.37 V and +0.12 V (vs Ag pseudo-reference), respectively. All experimental conditions were optimized, resulting in a B-R buffer pH 6.0 with a concentration of 0.12 mol L-1 as supporting electrolyte. Square-wave voltammetry was selected for the proposed method and optimized using a central composite design, yielding optimal parameters of 20 Hz frequency, 10 mV potential step, and 25 mV amplitude. The calibration curves were constructed using standard solutions ranging from 100 to 1000 µmol L-1, with a limit of detection of 7.7 µmol L-1. The effect of organic interferents, such as ascorbic acid and uric acid, was studied at ratios of 10:1, 50:1, and 100:1 ([ACT]:[interferent]), with no significant difference observed. The proposed method was successfully applied to the analysis of the pharmaceutical sample, yielding an accuracy of (94 ± 2%). For each human biological sample three different concentrations were used, yielding recoveries ranging from (101 ± 2% to 110 ± 2%), demonstrating good accuracy and precision, with satisfactory recoveries and low variability, indicating that the methodology is suitable for quantifying the analyte in different complex matrices. Furthermore, SPE/CB-G shows great potential as a rapid, simple, and selective point-of-care sensor for assessing ACT intoxication in clinical settings.
- Open Access
- 29 August 2026
- Published by Elsevier in SSRN Electronic Journal
Development and characterization of an Immunosensor for Anti-Mycobacterium leprae IgG Detection using MPML14 Peptide
Leprosy remains a significant public health challenge in hyperendemic regions, with Brazil reporting the second highest global incidence and a prevalence rate of approximately 22 cases per 100,000 inhabitants, significantly higher than the World Health Organization (WHO) elimination threshold of 1 per 10,000. It is evident that traditional diagnostic methods possess substantial limitations, primarily due to their predominantly invasive nature and reliance on laboratory equipment and highly skilled professionals. This study describes the development of a label-free electrochemical immunosensor for the detection of anti-Mycobacterium leprae IgG antibodies using the synthetic peptide MPML14, a mimetic of the HSP60 protein, as a bioreceptor immobilized on screen-printed gold electrodes via EDC/NHS activation chemistry. The biosensor (BIO) fabrication was monitored by electrochemical impedance spectroscopy (EIS), which confirmed successful surface modification through progressive increases in charge-transfer resistance (Rct) at each step. Differential pulse voltammetry (DPV) analysis demonstrated discrimination between positive (PS) and negative (NS) serum samples, with relative currents (Ip/Ip₀) of 0.79 and 0.62, respectively, at 1:100 dilution. A linear correlation (R² = 0.979) was observed between relative current variation and the logarithm of PS sample dilution across the range of 1:50 to 1:600 dilutions, establishing a threshold value (ΔIp/Ip₀ = 0.48) for qualitative discrimination. The selectivity was validated using serum samples from healthy children with no family history of leprosy, as well as from adults with leishmaniasis or HIV infection. All of these individuals produced subthreshold responses. These results demonstrate the potential of MPML14-based electrochemical immunosensors as low-cost, portable tools for qualitative leprosy screening in resource-limited settings.
- 29 August 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessDevelopment and characterization of an Immunosensor for Anti-Mycobacterium leprae IgG Detection using MPML14 Peptide
Leprosy remains a significant public health challenge in hyperendemic regions, with Brazil reporting the second highest global incidence and a prevalence rate of approximately 22 cases per 100,000 inhabitants, significantly higher than the World Health Organization (WHO) elimination threshold of 1 per 10,000. It is evident that traditional diagnostic methods possess substantial limitations, primarily due to their predominantly invasive nature and reliance on laboratory equipment and highly skilled professionals. This study describes the development of a label-free electrochemical immunosensor for the detection of anti-Mycobacterium leprae IgG antibodies using the synthetic peptide MPML14, a mimetic of the HSP60 protein, as a bioreceptor immobilized on screen-printed gold electrodes via EDC/NHS activation chemistry. The biosensor (BIO) fabrication was monitored by electrochemical impedance spectroscopy (EIS), which confirmed successful surface modification through progressive increases in charge-transfer resistance (Rct) at each step. Differential pulse voltammetry (DPV) analysis demonstrated discrimination between positive (PS) and negative (NS) serum samples, with relative currents (Ip/Ip₀) of 0.79 and 0.62, respectively, at 1:100 dilution. A linear correlation (R² = 0.979) was observed between relative current variation and the logarithm of PS sample dilution across the range of 1:50 to 1:600 dilutions, establishing a threshold value (ΔIp/Ip₀ = 0.48) for qualitative discrimination. The selectivity was validated using serum samples from healthy children with no family history of leprosy, as well as from adults with leishmaniasis or HIV infection. All of these individuals produced subthreshold responses. These results demonstrate the potential of MPML14-based electrochemical immunosensors as low-cost, portable tools for qualitative leprosy screening in resource-limited settings.
- 4 May 2026
- Published by Brazilian Journal of Analytical Chemistry in Brazilian Journal of Analytical Chemistry
Laser-Induced Graphene Sensor for Electrochemical Determination of Nimesulide
Nimesulide (NMS) is a sulfonamide-class non-steroidal anti-inflammatory drug widely used in pharmaceutical formulations, whose reliable quantification is essential for quality control. In this work, an unmodified laser-induced graphene electrode (LIGe), fabricated by direct CO2 laser ablation of polyimide, is proposed for the electrochemical determination of NMS using square-wave voltammetry (SWV). Voltammetric studies revealed that NMS oxidation is an irreversible, diffusion-controlled process that involves the transfer of two protons and two electrons. After systematic optimization of pH and instrumental parameters, the method exhibited a wide linear working range from 11.0 to 131 µmol L-1, with a detection limit of 1.30 µmol L-1. The sensor showed good repeatability (RSD < 5%, n = 10) and was successfully applied to the analysis of pharmaceutical tablets, yielding results consistent with the declared content. Accuracy was further evaluated in synthetic urine, with recovery rates between 97% and 111%. Interference studies demonstrated that common non-electroactive urinary constituents caused only minor signal variations (<3%). Although the detection limit is higher than that reported for heavily modified electrodes, the proposed approach offers simplicity of fabrication, rapid analysis, disposability, and a broad linear range, which are notably advantageous for pharmaceutical quality control applications where analyte concentrations are relatively high. These results highlight unmodified LIG as a practical, cost-effective, and scalable sensing platform for routine nimesulide analysis.
- 4 May 2026
- Published by Brazilian Journal of Analytical Chemistry in Brazilian Journal of Analytical Chemistry
Laser-Induced Graphene Sensor for Electrochemical Determination of Nimesulide
Nimesulide (NMS) is a sulfonamide-class non-steroidal anti-inflammatory drug widely used in pharmaceutical formulations, whose reliable quantification is essential for quality control. In this work, an unmodified laser-induced graphene electrode (LIGe), fabricated by direct CO2 laser ablation of polyimide, is proposed for the electrochemical determination of NMS using square-wave voltammetry (SWV). Voltammetric studies revealed that NMS oxidation is an irreversible, diffusion-controlled process that involves the transfer of two protons and two electrons. After systematic optimization of pH and instrumental parameters, the method exhibited a wide linear working range from 11.0 to 131 µmol L-1, with a detection limit of 1.30 µmol L-1. The sensor showed good repeatability (RSD < 5%, n = 10) and was successfully applied to the analysis of pharmaceutical tablets, yielding results consistent with the declared content. Accuracy was further evaluated in synthetic urine, with recovery rates between 97% and 111%. Interference studies demonstrated that common non-electroactive urinary constituents caused only minor signal variations (<3%). Although the detection limit is higher than that reported for heavily modified electrodes, the proposed approach offers simplicity of fabrication, rapid analysis, disposability, and a broad linear range, which are notably advantageous for pharmaceutical quality control applications where analyte concentrations are relatively high. These results highlight unmodified LIG as a practical, cost-effective, and scalable sensing platform for routine nimesulide analysis.
- 1 January 2026
- Published by Sociedade Brasileira de Quimica (SBQ) in Journal of the Brazilian Chemical Society
Electroanalytical Sensing of Ivermectin Using a Carbon-Black-Modified Glassy‑Carbon Electrode
During the severe acute respiratory syndrome coronavirus (SARS-CoV-2) pandemic, ivermectin (IVM), a broad-spectrum antiparasitic drug, was one of the medications prescribed to manage symptoms. However, its effectiveness against the virus has not been conclusively demonstrated. The increased consumption of IVM raised environmental and health concerns, including bioaccumulation and microbial resistance. To address these issues, electroanalytical methods have been explored for IVM detection, offering advantages such as low cost, portability, and high sensitivity. Super-P carbon black (SPCB) is a conductive nanomaterial used to modify glassy carbon electrodes, enhancing electrochemical performance. In this work, electrochemical sensors based on SPCB were developed using the drop-casting technique for IVM sensing. Through studies using cyclic voltammetry (CV), it was determined that the mass transport for the glassy carbon electrode modified with Super-P carbon black (SPCB/GCE) is governed by the adsorption of the species. After parameter optimization for differential pulse voltammetry technique, the sensor exhibited a linear working range of 10-100 µmol L−1, a limit of detection (LOD) of 1.3 µmol L−1 , a limit of quantification (LOQ) of 4.2 µmol L−1, and a sensitivity of 0.101 µA µmol L−1 . The developed method was applied to analysis of pharmaceutical tablets, tap water, and synthetic urine.
- 1 January 2026
- Published by Sociedade Brasileira de Quimica (SBQ) in Journal of the Brazilian Chemical Society
Electroanalytical Sensing of Ivermectin Using a Carbon-Black-Modified Glassy‑Carbon Electrode
During the severe acute respiratory syndrome coronavirus (SARS-CoV-2) pandemic, ivermectin (IVM), a broad-spectrum antiparasitic drug, was one of the medications prescribed to manage symptoms. However, its effectiveness against the virus has not been conclusively demonstrated. The increased consumption of IVM raised environmental and health concerns, including bioaccumulation and microbial resistance. To address these issues, electroanalytical methods have been explored for IVM detection, offering advantages such as low cost, portability, and high sensitivity. Super-P carbon black (SPCB) is a conductive nanomaterial used to modify glassy carbon electrodes, enhancing electrochemical performance. In this work, electrochemical sensors based on SPCB were developed using the drop-casting technique for IVM sensing. Through studies using cyclic voltammetry (CV), it was determined that the mass transport for the glassy carbon electrode modified with Super-P carbon black (SPCB/GCE) is governed by the adsorption of the species. After parameter optimization for differential pulse voltammetry technique, the sensor exhibited a linear working range of 10-100 µmol L−1, a limit of detection (LOD) of 1.3 µmol L−1 , a limit of quantification (LOQ) of 4.2 µmol L−1, and a sensitivity of 0.101 µA µmol L−1 . The developed method was applied to analysis of pharmaceutical tablets, tap water, and synthetic urine.
- Open Access
- 17 January 2025
- Published by MDPI AG in Biosensors
- Vol. 15 (1) , 57
Electrochemical Biosensors 3D Printed by Fused Deposition Modeling: Actualities, Trends, and Challenges
The technology of 3D printing, particularly fused deposition modeling (FDM) 3D printing, has revolutionized the development of electrochemical biosensors, offering a versatile and cost-effective approach for clinical applications. This review explores the integration of FDM in fabricating biosensing platforms tailored for clinical diagnostics, emphasizing its role in detecting various biomarkers and viral pathogens. Advances in 3D printing materials, especially the emergence of bespoke conductive filaments, have allowed the production of highly customizable and efficient biosensors. A detailed discussion focuses on the design and application of these biosensors for viral detection, highlighting their potential to improve diagnostic accuracy. Furthermore, the review addresses current trends, including the push towards miniaturization and multianalyte detection, alongside challenges such as material optimization and regulatory hurdles. By providing a comprehensive overview, this work underscores the transformative impact of 3D-printed electrochemical biosensors in clinical diagnostics while also identifying critical areas for future research and development.
- 17 January 2025
- Published by MDPI AG in Biosensors
- Vol. 15 (1) , 57
Open AccessElectrochemical Biosensors 3D Printed by Fused Deposition Modeling: Actualities, Trends, and Challenges
The technology of 3D printing, particularly fused deposition modeling (FDM) 3D printing, has revolutionized the development of electrochemical biosensors, offering a versatile and cost-effective approach for clinical applications. This review explores the integration of FDM in fabricating biosensing platforms tailored for clinical diagnostics, emphasizing its role in detecting various biomarkers and viral pathogens. Advances in 3D printing materials, especially the emergence of bespoke conductive filaments, have allowed the production of highly customizable and efficient biosensors. A detailed discussion focuses on the design and application of these biosensors for viral detection, highlighting their potential to improve diagnostic accuracy. Furthermore, the review addresses current trends, including the push towards miniaturization and multianalyte detection, alongside challenges such as material optimization and regulatory hurdles. By providing a comprehensive overview, this work underscores the transformative impact of 3D-printed electrochemical biosensors in clinical diagnostics while also identifying critical areas for future research and development.
- 31 October 2023
- Published by Elsevier in Journal of Electroanalytical Chemistry
- Vol. 950
Electrochemical sensing of cysteine using a novel carbon black and cobalt phthalocyanine composite
- 31 October 2023
- Published by Elsevier in Journal of Electroanalytical Chemistry
- Vol. 950
Electrochemical sensing of cysteine using a novel carbon black and cobalt phthalocyanine composite
- 25 September 2021
- Published by Springer Nature in Chemical Papers
- Vol. 76 (1) , 575-583
Voltammetric and spectrophotometric studies of toxic disinfection by-product 2,6-dichloro-1,4-benzoquinone and its behavior with DNA
- 25 September 2021
- Published by Springer Nature in Chemical Papers
- Vol. 76 (1) , 575-583
Voltammetric and spectrophotometric studies of toxic disinfection by-product 2,6-dichloro-1,4-benzoquinone and its behavior with DNA
- 6 August 2021
- Published by Springer Nature in Monatshefte für Chemie - Chemical Monthly
- Vol. 152 (8) , 895-902
Voltammetric determination of sulfanilamide using a cobalt phthalocyanine chitosan composite
- 6 August 2021
- Published by Springer Nature in Monatshefte für Chemie - Chemical Monthly
- Vol. 152 (8) , 895-902
Voltammetric determination of sulfanilamide using a cobalt phthalocyanine chitosan composite