MFMichael Fernandez

Michael Fernandez

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Michael Fernandez has a total of 8 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    A Parameterized Ultrasound-Based Finite Element Analysis of the Mechanical Environment of Pregnancy

    by Andrea R. Westervelt, Michael Fernandez, Michael House, Joy Vink, Chia-Ling Nhan-Chang, Ronald Wapner, Kristin M. Myers

    Preterm birth is the leading cause of childhood mortality and can lead to health risks in survivors. The mechanical functions of the uterus, fetal membranes, and cervix have dynamic roles to protect the fetus during gestation. To understand their mechanical function and relation to preterm birth, we built a three-dimensional parameterized finite element model of pregnancy. This model is generated by an automated procedure that is informed by maternal ultrasound measurements. A baseline model at 25 weeks of gestation was characterized, and to visualize the impact of cervical structural parameters on tissue stretch, we evaluated the model sensitivity to (1) anterior uterocervical angle, (2) cervical length, (3) posterior cervical offset, and (4) cervical stiffness. We found that cervical tissue stretching is minimal when the cervical canal is aligned with the longitudinal uterine axis, and a softer cervix is more sensitive to changes in the geometric variables tested.


  • Direct Measurement of the Permeability of Human Cervical Tissue

    by Michael Fernandez, Joy Vink, Kyoko Yoshida, Ronald Wapner, Kristin M. Myers

    The mechanical integrity of the uterine cervix is critical for a pregnancy to successfully reach full term. It must be strong to retain the fetus throughout gestation and then undergo a remodeling and softening process before labor for delivery of the fetus. It is believed that cervical insufficiency (CI), a condition in pregnancy resulting in preterm birth (PTB), is related to a cervix with compromised mechanical strength which cannot resist deformation caused by external forces generated by the growing fetus. Such PTBs are responsible for infant developmental problems and in severe cases infant mortality. To understand the etiologies of CI, our overall research goal is to investigate the mechanical behavior of the cervix. Permeability is a mechanical property of hydrated collagenous tissues that dictates the time-dependent response of the tissue to mechanical loading. The goal of this study was to design a novel soft tissue permeability testing device and to present direct hydraulic permeability measurements of excised nonpregnant (NP) and pregnant (PG) human cervical tissue from women with different obstetric histories. Results of hydraulic permeability testing indicate repeatability for specimens from single patients, with an order of magnitude separating the NP and PG group means (2.1 ± 1.4×10-14 and 3.2 ± 4.8×10-13m4/N·s, respectively), and large variability within the NP and PG sample groups. Differences were found between samples with similar obstetric histories, supporting the view that medical history may not be a good predictor of permeability (and therefore mechanical behavior) and highlighting the need for patient-specific measurements of cervical mechanical properties. The permeability measurements from this study will be used in future work to model the constitutive material behavior of cervical tissue and to develop in vivo diagnostic tools to stage the progression of labor.