David F. Plusquellic
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
David F. Plusquellic has a total of 70 co-authors. Here are the top co-authors by number of shared publications:
- Jasper R. Stroud
National Institute of Standards and Technology, Boulder, USA
10 shared publications - David A. Long
National Institute of Standards and Technology
4 shared publications Kevin O. Douglass
National Institute of Standards and Technology
4 shared publicationsChristian W. Müller
Department of Chemistry, Purdue University, West Lafayette, Indiana 47907, United States
3 shared publicationsJ. T. Hodges
3 shared publications- Stephen John Maxwell
College of Science and Engineering, James Cook University, Cairns, QLD 4878, Australia
3 shared publications
Latest Publications
- 30 March 2026
- Published by Optica Publishing Group in Optics Letters
- Vol. 51 (7) , 1975-1978
Cavity-enhanced UV combs generated by sum frequency mixing with near-IR chirped-pulse electro-optic combs for Rb atom sensing at 323 nm
A chirped-pulse electro-optic (EO) dual comb system operating near 821 nm is used to generate cavity-enhanced dual combs in the ultraviolet (UV) region near 323 nm with an optical bandwidth of up to 90 GHz. The UV combs result from intracavity sum frequency mixing of the non-resonant near-IR combs with a cavity-enhanced field at 532 nm in a nonlinear crystal. The cavity is pumped with 1 W at 532 nm and seeded with less than 10 mW in the near-IR region to generate a few μW of UV power within a detection bandwidth of 2 P 3/2 ←5 2 S 1/2 ). This method is easily extendable across the 300 nm to 400 nm region using telecom and near-IR dual EO comb sources for seeding.
- 30 March 2026
- Published by Optica Publishing Group in Optics Letters
- Vol. 51 (7) , 1975-1978
Cavity-enhanced UV combs generated by sum frequency mixing with near-IR chirped-pulse electro-optic combs for Rb atom sensing at 323 nm
A chirped-pulse electro-optic (EO) dual comb system operating near 821 nm is used to generate cavity-enhanced dual combs in the ultraviolet (UV) region near 323 nm with an optical bandwidth of up to 90 GHz. The UV combs result from intracavity sum frequency mixing of the non-resonant near-IR combs with a cavity-enhanced field at 532 nm in a nonlinear crystal. The cavity is pumped with 1 W at 532 nm and seeded with less than 10 mW in the near-IR region to generate a few μW of UV power within a detection bandwidth of 2 P 3/2 ←5 2 S 1/2 ). This method is easily extendable across the 300 nm to 400 nm region using telecom and near-IR dual EO comb sources for seeding.
- Open Access
- 1 December 2023
- Published by MDPI AG in Remote Sensing
- Vol. 15 (23) , 5595
Multi-Frequency Differential Absorption LIDAR (DIAL) System for Aerosol and Cloud Retrievals of CO2/H2O and CH4/H2O
We discuss a remote sensing system that is used to simultaneously detect range-resolved differential absorption LIDAR (light detection and ranging; DIAL) signals and integrated path differential absorption LIDAR signals (IPDA LIDAR) from aerosol targets for ranges up to 22 km. The DIAL/IPDA LIDAR frequency converter consists of an OPO pumped at 1064 nm to produce light at 1.6 μm and operates at 100 Hz pulse repetition frequency. The probe light is free space coupled to a movable platform that contains one transmitter and two receiver telescopes. Hybrid photon counting/current systems increase the dynamic range for detection by two orders of magnitude. Range resolved and column integrated dry-air CO2 and CH4 mixing ratios are obtained from line shape fits of CO2 and CH4 centered at 1602.2 nm and 1645.5 nm, respectively, and measured at 10 different frequencies over ≈1.3 cm−1 bandwidth. The signal-to-noise ratios (SNRs) of the IPDA LIDAR returns from cloud aerosols approach 1000:1 and the uncertainties in the mixing ratios weighted according to the integrated counts over the cloud segments range from 0.1% to 1%. The range-averaged DIAL mixing ratios are in good agreement with the IPDA LIDAR mixing ratios at the 1% to 2% level for both CO2 and CH4. These results can serve as a validation method for future active and passive satellite observational systems.
- 1 December 2023
- Published by MDPI AG in Remote Sensing
- Vol. 15 (23) , 5595
Open AccessMulti-Frequency Differential Absorption LIDAR (DIAL) System for Aerosol and Cloud Retrievals of CO2/H2O and CH4/H2O
We discuss a remote sensing system that is used to simultaneously detect range-resolved differential absorption LIDAR (light detection and ranging; DIAL) signals and integrated path differential absorption LIDAR signals (IPDA LIDAR) from aerosol targets for ranges up to 22 km. The DIAL/IPDA LIDAR frequency converter consists of an OPO pumped at 1064 nm to produce light at 1.6 μm and operates at 100 Hz pulse repetition frequency. The probe light is free space coupled to a movable platform that contains one transmitter and two receiver telescopes. Hybrid photon counting/current systems increase the dynamic range for detection by two orders of magnitude. Range resolved and column integrated dry-air CO2 and CH4 mixing ratios are obtained from line shape fits of CO2 and CH4 centered at 1602.2 nm and 1645.5 nm, respectively, and measured at 10 different frequencies over ≈1.3 cm−1 bandwidth. The signal-to-noise ratios (SNRs) of the IPDA LIDAR returns from cloud aerosols approach 1000:1 and the uncertainties in the mixing ratios weighted according to the integrated counts over the cloud segments range from 0.1% to 1%. The range-averaged DIAL mixing ratios are in good agreement with the IPDA LIDAR mixing ratios at the 1% to 2% level for both CO2 and CH4. These results can serve as a validation method for future active and passive satellite observational systems.
- Open Access
- 1 September 2023
- Published by AIP Publishing in APL Photonics
- Vol. 8 (9)
High accuracy, high dynamic range optomechanical accelerometry enabled by dual comb spectroscopy
Cavity optomechanical sensors can offer exceptional sensitivity; however, interrogating the cavity motion with high accuracy and dynamic range has proven to be challenging. Here, we employ a dual optical frequency comb spectrometer to readout a microfabricated cavity optomechanical accelerometer, allowing for rapid simultaneous measurements of the cavity’s displacement, finesse, and coupling at accelerations up to 24 g (236 m/s2). With this approach, we have achieved a displacement sensitivity of 2 fm Hz−1/2, a measurement rate of 100 kHz, and a dynamic range of 7.6 × 105, which is the highest we are aware of for a microfabricated cavity optomechanical sensor. In addition, comparisons of our optomechanical sensor coupled directly to a commercial reference accelerometer show agreement at the 0.5% level, a value that is limited by the reference’s reported uncertainty. Furthermore, the methods described herein are not limited to accelerometry but rather can be readily applied to nearly any optomechanical sensor where the combination of high speed, dynamic range, and sensitivity is expected to be enabling.
- 1 September 2023
- Published by AIP Publishing in APL Photonics
- Vol. 8 (9)
Open AccessHigh accuracy, high dynamic range optomechanical accelerometry enabled by dual comb spectroscopy
Cavity optomechanical sensors can offer exceptional sensitivity; however, interrogating the cavity motion with high accuracy and dynamic range has proven to be challenging. Here, we employ a dual optical frequency comb spectrometer to readout a microfabricated cavity optomechanical accelerometer, allowing for rapid simultaneous measurements of the cavity’s displacement, finesse, and coupling at accelerations up to 24 g (236 m/s2). With this approach, we have achieved a displacement sensitivity of 2 fm Hz−1/2, a measurement rate of 100 kHz, and a dynamic range of 7.6 × 105, which is the highest we are aware of for a microfabricated cavity optomechanical sensor. In addition, comparisons of our optomechanical sensor coupled directly to a commercial reference accelerometer show agreement at the 0.5% level, a value that is limited by the reference’s reported uncertainty. Furthermore, the methods described herein are not limited to accelerometry but rather can be readily applied to nearly any optomechanical sensor where the combination of high speed, dynamic range, and sensitivity is expected to be enabling.
- Open Access
- 31 August 2023
- Published by MDPI AG in Remote Sensing
- Vol. 15 (17) , 4283
Study on Local Power Plant Emissions Using Multi-Frequency Differential Absorption LIDAR and Real-Time Plume Tracking
We present a new fiber-amplifier-based differential absorption light detection and ranging (DIAL) system for range-resolved detection of carbon dioxide (CO2) and water vapor (H2O) over a range of a few kilometers. The fiber amplifier chain is seeded with a 7.14 kHz fast-switching high-spectral purity wavelength source near 1572 nm to cover ten different frequencies across the CO2/H2O line pair in ≈1.4 ms. We demonstrate the system in a study of CO2 emissions from a local power plant in Boulder, CO, USA. We use real-time wind information to predict the plume location for tracking and modeling of the CO2 emission rate to compare with the reported data from the power plant over a 13 h period. There is overall agreement with the reported burn rate, but we see periods of bias towards underestimation of the CO2 emission rate. We attribute the dropout periods to uncertainties between the measured and the plant’s local wind speed data that impact both the tracking location and the plume model predictions. Upcoming studies that will make use of real-time Doppler wind data are expected to significantly decrease these uncertainties.
- 31 August 2023
- Published by MDPI AG in Remote Sensing
- Vol. 15 (17) , 4283
Open AccessStudy on Local Power Plant Emissions Using Multi-Frequency Differential Absorption LIDAR and Real-Time Plume Tracking
We present a new fiber-amplifier-based differential absorption light detection and ranging (DIAL) system for range-resolved detection of carbon dioxide (CO2) and water vapor (H2O) over a range of a few kilometers. The fiber amplifier chain is seeded with a 7.14 kHz fast-switching high-spectral purity wavelength source near 1572 nm to cover ten different frequencies across the CO2/H2O line pair in ≈1.4 ms. We demonstrate the system in a study of CO2 emissions from a local power plant in Boulder, CO, USA. We use real-time wind information to predict the plume location for tracking and modeling of the CO2 emission rate to compare with the reported data from the power plant over a 13 h period. There is overall agreement with the reported burn rate, but we see periods of bias towards underestimation of the CO2 emission rate. We attribute the dropout periods to uncertainties between the measured and the plant’s local wind speed data that impact both the tracking location and the plume model predictions. Upcoming studies that will make use of real-time Doppler wind data are expected to significantly decrease these uncertainties.
- 19 July 2022
- Published by Optica Publishing Group in Optics Letters
- Vol. 47 (15) , 3716-3719
Dual chirped-pulse electro-optical frequency comb method for simultaneous molecular spectroscopy and dynamics studies: formic acid in the terahertz region
An electro-optic dual-comb system based on chirped-pulse waveforms is used to simultaneously acquire temporally magnified rapid passage signals and normal spectral line shapes from the back-transformation to the time domain. Multi-heterodyne terahertz (THz) wave generation and detection is performed with the difference frequency mixing of two free-running lasers. The method is used to obtain THz spectra of formic acid in the 10 cm-1 to 20 cm-1 (300 GHz–600 GHz) region over a range of pressures. The method is widely applicable across other spectral regions for investigations of the transient dynamics and spectroscopy of molecular systems.
- 19 July 2022
- Published by Optica Publishing Group in Optics Letters
- Vol. 47 (15) , 3716-3719
Dual chirped-pulse electro-optical frequency comb method for simultaneous molecular spectroscopy and dynamics studies: formic acid in the terahertz region
An electro-optic dual-comb system based on chirped-pulse waveforms is used to simultaneously acquire temporally magnified rapid passage signals and normal spectral line shapes from the back-transformation to the time domain. Multi-heterodyne terahertz (THz) wave generation and detection is performed with the difference frequency mixing of two free-running lasers. The method is used to obtain THz spectra of formic acid in the 10 cm-1 to 20 cm-1 (300 GHz–600 GHz) region over a range of pressures. The method is widely applicable across other spectral regions for investigations of the transient dynamics and spectroscopy of molecular systems.
- Open Access
A dual chirped-pulse electro-optical frequency comb method for simultaneous molecular spectroscopy and dynamics studies: Formic acid in the THz region
An electro-optic dual comb system based on chirped-pulse waveforms is used to simultaneously acquire temporally magnified rapid passage signals and normal spectral line shapes from the back-transformation to the time domain. Multi-heterodyne THz wave generation and detection is performed with the difference frequency mixing of two free-running lasers. The method is used to obtain THz spectra of formic acid in the 10 cm-1 to 20 cm-1 (300 GHz to 600 GHz) region over a range of pressures. The method is widely applicable across other spectral regions for investigations of the transient dynamics and spectroscopy of molecular systems.
Open AccessA dual chirped-pulse electro-optical frequency comb method for simultaneous molecular spectroscopy and dynamics studies: Formic acid in the THz region
An electro-optic dual comb system based on chirped-pulse waveforms is used to simultaneously acquire temporally magnified rapid passage signals and normal spectral line shapes from the back-transformation to the time domain. Multi-heterodyne THz wave generation and detection is performed with the difference frequency mixing of two free-running lasers. The method is used to obtain THz spectra of formic acid in the 10 cm-1 to 20 cm-1 (300 GHz to 600 GHz) region over a range of pressures. The method is widely applicable across other spectral regions for investigations of the transient dynamics and spectroscopy of molecular systems.
- Open Access
High dynamic range electro-optic dual-comb interrogation of optomechanical sensors
An interleaved, chirped electro-optic dual comb system is demonstrated for rapid, high dynamic range measurements of cavity optomechanical sensors. This approach allows for the cavity displacements to be interrogated at measurement times as fast as 10 {\mu}s over ranges far larger than can be achieved with alternative methods. While the performance of this novel readout approach is evaluated with an optomechanical accelerometer, this method is applicable to a wide range of applications including temperature, pressure, and humidity sensing as well as acoustics and molecular spectroscopy.
Open AccessHigh dynamic range electro-optic dual-comb interrogation of optomechanical sensors
An interleaved, chirped electro-optic dual comb system is demonstrated for rapid, high dynamic range measurements of cavity optomechanical sensors. This approach allows for the cavity displacements to be interrogated at measurement times as fast as 10 {\mu}s over ranges far larger than can be achieved with alternative methods. While the performance of this novel readout approach is evaluated with an optomechanical accelerometer, this method is applicable to a wide range of applications including temperature, pressure, and humidity sensing as well as acoustics and molecular spectroscopy.
- 24 January 2022
- Published by AIP Publishing in The Journal of Chemical Physics
- Vol. 156 (4) , 044302
Difference-frequency chirped-pulse dual-comb generation in the THz region: Temporal magnification of the quantum dynamics of water vapor lines by >60 000
A new difference-frequency method based on electro-optic phase modulators (EOMs) and two free-running lasers is reported to perform chirped-pulse dual-comb spectroscopy in the THz region. A variation of a near-IR interleaving scheme we recently reported has been developed to interleave the EOMs' orders and sidebands and to map THz comb teeth into the radio-frequency region below 1 MHz. The down-converted comb teeth are shown to have transform limited widths of 1 Hz over a 1 sec time scale. The dual chirp-pulsed scheme is used to measure the complex line shapes of two water vapor lines below 600 GHz and to temporally magnify the effects of rapid passage by more than 60,000. For the 11,0←10,1 transition in H2O, a pressure dependent phase perturbation is observed in the rapid passage response over the magnified time scale in contrast to a uniform line shape transformation observed for the 21,1←20,2 transition of D2O. The possible origins for this anomalous behavior are modeled and discussed. The method is applicable to any region where difference or sum frequency waves can be generated.
- 24 January 2022
- Published by AIP Publishing in The Journal of Chemical Physics
- Vol. 156 (4) , 044302
Difference-frequency chirped-pulse dual-comb generation in the THz region: Temporal magnification of the quantum dynamics of water vapor lines by >60 000
A new difference-frequency method based on electro-optic phase modulators (EOMs) and two free-running lasers is reported to perform chirped-pulse dual-comb spectroscopy in the THz region. A variation of a near-IR interleaving scheme we recently reported has been developed to interleave the EOMs' orders and sidebands and to map THz comb teeth into the radio-frequency region below 1 MHz. The down-converted comb teeth are shown to have transform limited widths of 1 Hz over a 1 sec time scale. The dual chirp-pulsed scheme is used to measure the complex line shapes of two water vapor lines below 600 GHz and to temporally magnify the effects of rapid passage by more than 60,000. For the 11,0←10,1 transition in H2O, a pressure dependent phase perturbation is observed in the rapid passage response over the magnified time scale in contrast to a uniform line shape transformation observed for the 21,1←20,2 transition of D2O. The possible origins for this anomalous behavior are modeled and discussed. The method is applicable to any region where difference or sum frequency waves can be generated.
- 1 January 2022
- Published by Optica Publishing Group
- Vol. 9, AM2K.3
Range resolved CO2 measurements over 3 km using a 10-point fiber-based differential-absorption LIDAR (DIAL) system
We present a multi-frequency DIAL system based on a fast-switching wavelength source and fiber optic amplification to acquire range-resolved dry-air CO2 concentrations over the city of Boulder, Colorado USA.(/p)(p)Official contribution of the NIST; not subject to copyright in the United States.
- 1 January 2022
- Published by Optica Publishing Group
- Vol. 9, AM2K.3
Range resolved CO2 measurements over 3 km using a 10-point fiber-based differential-absorption LIDAR (DIAL) system
We present a multi-frequency DIAL system based on a fast-switching wavelength source and fiber optic amplification to acquire range-resolved dry-air CO2 concentrations over the city of Boulder, Colorado USA.(/p)(p)Official contribution of the NIST; not subject to copyright in the United States.
- 1 January 2022
- Published by Optica Publishing Group
- Vol. 3, STh4O.2
Dual Chirped-Pulse Electro-Optic Comb Generation in the THz Region: Spanning the Spectroscopic and Quantum Dynamics Domains
A new THz difference-frequency chirped-pulse dual-comb method based on electro-optic phase modulators (EOMs) and two near-visible continuous wave lasers is used to perform high resolution spectroscopy and to magnify the rapid passage signal response. Official contribution of the National Institute of Standards and Technology; not subject to copyright in the United States.
- 1 January 2022
- Published by Optica Publishing Group
- Vol. 3, STh4O.2
Dual Chirped-Pulse Electro-Optic Comb Generation in the THz Region: Spanning the Spectroscopic and Quantum Dynamics Domains
A new THz difference-frequency chirped-pulse dual-comb method based on electro-optic phase modulators (EOMs) and two near-visible continuous wave lasers is used to perform high resolution spectroscopy and to magnify the rapid passage signal response. Official contribution of the National Institute of Standards and Technology; not subject to copyright in the United States.