Hideki Fukano
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Hideki Fukano has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
Kazuma Ooshima
Graduate School of Natural Science and Technology, Okayama University, 3-1-1 Tsushima-naka, Kita-ku, Okayama 700-8530, Japan
2 shared publicationsMikihiro Kamada
Graduate School of Natural Science and Technology, Okayama University, 3-1-1 Tsushima-naka, Kita-ku, Okayama 700-8530, Japan
2 shared publicationsTakahito Mukai
Graduate School of Natural Science and Technology, Okayama University, 3-1-1 Tsushima-naka, Kita-ku, Okayama 700-8530, Japan
2 shared publicationsKazuki Yoshioka
Okayama University - Tsushima Campus, Okayama, Okayama, JAPAN
1 shared publication- Masashi Naora1 shared publication
Shiori Matsuoka
Graduate School of Natural Science and Technology, Okayama University, 3-1-1 Tsushima-naka, Kita-ku, Okayama 700-8530, Japan
1 shared publication
Latest Publications
- 1 May 2024
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 63 (5) , 05SP13
Multipoint temperature measurement system composed of fiber-optic Fabry–Perot interference sensors and a wavelength-division multiplexing filter
A multipoint optical-fiber remote temperature measurement system was developed using reflection-type sensors consisting of a Fabry–Perot interference (FPI) structure with good temperature characteristics combined with a wavelength-division multiplexing (WDM) filter. The FPI sensor was fabricated using a short temperature-sensing region sandwiched between single-mode fibers. FPI optical fibers and a WDM filter functioned as the temperature sensors and wavelength-selective optical source using an amplified spontaneous emission light source, respectively. This system was operated in a dense WDM configuration using an arrayed waveguide wavelength filter.
- 1 May 2024
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 63 (5) , 05SP13
Multipoint temperature measurement system composed of fiber-optic Fabry–Perot interference sensors and a wavelength-division multiplexing filter
A multipoint optical-fiber remote temperature measurement system was developed using reflection-type sensors consisting of a Fabry–Perot interference (FPI) structure with good temperature characteristics combined with a wavelength-division multiplexing (WDM) filter. The FPI sensor was fabricated using a short temperature-sensing region sandwiched between single-mode fibers. FPI optical fibers and a WDM filter functioned as the temperature sensors and wavelength-selective optical source using an amplified spontaneous emission light source, respectively. This system was operated in a dense WDM configuration using an arrayed waveguide wavelength filter.
- 1 May 2024
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 63 (5) , 05SP01
Fabry–Perot interference temperature sensor integrated high-power-laser optical fiber probe for laser ablation
In this study, an optical fiber probe with an extremely short integrated temperature sensor for high-power laser ablation was proposed and successfully fabricated. Both optical mode and wavelength multiplication were performed simultaneously using a double-clad fiber with a wavelength-division multiplication technique. The wavelength shift with temperature showed a linear relationship with a sensitivity of 10 pm/°C. High-power laser irradiation of 1000 mW or more using multimode transmission and fine temperature monitoring using single-mode transmission were performed simultaneously with a system response time of a few seconds. The laser wavelength selection and power variation can increase the variability of the heating region required for medical applications.
- 1 May 2024
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 63 (5) , 05SP01
Fabry–Perot interference temperature sensor integrated high-power-laser optical fiber probe for laser ablation
In this study, an optical fiber probe with an extremely short integrated temperature sensor for high-power laser ablation was proposed and successfully fabricated. Both optical mode and wavelength multiplication were performed simultaneously using a double-clad fiber with a wavelength-division multiplication technique. The wavelength shift with temperature showed a linear relationship with a sensitivity of 10 pm/°C. High-power laser irradiation of 1000 mW or more using multimode transmission and fine temperature monitoring using single-mode transmission were performed simultaneously with a system response time of a few seconds. The laser wavelength selection and power variation can increase the variability of the heating region required for medical applications.
- 24 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-2
High-Power Laser Irradiative Optical Fiber Probe Integrated with a Short Temperature Sensor for Laser Ablation
A novel optical fiber probe with a very short integrated temperature sensor for high-power laser ablation is proposed and was successfully fabricated. Both optical mode and wavelength multiplication were simultaneously performed using a double-clad fiber for laser irradiation and temperature monitoring.
- 24 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-2
High-Power Laser Irradiative Optical Fiber Probe Integrated with a Short Temperature Sensor for Laser Ablation
A novel optical fiber probe with a very short integrated temperature sensor for high-power laser ablation is proposed and was successfully fabricated. Both optical mode and wavelength multiplication were simultaneously performed using a double-clad fiber for laser irradiation and temperature monitoring.
- 24 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-2
Multi-point Optical Fiber Remote Temperature Measurement System by Combining Fabry–Perot-interference Sensors and a Wavelength Division Multiplexing Filter
A multi-point temperature sensing system was developed using reflection-type sensors consisting of a Fabry-Perot interference structure with good temperature characteristics. It can be simply fabricated using a short temperature-sensing region sandwiched between single-mode fibers. It was operated in a dense wavelength division multiplexing configuration using an arrayed waveguide filter.
- 24 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-2
Multi-point Optical Fiber Remote Temperature Measurement System by Combining Fabry–Perot-interference Sensors and a Wavelength Division Multiplexing Filter
A multi-point temperature sensing system was developed using reflection-type sensors consisting of a Fabry-Perot interference structure with good temperature characteristics. It can be simply fabricated using a short temperature-sensing region sandwiched between single-mode fibers. It was operated in a dense wavelength division multiplexing configuration using an arrayed waveguide filter.
- 16 June 2022
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 61 (SK) , SK1004
High-sensitivity multipoint refractive index measurement system composed of multimode interference sensors and arrayed waveguide wavelength filters
A multipoint sensing measurement system with high sensitivity was developed by combining multimode interference (MMI) sensors and a wavelength selection configuration. MMI optical fibers and an arrayed waveguide (AWG) wavelength filter work as refractive index sensors and wavelength selector, respectively. They were operated with a fine calibration technique using dual AWG wavelength filters and defined wavelength light from a tunable laser source. By employing narrow-core single-mode fibers for the input and output ports of the MMI, the optical fiber improved the average sensitivity up to 820 dB/RIU under multipoint sensing conditions.
- 16 June 2022
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 61 (SK) , SK1004
High-sensitivity multipoint refractive index measurement system composed of multimode interference sensors and arrayed waveguide wavelength filters
A multipoint sensing measurement system with high sensitivity was developed by combining multimode interference (MMI) sensors and a wavelength selection configuration. MMI optical fibers and an arrayed waveguide (AWG) wavelength filter work as refractive index sensors and wavelength selector, respectively. They were operated with a fine calibration technique using dual AWG wavelength filters and defined wavelength light from a tunable laser source. By employing narrow-core single-mode fibers for the input and output ports of the MMI, the optical fiber improved the average sensitivity up to 820 dB/RIU under multipoint sensing conditions.
- 1 January 2022
- Published by Optica Publishing Group
- p. CThP17F_02
A Simple and Short Temperature Sensor Integrated Optical Fiber Probe for Laser Ablation
A novel optical fiber probe with a very short integrated temperature sensor for laser ablation is proposed and successfully fabricated throughout this study. Laser irradiation and temperature monitoring were performed simultaneously using a wavelength-division-multiplexing technique.
- 1 January 2022
- Published by Optica Publishing Group
- p. CThP17F_02
A Simple and Short Temperature Sensor Integrated Optical Fiber Probe for Laser Ablation
A novel optical fiber probe with a very short integrated temperature sensor for laser ablation is proposed and successfully fabricated throughout this study. Laser irradiation and temperature monitoring were performed simultaneously using a wavelength-division-multiplexing technique.
- 17 June 2020
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 59 (SO) , SOOE02
Multipoint refractive index measurement using multimode interference-based fiber-optic sensors driven by an integrable tunable laser assembly
In this study, multipoint sensing techniques using multimode interference-based fiber-optic sensors were investigated. Here, systems were operated using a wavelength-selective optical filter and a defined-wavelength laser light from an integrable tunable laser assembly (ITLA). By changing the wavelength of the ITLA, measurement of the multipoint refractive index was achieved with high sensitivity.
- 17 June 2020
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 59 (SO) , SOOE02
Multipoint refractive index measurement using multimode interference-based fiber-optic sensors driven by an integrable tunable laser assembly
In this study, multipoint sensing techniques using multimode interference-based fiber-optic sensors were investigated. Here, systems were operated using a wavelength-selective optical filter and a defined-wavelength laser light from an integrable tunable laser assembly (ITLA). By changing the wavelength of the ITLA, measurement of the multipoint refractive index was achieved with high sensitivity.
- 15 June 2020
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 59 (SO) , SOOD05
Fiber-optic temperature sensor with selectively enhanced Fabry–Perot interference using focusing effect of graded-index fiber for cryotherapy
In this study, we developed a Fabry–Perot (FP) interference temperature sensor comprising a glass capillary and a graded-index (GI) fiber for cryotherapy. The sensor comprises a single-mode fiber attached to a glass capillary with a GI fiber. This structure can selectively enhance the specific FP interference and has a large extinction ratio. The sensor demonstrates excellent characteristics from 50 °C to −43 °C with a linear relationship between temperature and dip wavelength.
- 15 June 2020
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 59 (SO) , SOOD05
Fiber-optic temperature sensor with selectively enhanced Fabry–Perot interference using focusing effect of graded-index fiber for cryotherapy
In this study, we developed a Fabry–Perot (FP) interference temperature sensor comprising a glass capillary and a graded-index (GI) fiber for cryotherapy. The sensor comprises a single-mode fiber attached to a glass capillary with a GI fiber. This structure can selectively enhance the specific FP interference and has a large extinction ratio. The sensor demonstrates excellent characteristics from 50 °C to −43 °C with a linear relationship between temperature and dip wavelength.
- 13 July 2018
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 57 (8S2) , 08PE04
Ultrasensitive fiber-optic refractive index sensor based on multimode interference with fiber-loop configuration
A novel ultrasensitive fiber-optic refractive index (RI) sensor is proposed and experimentally demonstrated for solute concentration measurement. To realize higher RI sensitivity, we insert a fiber-optic multimode interference sensor into a fiber-loop configuration to produce a steeper spectrum. The interaction with multimode interference is repeated and enhanced by the fiber loop, resulting in an output spectrum steeper than that obtained without a fiber loop. An ultrahigh RI resolution of 3.06 × 10 −7 refractive index unit (RIU) is obtained in the steepest RI range, and it is higher by approximately 53.6 times. We apply this sensor to the measurement of the concentration of a sodium chloride solution and obtain a resolution of 1.87 × 10 −4 wt %. This result agrees well with the RI measurement result. The results show that this ultrasensitive RI sensor has the potential for detection applications in the chemical and biomedical fields.
- 13 July 2018
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 57 (8S2) , 08PE04
Ultrasensitive fiber-optic refractive index sensor based on multimode interference with fiber-loop configuration
A novel ultrasensitive fiber-optic refractive index (RI) sensor is proposed and experimentally demonstrated for solute concentration measurement. To realize higher RI sensitivity, we insert a fiber-optic multimode interference sensor into a fiber-loop configuration to produce a steeper spectrum. The interaction with multimode interference is repeated and enhanced by the fiber loop, resulting in an output spectrum steeper than that obtained without a fiber loop. An ultrahigh RI resolution of 3.06 × 10 −7 refractive index unit (RIU) is obtained in the steepest RI range, and it is higher by approximately 53.6 times. We apply this sensor to the measurement of the concentration of a sodium chloride solution and obtain a resolution of 1.87 × 10 −4 wt %. This result agrees well with the RI measurement result. The results show that this ultrasensitive RI sensor has the potential for detection applications in the chemical and biomedical fields.