Carlos Fernando Pereira DA Silva Herrero
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Carlos Fernando Pereira DA Silva Herrero has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Breno Alves DE Sousa Vaz
Universidade Federal de Juiz de Fora
1 shared publication - Filipe Jun Shimaoka
Médico Assistente da Cirurgião de Mão, Hospital das Clínicas da Faculdade de Medicina de Ribeirão Preto da Universidade de São Paulo, HC-FMRP-USP, Campus Monte Alegre, 14049-900 Ribeirão Preto – SP, Brasil
1 shared publication Konrad Samwer
I. Physikalisches Institut, Georg-August-Universitat Gottingen, Göttingen, GERMANY
1 shared publication- Nilton Mazzer
Professor Titular e Chefe da Divisão de Cirurgia da Mão, Hospital das Clínicas da Faculdade de Medicina de Ribeirão Preto, Universidade de São Paulo, HC-FMRP-USP, Campus Monte Alegre 14049-910 Ribeirão Preto – SP, Brasil
1 shared publication - Ricardo Lucca Cabarite Saheb
Ribeirão Preto Medical School, University of São Paulo USP, Ribeirão Preto, Brazil
1 shared publication - Thabata Pasquini Soeira
Universidade de São Paulo, Brazil
1 shared publication
Latest Publications
- Open Access
- 1 January 2022
- Published by FapUNIFESP (SciELO) in Acta Ortopedica Brasileira
- Vol. 30 (1) , e246704
SURGICAL TREATMENT FOR RHIZARTHROSIS: A SYSTEMATIC REVIEW OF THE LAST 10 YEARS
Introduction Comparison of different surgical techniques to treat patients with rhizarthrosis or carpometacarpal osteoarthritis of the thumb. Materials and Methods A systematic review was conducted using three electronic databases. Randomized, controlled trials in patients who underwent surgery for the treatment of rhizarthrosis were included. The literature review followed the PRISMA protocol. Results A total of 15 articles involving a total population of 958 patients were selected. Seven different surgical techniques were compared. Conclusions We conclude that no procedure is superior to another in terms of pain, physical function, overall patient assessment, range of motion, or strength. Outcome measurements should be standardized to enable better comparison between surgical techniques. Level of evidence II, Systematic Review.
- 1 January 2022
- Published by FapUNIFESP (SciELO) in Acta Ortopedica Brasileira
- Vol. 30 (1) , e246704
Open AccessSURGICAL TREATMENT FOR RHIZARTHROSIS: A SYSTEMATIC REVIEW OF THE LAST 10 YEARS
Introduction Comparison of different surgical techniques to treat patients with rhizarthrosis or carpometacarpal osteoarthritis of the thumb. Materials and Methods A systematic review was conducted using three electronic databases. Randomized, controlled trials in patients who underwent surgery for the treatment of rhizarthrosis were included. The literature review followed the PRISMA protocol. Results A total of 15 articles involving a total population of 958 patients were selected. Seven different surgical techniques were compared. Conclusions We conclude that no procedure is superior to another in terms of pain, physical function, overall patient assessment, range of motion, or strength. Outcome measurements should be standardized to enable better comparison between surgical techniques. Level of evidence II, Systematic Review.
- 29 October 2018
- Published by IOP Publishing in Journal of Physics: Condensed Matter
- Vol. 30 (46) , 465803
Mechanical avalanches promoted by magnetoelastic coupling in magnetic metallic glasses
The effect of magnetoelastic coupling on the mechanical behavior of magnetic metallic glasses is studied by superposing a magnetic field to the mechanical load during deformation experiments. The mechanical response is studied from the point of view of the global behavior, characterized by the Young’s modulus, and from the perspective of the avalanches, estimated from the intermittency of the deformation signal. The influence of several intensities and orientations of magnetic field is analyzed in two amorphous alloys with different magnetostriction. For the highly magnetostrictive alloy, the decrease of the macroscopic Young’s modulus under certain magnetic fields is accompanied by the promotion of mechanical avalanches, a fact that suggests that in this case the magnetoelastic coupling involves some extent of non-linear addition of the magnetic and mechanical energies.
- 29 October 2018
- Published by IOP Publishing in Journal of Physics: Condensed Matter
- Vol. 30 (46) , 465803
Mechanical avalanches promoted by magnetoelastic coupling in magnetic metallic glasses
The effect of magnetoelastic coupling on the mechanical behavior of magnetic metallic glasses is studied by superposing a magnetic field to the mechanical load during deformation experiments. The mechanical response is studied from the point of view of the global behavior, characterized by the Young’s modulus, and from the perspective of the avalanches, estimated from the intermittency of the deformation signal. The influence of several intensities and orientations of magnetic field is analyzed in two amorphous alloys with different magnetostriction. For the highly magnetostrictive alloy, the decrease of the macroscopic Young’s modulus under certain magnetic fields is accompanied by the promotion of mechanical avalanches, a fact that suggests that in this case the magnetoelastic coupling involves some extent of non-linear addition of the magnetic and mechanical energies.