Alexander Doyle
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Alexander Doyle has a total of 33 co-authors. Here are the top co-authors by number of shared publications:
- Peter Young
P Young, MD, MBChB, Consultant in Anaesthesia and Critical Care, Department of Anaesthesia and Critical Care, Queen Elizabeth Hospital NHS Trust, Critical Care, King's Lynn, UK
3 shared publications Aimen Hassani
Mid Essex Hospital Trust
2 shared publications- Joseph Carter
Department of Anaesthesia and Critical Care, Queen Elizabeth Hospital, Kings Lynn, Norfolk, PE30 4ET, UK
2 shared publications - Mark Blunt
Department of Anaesthesia and Critical Care, Queen Elizabeth Hospital, Kings Lynn, Norfolk, PE30 4ET, UK
2 shared publications Philippa Stennings-Smith
Mid Essex Hospital Trust
2 shared publicationsPrasanna Tilakaratna
Mid Essex Hospital Trust
2 shared publications
Latest Publications
- Open Access
- 2 November 2019
- Published by Springer Nature in Research Square
Target controlled infusion pump occlusion alarm response times and their clinical implications: A bench-top and simulation study
The authors have withdrawn the journal submission associated with this preprint and requested that the preprint also be withdrawn
- 2 November 2019
- Published by Springer Nature in Research Square
Open AccessTarget controlled infusion pump occlusion alarm response times and their clinical implications: A bench-top and simulation study
The authors have withdrawn the journal submission associated with this preprint and requested that the preprint also be withdrawn
- Open Access
- 3 January 2019
- Published by Springer Nature in Research Square
Target controlled infusion pump occlusion alarm response times and their clinical implications: A bench-top and simulation study
Background: There is a time-delay between obstruction of the infusion apparatus and the onset of the occlusion alarm on both the Alaris PK and Braun Perfusor Space target controlled infusion (TCI) pumps. Depending on the extent of this time-delay, it is possible that drug effect-site concentrations could decrement below minimally effective levels during this period, potentially exposing patients to the risk of accidental awareness under general anaesthesia. Methods: In a bench-top experiment, we recorded the alarm response time of both devices after intentional obstruction using a standardised protocol. We then computer-simulated a series of clinically relevant TCIs to determine if the effect-site concentration of propofol or remifentanil could decrement below 2 ug.mL-1 or 3 ng.mL-1 before the alarm was predicted to sound. Results: The alarm response time of both devices was longer at higher alarm level settings and slower infusion rates, but different between brands at equivalent alarm level settings (p < 0.0001 for all comparisons). The simulations revealed that the drug effect-site concentrations of propofol and remifentanil could decrement below minimally effective levels within the alarm response time of either device, when Schnider or Minto effect kinetics utilising slow infusion rates were combined with high alarm level settings. Conclusions: Our study suggests that, under certain conditions of use, the design and performance of the occlusion alarm on the Alaris PK and Braun Perfusor Space TCI pumps can potentially permit inadequate drug delivery during TCI anaesthesia. We believe our findings should serve as a warning to clinicians to be wary of utilising slow infusion rates in combination with high alarm level settings and propose that clinicians mitigate against this risk by choosing alarm level settings based upon the baseline alarm performance in order to minimise any redundancy in the alarm response time. Keywords: Infusion Pumps, Patient Safety, Anaesthetics i.v., Propofol
- 3 January 2019
- Published by Springer Nature in Research Square
Open AccessTarget controlled infusion pump occlusion alarm response times and their clinical implications: A bench-top and simulation study
Background: There is a time-delay between obstruction of the infusion apparatus and the onset of the occlusion alarm on both the Alaris PK and Braun Perfusor Space target controlled infusion (TCI) pumps. Depending on the extent of this time-delay, it is possible that drug effect-site concentrations could decrement below minimally effective levels during this period, potentially exposing patients to the risk of accidental awareness under general anaesthesia. Methods: In a bench-top experiment, we recorded the alarm response time of both devices after intentional obstruction using a standardised protocol. We then computer-simulated a series of clinically relevant TCIs to determine if the effect-site concentration of propofol or remifentanil could decrement below 2 ug.mL-1 or 3 ng.mL-1 before the alarm was predicted to sound. Results: The alarm response time of both devices was longer at higher alarm level settings and slower infusion rates, but different between brands at equivalent alarm level settings (p < 0.0001 for all comparisons). The simulations revealed that the drug effect-site concentrations of propofol and remifentanil could decrement below minimally effective levels within the alarm response time of either device, when Schnider or Minto effect kinetics utilising slow infusion rates were combined with high alarm level settings. Conclusions: Our study suggests that, under certain conditions of use, the design and performance of the occlusion alarm on the Alaris PK and Braun Perfusor Space TCI pumps can potentially permit inadequate drug delivery during TCI anaesthesia. We believe our findings should serve as a warning to clinicians to be wary of utilising slow infusion rates in combination with high alarm level settings and propose that clinicians mitigate against this risk by choosing alarm level settings based upon the baseline alarm performance in order to minimise any redundancy in the alarm response time. Keywords: Infusion Pumps, Patient Safety, Anaesthetics i.v., Propofol
- 1 December 2016
- Published by Elsevier in Journal of Critical Care
- Vol. 36, 8-12
Preoxygenation and apneic oxygenation using Transnasal Humidified Rapid-Insufflation Ventilatory Exchange for emergency intubation
- 1 December 2016
- Published by Elsevier in Journal of Critical Care
- Vol. 36, 8-12
Preoxygenation and apneic oxygenation using Transnasal Humidified Rapid-Insufflation Ventilatory Exchange for emergency intubation
- 31 December 2011
- Published by Elsevier in Journal of Critical Care
- Vol. 26 (6) , 637.e1-637.e4
A change in humidification system can eliminate endotracheal tube occlusion
- 31 December 2011
- Published by Elsevier in Journal of Critical Care
- Vol. 26 (6) , 637.e1-637.e4
A change in humidification system can eliminate endotracheal tube occlusion
- Open Access
- 30 March 2011
- Published by Springer Nature in BMC Research Notes
- Vol. 4 (1) , 92
The incidence of ventilator-associated pneumonia using the PneuX System with or without elective endotracheal tube exchange: A pilot study
The PneuX System is a novel endotracheal tube and tracheal seal monitor, which has been designed to minimise the aspiration of oropharyngeal secretions. We aimed to determine the incidence of ventilator-associated pneumonia (VAP) in patients who were intubated with the PneuX System and to establish whether intermittent subglottic secretion drainage could be performed reliably and safely using the PneuX System.
- 30 March 2011
- Published by Springer Nature in BMC Research Notes
- Vol. 4 (1) , 92
Open AccessThe incidence of ventilator-associated pneumonia using the PneuX System with or without elective endotracheal tube exchange: A pilot study
The PneuX System is a novel endotracheal tube and tracheal seal monitor, which has been designed to minimise the aspiration of oropharyngeal secretions. We aimed to determine the incidence of ventilator-associated pneumonia (VAP) in patients who were intubated with the PneuX System and to establish whether intermittent subglottic secretion drainage could be performed reliably and safely using the PneuX System.
- 31 January 2011
- Published by Elsevier in International Journal of Obstetric Anesthesia
- Vol. 20 (1) , 34-37
A comparison of two epidural catheter connectors
- 31 January 2011
- Published by Elsevier in International Journal of Obstetric Anesthesia
- Vol. 20 (1) , 34-37
A comparison of two epidural catheter connectors
- Open Access
- 9 December 2010
- Published by Springer Nature in BMC Anesthesiology
- Vol. 10 (1) , 21
The pressure exerted on the tracheal wall by two endotracheal tube cuffs: A prospective observational bench-top, clinical and radiological study
The Lotrach endotracheal tube has a unique low-volume, low-pressure (LVLP) cuff, which has been designed to prevent pressure injury to the tracheal wall. We aimed to estimate the pressure exerted on the tracheal wall by the LVLP cuff and a conventional cuff in a bench-top, clinical and radiological study.
- 9 December 2010
- Published by Springer Nature in BMC Anesthesiology
- Vol. 10 (1) , 21
Open AccessThe pressure exerted on the tracheal wall by two endotracheal tube cuffs: A prospective observational bench-top, clinical and radiological study
The Lotrach endotracheal tube has a unique low-volume, low-pressure (LVLP) cuff, which has been designed to prevent pressure injury to the tracheal wall. We aimed to estimate the pressure exerted on the tracheal wall by the LVLP cuff and a conventional cuff in a bench-top, clinical and radiological study.
- Open Access
- 1 January 2009
- Published by Springer Nature in Critical Care
- Vol. 13 (5) , 422
Swine flu: provision of ventilation in a worst-case scenario
- 1 January 2009
- Published by Springer Nature in Critical Care
- Vol. 13 (5) , 422
Open AccessSwine flu: provision of ventilation in a worst-case scenario
- 1 September 2007
- Published by Elsevier in Primary Care Diabetes
- Vol. 1 (3) , 155-158
An insight into undiagnosed impaired glucose regulation
- 1 September 2007
- Published by Elsevier in Primary Care Diabetes
- Vol. 1 (3) , 155-158
An insight into undiagnosed impaired glucose regulation
- Open Access
- 6 September 2005
- Published by Oxford University Press (OUP) in Interactive CardioVascular and Thoracic Surgery
- Vol. 4 (6) , 511-513
Sternal wound dehiscence after internal mammary artery harvesting. Logical management. Part 2
Wound breakdown is a serious complication of median sternotomy. This is generally met with a further attempt at surgical apposition using sutures of
- 6 September 2005
- Published by Oxford University Press (OUP) in Interactive CardioVascular and Thoracic Surgery
- Vol. 4 (6) , 511-513
Open AccessSternal wound dehiscence after internal mammary artery harvesting. Logical management. Part 2
Wound breakdown is a serious complication of median sternotomy. This is generally met with a further attempt at surgical apposition using sutures of