SCSungyoung Choi

Sungyoung Choi

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Sungyoung Choi has a total of 107 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Halbach-array-integrated high-throughput magnetic separation for T-cell isolation and CAR trnasduction

    by Hee Sik Shin, Sungyoung Choi

    High-throughput isolation of functional T cells is an important front-end step in cell-therapy manufacturing, yet scaling microfluidic magnetic separation is limited by the rapid decay of magnetic force with distance from the magnet. Here, we developed a Halbach-array-integrated microfluidic device for continuous-flow T-cell negative selection. The Halbach configuration focused magnetic flux toward the 450-μm-deep channel, extending effective magnetic capture across the channel depth. At a sample flow rate of 700 μL/min, the device achieved a purity of 93.8% and a recovery of 82.6%, corresponding to a cell-processing throughput of approximately 8.4 × 108 cells/h. Optimization experiments indicated that recovery loss at low flow rates and low input cell concentrations was associated with unintended magnetic retention of target T cells, potentially arising from nonspecific depletion-bead association. Increasing the flow rate to an optimal level reduced this target-cell loss, whereas excessive flow impaired outlet partitioning. T cells isolated using the device retained proliferation, chimeric antigen receptor (CAR) expression, CD4/CD8 composition, PD-1/TIM-3 profiles, and CD45RA/CCR7-associated differentiation trajectories comparable to those obtained using conventional manual magnetic separation. These results demonstrate that balancing magnetic force, hydrodynamic drag, and bead-to-cell ratio enables high-throughput T-cell negative selection compatible with subsequent CAR transduction and ex vivo expansion.

  • Compressed Spectrotemporal Imaging for Multiplexed Protein and Transcript Detection in Single Cells

    by Suyeon Shin, Hyo Geun Yun, Tae Won Kim, Sung Joo Lee, Yeon Su Kim, Ji Soo Kang, Jong-Min Lee, Ja Min Byun, Youngil Koh, Hyunsoo Cho, et al.

    High-dimensional single-cell profiling of proteins and transcripts is essential for understanding cellular heterogeneity, yet broadly accessible imaging approaches remain limited by insufficient multiplexing capacity and a lack of robust signal detection. Here, we introduce compression microscopy (CoM), a spectrotemporal multiplexing strategy that leverages the distinct photobleaching kinetics of conventional fluorophores. Photobleaching-based encoding is difficult to implement reproducibly in three-dimensional cell volumes, where signals can decay before the full volume is captured and out-of-focus excitation distorts intensity trajectories. In CoM, single cells containing target-specific DNA amplicons labeled with ratiometric fluorophore combinations are gently compressed into a thin, stable geometry, reducing the need for z-stack acquisition and minimizing out-of-focus excitation so that fluorophore decay trajectories can be captured reliably. By integrating photobleaching kinetics with ratiometric fluorescence encoding, CoM enables discrimination of up to 40 distinct fluorescence codes using standard widefield epifluorescence microscopy without specialized instrumentation. Applied to leukemia samples, CoM enables simultaneous in situ protein and transcript readouts at the single-cell level and identifies antigen-loss yet transcript-positive tumor cell variants that are difficult to resolve with conventional single-modality assays. CoM provides an accessible and scalable route to high-dimensional single-cell fluorescence profiling.

  • Frequency-Domain Photobleaching Denoising for Sensitive Extracellular Vesicle Detection Using Fluorescence Microscopy

    by Ji Soo Kang, Hyo Geun Yun, Suyeon Shin, So Hyun Hwang, Hee Sik Shin, Jinhwa Hong, Dong Ge Ra Mi Moon, Soon Young Lim, Hyeyeon Roh, Kyong Hwa Park, et al.

    Extracellular vesicles (EVs) are promising biomarkers for non-invasive cancer diagnostics, but their nanoscale size and correspondingly weak fluorescence signals make single-particle detection challenging without specialized, high-cost instrumentation. Here, we present a fast Fourier transform (FFT)-based computational imaging approach for EV analysis, termed EV-FFT, which repurposes fluorophore photobleaching into a frequency-domain signature for robust single-nanoparticle detection. EV-FFT transforms time-resolved fluorescence trajectories into Fourier space to suppress high-frequency stochastic noise while retaining the slow photobleaching component characteristic of nanoscale emitters. We validated EV-FFT using EVs from multiple cancer cell lines across eight protein markers, with signals showing strong concordance with ELISA measurements. In a proof-of-concept breast-cancer cohort, an eight-marker EV-FFT panel distinguished patients (stage II/IV) from healthy controls, achieving 97.2% sensitivity and 99.3% specificity at the Youden-index−optimized threshold (bootstrap 95% confidence intervals: 84.1−100% and 87.5−100% for sensitivity and specificity, respectively), outperforming conventional single-frame imaging (78.9%/91.1%). By improving sensitivity through computation rather than hardware complexity, EV-FFT enables accessible, high-precision EV immunophenotyping for cancer classification.

  • Magnetic smartphone microflow cytometry enables rapid CD4/CD8 T cell quantification

    by Hee Sik Shin, Sung Joo Lee, Jae In Kim, Jung Ho Kim, Jun Yong Choi, Su Jin Jeong, Sungyoung Choi

    We present MACC, a smartphone-based microflow cytometry platform for rapid, fully quantitative CD4+/CD8+ T-cell counting without fluorescent labels.

  • Horizontal Viscoelastic Focusing for Hyperspectral Microflow Cytometry

    by Hyo Geun Yun, Yoel Alonso Cadierno, Sang Min Ki, Hyun Ji Lee, Arrate Muñoz-Barrutia, Daniel Garcia-Gonzalez, Jong-Min Lee, Sungyoung Choi

  • Automation of 3D digital rolling circle amplification using a 3D-printed liquid handler

    by Suyeon Shin, Hyo Geun Yun, Haerim Chung, Hyunsoo Cho, Sungyoung Choi


  • Open Access

    Computational Hyperspectral Microflow Cytometry

    by Hyo Geun Yun, Yoel Alonso Cadierno, Tae Won Kim, Arrate Muñoz‐Barrutia, Daniel Garica‐Gonzalez, Sungyoung Choi

    Miniaturized flow cytometry has significant potential for portable applications, such as cell‐based diagnostics and the monitoring of therapeutic cell manufacturing, however, the performance of current techniques is often limited by the inability to resolve spectrally‐overlapping fluorescence labels. Here, the study presents a computational hyperspectral microflow cytometer (CHC) that enables accurate discrimination of spectrally‐overlapping fluorophores labeling single cells. CHC employs a dispersive optical element and an optimization algorithm to detect the full fluorescence emission spectrum from flowing cells, with a high spectral resolution of ≈3 nm in the range from 450 to 650 nm. CHC also includes a dedicated microfluidic device that ensures in‐focus imaging through viscoelastic sheathless focusing, thereby enhancing the accuracy and reliability of microflow cytometry analysis. The potential of CHC for analyzing T lymphocyte subpopulations and monitoring changes in cell composition during T cell expansion is demonstrated. Overall, CHC represents a major breakthrough in microflow cytometry and can facilitate its use for immune cell monitoring.


  • 3D Amplified Single-Cell RNA and Protein Imaging Identifies Oncogenic Transcript Subtypes in B-Cell Acute Lymphoblastic Leukemia

    by Suyeon Shin, Yoon-Jin Kim, Hyo Geun Yun, Haerim Chung, Hyunsoo Cho, Sungyoung Choi

    Simultaneous in situ detection of transcript and protein markers at the single-cell level is essential for gaining a better understanding of tumor heterogeneity and for predicting and monitoring treatment responses. However, the limited accessibility to advanced 3D imaging techniques has hindered their rapid implementation. Here, we present a 3D single-cell imaging technique, termed 3D digital rolling circle amplification (4DRCA), capable of the multiplexed and amplified simultaneous digital quantification of single-cell RNAs and proteins using standard fluorescence microscopy and off-the-shelf reagents. We generated spectrally distinguishable DNA amplicons from molecular markers through an integrative protocol combining single-cell RNA and protein assays and directly enumerated the amplicons by leveraging an open-source algorithm for 3D deconvolution with a custom-built automatic gating algorithm. With 4DRCA, we were able to simultaneously quantify surface protein markers and cytokine transcripts in T-lymphocytes. We also show that 4DRCA can distinguish BCR-ABL1 fusion transcript positive B-cell acute lymphoblastic leukemia cells with or without CD19 protein expression. The accessibility and extensibility of 4DRCA render it broadly applicable to other cell-based diagnostic workflows, enabling sensitive and accurate single-cell RNA and protein profiling.


  • Enhanced functionalities of immune cells separated by a microfluidic lattice: assessment based on holotomography

    by Mahn Jae Lee, Byungyeon Kim, Dohyeon Lee, Geon Kim, Yoonjae Chung, Hee Sik Shin, Sungyoung Choi, YongKeun Park

    The isolation of white blood cells (WBCs) from whole blood constitutes a pivotal process for immunological studies, diagnosis of hematologic disorders, and the facilitation of immunotherapy. Despite the ubiquity of density gradient centrifugation in WBC isolation, its influence on WBC functionality remains inadequately understood. This research employs holotomography to explore the effects of two distinct WBC separation techniques, namely conventional centrifugation and microfluidic separation, on the functionality of the isolated cells. We utilize three-dimensional refractive index distribution and time-lapse dynamics to analyze individual WBCs in-depth, focusing on their morphology, motility, and phagocytic capabilities. Our observations highlight that centrifugal processes negatively impact WBC motility and phagocytic capacity, whereas microfluidic separation yields a more favorable outcome in preserving WBC functionality. These findings emphasize the potential of microfluidic separation techniques as a viable alternative to traditional centrifugation for WBC isolation, potentially enabling more precise analyses in immunology research and improving the accuracy of hematologic disorder diagnoses.


  • Open Access

    3D amplified single-cell RNA and protein imaging identifies oncogenic transcript subtypes in B cell acute lymphoblastic leukemia

    by Sungyoung Choi, Suyeon Shin, Yoon-Jin Kim, Haerim Chung, Hyunsoo Cho, Hyo Geun Yun

    Simultaneous in situ detection of transcript and protein markers at single-cell level is essential for gaining a better understanding of tumor heterogeneity and for predicting and monitoring treatment responses. However, the limited accessibility to advanced 3D imaging techniques has hindered its rapid implementation. Here, we present a 3D single-cell imaging technique, termed 3D digital rolling circle amplification (4DRCA), capable of the multiplexed and amplified simultaneous digital quantification of single-cell RNAs and proteins using standard fluorescence microscopy and off-the-shelf reagents. We generated spatially and spectrally distinguishable DNA amplicons from molecular markers through an integrative protocol combining single-cell RNA and protein assays, and directly enumerated the amplicons by leveraging an open-source algorithm for 3D deconvolution with a custom-built automatic gating algorithm. With 4DRCA, we were able to simultaneously quantify surface protein markers and cytokine transcripts in T lymphocytes. We also show that 4DRCA can distinguish BCR-ABL1 fusion transcript positive B-cell acute lymphoblastic leukemia cells with or without CD19 protein expression. The accessibility and extensibility of 4DRCA render it broadly applicable to other cell-based diagnostic workflows, enabling sensitive and accurate single-cell RNA and protein profiling.