Hao Gao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Hao Gao has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
Shujun Fu
Shandong University
3 shared publicationsYuting Lin
Emory University
3 shared publicationsBowen Lin
Emory University
2 shared publicationsTian Liu
Department of Radiation Oncology Winship Cancer Institute of Emory University Atlanta GA USA
2 shared publicationsBenjamin Clasie
Department of Radiation Oncology Massachusetts General Hospital and Harvard Medical School Boston MA USA
1 shared publicationEric Abel
Varian Medical Systems, Inc., Palo Alto, CA
1 shared publication
Latest Publications
- 14 June 2021
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 66 (12) , 125011
SDDRO-joint: simultaneous dose and dose rate optimization with the joint use of transmission beams and Bragg peaks for FLASH proton therapy
Cancer radiotherapy (RT) with the irradiation at ultra-high dose rates, namely FLASH-RT, can substantially reduce radiation-induced normal tissue toxicities while maintaining tumor response. Currently, clinical FLASH-RT on deep-seated tumors can only be performed with proton beams. One way to achieve ultra-high dose rates at depth is through the use of high-energy transmission beams (TB), where the Bragg peaks (BP) fall outside the body. However, planning with TB alone does not fully leverage the degrees of freedom for dose shaping as traditional intensity modulated proton therapy (IMPT) which uses the BP of multi-energy proton beams at the tumor target. This work will develop a simultaneous dose and dose rate optimization (SDDRO) method with the joint use of TB and BP, namely SDDRO-Joint. Specifically, BP are placed inside tumor targets to improve the target dose conformality and sparse the normal-tissue dose, while TB primarily cover the tumor boundary to achieve ultra-high dose rate coverage of organs-at-risk (OAR) close to tumor targets. The sparing of OAR and other normal tissues via SDDRO-Joint is jointly by TB and BP, i.e. the FLASH sparing by TB and the dose sparing by BP. The results suggest that the addition of BP substantially increased the target dose conformality for SDDRO. Noticeably SDDRO-Joint also provided slightly higher conformal index values than the conventional IMPT method with BP alone.
- 14 June 2021
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 66 (12) , 125011
SDDRO-joint: simultaneous dose and dose rate optimization with the joint use of transmission beams and Bragg peaks for FLASH proton therapy
Cancer radiotherapy (RT) with the irradiation at ultra-high dose rates, namely FLASH-RT, can substantially reduce radiation-induced normal tissue toxicities while maintaining tumor response. Currently, clinical FLASH-RT on deep-seated tumors can only be performed with proton beams. One way to achieve ultra-high dose rates at depth is through the use of high-energy transmission beams (TB), where the Bragg peaks (BP) fall outside the body. However, planning with TB alone does not fully leverage the degrees of freedom for dose shaping as traditional intensity modulated proton therapy (IMPT) which uses the BP of multi-energy proton beams at the tumor target. This work will develop a simultaneous dose and dose rate optimization (SDDRO) method with the joint use of TB and BP, namely SDDRO-Joint. Specifically, BP are placed inside tumor targets to improve the target dose conformality and sparse the normal-tissue dose, while TB primarily cover the tumor boundary to achieve ultra-high dose rate coverage of organs-at-risk (OAR) close to tumor targets. The sparing of OAR and other normal tissues via SDDRO-Joint is jointly by TB and BP, i.e. the FLASH sparing by TB and the dose sparing by BP. The results suggest that the addition of BP substantially increased the target dose conformality for SDDRO. Noticeably SDDRO-Joint also provided slightly higher conformal index values than the conventional IMPT method with BP alone.
- Open Access
- 17 October 2020
- Published by Wiley in Medical Physics
- Vol. 47 (12) , 6388-6395
Simultaneous dose and dose rate optimization (SDDRO) for FLASH proton therapy
Purpose: FLASH radiotherapy (RT) can potentially reduce normal tissue toxicity while preserving tumoricidal effectiveness to improve the therapeutic ratio. The key of FLASH for sparing normal tissues is to irradiate tissues with an ultra‐high dose rate (i.e., ≥40 Gy/s), for which proton RT can be used. However, currently available treatment plan optimization method only optimizes the dose distribution and does not directly optimize the dose rate. The contribution of this work to FLASH proton RT is the development of a novel treatment optimization method, that is, simultaneous dose and dose rate optimization (SDDRO), to optimize tissue‐receiving dose rate distribution as well as dose distribution.Methods: Distinguished from existing methods, SDDRO accounts for dose rate constraint and optimizes dose rate distribution. In terms of mathematical formulation, SDDRO is a constrained optimization problem with dose‐volume constraint on dose distribution, minimum dose rate constraint on dose‐averaged tissue‐receiving dose rates, minimum monitor unit constraint on spot weight, and maximum intensity constraint on beam intensity. In terms of optimization algorithm, SDDRO is solved by iterative convex relaxation and alternating direction method of multipliers. SDDRO algorithms are presented for both scenarios with either constant or variable beam intensity.Results: SDDRO was compared with intensity modulated proton therapy (IMPT) (dose optimization alone, and no dose rate optimization) using three lung cases. SDDRO substantially improved the dose rate distribution compared to IMPT, for example, increasing of the region‐of‐interest (ROI) volume (ROI = CTV_10mm: the ring sandwiched by 10 mm outer and inner expansion of CTV boundary) receiving at least 40 Gy/s from ~30–50% to at least 98%, and the lung volume receiving at least 40 Gy/s from ~30–40% to ~70–90%. Moreover, both dose and dose rate distributions from SDDRO were further considerably improved via the combined use of hypofractionation and multiple beams.Conclusions: We have developed a joint dose and dose rate optimization method for FLASH proton RT, namely SDDRO, which is first‐of‐its‐kind to the best of our knowledge. The results suggest that (a) SDDRO can substantially improve the FLASH‐dose rate coverage (e.g., in terms of dose rate volume histogram) compared to IMPT for the purpose of normal tissue sparing while preserving the dose distribution and (b) the combination of hypofractionation and multiple beams can further considerably improve the SDDRO plan quality in terms of both dose and dose rate distribution.
- 17 October 2020
- Published by Wiley in Medical Physics
- Vol. 47 (12) , 6388-6395
Open AccessSimultaneous dose and dose rate optimization (SDDRO) for FLASH proton therapy
Purpose: FLASH radiotherapy (RT) can potentially reduce normal tissue toxicity while preserving tumoricidal effectiveness to improve the therapeutic ratio. The key of FLASH for sparing normal tissues is to irradiate tissues with an ultra‐high dose rate (i.e., ≥40 Gy/s), for which proton RT can be used. However, currently available treatment plan optimization method only optimizes the dose distribution and does not directly optimize the dose rate. The contribution of this work to FLASH proton RT is the development of a novel treatment optimization method, that is, simultaneous dose and dose rate optimization (SDDRO), to optimize tissue‐receiving dose rate distribution as well as dose distribution.Methods: Distinguished from existing methods, SDDRO accounts for dose rate constraint and optimizes dose rate distribution. In terms of mathematical formulation, SDDRO is a constrained optimization problem with dose‐volume constraint on dose distribution, minimum dose rate constraint on dose‐averaged tissue‐receiving dose rates, minimum monitor unit constraint on spot weight, and maximum intensity constraint on beam intensity. In terms of optimization algorithm, SDDRO is solved by iterative convex relaxation and alternating direction method of multipliers. SDDRO algorithms are presented for both scenarios with either constant or variable beam intensity.Results: SDDRO was compared with intensity modulated proton therapy (IMPT) (dose optimization alone, and no dose rate optimization) using three lung cases. SDDRO substantially improved the dose rate distribution compared to IMPT, for example, increasing of the region‐of‐interest (ROI) volume (ROI = CTV_10mm: the ring sandwiched by 10 mm outer and inner expansion of CTV boundary) receiving at least 40 Gy/s from ~30–50% to at least 98%, and the lung volume receiving at least 40 Gy/s from ~30–40% to ~70–90%. Moreover, both dose and dose rate distributions from SDDRO were further considerably improved via the combined use of hypofractionation and multiple beams.Conclusions: We have developed a joint dose and dose rate optimization method for FLASH proton RT, namely SDDRO, which is first‐of‐its‐kind to the best of our knowledge. The results suggest that (a) SDDRO can substantially improve the FLASH‐dose rate coverage (e.g., in terms of dose rate volume histogram) compared to IMPT for the purpose of normal tissue sparing while preserving the dose distribution and (b) the combination of hypofractionation and multiple beams can further considerably improve the SDDRO plan quality in terms of both dose and dose rate distribution.
- 2 July 2020
- Published by Wiley in Medical Physics
- Vol. 47 (9) , 3892-3897
Technical Note: Plan‐delivery‐time constrained inverse optimization method with minimum‐MU‐per‐energy‐layer (MMPEL) for efficient pencil beam scanning proton therapy
Purpose: This work aims to reduce dose delivery time of pencil beam scanning (PBS) proton plans, which is the dominant factor of total plan delivery time. A proton PBS system, such as Varian ProBeam proton therapy system, can be equipped with the proton dose rate that is linearly proportional to the minimum monitor unit (MU) (i.e., number of protons) of PBS spots before saturation. Thus dose delivery time can be potentially reduced by increasing the MU threshold. However, commercially available treatment planning systems and current methods only allow for a single MU threshold globally for all PBS spots (i.e., all energy layers), and consequently the room to increase this minimum‐MU for reducing dose delivery time is very limited since higher minimum‐MU can greatly degrade treatment plan quality.Methods: Two major innovations of this work are the proposal of using variable MU thresholds locally adaptive to each energy layer, that is, minimum‐MU‐per‐energy‐layer (MMPEL), for reducing dose delivery time, and the joint optimization of plan delivery time and plan quality. Minimum‐MU‐per‐energy‐layer is formulated as a constrained optimization problem with objectives of dose‐volume‐histogram based planning constraints and plan delivery time, and minimum‐MU constraints per energy layer for deliverable PBS spots. Minimum‐MU‐per‐energy‐layer is solved by iterative convex relaxations via alternating direction method of multipliers.Results: Representative prostate, lung, brain, head‐and‐neck, breast, liver and pancreas cases were used to validate MMPEL. Minimum‐MU‐per‐energy‐layer reduced dose delivery time to 53%, 67%, 67%, 53%, 54%, 32%, and 14% respectively while maintaining a similar plan quality. Accepting a slightly degraded plan quality that still met all physician planning constraints, the treatment time could be further reduced to 26%, 35%, 41%, 34%, 32%, 16%, and 11% respectively, or in another word MMPEL accelerated the PBS plan delivery by 2–10 fold.Conclusions: A new proton PBS treatment planning method MMPEL with variable energy‐adaptive MU thresholds is developed to optimize dose delivery time jointly with plan quality. The preliminary results suggest that MMPEL could substantially reduce dose delivery time.
- 2 July 2020
- Published by Wiley in Medical Physics
- Vol. 47 (9) , 3892-3897
Technical Note: Plan‐delivery‐time constrained inverse optimization method with minimum‐MU‐per‐energy‐layer (MMPEL) for efficient pencil beam scanning proton therapy
Purpose: This work aims to reduce dose delivery time of pencil beam scanning (PBS) proton plans, which is the dominant factor of total plan delivery time. A proton PBS system, such as Varian ProBeam proton therapy system, can be equipped with the proton dose rate that is linearly proportional to the minimum monitor unit (MU) (i.e., number of protons) of PBS spots before saturation. Thus dose delivery time can be potentially reduced by increasing the MU threshold. However, commercially available treatment planning systems and current methods only allow for a single MU threshold globally for all PBS spots (i.e., all energy layers), and consequently the room to increase this minimum‐MU for reducing dose delivery time is very limited since higher minimum‐MU can greatly degrade treatment plan quality.Methods: Two major innovations of this work are the proposal of using variable MU thresholds locally adaptive to each energy layer, that is, minimum‐MU‐per‐energy‐layer (MMPEL), for reducing dose delivery time, and the joint optimization of plan delivery time and plan quality. Minimum‐MU‐per‐energy‐layer is formulated as a constrained optimization problem with objectives of dose‐volume‐histogram based planning constraints and plan delivery time, and minimum‐MU constraints per energy layer for deliverable PBS spots. Minimum‐MU‐per‐energy‐layer is solved by iterative convex relaxations via alternating direction method of multipliers.Results: Representative prostate, lung, brain, head‐and‐neck, breast, liver and pancreas cases were used to validate MMPEL. Minimum‐MU‐per‐energy‐layer reduced dose delivery time to 53%, 67%, 67%, 53%, 54%, 32%, and 14% respectively while maintaining a similar plan quality. Accepting a slightly degraded plan quality that still met all physician planning constraints, the treatment time could be further reduced to 26%, 35%, 41%, 34%, 32%, 16%, and 11% respectively, or in another word MMPEL accelerated the PBS plan delivery by 2–10 fold.Conclusions: A new proton PBS treatment planning method MMPEL with variable energy‐adaptive MU thresholds is developed to optimize dose delivery time jointly with plan quality. The preliminary results suggest that MMPEL could substantially reduce dose delivery time.
- 9 April 2020
- Published by Wiley in Medical Physics
- Vol. 47 (7) , 2916-2930
AirNet: Fused analytical and iterative reconstruction with deep neural network regularization for sparse‐data CT
Purpose: Sparse‐data computed tomography (CT) frequently occurs, such as breast tomosynthesis, C‐arm CT, on‐board four‐dimensional cone‐beam CT (4D CBCT), and industrial CT. However, sparse‐data image reconstruction remains challenging due to highly undersampled data. This work develops a data‐driven image reconstruction method for sparse‐data CT using deep neural networks (DNN).Methods: The new method so‐called AirNet is designed to incorporate the benefits from analytical reconstruction method (AR), iterative reconstruction method (IR), and DNN. It is built upon fused analytical and iterative reconstruction (AIR) that synergizes AR and IR via the optimization framework of modified proximal forward‐backward splitting (PFBS). By unrolling PFBS into IR updates of CT data fidelity and DNN regularization with residual learning, AirNet utilizes AR such as FBP during the data fidelity, introduces dense connectivity into DNN regularization, and learns PFBS coefficients and DNN parameters that minimize the loss function during the training stage; and then AirNet with trained parameters can be used for end‐to‐end image reconstruction.Results: A CT atlas of 100 prostate scans was used to validate the AirNet in comparison with state‐of‐art DNN‐based postprocessing and image reconstruction methods. The validation loss in AirNet had the fastest decreasing rate, owing to inherited fast convergence from AIR. AirNet was robust to noise in projection data and content differences between the training set and the images to be reconstructed. The impact of image quality on radiotherapy treatment planning was evaluated for both photon and proton therapy, and AirNet achieved the best treatment plan quality, especially for proton therapy. For example, with limited‐angle data, the maximal target dose for AirNet was 109.5% in comparison with the ground truth 109.1%, while it was significantly elevated to 115.1% and 128.1% for FBPConvNet and LEARN, respectively.Conclusions: A new image reconstruction AirNet is developed for sparse‐data CT image reconstruction. AirNet achieved the best image reconstruction quality both visually and quantitatively among all methods under comparison for all sparse‐data scenarios (sparse‐view and limited‐angle), and provided the best photon and proton treatment plan quality based on sparse‐data CT.
- 9 April 2020
- Published by Wiley in Medical Physics
- Vol. 47 (7) , 2916-2930
AirNet: Fused analytical and iterative reconstruction with deep neural network regularization for sparse‐data CT
Purpose: Sparse‐data computed tomography (CT) frequently occurs, such as breast tomosynthesis, C‐arm CT, on‐board four‐dimensional cone‐beam CT (4D CBCT), and industrial CT. However, sparse‐data image reconstruction remains challenging due to highly undersampled data. This work develops a data‐driven image reconstruction method for sparse‐data CT using deep neural networks (DNN).Methods: The new method so‐called AirNet is designed to incorporate the benefits from analytical reconstruction method (AR), iterative reconstruction method (IR), and DNN. It is built upon fused analytical and iterative reconstruction (AIR) that synergizes AR and IR via the optimization framework of modified proximal forward‐backward splitting (PFBS). By unrolling PFBS into IR updates of CT data fidelity and DNN regularization with residual learning, AirNet utilizes AR such as FBP during the data fidelity, introduces dense connectivity into DNN regularization, and learns PFBS coefficients and DNN parameters that minimize the loss function during the training stage; and then AirNet with trained parameters can be used for end‐to‐end image reconstruction.Results: A CT atlas of 100 prostate scans was used to validate the AirNet in comparison with state‐of‐art DNN‐based postprocessing and image reconstruction methods. The validation loss in AirNet had the fastest decreasing rate, owing to inherited fast convergence from AIR. AirNet was robust to noise in projection data and content differences between the training set and the images to be reconstructed. The impact of image quality on radiotherapy treatment planning was evaluated for both photon and proton therapy, and AirNet achieved the best treatment plan quality, especially for proton therapy. For example, with limited‐angle data, the maximal target dose for AirNet was 109.5% in comparison with the ground truth 109.1%, while it was significantly elevated to 115.1% and 128.1% for FBPConvNet and LEARN, respectively.Conclusions: A new image reconstruction AirNet is developed for sparse‐data CT image reconstruction. AirNet achieved the best image reconstruction quality both visually and quantitatively among all methods under comparison for all sparse‐data scenarios (sparse‐view and limited‐angle), and provided the best photon and proton treatment plan quality based on sparse‐data CT.