Johnathan Travis
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Johnathan Travis has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Alan Holloway
School of Engineering & Built Environment, Sheffield Hallam University, City Campus, Howard Street, Sheffield S1 1WB, UK
3 shared publications - Ben Richard Hughes
Department of Mechanical Engineering, University of Sheffield, Sheffield S10 2TN, UK
3 shared publications - Reza Saatchi
School of Engineering and Built Environment, Sheffield Hallam University, Sheffield S1 1WB, UK
3 shared publications - Robert L. Evans
Research & Innovation Office, Cranfield University, Cranfield Campus, College Road, Cranfield MK43 0AL, UK
3 shared publications - Ruth N. Kingshott
Sheffield Children’s NHS Foundation Trust, Clarkson Street, Broomhall, Sheffield S10 2TH, UK
3 shared publications - William Daw
Sheffield Children’s NHS Foundation Trust, Clarkson Street, Broomhall, Sheffield S10 2TH, UK
3 shared publications
Latest Publications
- Open Access
- 9 June 2025
- Published by MDPI AG in Technologies
- Vol. 13 (6) , 237
Design, Development, and Evaluation of a Contactless Respiration Rate Measurement Device Utilizing a Self-Heating Thermistor
The respiration rate (RR) is an important vital sign for early detection of health deterioration in critically unwell patients. Its current measurement has limitations, relying on visual counting of chest movements. The design of a new RR measurement device utilizing a self-heating thermistor is described. The thermistor is integrated into a hand-held air chamber with a funnel attachment to sensitively detect respiratory airflow. The exhaled respiratory airflow reduces the temperature of the thermistor that is kept at a preset temperature, and its temperature recovers during inhalation. A microcontroller provides signal processing, while its display screen shows the respiratory signal and RR. The device was evaluated on 27 healthy adult volunteers, with a mean age of 32.8 years (standard deviation of 8.6 years). The RR measurements from the device were compared with the visual counting of chest movements, and the contact method of inductance plethysmography that was implemented using a commercial device (SOMNOtouch™ RESP). Statistical analysis, e.g., correlations were performed. The RR measurements from the new device and SOMNOtouch™ RESP, averaged across the 27 participants, were 14.6 breaths per minute (bpm) and 14.0 bpm, respectively. The device has a robust operation, is easy to use, and provides an objective measure of the RR in a noncontact manner.
- 9 June 2025
- Published by MDPI AG in Technologies
- Vol. 13 (6) , 237
Open AccessDesign, Development, and Evaluation of a Contactless Respiration Rate Measurement Device Utilizing a Self-Heating Thermistor
The respiration rate (RR) is an important vital sign for early detection of health deterioration in critically unwell patients. Its current measurement has limitations, relying on visual counting of chest movements. The design of a new RR measurement device utilizing a self-heating thermistor is described. The thermistor is integrated into a hand-held air chamber with a funnel attachment to sensitively detect respiratory airflow. The exhaled respiratory airflow reduces the temperature of the thermistor that is kept at a preset temperature, and its temperature recovers during inhalation. A microcontroller provides signal processing, while its display screen shows the respiratory signal and RR. The device was evaluated on 27 healthy adult volunteers, with a mean age of 32.8 years (standard deviation of 8.6 years). The RR measurements from the device were compared with the visual counting of chest movements, and the contact method of inductance plethysmography that was implemented using a commercial device (SOMNOtouch™ RESP). Statistical analysis, e.g., correlations were performed. The RR measurements from the new device and SOMNOtouch™ RESP, averaged across the 27 participants, were 14.6 breaths per minute (bpm) and 14.0 bpm, respectively. The device has a robust operation, is easy to use, and provides an objective measure of the RR in a noncontact manner.
- Open Access
- 14 April 2025
- Published by MDPI AG in Preprints.org
Design, Development and Evaluation of a Contactless Respiration Rate Measurement Device Utilising a Self-Heating Thermistor
Respiration rate (RR) is an important vital sign for early detection of health deterioration in critically unwell patients. Its measurement is currently subjective, relying on visual counting of chest movements. The design of a new RR measurement device utilising a self-heating thermistor as its sensing element is described. The thermistor is situated in a hand-held air chamber with a funnel attachment that detects respiratory airflow up to 30 cm from the face. The exhaled respiratory airflow reduces the temperature of the thermistor, and its temperature recovers during inhalation. A microcontroller provides signal processing while its display screen shows the respiratory signal and RR. The device has been evaluated on 27 healthy adult volunteers, mean age 32.8 years (standard deviation 8.6 years). The RR readings from the device were compared with the visual counting of chest movements and the contact method of inductance plethysmography implemented using a commercial device (SOMNOtouch™ RESP). The RR readings from the new device and SOMNOtouch™ RESP, averaged across the 27 participants, were 14.6 breaths per minute (bpm) and 14.0 bpm respectively. The device has a robust operation, is easy to use and gives an objective measure of RR in a non-contact manner.
- 14 April 2025
- Published by MDPI AG in Preprints.org
Open AccessDesign, Development and Evaluation of a Contactless Respiration Rate Measurement Device Utilising a Self-Heating Thermistor
Respiration rate (RR) is an important vital sign for early detection of health deterioration in critically unwell patients. Its measurement is currently subjective, relying on visual counting of chest movements. The design of a new RR measurement device utilising a self-heating thermistor as its sensing element is described. The thermistor is situated in a hand-held air chamber with a funnel attachment that detects respiratory airflow up to 30 cm from the face. The exhaled respiratory airflow reduces the temperature of the thermistor, and its temperature recovers during inhalation. A microcontroller provides signal processing while its display screen shows the respiratory signal and RR. The device has been evaluated on 27 healthy adult volunteers, mean age 32.8 years (standard deviation 8.6 years). The RR readings from the device were compared with the visual counting of chest movements and the contact method of inductance plethysmography implemented using a commercial device (SOMNOtouch™ RESP). The RR readings from the new device and SOMNOtouch™ RESP, averaged across the 27 participants, were 14.6 breaths per minute (bpm) and 14.0 bpm respectively. The device has a robust operation, is easy to use and gives an objective measure of RR in a non-contact manner.
- 14 May 2020
- Published by ASME International in Journal of Medical Devices
- Vol. 14 (3)
A Novel, Contactless, Portable “Spot-Check” Device Accurately Measures Respiratory Rate
Respiratory rate (RR) is an important vital sign used in the initial and ongoing assessment of acutely ill patients. It is also used as a predictor of serious deterioration in a patient's clinical condition. Convenient electronic devices exist for measurement of pulse, blood pressure, oxygen saturation, and temperature. Although devices which measure RR exist, none has entered everyday clinical practice. We have developed a contactless portable respiratory rate monitor (CPRM) and evaluated the agreement in respiratory rate measurements between existing methods and our new device. The CPRM uses thermal anemometry to measure breath signals during inspiration and expiration. RR data were collected from 52 healthy adult volunteers using respiratory inductance plethysmography (RIP) bands (established contact method), visual counting of chest movements (established noncontact method), and the CPRM (new method), simultaneously. Two differently shaped funnel attachments to the CPRM were evaluated for each volunteer. Data showed a good agreement between measurements from the CPRM and the gold standard RIP, with intraclass correlation coefficient (ICC): 0.836, mean difference 0.46 and 95% limits of agreement of −5.90 to 6.83. When separate air inlet funnels of the CPRM were analyzed, stronger agreement was seen with an elliptical air inlet; ICC 0.908, mean difference 0.37 with 95% limits of agreement −4.35 to 5.08. A contactless device for accurately and quickly measuring respiratory rate will be an important triage tool in the clinical assessment of patients. More testing is needed to explore the reasons for outlying measurements and to evaluate in the clinical setting.
- 14 May 2020
- Published by ASME International in Journal of Medical Devices
- Vol. 14 (3)
A Novel, Contactless, Portable “Spot-Check” Device Accurately Measures Respiratory Rate
Respiratory rate (RR) is an important vital sign used in the initial and ongoing assessment of acutely ill patients. It is also used as a predictor of serious deterioration in a patient's clinical condition. Convenient electronic devices exist for measurement of pulse, blood pressure, oxygen saturation, and temperature. Although devices which measure RR exist, none has entered everyday clinical practice. We have developed a contactless portable respiratory rate monitor (CPRM) and evaluated the agreement in respiratory rate measurements between existing methods and our new device. The CPRM uses thermal anemometry to measure breath signals during inspiration and expiration. RR data were collected from 52 healthy adult volunteers using respiratory inductance plethysmography (RIP) bands (established contact method), visual counting of chest movements (established noncontact method), and the CPRM (new method), simultaneously. Two differently shaped funnel attachments to the CPRM were evaluated for each volunteer. Data showed a good agreement between measurements from the CPRM and the gold standard RIP, with intraclass correlation coefficient (ICC): 0.836, mean difference 0.46 and 95% limits of agreement of −5.90 to 6.83. When separate air inlet funnels of the CPRM were analyzed, stronger agreement was seen with an elliptical air inlet; ICC 0.908, mean difference 0.37 with 95% limits of agreement −4.35 to 5.08. A contactless device for accurately and quickly measuring respiratory rate will be an important triage tool in the clinical assessment of patients. More testing is needed to explore the reasons for outlying measurements and to evaluate in the clinical setting.