Victor Rodriguez-Lopez
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Victor Rodriguez-Lopez has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
Carlos Dorronsoro
Institute of Optics, Spanish National Research Council (IO-CSIC), Madrid, Spain
4 shared publications- Carlos Dorronsoro
Laboratory of Visual Optics and Biophotonics, Instituto de Optica, Consejo Superior de Investigaciones Cientificas, Serrano 121, 28006 Madrid, Spain
4 shared publications - Johannes Burge
Department of Psychology, University of Pennsylvania, Philadelphia, PA, USA
4 shared publications Alfonso Hernandez-Poyatos
Spanish Natl Res Council IO CSIC, Inst Opt, IO CSIC, Serrano 121, Madrid E-28006, Spain
2 shared publicationsSusana Marcos
Institute of Optics, Spanish National Research Council (IO-CSIC), Madrid, Spain; Center for Visual Science, The Institute of Optics, Flaum Eye Institute, University of Rochester, NY, USA
2 shared publications- Alberto de Castro
Instituto de Óptica “Daza de Valdés,” Consejo Superior de Investigaciones Científicas, Madrid, Spain
1 shared publication
Latest Publications
- Open Access
- 1 May 2026
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Investigative Ophthalmology & Visual Science
- Vol. 67 (5) , 6
A Common Prescription Lens Correction Causes Motion Illusions in the Presbyopic and General Populations
Monovision is a common correction for presbyopia that focuses one eye at far distances and the other at near distances, resulting in a difference in blur between the eyes. Because blur increases the speed of visual processing by a few milliseconds, these optical conditions can induce dramatic misperceptions of the distances and three-dimensional directions of moving objects. To date, the illusion has been demonstrated only in individuals without presbyopia. We analyze both the induced processing speed differences and the visibility of the resulting illusions in presbyopic (n = 17, 22.2 ± 5.0 years) and non-presbyopic (n = 36, 54.4 ± 5.9 years) populations, with proportions approximately matching those in the general population. Participants viewed two horizontally moving strips of bars on an autostereoscopic display with interocular blur and light-level differences, and reported which strip appeared closer in depth. Interocular delay and an illusion visibility index-the ratio of interocular delay and the detection threshold-were computed for each participant in each condition. Delays were highly consistent in both the presbyopic and general populations. Interocular differences in optical blur and light-level caused highly consistent interocular differences in processing speed in all participants, although they created visible (suprathreshold) illusions in only a subset of participants. This subset, however, included individuals with processing delays that were many times larger than the detection threshold. Such individuals are likely to be afflicted by large, highly visible illusions in real-world conditions. Methods for identifying high-risk individuals and for reducing or eliminating the illusions are discussed.
- 1 May 2026
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Investigative Ophthalmology & Visual Science
- Vol. 67 (5) , 6
Open AccessA Common Prescription Lens Correction Causes Motion Illusions in the Presbyopic and General Populations
Monovision is a common correction for presbyopia that focuses one eye at far distances and the other at near distances, resulting in a difference in blur between the eyes. Because blur increases the speed of visual processing by a few milliseconds, these optical conditions can induce dramatic misperceptions of the distances and three-dimensional directions of moving objects. To date, the illusion has been demonstrated only in individuals without presbyopia. We analyze both the induced processing speed differences and the visibility of the resulting illusions in presbyopic (n = 17, 22.2 ± 5.0 years) and non-presbyopic (n = 36, 54.4 ± 5.9 years) populations, with proportions approximately matching those in the general population. Participants viewed two horizontally moving strips of bars on an autostereoscopic display with interocular blur and light-level differences, and reported which strip appeared closer in depth. Interocular delay and an illusion visibility index-the ratio of interocular delay and the detection threshold-were computed for each participant in each condition. Delays were highly consistent in both the presbyopic and general populations. Interocular differences in optical blur and light-level caused highly consistent interocular differences in processing speed in all participants, although they created visible (suprathreshold) illusions in only a subset of participants. This subset, however, included individuals with processing delays that were many times larger than the detection threshold. Such individuals are likely to be afflicted by large, highly visible illusions in real-world conditions. Methods for identifying high-risk individuals and for reducing or eliminating the illusions are discussed.
- Open Access
Monovision-induced motion illusions in presbyopic and non-presbyopic populations
Monovision is a common correction for presbyopia that focuses one eye at far distances and the other at near distances, resulting in an interocular difference in blur between the eyes. Because blur increases the speed of visual processing by a few milliseconds, these optical conditions can induce dramatic misperceptions of the distances and 3D directions of moving objects. To date, however, the illusion has been demonstrated in only non-presbyopic individuals. We analyze the prevalence of both the processing speed differences and the visibility of the resulting illusions in the presbyopic and general populations.17 presbyopes (54.4±5.9years) and 36 non-presbyopes (22.2±5.0years) participated. The proportions of these participant populations approximately match their proportions in the general population. Two strips of horizontally moving bars were presented on an autostereoscopic display with interocular blur and light-level differences. The task was to report which strip appeared closer in depth. Blur- and light-level differences caused illusions that are respectively known as the reverse and classic Pulfrich effects. Interocular delay and an illusion visibility index—the ratio of interocular delay and the detection threshold—were obtained from each participant for both blur and light-level differences between the eyes. Blur- and light-level differences cause highly significant changes in processing speed at the individual and group levels. (The two populations were statistically indistinguishable in their susceptibility to stimulus-induced processing speed differences.) The reverse and classic Pulfrich effects occurred in 94% and in 96%, respectively, of the general participant population. The visibility index showed that the processing speed discrepancy exceeded the detection threshold in a smaller number of participants—30% and 43%, respectively. Interocular differences in optical blur reliably cause interocular differences in processing speed across presbyopic and non-presbyopic populations, although they create visible (suprathreshold) illusions in only a subset of participants. However, this subset included individuals with processing delays that were many times larger than the detection threshold. These latter participants are likely to be afflicted by large, highly visible illusions in real-world conditions. Methods for reducing or eliminating these illusions are discussed. +
Open AccessMonovision-induced motion illusions in presbyopic and non-presbyopic populations
Monovision is a common correction for presbyopia that focuses one eye at far distances and the other at near distances, resulting in an interocular difference in blur between the eyes. Because blur increases the speed of visual processing by a few milliseconds, these optical conditions can induce dramatic misperceptions of the distances and 3D directions of moving objects. To date, however, the illusion has been demonstrated in only non-presbyopic individuals. We analyze the prevalence of both the processing speed differences and the visibility of the resulting illusions in the presbyopic and general populations.17 presbyopes (54.4±5.9years) and 36 non-presbyopes (22.2±5.0years) participated. The proportions of these participant populations approximately match their proportions in the general population. Two strips of horizontally moving bars were presented on an autostereoscopic display with interocular blur and light-level differences. The task was to report which strip appeared closer in depth. Blur- and light-level differences caused illusions that are respectively known as the reverse and classic Pulfrich effects. Interocular delay and an illusion visibility index—the ratio of interocular delay and the detection threshold—were obtained from each participant for both blur and light-level differences between the eyes. Blur- and light-level differences cause highly significant changes in processing speed at the individual and group levels. (The two populations were statistically indistinguishable in their susceptibility to stimulus-induced processing speed differences.) The reverse and classic Pulfrich effects occurred in 94% and in 96%, respectively, of the general participant population. The visibility index showed that the processing speed discrepancy exceeded the detection threshold in a smaller number of participants—30% and 43%, respectively. Interocular differences in optical blur reliably cause interocular differences in processing speed across presbyopic and non-presbyopic populations, although they create visible (suprathreshold) illusions in only a subset of participants. However, this subset included individuals with processing delays that were many times larger than the detection threshold. These latter participants are likely to be afflicted by large, highly visible illusions in real-world conditions. Methods for reducing or eliminating these illusions are discussed. +
- Open Access
- 4 August 2025
- Published by Frontiers Media SA in Frontiers in Medicine
- Vol. 12, 1504560
Differences in perceived chromatic aberration between emmetropic and myopic eyes using adaptive optics
Introduction: The study of polychromatic visual perception is challenging due to the number of entangled factors involved in the process, from the cues within visual information from the outside world, to the ocular optics, the retinal properties, and neural adaptation processes in the brain.Methods: In this study, we used an adaptive optics (AO)- based polychromatic visual simulator to investigate the perception of combined optical cues and its dependence on refractive error. Subjective best focus was obtained as the average of 3 repeated measurements for (1) polychromatic and five monochromatic wavelengths in the visible (450–670 nm); (2) three different visual stimuli (conventional binary sunburst, natural outdoor image, natural indoor image); and (3) under natural aberrations (no-AO) and corrected aberrations (AO) conditions. Repeatability was determined as the standard deviation across repetitions. Chromatic difference of focus (CDF) was calculated for Green-Blue (G-Blue, 550–470 nm) and Green-Red (G-Red, 550–700 nm). Longitudinal chromatic aberration (LCA) was estimated using a polynomial regression fit of the best subjective focus curves as a function of the wavelength. Nine young adults (28 ± 6 years) with different refractive profiles (6 myopic and 3 emmetropic) participated in this study.Results: CDF showed different trends in the G-Red and the G-Blue regions, especially for the binary stimulus and after AO-correction of aberrations. However, in the myopic group, CDF was similar in absolute value for G-Blue and G-Red (0.61 ± 0.34 and 0.73 ± 0.58, respectively, p > 0.05 Mann-Whitney U test), whereas, in the emmetropic group, the chromatic difference was greater for G-Blue than for G-Red (0.58 ± 0.32 D and 0.22 ± 0.38 D, respectively, p < 0.05 Mann-Whitney U test). There was no effect of correcting natural aberrations. LCA does not vary with refractive error.Discussion: Overall, the results of this study suggest that the refractive profile may influence how visual information with specific chromatic properties is perceived and processed, potentially shaping visual mechanisms involved in chromatic defocus perception.
- 4 August 2025
- Published by Frontiers Media SA in Frontiers in Medicine
- Vol. 12, 1504560
Open AccessDifferences in perceived chromatic aberration between emmetropic and myopic eyes using adaptive optics
Introduction: The study of polychromatic visual perception is challenging due to the number of entangled factors involved in the process, from the cues within visual information from the outside world, to the ocular optics, the retinal properties, and neural adaptation processes in the brain.Methods: In this study, we used an adaptive optics (AO)- based polychromatic visual simulator to investigate the perception of combined optical cues and its dependence on refractive error. Subjective best focus was obtained as the average of 3 repeated measurements for (1) polychromatic and five monochromatic wavelengths in the visible (450–670 nm); (2) three different visual stimuli (conventional binary sunburst, natural outdoor image, natural indoor image); and (3) under natural aberrations (no-AO) and corrected aberrations (AO) conditions. Repeatability was determined as the standard deviation across repetitions. Chromatic difference of focus (CDF) was calculated for Green-Blue (G-Blue, 550–470 nm) and Green-Red (G-Red, 550–700 nm). Longitudinal chromatic aberration (LCA) was estimated using a polynomial regression fit of the best subjective focus curves as a function of the wavelength. Nine young adults (28 ± 6 years) with different refractive profiles (6 myopic and 3 emmetropic) participated in this study.Results: CDF showed different trends in the G-Red and the G-Blue regions, especially for the binary stimulus and after AO-correction of aberrations. However, in the myopic group, CDF was similar in absolute value for G-Blue and G-Red (0.61 ± 0.34 and 0.73 ± 0.58, respectively, p > 0.05 Mann-Whitney U test), whereas, in the emmetropic group, the chromatic difference was greater for G-Blue than for G-Red (0.58 ± 0.32 D and 0.22 ± 0.38 D, respectively, p < 0.05 Mann-Whitney U test). There was no effect of correcting natural aberrations. LCA does not vary with refractive error.Discussion: Overall, the results of this study suggest that the refractive profile may influence how visual information with specific chromatic properties is perceived and processed, potentially shaping visual mechanisms involved in chromatic defocus perception.
- Open Access
- 31 May 2025
- Published by Elsevier in Contact Lens and Anterior Eye
- Vol. 48 (5) , 102445
In vivo assessment of multifocal contact lens fitting using anterior segment optical coherence tomography
- 31 May 2025
- Published by Elsevier in Contact Lens and Anterior Eye
- Vol. 48 (5) , 102445
Open AccessIn vivo assessment of multifocal contact lens fitting using anterior segment optical coherence tomography
- Open Access
- 1 April 2025
- Published by Wiley in Optometry and Vision Science
- Vol. 102 (4) , 196-203
A metric‐based image‐formation model explains the improvement in subjective refraction using temporal defocus waves
SIGNIFICANCE: Direct subjective refraction (DSR) is a novel method for refractive error measurements that uses temporal changes in defocus and a flicker minimization task. The computational models developed here are a framework for improving this clinical method. PURPOSE: This study aimed to model the measurement of refractive error with the DSR method, which uses rapid changes in optical power and a bichromatic (red/blue) stimulus. METHODS: The polychromatic point spread function of the eye was used to simulate the retinal image projected in DSR method, and an image quality (IQ) metric was defined based on the spatial frequencies of the retinal image. Three tasks were modeled: blur minimization (BM), monochromatic flicker minimization (MFM), and polychromatic flicker minimization or DSR. A metric was defined for each task and studied through focus in a ±3‐D range. Whereas BM was modeled using only the IQ of the projected images, MFM and DSR metrics were a function of the IQ of the average retinal image and a metric to quantify the similarity (flicker) in the image. The width of the through‐focus peak was used to compare between tasks, and different values of pupil size and spherical aberration were studied. RESULTS: The through‐focus 90% peak width was 0.48, 0.16, and 0.19 D for BM, MFM, and DSR tasks, respectively, which agreed well with previous experimental data. The 90% peak width increased for small pupils and with increasing values of spherical aberration in BM and MFM, but it remained relatively constant in DSR model. CONCLUSIONS: The developed models explained previous experimental findings that reported a higher repeatability of the DSR compared with the traditional refraction method.
- 1 April 2025
- Published by Wiley in Optometry and Vision Science
- Vol. 102 (4) , 196-203
Open AccessA metric‐based image‐formation model explains the improvement in subjective refraction using temporal defocus waves
SIGNIFICANCE: Direct subjective refraction (DSR) is a novel method for refractive error measurements that uses temporal changes in defocus and a flicker minimization task. The computational models developed here are a framework for improving this clinical method. PURPOSE: This study aimed to model the measurement of refractive error with the DSR method, which uses rapid changes in optical power and a bichromatic (red/blue) stimulus. METHODS: The polychromatic point spread function of the eye was used to simulate the retinal image projected in DSR method, and an image quality (IQ) metric was defined based on the spatial frequencies of the retinal image. Three tasks were modeled: blur minimization (BM), monochromatic flicker minimization (MFM), and polychromatic flicker minimization or DSR. A metric was defined for each task and studied through focus in a ±3‐D range. Whereas BM was modeled using only the IQ of the projected images, MFM and DSR metrics were a function of the IQ of the average retinal image and a metric to quantify the similarity (flicker) in the image. The width of the through‐focus peak was used to compare between tasks, and different values of pupil size and spherical aberration were studied. RESULTS: The through‐focus 90% peak width was 0.48, 0.16, and 0.19 D for BM, MFM, and DSR tasks, respectively, which agreed well with previous experimental data. The 90% peak width increased for small pupils and with increasing values of spherical aberration in BM and MFM, but it remained relatively constant in DSR model. CONCLUSIONS: The developed models explained previous experimental findings that reported a higher repeatability of the DSR compared with the traditional refraction method.
- Open Access
- 3 March 2025
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Journal of Vision
- Vol. 25 (3) , 7
Decreases in overall light level increase the severity of the reverse Pulfrich effect
The Pulfrich effect is an illusion characterized by the misperception of the depth and 3D direction of moving objects. Interocular luminance differences cause the classic Pulfrich effect; the darker image is processed more slowly. Interocular blur differences cause the reverse Pulfrich effect; the blurrier image is processed more quickly. A common correction for presbyopia-monovision-intentionally induces the optical conditions that cause the reverse Pulfrich effect. The effect sizes, and the fact that tens of millions of people wear these corrections every day, raise concerns about public safety. However, although the impact of overall light level (e.g., nighttime vs. daytime) on the classic Pulfrich effect has been well characterized, its impact on the reverse Pulfrich effect is unknown. Here, using a custom binocular 4f tunable lens optical system that allows the decoupling of retinal illuminance and retinal blur, we report how the classic and reverse Pulfrich effects scale with overall light level. Both effects increase logarithmically with decreases in light level. These results motivate a characterization of how light level interacts with other optical factors (e.g., higher-order aberrations) that are likely to impact the reverse Pulfrich effect and, hence, the perceptual consequences of monovision corrections.
- 3 March 2025
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Journal of Vision
- Vol. 25 (3) , 7
Open AccessDecreases in overall light level increase the severity of the reverse Pulfrich effect
The Pulfrich effect is an illusion characterized by the misperception of the depth and 3D direction of moving objects. Interocular luminance differences cause the classic Pulfrich effect; the darker image is processed more slowly. Interocular blur differences cause the reverse Pulfrich effect; the blurrier image is processed more quickly. A common correction for presbyopia-monovision-intentionally induces the optical conditions that cause the reverse Pulfrich effect. The effect sizes, and the fact that tens of millions of people wear these corrections every day, raise concerns about public safety. However, although the impact of overall light level (e.g., nighttime vs. daytime) on the classic Pulfrich effect has been well characterized, its impact on the reverse Pulfrich effect is unknown. Here, using a custom binocular 4f tunable lens optical system that allows the decoupling of retinal illuminance and retinal blur, we report how the classic and reverse Pulfrich effects scale with overall light level. Both effects increase logarithmically with decreases in light level. These results motivate a characterization of how light level interacts with other optical factors (e.g., higher-order aberrations) that are likely to impact the reverse Pulfrich effect and, hence, the perceptual consequences of monovision corrections.
- Open Access
The impact of overall light-level on the reverse Pulfrich effect
The Pulfrich Effect is an illusion characterized by the misperception of the depth and 3D direction of moving objects. Interocular luminance differences cause the Classic Pulfrich effect; the darker image is processed more slowly. Interocular blur differences cause the Reverse Pulfrich effect; the blurrier image is processed more quickly. A common correction for presbyopia—monovision—intentionally induces the optical conditions that cause the Reverse Pulfrich Effect. The effect sizes, and the fact that tens of millions of people wear these corrections every day, raise concerns about public safety. However, although the impact of overall light-level (e.g., nighttime vs. daytime) on the Classic Pulfrich effect has been well-characterized, its impact on the Reverse Pulfrich effect is unknown. Here, using a custom binocular 4f tunable lens optical system that allows the decoupling of retinal illuminance and retinal blur, we report how the Classic and Reverse Pulfrich effects scale with overall light-level. Both effects increase logarithmically with decreases in light-level. These results motivate a characterization of how light level interacts with other optical factors (e.g., higher-order aberrations) that are likely to impact the Reverse Pulfrich effect, and hence the perceptual consequences of monovision corrections. Commercial disclosure: V. Rodriguez Lopez: None; B. Chin: None; J. Burge: None.
Open AccessThe impact of overall light-level on the reverse Pulfrich effect
The Pulfrich Effect is an illusion characterized by the misperception of the depth and 3D direction of moving objects. Interocular luminance differences cause the Classic Pulfrich effect; the darker image is processed more slowly. Interocular blur differences cause the Reverse Pulfrich effect; the blurrier image is processed more quickly. A common correction for presbyopia—monovision—intentionally induces the optical conditions that cause the Reverse Pulfrich Effect. The effect sizes, and the fact that tens of millions of people wear these corrections every day, raise concerns about public safety. However, although the impact of overall light-level (e.g., nighttime vs. daytime) on the Classic Pulfrich effect has been well-characterized, its impact on the Reverse Pulfrich effect is unknown. Here, using a custom binocular 4f tunable lens optical system that allows the decoupling of retinal illuminance and retinal blur, we report how the Classic and Reverse Pulfrich effects scale with overall light-level. Both effects increase logarithmically with decreases in light-level. These results motivate a characterization of how light level interacts with other optical factors (e.g., higher-order aberrations) that are likely to impact the Reverse Pulfrich effect, and hence the perceptual consequences of monovision corrections. Commercial disclosure: V. Rodriguez Lopez: None; B. Chin: None; J. Burge: None.
- 26 June 2023
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 14 (7) , 3654-3670
Spatiotemporal defocus sensitivity function of the human visual system
Tunable lenses make it possible to measure visual sensitivity to rapid changes in optical power, surpassing the limits imposed by mechanical elements. Using a tunable lens system, we measured, for the first time, the spatiotemporal defocus sensitivity function (STDSF), and the limits of human defocus perception. Specifically, we measured defocus sensitivity using a QUEST adaptive psychophysical procedure for different stimuli (Gabor patches of different spatial frequencies, natural images, and edges) and we developed descriptive models of defocus perception. For Gabor patches, we found on average (across seven subjects) that the maximum sensitivity to defocus is 0.22 D at 14 cpd and 10 Hz, and that the upper limits of sensitivity are 40 cpd and 40 Hz. Our results suggest that accommodation remains fixed while performing the defocus flicker-detection task. These results have implications for new technologies whose working principles make use of fast changes to defocus.
- 26 June 2023
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 14 (7) , 3654-3670
Spatiotemporal defocus sensitivity function of the human visual system
Tunable lenses make it possible to measure visual sensitivity to rapid changes in optical power, surpassing the limits imposed by mechanical elements. Using a tunable lens system, we measured, for the first time, the spatiotemporal defocus sensitivity function (STDSF), and the limits of human defocus perception. Specifically, we measured defocus sensitivity using a QUEST adaptive psychophysical procedure for different stimuli (Gabor patches of different spatial frequencies, natural images, and edges) and we developed descriptive models of defocus perception. For Gabor patches, we found on average (across seven subjects) that the maximum sensitivity to defocus is 0.22 D at 14 cpd and 10 Hz, and that the upper limits of sensitivity are 40 cpd and 40 Hz. Our results suggest that accommodation remains fixed while performing the defocus flicker-detection task. These results have implications for new technologies whose working principles make use of fast changes to defocus.
- 26 June 2023
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 14 (7) , 3671-3688
Defocus flicker of chromatic stimuli deactivates accommodation
Tunable lenses, optical elements able to change their optical power within milliseconds, constitute an emerging technology increasingly used in ophthalmic applications. In this study, 25 subjects looked through tunable lenses at a chromatic stimulus to evaluate the perceptual response of the human visual system to periodic changes in defocus of 0.25D of amplitude and 15 Hz of temporal frequency. These defocus changes produce flicker and chromatic distortions that change with the overall level of defocus. The task in this study was to minimize the flicker by varying the average optical power, and it was performed for different myopic and hyperopic starting points. Subjects also performed a blur-minimization task in a black-and-white stimulus of the same geometry. The flicker-minimization task is more repeatable than the blur-minimization task (standard deviations ±0.17D and ±0.49D). The time per repetition of the flicker-minimization task is only 38s. Cycloplegia severely affects the blur-minimization, but not the flicker-minimization task, confirming that defocus flicker deactivates the accommodative system. This discovery can be used to develop new methods for measuring the refractive error of the eye that does not require supervision and can potentially improve existing subjective methods in terms of accuracy, precision, and measurement time.
- 26 June 2023
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 14 (7) , 3671-3688
Defocus flicker of chromatic stimuli deactivates accommodation
Tunable lenses, optical elements able to change their optical power within milliseconds, constitute an emerging technology increasingly used in ophthalmic applications. In this study, 25 subjects looked through tunable lenses at a chromatic stimulus to evaluate the perceptual response of the human visual system to periodic changes in defocus of 0.25D of amplitude and 15 Hz of temporal frequency. These defocus changes produce flicker and chromatic distortions that change with the overall level of defocus. The task in this study was to minimize the flicker by varying the average optical power, and it was performed for different myopic and hyperopic starting points. Subjects also performed a blur-minimization task in a black-and-white stimulus of the same geometry. The flicker-minimization task is more repeatable than the blur-minimization task (standard deviations ±0.17D and ±0.49D). The time per repetition of the flicker-minimization task is only 38s. Cycloplegia severely affects the blur-minimization, but not the flicker-minimization task, confirming that defocus flicker deactivates the accommodative system. This discovery can be used to develop new methods for measuring the refractive error of the eye that does not require supervision and can potentially improve existing subjective methods in terms of accuracy, precision, and measurement time.
- Open Access
- 23 June 2023
- Published by Springer Nature in BMC Ophthalmology
- Vol. 23 (1) , 1-13
Case report of the evidence of a spontaneous Reverse Pulfrich effect in monovision after cataract surgery
Background: Cataracts affect the optics of the eye in terms of absorption, blur, and scattering. When cataracts are unilateral, they cause differences between the eyes that can produce visual discomfort and harm binocular vision. These interocular differences can also induce differences in the processing speed of the eyes that may cause a spontaneous Pulfrich effect, a visual illusion provoking important depth misperceptions. Interocular differences in light level, like those present in unilateral cataracts, can cause the Classic Pulfrich effect, and interocular differences in blur, like those present in monovision, a common correction for presbyopia, can cause the Reverse Pulfrich effect. The visual system may be able to adapt, or not, to the new optical condition, depending on the degree of the cataract and the magnitude of the monovision correction. Case presentation: Here, we report a unique case of a 45-year-old patient that underwent unilateral cataract surgery resulting in a monovision correction of 2.5 diopters (D): left eye emmetropic after the surgery compensated with a monofocal intraocular lens and right eye myopic with a spherical equivalent of -2.50 D. This patient suffered severe symptoms in binocular vision, which can be explained by a spontaneous Pulfrich effect (a delay measured of 4.82 ms, that could be eliminated with a 0.19 optical density filter). After removing the monovision with clear lens extraction in the second eye, symptoms disappeared. We demonstrate that, at least in this patient, both Classic and Reverse Pulfrich effects coexist after unilateral cataract surgery and that can be readapted by reverting the interocular differences. Besides, we report that the adaptation/readaptation process to the Reverse Pulfrich effect happens in a timeframe of weeks, as opposed to the Classic Pulfrich effect, known to have timeframes of days. Additionally, we used the illusion measured in the laboratory to quantify the relevance of the spontaneous Pulfrich effect in different visual scenarios and tasks, using geometrical models and optic flow algorithms. Conclusions: Measuring the different versions of the Pulfrich effect might help to understand the visual discomfort reported by many patients after cataract surgery or with monovision and could guide compensation or intervention strategies.
- 23 June 2023
- Published by Springer Nature in BMC Ophthalmology
- Vol. 23 (1) , 1-13
Open AccessCase report of the evidence of a spontaneous Reverse Pulfrich effect in monovision after cataract surgery
Background: Cataracts affect the optics of the eye in terms of absorption, blur, and scattering. When cataracts are unilateral, they cause differences between the eyes that can produce visual discomfort and harm binocular vision. These interocular differences can also induce differences in the processing speed of the eyes that may cause a spontaneous Pulfrich effect, a visual illusion provoking important depth misperceptions. Interocular differences in light level, like those present in unilateral cataracts, can cause the Classic Pulfrich effect, and interocular differences in blur, like those present in monovision, a common correction for presbyopia, can cause the Reverse Pulfrich effect. The visual system may be able to adapt, or not, to the new optical condition, depending on the degree of the cataract and the magnitude of the monovision correction. Case presentation: Here, we report a unique case of a 45-year-old patient that underwent unilateral cataract surgery resulting in a monovision correction of 2.5 diopters (D): left eye emmetropic after the surgery compensated with a monofocal intraocular lens and right eye myopic with a spherical equivalent of -2.50 D. This patient suffered severe symptoms in binocular vision, which can be explained by a spontaneous Pulfrich effect (a delay measured of 4.82 ms, that could be eliminated with a 0.19 optical density filter). After removing the monovision with clear lens extraction in the second eye, symptoms disappeared. We demonstrate that, at least in this patient, both Classic and Reverse Pulfrich effects coexist after unilateral cataract surgery and that can be readapted by reverting the interocular differences. Besides, we report that the adaptation/readaptation process to the Reverse Pulfrich effect happens in a timeframe of weeks, as opposed to the Classic Pulfrich effect, known to have timeframes of days. Additionally, we used the illusion measured in the laboratory to quantify the relevance of the spontaneous Pulfrich effect in different visual scenarios and tasks, using geometrical models and optic flow algorithms. Conclusions: Measuring the different versions of the Pulfrich effect might help to understand the visual discomfort reported by many patients after cataract surgery or with monovision and could guide compensation or intervention strategies.