Michael Reynolds
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Michael Reynolds has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Bg Gino Fallone
University of Alberta
4 shared publications S. Rathee
Department of Medical Physics, Cross Cancer Institute, 11560 University Avenue, Edmonton, Alberta T6G 1Z2, Canada and Department of Oncology, Medical Physics Division,University of Alberta, 11560 University Avenue, Edmonton, Alberta T6G 1Z2, Canada
2 shared publicationsSatyapal Rathee
Department of Oncology, Medical Physics Division, University of Alberta, 11560 University Avenue, Edmonton, Alberta, T6G 1Z2, Canada
2 shared publications- Joel St-Aubin
Department of Radiation Oncology, University of Iowa Health Care, Iowa City, IA, United States
1 shared publication
Latest Publications
- 4 May 2019
- Published by Wiley in Medical Physics
- Vol. 46 (7) , 3306-3310
Technical Note: Sensitive volume effects on ion chamber responses in longitudinal magnetic fields
Purpose: It has been shown that ion chamber dose response Monte Carlo simulations, in transverse magnetic fields, are susceptible to small changes in the scored sensitive volume. Changes in sensitive volumes have been investigated as a surrogate for modeling the true collection volume governed by the electric field. This work has not been fully extended to longitudinal fields. This study investigates the effect of the sensitive volume of ion chambers on magnetic field dose response within longitudinal magnetic fields.Methods: The egs_chamber application within EGSnrc was used to model the Exradin A19, A28, and A1SL ion chambers within a uniform longitudinal magnetic field. The sensitive volume of the ion chambers was varied by removing portions of the air volume (from 0.2 to 3 mm) closest to the chamber stem from the dose scoring region; the dose to the scoring volume as a function of magnetic fields strength was normalized to 0 T in all cases.Results: With the chamber long axis oriented parallel to the radiation and magnetic fields, for every magnetic field strength, all investigated chambers' dose response remained inside statistical variations for all investigated chamber sensitive volumes. When the chamber long axis is oriented perpendicular to the radiation and magnetic fields, the A28 and A1SL show negligible sensitive volume effects, while the A19 under responded by 0.5% for the largest removed volume of 3 mm.Conclusions: When the ion chambers' long axis is parallel to the radiation and magnetic fields, the magnetic field dose response is unaffected by small changes in sensitive volume. When oriented perpendicularly, only the A19 exhibits sensitive volume based magnetic field dose response changes, and only with ≥ 1 mm of assumed insensitive volume. We can therefore safely assume complete charge collection in Monte Carlo calculated correction factors involving similar chambers in similar conditions.
- 4 May 2019
- Published by Wiley in Medical Physics
- Vol. 46 (7) , 3306-3310
Technical Note: Sensitive volume effects on ion chamber responses in longitudinal magnetic fields
Purpose: It has been shown that ion chamber dose response Monte Carlo simulations, in transverse magnetic fields, are susceptible to small changes in the scored sensitive volume. Changes in sensitive volumes have been investigated as a surrogate for modeling the true collection volume governed by the electric field. This work has not been fully extended to longitudinal fields. This study investigates the effect of the sensitive volume of ion chambers on magnetic field dose response within longitudinal magnetic fields.Methods: The egs_chamber application within EGSnrc was used to model the Exradin A19, A28, and A1SL ion chambers within a uniform longitudinal magnetic field. The sensitive volume of the ion chambers was varied by removing portions of the air volume (from 0.2 to 3 mm) closest to the chamber stem from the dose scoring region; the dose to the scoring volume as a function of magnetic fields strength was normalized to 0 T in all cases.Results: With the chamber long axis oriented parallel to the radiation and magnetic fields, for every magnetic field strength, all investigated chambers' dose response remained inside statistical variations for all investigated chamber sensitive volumes. When the chamber long axis is oriented perpendicular to the radiation and magnetic fields, the A28 and A1SL show negligible sensitive volume effects, while the A19 under responded by 0.5% for the largest removed volume of 3 mm.Conclusions: When the ion chambers' long axis is parallel to the radiation and magnetic fields, the magnetic field dose response is unaffected by small changes in sensitive volume. When oriented perpendicularly, only the A19 exhibits sensitive volume based magnetic field dose response changes, and only with ≥ 1 mm of assumed insensitive volume. We can therefore safely assume complete charge collection in Monte Carlo calculated correction factors involving similar chambers in similar conditions.
- 28 September 2018
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 63 (19) , 195006
Monte Carlo determination of k Q and k Qmsr values for the exradin A26 ionisation chamber for the Varian TrueBeam
We have calculated conversion factors, k Q for the A26 micro ionisation chamber along with machine specific reference beam quality factors, k Qmsr , for a number of field sizes and beam qualities for the Varian TrueBeam accelerator. The A12 ionisation chamber was simulated alongside the A26, so as to validate against known literature values. Both ionisation chambers were modelled from manufacturer data sheets and schematics. The egs_chamber Monte Carlo user code was used to simulate each absorbed dose relevant to the beam quality conversion factors k Q and k Qmsr . Tabulated spectra for beam energies of 4 through 25 MV were used in the k Q calculations for both investigated chambers. Varian TrueBeam phase space files for 6 MV flattened as well as 6 and 10 MV unflattened beams were used in the simulations of the A26 chamber in field sizes from 2 × 2 cm square to 20 × 20 cm square in order to determine k Qmsr values. The PDD(10)x values of the tabulated spectra were found to be within variation between studies, with an average deviance of 0.4% from one prior study. The simulated A12 k Q values matched the accepted literature values with an average variation of k Q values match the manufacturer provided values to within 0.5%. For all investigated field sizes the k Qmsr values are within 0.006 of unity. There is no published data for this chamber for a direct comparison, but there is similarity between these results and results from other chambers regularly used in similar circumstances. Furthermore, the agreement of the simulated k Q values to knowns, and the agreement of the PDD(10)x factors would suggest the correctness and accuracy of the study.
- 28 September 2018
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 63 (19) , 195006
Monte Carlo determination of k Q and k Qmsr values for the exradin A26 ionisation chamber for the Varian TrueBeam
We have calculated conversion factors, k Q for the A26 micro ionisation chamber along with machine specific reference beam quality factors, k Qmsr , for a number of field sizes and beam qualities for the Varian TrueBeam accelerator. The A12 ionisation chamber was simulated alongside the A26, so as to validate against known literature values. Both ionisation chambers were modelled from manufacturer data sheets and schematics. The egs_chamber Monte Carlo user code was used to simulate each absorbed dose relevant to the beam quality conversion factors k Q and k Qmsr . Tabulated spectra for beam energies of 4 through 25 MV were used in the k Q calculations for both investigated chambers. Varian TrueBeam phase space files for 6 MV flattened as well as 6 and 10 MV unflattened beams were used in the simulations of the A26 chamber in field sizes from 2 × 2 cm square to 20 × 20 cm square in order to determine k Qmsr values. The PDD(10)x values of the tabulated spectra were found to be within variation between studies, with an average deviance of 0.4% from one prior study. The simulated A12 k Q values matched the accepted literature values with an average variation of k Q values match the manufacturer provided values to within 0.5%. For all investigated field sizes the k Qmsr values are within 0.006 of unity. There is no published data for this chamber for a direct comparison, but there is similarity between these results and results from other chambers regularly used in similar circumstances. Furthermore, the agreement of the simulated k Q values to knowns, and the agreement of the PDD(10)x factors would suggest the correctness and accuracy of the study.
- 10 July 2017
- Published by Wiley in Medical Physics
- Vol. 44 (8) , 4322-4328
Technical Note: Ion chamber angular dependence in a magnetic field
Purpose: There have been several studies investigating dose deposition effects within radiation detectors in the presence of a magnetic field. However, to date there has only been a passing investigation which explicitly investigates detector dose–response as a function of detector orientation. Herein we will investigate the dose–response as a function angular orientation of a PR06C ionization chamber. We will also benchmark the Monte Carlo code PENELOPE with the newly developed magnetic field Fano test.Methods: The PENELOPE Monte Carlo package was used to simulate a PR06C ionization chamber in 0.35 T through 1.5 T magnetic fields oriented either parallel or orthogonal to an incident 6 MV radiation beam. The ionization chamber was rotated through a number of polar and azimuthal angles. The dose deposited within the chamber at each angular position and magnetic field strength was scored then normalized to that deposited in the same orientation with no magnetic field. The simulation was also benchmarked via a Fano test in magnetic field.Results: The Fano test yielded a 0.4% difference between simulation and expected result, which is similar to previous findings and sufficient for the purposes of this study. The angular dose–response map in all cases where the magnetic field is oriented orthogonal to the radiation beam is quite varied and can range from 0.89 to 1.08. Angular deviations as small as 3° can lead to dose–response changes in excess of 1%. When the magnetic field is parallel to the photon beam, the angular dose–response map is homogeneous and less than 1% below 1.0 T.Conclusions: Within a magnetic field‐oriented orthogonal to the radiation beam, the ionization chamber dose–response fluctuates greatly as a function of polar and azimuthal angle, where a parallel field yields a more homogeneous dose–response.
- 10 July 2017
- Published by Wiley in Medical Physics
- Vol. 44 (8) , 4322-4328
Technical Note: Ion chamber angular dependence in a magnetic field
Purpose: There have been several studies investigating dose deposition effects within radiation detectors in the presence of a magnetic field. However, to date there has only been a passing investigation which explicitly investigates detector dose–response as a function of detector orientation. Herein we will investigate the dose–response as a function angular orientation of a PR06C ionization chamber. We will also benchmark the Monte Carlo code PENELOPE with the newly developed magnetic field Fano test.Methods: The PENELOPE Monte Carlo package was used to simulate a PR06C ionization chamber in 0.35 T through 1.5 T magnetic fields oriented either parallel or orthogonal to an incident 6 MV radiation beam. The ionization chamber was rotated through a number of polar and azimuthal angles. The dose deposited within the chamber at each angular position and magnetic field strength was scored then normalized to that deposited in the same orientation with no magnetic field. The simulation was also benchmarked via a Fano test in magnetic field.Results: The Fano test yielded a 0.4% difference between simulation and expected result, which is similar to previous findings and sufficient for the purposes of this study. The angular dose–response map in all cases where the magnetic field is oriented orthogonal to the radiation beam is quite varied and can range from 0.89 to 1.08. Angular deviations as small as 3° can lead to dose–response changes in excess of 1%. When the magnetic field is parallel to the photon beam, the angular dose–response map is homogeneous and less than 1% below 1.0 T.Conclusions: Within a magnetic field‐oriented orthogonal to the radiation beam, the ionization chamber dose–response fluctuates greatly as a function of polar and azimuthal angle, where a parallel field yields a more homogeneous dose–response.
- 15 May 2015
- Published by Wiley in Medical Physics
- Vol. 42 (6Part1) , 2837-2840
Technical Note: Response measurement for select radiation detectors in magnetic fields
Purpose: Dose response to applied magnetic fields for ion chambers and solid state detectors has been investigated previously for the anticipated use in linear accelerator–magnetic resonance devices. In this investigation, the authors present the measured response of selected radiation detectors when the magnetic field is applied in the same direction as the radiation beam, i.e., a longitudinal magnetic field, to verify previous simulation only data. Methods: The dose response of a PR06C ion chamber, PTW60003 diamond detector, and IBA PFD diode detector is measured in a longitudinal magnetic field. The detectors are irradiated with buildup caps and their long axes either parallel or perpendicular to the incident photon beam. In each case, the magnetic field dose response is reported as the ratio of detector signals with to that without an applied longitudinal magnetic field. The magnetic field dose response for each unique orientation as a function of magnetic field strength was then compared to the previous simulation only studies. Results: The measured dose response of each detector in longitudinal magnetic fields shows no discernable response up to near 0.21 T. This result was expected and matches the previously published simulation only results, showing no appreciable dose response with magnetic field. Conclusions: Low field longitudinal magnetic fields have been shown to have little or no effect on the dose response of the detectors investigated and further lend credibility to previous simulation only studies.
- 15 May 2015
- Published by Wiley in Medical Physics
- Vol. 42 (6Part1) , 2837-2840
Technical Note: Response measurement for select radiation detectors in magnetic fields
Purpose: Dose response to applied magnetic fields for ion chambers and solid state detectors has been investigated previously for the anticipated use in linear accelerator–magnetic resonance devices. In this investigation, the authors present the measured response of selected radiation detectors when the magnetic field is applied in the same direction as the radiation beam, i.e., a longitudinal magnetic field, to verify previous simulation only data. Methods: The dose response of a PR06C ion chamber, PTW60003 diamond detector, and IBA PFD diode detector is measured in a longitudinal magnetic field. The detectors are irradiated with buildup caps and their long axes either parallel or perpendicular to the incident photon beam. In each case, the magnetic field dose response is reported as the ratio of detector signals with to that without an applied longitudinal magnetic field. The magnetic field dose response for each unique orientation as a function of magnetic field strength was then compared to the previous simulation only studies. Results: The measured dose response of each detector in longitudinal magnetic fields shows no discernable response up to near 0.21 T. This result was expected and matches the previously published simulation only results, showing no appreciable dose response with magnetic field. Conclusions: Low field longitudinal magnetic fields have been shown to have little or no effect on the dose response of the detectors investigated and further lend credibility to previous simulation only studies.
- 15 March 2013
- Published by Wiley in Medical Physics
- Vol. 40 (4) , 042102
Dose response of selected ion chambers in applied homogeneous transverse and longitudinal magnetic fields
Purpose:: The magnetic fields of an integrated MR‐Linac system will alter the paths of electrons that produce ions in the ionization chambers. The dose response of selected ion chambers is evaluated in the presence of varying transverse and longitudinal magnetic fields. The investigation is useful in calibration of therapeutic x‐ray beams associated with MR‐Linac systems.Methods:: The Monte Carlo code PENELOPE was used to model the irradiation of NE2571, and PR06C ionization chambers in the presence of a transverse and longitudinal (with respect to the photon beam) magnetic fields of varying magnitude. The long axis of each chamber was simulated both parallel and perpendicular to the incident photon beam for each magnetic field case. The dose deposited in each chamber for each case was compared to the case with zero magnetic field by means of a ratio. The PR06C chamber's response was measured in the presence of a transverse magnetic field with field strengths ranging from 0.0 to 0.2 T to compare to simulated results.Results:: The simulations and measured data show that in the presence of a transverse magnetic field there is a considerable dose response (maximum of 11% near 1.0 T in the ion chambers investigated, which depends on the magnitude of magnetic field, and relative orientation of the magnetic field, radiation beam, and ion chamber. Measurements made with the PR06C chamber verify these results in the region of measurement. In contrast, a longitudinal magnetic field produces only a slight increase in dose response (2% at 1.5 T) that rises slowly with increasing magnetic field and is seemingly independent of chamber orientation. Response trends were similar for the two ion chambers and relative orientations considered, but slight variations are present from chamber to chamber.Conclusions:: Care must be taken when making ion chamber measurements in a transverse magnetic field. Ion chamber responses vary not only with transverse field strength, but with chamber orientation and type, and can be considerable. Longitudinal magnetic fields influence ion chamber responses relatively little (2% at 1.5 T), and only at field strengths in excess of 1.0 T.
- 15 March 2013
- Published by Wiley in Medical Physics
- Vol. 40 (4) , 042102
Dose response of selected ion chambers in applied homogeneous transverse and longitudinal magnetic fields
Purpose:: The magnetic fields of an integrated MR‐Linac system will alter the paths of electrons that produce ions in the ionization chambers. The dose response of selected ion chambers is evaluated in the presence of varying transverse and longitudinal magnetic fields. The investigation is useful in calibration of therapeutic x‐ray beams associated with MR‐Linac systems.Methods:: The Monte Carlo code PENELOPE was used to model the irradiation of NE2571, and PR06C ionization chambers in the presence of a transverse and longitudinal (with respect to the photon beam) magnetic fields of varying magnitude. The long axis of each chamber was simulated both parallel and perpendicular to the incident photon beam for each magnetic field case. The dose deposited in each chamber for each case was compared to the case with zero magnetic field by means of a ratio. The PR06C chamber's response was measured in the presence of a transverse magnetic field with field strengths ranging from 0.0 to 0.2 T to compare to simulated results.Results:: The simulations and measured data show that in the presence of a transverse magnetic field there is a considerable dose response (maximum of 11% near 1.0 T in the ion chambers investigated, which depends on the magnitude of magnetic field, and relative orientation of the magnetic field, radiation beam, and ion chamber. Measurements made with the PR06C chamber verify these results in the region of measurement. In contrast, a longitudinal magnetic field produces only a slight increase in dose response (2% at 1.5 T) that rises slowly with increasing magnetic field and is seemingly independent of chamber orientation. Response trends were similar for the two ion chambers and relative orientations considered, but slight variations are present from chamber to chamber.Conclusions:: Care must be taken when making ion chamber measurements in a transverse magnetic field. Ion chamber responses vary not only with transverse field strength, but with chamber orientation and type, and can be considerable. Longitudinal magnetic fields influence ion chamber responses relatively little (2% at 1.5 T), and only at field strengths in excess of 1.0 T.