Sahil Choudhari
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Sahil Choudhari has a total of 33 co-authors. Here are the top co-authors by number of shared publications:
- Kavalipurapu Venkata Teja
Department of Conservative Dentistry and Endodontics, Malla Reddy Institute of Dental Sciences, Malla Reddy Vishwavidyapeeth, Hyderabad, India
3 shared publications - Gianrico Spagnuolo
Department of Neurosciences, Reproductive and Odontostomatological Sciences University of Naples “Federico II” Napoli Italy
2 shared publications - Jerry Jose
Private Practice, Kochi, Kerala, India
2 shared publications - Karan Shahi
Intern, Christian Dental College, Ludhiana, Punjab, India
2 shared publications - Keerthika Rajamanickam
Department of Conservative Dentistry and Endodontics, Saveetha Dental College, Saveetha Institute of Medical and Technical Sciences, Saveetha University, Chennai 600077, India
2 shared publications - Mariangela Cernera
Department of Neurosciences, Reproductive and Odontostomatological Sciences, University of Naples Federico II, 80131 Naples, Italy
2 shared publications
Latest Publications
- Open Access
- 1 January 2026
- Published by FapUNIFESP (SciELO) in Pesquisa Brasileira em Odontopediatria e Clínica Integrada
- Vol. 26
Comparative Evaluation of Postoperative Pain Following Nonsurgical Endodontic Therapy with Calcium Silicate-Based Sealer and Traditional Sealers: A Systematic Review and Meta-Analysis
Objective: To systematically review and compare postoperative pain levels following NSET using calcium silicate-based sealers versus traditional sealers. Material and Methods: This systematic review adhered to PRISMA 2020 guidelines and was registered with PROSPERO (CRD42024607698). A comprehensive search of the PubMed, Scopus, and Web of Science databases was conducted to identify clinical trials comparing postoperative pain following obturation with calcium silicate-based versus traditional sealers. Studies including patients with symptomatic irreversible pulpitis or retreatment cases were selected. Pain outcomes were assessed using visual analog scales (VAS) or numeric rating scales (NRS) at 24 hours to 7 days postoperatively. Risk of bias was evaluated using RoB-2 for randomized trials and ROBINS-I for non-randomized trials. Meta-analysis was conducted where appropriate. Results: Five studies met the inclusion criteria. Meta-analysis indicated that calcium silicate-based sealers significantly reduced postoperative pain at 24 hours (SMD: -0.34; 95% CI: -0.63 to -0.04; p=0.02) but not at 48 hours (SMD: -0.26; 95% CI: -0.62 to 0.11; p=0.17). Overall, calcium silicate-based sealers demonstrated lower postoperative pain, especially within the first 24-72 hours. However, variability among study designs, patient conditions, and obturation techniques influenced outcomes. Conclusion: Calcium silicate-based sealers may offer short-term advantages in reducing postoperative pain after NSET. Nevertheless, findings were inconsistent across studies, and further high-quality randomized controlled trials are needed to confirm these results and establish long-term clinical relevance.
- 1 January 2026
- Published by FapUNIFESP (SciELO) in Pesquisa Brasileira em Odontopediatria e Clínica Integrada
- Vol. 26
Open AccessComparative Evaluation of Postoperative Pain Following Nonsurgical Endodontic Therapy with Calcium Silicate-Based Sealer and Traditional Sealers: A Systematic Review and Meta-Analysis
Objective: To systematically review and compare postoperative pain levels following NSET using calcium silicate-based sealers versus traditional sealers. Material and Methods: This systematic review adhered to PRISMA 2020 guidelines and was registered with PROSPERO (CRD42024607698). A comprehensive search of the PubMed, Scopus, and Web of Science databases was conducted to identify clinical trials comparing postoperative pain following obturation with calcium silicate-based versus traditional sealers. Studies including patients with symptomatic irreversible pulpitis or retreatment cases were selected. Pain outcomes were assessed using visual analog scales (VAS) or numeric rating scales (NRS) at 24 hours to 7 days postoperatively. Risk of bias was evaluated using RoB-2 for randomized trials and ROBINS-I for non-randomized trials. Meta-analysis was conducted where appropriate. Results: Five studies met the inclusion criteria. Meta-analysis indicated that calcium silicate-based sealers significantly reduced postoperative pain at 24 hours (SMD: -0.34; 95% CI: -0.63 to -0.04; p=0.02) but not at 48 hours (SMD: -0.26; 95% CI: -0.62 to 0.11; p=0.17). Overall, calcium silicate-based sealers demonstrated lower postoperative pain, especially within the first 24-72 hours. However, variability among study designs, patient conditions, and obturation techniques influenced outcomes. Conclusion: Calcium silicate-based sealers may offer short-term advantages in reducing postoperative pain after NSET. Nevertheless, findings were inconsistent across studies, and further high-quality randomized controlled trials are needed to confirm these results and establish long-term clinical relevance.
- 25 July 2025
- Published by Springer Nature in British Dental Journal
- Vol. 239 (2) , 84
Expanding the role of dental therapists
- 25 July 2025
- Published by Springer Nature in British Dental Journal
- Vol. 239 (2) , 84
Expanding the role of dental therapists
- Open Access
- 23 May 2025
- Published by Springer Nature in British Dental Journal
- Vol. 238 (10) , 750
Global oral health: moving from policy to action
- 23 May 2025
- Published by Springer Nature in British Dental Journal
- Vol. 238 (10) , 750
Open AccessGlobal oral health: moving from policy to action
- Open Access
- 1 January 2024
- Published by Wiley in International Journal of Dentistry
- Vol. 2024 (1) , 8823070
Assessment of Anatomical Dentin Thickness in Mandibular First Molar: An In Vivo Cone‐Beam Computed Tomographic Study
Aim. To determine the minimum dentin thickness in the mesial and distal walls of the mesiobuccal (MB) and mesiolingual (ML) canals of the mandibular first molars using cone‐beam computed tomography (CBCT). Materials and Methods. CBCT examinations of 624 mandibular first molars from an Indian subpopulation were analyzed. The mesial and distal minimum dentin thickness was evaluated in 1 mm intervals apical to the furcation area. Independent t‐test was used to analyze the data (α = 0.05). Using Cohen’s kappa coefficient, the interexaminer and intraexaminer reliability was evaluated. Results. The mesial dentin thickness was significantly higher than the distal dentin thickness for MB and ML canals (P = 0.01). The average dentin thickness in the distal and mesial plane of the MB canal was 1.15 ± 0.15 mm and 1.52 ± 0.19 mm at the 1 mm level and 0.83 ± 0.13 and 1.08 ± 0.18 at the 5 mm level, respectively. For the ML canal, the average dentin thickness in the distal plane and the mesial plane was 1.24 ± 0.18 mm and 1.44 ± 0.21 at the 1 mm level and 0.91 ± 0.16 and 1.01 ± 0.17 at the 5 mm level, respectively. Statistical analysis between the MB and ML canals showed significant differences in the dentin thickness at 4 and 5 mm levels in both the distal and the mesial planes (P = 0.01). In more than 85% of the cases, the minimum dentin thickness was seen at the 5 mm level in both the distal and mesial planes in MB and ML canals. Conclusion. The distal planes of the mesiolingual and mesiobuccal canals were thinner in most cases, making the distal surface more prone to iatrogenic perforations. Considerably, at 4 and 5 mm from the furcation, the distal wall was significantly thinner than the mesial walls. Understanding the anatomy of the danger zone in the mesial roots of the mandibular first molars may serve to minimize the risk of endodontic mishaps such as strip perforations.
- 1 January 2024
- Published by Wiley in International Journal of Dentistry
- Vol. 2024 (1) , 8823070
Open AccessAssessment of Anatomical Dentin Thickness in Mandibular First Molar: An In Vivo Cone‐Beam Computed Tomographic Study
Aim. To determine the minimum dentin thickness in the mesial and distal walls of the mesiobuccal (MB) and mesiolingual (ML) canals of the mandibular first molars using cone‐beam computed tomography (CBCT). Materials and Methods. CBCT examinations of 624 mandibular first molars from an Indian subpopulation were analyzed. The mesial and distal minimum dentin thickness was evaluated in 1 mm intervals apical to the furcation area. Independent t‐test was used to analyze the data (α = 0.05). Using Cohen’s kappa coefficient, the interexaminer and intraexaminer reliability was evaluated. Results. The mesial dentin thickness was significantly higher than the distal dentin thickness for MB and ML canals (P = 0.01). The average dentin thickness in the distal and mesial plane of the MB canal was 1.15 ± 0.15 mm and 1.52 ± 0.19 mm at the 1 mm level and 0.83 ± 0.13 and 1.08 ± 0.18 at the 5 mm level, respectively. For the ML canal, the average dentin thickness in the distal plane and the mesial plane was 1.24 ± 0.18 mm and 1.44 ± 0.21 at the 1 mm level and 0.91 ± 0.16 and 1.01 ± 0.17 at the 5 mm level, respectively. Statistical analysis between the MB and ML canals showed significant differences in the dentin thickness at 4 and 5 mm levels in both the distal and the mesial planes (P = 0.01). In more than 85% of the cases, the minimum dentin thickness was seen at the 5 mm level in both the distal and mesial planes in MB and ML canals. Conclusion. The distal planes of the mesiolingual and mesiobuccal canals were thinner in most cases, making the distal surface more prone to iatrogenic perforations. Considerably, at 4 and 5 mm from the furcation, the distal wall was significantly thinner than the mesial walls. Understanding the anatomy of the danger zone in the mesial roots of the mandibular first molars may serve to minimize the risk of endodontic mishaps such as strip perforations.
- Open Access
- 17 August 2023
- Published by Springer Nature in Cureus
- Vol. 15 (8) , e43669
In Vitro Evaluation of the Effects of Different Beverages on the Surface Microhardness of a Single-Shade Universal Composite
Aim: The aim of this in vitro study was to analyze the influence of various beverages on the surface microhardness of a single-shade composite resin. Materials and methods: Seventy-five Omnichroma composite discs were fabricated and divided into five subgroups according to the beverages. The groups were Group A: tea; Group B: coffee; Group C: beer; Group D: whisky; and Group E: artificial saliva. The samples were immersed in their respective beverages for 15 minutes per day for 15 days. The Vickers microhardness values were taken before and after the immersion of the composite disc samples in their respective beverages. A one-way analysis of variance (ANOVA) test was conducted using IBM SPSS Statistics software version 23 (IBM Corp., Armonk, New York, USA), with a statistical significance level of 5%. Results: It was observed that there was a reduction in the surface microhardness of the composite resin after immersion in most of the solutions. An increase in the mean percentage change of surface microhardness was observed in the beer group (29%; mean difference = 16.52±12.05), followed by the coffee group (27.2%; mean difference = 15.51±9.28). The least mean percentage change in microhardness was noted in group E, artificial saliva (8.5%; mean difference = 4.81±3.04). Conclusion: The surface microhardness of composite resin can be influenced by the type of beverages used for immersion and the duration of immersion. However, it is important to note that the interaction between composite resin and various beverages is influenced by a complex interplay of multiple variables.
- 17 August 2023
- Published by Springer Nature in Cureus
- Vol. 15 (8) , e43669
Open AccessIn Vitro Evaluation of the Effects of Different Beverages on the Surface Microhardness of a Single-Shade Universal Composite
Aim: The aim of this in vitro study was to analyze the influence of various beverages on the surface microhardness of a single-shade composite resin. Materials and methods: Seventy-five Omnichroma composite discs were fabricated and divided into five subgroups according to the beverages. The groups were Group A: tea; Group B: coffee; Group C: beer; Group D: whisky; and Group E: artificial saliva. The samples were immersed in their respective beverages for 15 minutes per day for 15 days. The Vickers microhardness values were taken before and after the immersion of the composite disc samples in their respective beverages. A one-way analysis of variance (ANOVA) test was conducted using IBM SPSS Statistics software version 23 (IBM Corp., Armonk, New York, USA), with a statistical significance level of 5%. Results: It was observed that there was a reduction in the surface microhardness of the composite resin after immersion in most of the solutions. An increase in the mean percentage change of surface microhardness was observed in the beer group (29%; mean difference = 16.52±12.05), followed by the coffee group (27.2%; mean difference = 15.51±9.28). The least mean percentage change in microhardness was noted in group E, artificial saliva (8.5%; mean difference = 4.81±3.04). Conclusion: The surface microhardness of composite resin can be influenced by the type of beverages used for immersion and the duration of immersion. However, it is important to note that the interaction between composite resin and various beverages is influenced by a complex interplay of multiple variables.
- Open Access
- 6 January 2023
- Published by MDPI AG in Applied Sciences
- Vol. 13 (2) , 796
Evaluation of Root Canal Cleanliness on Using a Novel Irrigation Device with an Ultrasonic Activation Technique: An Ex Vivo Study
Root canal preparation generates inorganic and organic tissue debris. Various irrigation techniques are used to remove the smear layer from the root canal system. The present study aimed to evaluate canal cleanliness using a novel irrigation device with ultrasonic and manual irrigation in extracted teeth. Twenty-one freshly extracted single-rooted teeth with specified inclusion and exclusion criteria were collected for the present study. The specimens were prepared to a size using a rotary file to size 30 and 6% taper preparation. The specimens were then divided into three groups: group I, Manual irrigation group (n = 7), group II, Automated irrigation (n = 7), group III, Passive ultrasonic irrigation (n = 7). Following the experimental irrigation, the teeth were subjected to the scanning electron microscopy (SEM). Statistically significant reduction (p < 0.05) in both smear layer and debris scores were seen in group III as compared to the other groups. Based on Hülsmann’s scoring method, it was found that the automated root canal irrigation device showed better canal cleanliness when compared with the manual irrigation technique but was less effective than passive ultrasonic irrigation.
- 6 January 2023
- Published by MDPI AG in Applied Sciences
- Vol. 13 (2) , 796
Open AccessEvaluation of Root Canal Cleanliness on Using a Novel Irrigation Device with an Ultrasonic Activation Technique: An Ex Vivo Study
Root canal preparation generates inorganic and organic tissue debris. Various irrigation techniques are used to remove the smear layer from the root canal system. The present study aimed to evaluate canal cleanliness using a novel irrigation device with ultrasonic and manual irrigation in extracted teeth. Twenty-one freshly extracted single-rooted teeth with specified inclusion and exclusion criteria were collected for the present study. The specimens were prepared to a size using a rotary file to size 30 and 6% taper preparation. The specimens were then divided into three groups: group I, Manual irrigation group (n = 7), group II, Automated irrigation (n = 7), group III, Passive ultrasonic irrigation (n = 7). Following the experimental irrigation, the teeth were subjected to the scanning electron microscopy (SEM). Statistically significant reduction (p < 0.05) in both smear layer and debris scores were seen in group III as compared to the other groups. Based on Hülsmann’s scoring method, it was found that the automated root canal irrigation device showed better canal cleanliness when compared with the manual irrigation technique but was less effective than passive ultrasonic irrigation.
- Open Access
Comparative Study Assessing the Canal Cleanliness Using Automated Device and Conventional Syringe Needle for Root Canal Irrigation—An Ex-Vivo Study
The success of endodontic treatment relies on both apical and coronal sealing. To achieve a good three-dimensional seal, the removal of the smear layer becomes mandatory. This study aims to assess the difference in debris accumulation and smear layer formation while using automated root canal irrigation and conventional syringe needle irrigation. Single-rooted human mandibular premolar teeth (n = 30) which were indicated for orthodontic extractions were selected. An endodontic access cavity was prepared, and a glide path was created. Based on the irrigation protocol decided upon for the study, the teeth were randomly allocated into three study groups, namely Group 1, where the manual syringe needle irrigation method was adopted; Group 2, in which automated root canal irrigation was undertaken; and Group 3, in which teeth remained un-instrumented as it was considered the Control group. The teeth were decoronated at the cement-enamel junction (CEJ) and were subjected for scanning electron microscopy (SEM) examination. Debris and smear layers were viewed in 1000× magnification and scored. A statistically significant (p < 0.05) lower mean debris and smear layer score (p < 0.05) was observed in both study groups when compared with the control group. However, no significant difference (p > 0.05) in the debris and smear layer was observed between the manual syringe needle irrigation and automated irrigation, although automated irrigation devices can be a potential alternative. The present study concluded that the efficacy of smear layer removal remained the same with both automated irrigation and manual syringe irrigation.
Open AccessComparative Study Assessing the Canal Cleanliness Using Automated Device and Conventional Syringe Needle for Root Canal Irrigation—An Ex-Vivo Study
The success of endodontic treatment relies on both apical and coronal sealing. To achieve a good three-dimensional seal, the removal of the smear layer becomes mandatory. This study aims to assess the difference in debris accumulation and smear layer formation while using automated root canal irrigation and conventional syringe needle irrigation. Single-rooted human mandibular premolar teeth (n = 30) which were indicated for orthodontic extractions were selected. An endodontic access cavity was prepared, and a glide path was created. Based on the irrigation protocol decided upon for the study, the teeth were randomly allocated into three study groups, namely Group 1, where the manual syringe needle irrigation method was adopted; Group 2, in which automated root canal irrigation was undertaken; and Group 3, in which teeth remained un-instrumented as it was considered the Control group. The teeth were decoronated at the cement-enamel junction (CEJ) and were subjected for scanning electron microscopy (SEM) examination. Debris and smear layers were viewed in 1000× magnification and scored. A statistically significant (p < 0.05) lower mean debris and smear layer score (p < 0.05) was observed in both study groups when compared with the control group. However, no significant difference (p > 0.05) in the debris and smear layer was observed between the manual syringe needle irrigation and automated irrigation, although automated irrigation devices can be a potential alternative. The present study concluded that the efficacy of smear layer removal remained the same with both automated irrigation and manual syringe irrigation.
- 1 January 2020
- Published by A and V Publications in Research Journal of Pharmacy and Technology
- Vol. 13 (2) , 575
Palatal Rugae Patterns in Forensic Identification
- 1 January 2020
- Published by A and V Publications in Research Journal of Pharmacy and Technology
- Vol. 13 (2) , 575
Palatal Rugae Patterns in Forensic Identification