Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Umer Hassan has a total of 33 co-authors. Here are the top co-authors by number of shared publications:

  • Muhammad Ahsan Sami

    Department of Electrical and Computer Engineering, Rutgers, The State University of New Jersey, Piscataway, NJ, USA

    9 shared publications
  • Brandon K. Ashley

    Department of Biomedical Engineering, Rutgers, The State University of New Jersey, Piscataway, USA

    6 shared publications
  • Jianye Sui

    Department of Electrical and Computer Engineering at Rutgers, The State University of New Jersey, New Brunswick, NJ 08901, USA

    6 shared publications
  • Muhammad Nabeel Tahir

    Rutgers, The State University of New Jersey, Dept of Electrical and Computer Engineering, 94 Bret Rd, Piscataway, 08854 USA

    6 shared publications
  • Brandon K. Ashley

    Department of Biomedical Engineering, Rutgers, the State University of New Jersey, Piscataway, NJ, 08854, USA

    5 shared publications
  • Mehdi Javanmard

    Department of Electrical and Computer Engineering at Rutgers, The State University of New Jersey, New Brunswick, NJ 08901, USA

    5 shared publications

Latest Publications

  • Open Access

    Antioxidant suppression of hyperoxia-induced reactive oxygen species in cultured rat hippocampal neurons

    by Zia Ul Quasim Syed, Umer Hassan

    Antioxidant suppression monitoring of hyperoxia induced reactive oxygen species in cultured rat hippocampal neurons.

  • Open Access

    μFlow: A Computational Platform for Microfluidic Hall-Effect Magnetic Bead Detection with Parametric Design Optimization

    by Harshitha Govindaraju, Umer Hassan

    Microfluidic Hall-effect biosensors detect superparamagnetic bead labels as they flow past a thin-film Hall element in a microchannel. Designing one couples bead magnetization, stray-field distribution, Hall transport, and channel flow across 14 parameters that finite-element solvers explore only at minutes to hours per configuration. We present a coupled analytical–numerical framework for this signal chain: Clausius–Mossotti bead magnetization with a volume fraction correction, a point-dipole stray field, a volume-averaged Hall voltage, Poiseuille transport, and a Johnson–Nyquist and Hooge 1/f noise model, evaluated across 12 sensor presets compiled from the literature, spanning graphene, III–V semiconductors, Si CMOS, bismuth, and topological insulators; any other platform can be defined from user-supplied transport parameters. Benchmarked against a companion COMSOL Multiphysics 6.0 study, the framework reproduces the Hall voltage to within 4.8% at a favorable bead-to-sensor area ratio and deviates by 22% and 15% at off-optimum geometries, consistent with the point-dipole near-field limit at h/rb=1. Three design rules follow: a signal-to-noise ridge at sensor widths comparable to the bead diameter (w*≈db; area ratios 0.4–1.0 at constant voltage, 0.5–2.6 at constant current), matching reported single-bead geometries; a material choice that must be made under an explicit electrical drive constraint; and a sampling-limited flow-velocity window. Predicted signals agree at the order-of-magnitude level with published InAs and Si CMOS experiments. We release the model as a freely accessible, no-install browser implementation with a built-in 2D axisymmetric magnetostatic finite-element (FEM) solver that maps where the dipole approximation degrades.

  • Open Access

    Enabling multiple cellular enumeration applications of a bioparticle sensing platform using machine learning

    by Muhammad Nabeel Tahir, Brandon K. Ashley, Jianye Sui, Mehdi Javanmard, Umer Hassan

    Cellular surface receptors monitoring enabled by machine learning and impedance cytometry.


  • Open Access

    HIST-DIP: histogram thresholding and deep image priors assisted smartphone-based fluorescence microscopy imaging

    by Harshitha Govindaraju, Muhammad Nabeel Tahir, Umer Hassan

    Transformation of a benchtop fluorescence microscope to a smartphone 3D printed microscope with high accuracy of sensing enabled by HIST-DIP method.


  • Open Access

    Enhancing Biomarker Detection and Imaging Performance of Smartphone Fluorescence Microscopy Devices

    by Muhammad Ahsan Sami, Muhammad Nabeel Tahir, Umer Hassan

    Fluorescence microscopy enabled by smartphone-coupled 3D instruments has shown utility in different biomedical applications ranging from diagnostics to biomanufacturing. Recently, we have designed and developed these devices and have demonstrated their utility in micro-nano particle sensing and leukocyte imaging. Here, we present a novel application for enhancing the imaging performance of smartphone fluorescence microscopes (SFM) and reducing their operational complexity. Computational noise correction is employed using 3D Averaging and 3D Gaussian filters of different kernel sizes (3 × 3 × 3, 7 × 7 × 7, 11 × 11 × 11, 15 × 15 × 15, and 21 × 21 × 21) and various standard deviations σ (for Gaussian only). Fluorescent beads of different sizes (8.3, 2, 1, 0.8 µm) were imaged using a custom-designed SFM. The application of the computational filters significantly enhanced the signal quality of particle detection in the captured fluorescent images. Amongst the Averaging filters, a kernel size of 21 × 21 × 21 produced the best results for all bead sizes, and similarly, amongst Gaussian filters, σ equal to 5 and a kernel size equal to 21 × 21 × 21 produced the best results. This visual improvement was then quantified by calculating the signal-difference-to-noise ratio (SDNR) and contrast-to-noise ratio (CNR) of filtered and unfiltered original images using a custom-developed quality assessment algorithm (AQAFI). Lastly, noise correction using Averaging and Gaussian filters with the previously identified optimal parameters was applied to images of fluorescently tagged human peripheral blood leukocytes captured using an SFM under various conditions. The ubiquitous nature and simplistic application of these filters enable their utility with a range of existing fluorescence microscope designs, thus allowing us to enhance their imaging capabilities.

  • Open Access

    An assessment of machine learning methods to quantify blood lactate from neutrophils phagocytic activity

    by Muhammad Nabeel Tahir, Kurt Wagner, Umer Hassan

    Phagocytosis is a critical component of innate immunity that helps the body defend itself against infection, foreign particles, and cellular debris. Investigating and quantifying phagocytosis can help understand how the immune system identifies foreign particles and how phagocytosis relates to other biomarkers, e.g., cytokines, cell surface receptors, or blood lactate levels. In particular, increased blood lactate levels can be a potential biomarker to study diseases, e.g., septic shock. Establishing a relationship between phagocytosis and lactate levels can serve as an effective tool to monitor the immune response and may help stratify patients. In this study, we use phagocytosis activity data to classify the patients into two groups of blood lactate levels (High and Low) with machine learning models. The neutrophils extracted from the whole blood samples of 19 patients were used to collect data on phagocytosis, where the neutrophils were allowed to internalize IgG coated fluorescent bioparticles. The data collection process involved collecting whole blood samples, neutrophil isolation, adding fluorescent beads, incubating, and imaging the sample using a fluorescence microscope. The phagocytosis assay images were used to generate a numerical dataset by manually counting the number of particles engulfed by each cell. The study first presents an improved understanding by employing hierarchical clustering and heatmaps to generate the graphical representation of phagocytosis data. By comparing the results of heat maps and clustering techniques, it can be observed that the phagocytosis activity data can be used to differentiate blood lactate levels in two groups (control and high-risk). Later, three machine learning models (Decision Tree, k-nearest Neighbor, and Naïve Bayes) were trained on the original and pruned datasets after the outliers were removed. The AI models classified the data into high-risk and low-risk groups of blood lactate levels. A maximum classification accuracy of 78% and an area under the curve of 0.78 was achieved using the trained models.


  • FluoCount: An Efficient and Accurate Cells and Bioparticles Enumeration Mobile Application for Portable Fluorescence Microscopes

    by Muhammad Nabeel Tahir, Yongyu Xie, Muhammad Ahsan Sami, Rasika Punde, Umer Hassan

    Fluorescence microscopes are widely used to detect fluore-scent objects in a biological sample. However, traditional benchtop fluorescence microscopes are limited to high cost and nonportability. Recently, smartphone-based fluorescence microscopes (SFMs) have been developed, which capture images using a smartphone camera with the help of an external optical device and serve as an inexpensive and portable alternative. However, to analyze the images and get the accurate count of bioparticles, external software and computational resources are required; moreover, the lack of single and clustered count capabilities in SFMs without relying on an image library limits the use of SFMs. Here, we present an automated method as a mobile application with the ability to provide the bioparticle counts at the point of care by imaging human leukocytes and fluorescent microparticles. The application employs efficient image processing techniques that result in faster automated counting and reduced computational cost while providing comparable counts to industrial and academic standards. Compared with counting results calculated by ImageJ, a correlation coefficient of ${{R}^2}$ > 0.99 was observed along with the average relative error of ∼0.5% on different kinds of fluorescent images.


  • Open Access

    Enabling biomedical technologies for chronic myelogenous leukemia (CML) biomarkers detection

    by Meenakshi Pinnenti, Muhammad Ahsan Sami, Umer Hassan

    Chronic myelogenous/myeloid leukemia (CML) is a type of cancer of bone marrow that arises from hematopoietic stem cells and affects millions of people worldwide. Eighty-five percent of the CML cases are diagnosed during chronic phase, most of which are detected through routine tests. Leukocytes, micro-Ribonucleic Acids, and myeloid markers are the primary biomarkers for CML diagnosis and are mainly detected using real-time reverse transcription polymerase chain reaction, flow cytometry, and genetic testing. Though multiple therapies have been developed to treat CML, early detection still plays a pivotal role in the overall patient survival rate. The current technologies used for CML diagnosis are costly and are confined to laboratory settings which impede their application in the point-of-care settings for early-stage detection of CML. This study provides detailed analysis and insights into the significance of CML, patient symptoms, biomarkers used for testing, and best possible detection techniques responsible for the enhancement in survival rates. A critical and detailed review is provided around potential microfluidic devices that can be adapted to detect the biomarkers associated with CML while enabling point-of-care testing for early diagnosis of CML to improve patient survival rates.


  • AQAFI: a bioanalytical method for automated KPIs quantification of fluorescent images of human leukocytes and micro–nano particles

    by Muhammad A. Sami, Muhammad Nabeel Tahir, Umer Hassan

    Micro–nanoparticle and leukocyte imaging find significant applications in the areas of infectious disease diagnostics, cellular therapeutics, and biomanufacturing. Portable fluorescence microscopes have been developed for these measurements, however, quantitative assessment of the quality of images (micro–nanoparticles, and leukocytes) captured using these devices remains a challenge. Here, we present a novel method for automated quality assessment of fluorescent images (AQAFI) captured using smartphone fluorescence microscopes (SFM). AQAFI utilizes novel feature extraction methods to identify and measure multiple features of interest in leukocyte and micro–nanoparticle images. For validation of AQAFI, fluorescent particles of different diameters (8.3, 2, 1, 0.8 μm) were imaged using custom-designed SFM at a range of excitation voltages (3.8–4.5 V). Particle intensity, particle vicinity intensity, and image background noise were chosen as analytical parameters of interest and measured by the AQAFI algorithm. A control method was developed by manual calculation of these parameters using ImageJ which was subsequently used to validate the performance of the AQAFI method. For micro–nanoparticle images, correlation coefficients with R2 > 0.95 were obtained for each parameter of interest while comparing AQAFI vs. control (ImageJ). Subsequently, key performance indicators (KPIs) i.e., signal difference to noise ratio (SDNR) and contrast to noise ratio (CNR) were defined and calculated for these micro-nano particle images using both AQAFI and control methods. Finally, we tested the performance of the AQAFI method on the fluorescent images of human peripheral blood leukocytes captured using our custom SFM. Correlation coefficients of R2 = 0.99 were obtained for each parameter of interest (leukocyte intensity, vicinity intensity, background noise) calculated using AQAFI and control (ImageJ). A high correlation was also found between the CNR and SDNR values calculated using both methods. The developed AQAFI method thus presents an automated and precise way to quantify and assess the quality of fluorescent images (micro–nano particles and leukocytes) captured using portable SFMs. Similarly, this study finds broader applicability and can also be employed with benchtop microscopes for the quantitative assessment of their imaging performance.