Manfred Horn
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Manfred Horn has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
F Oscco
Faculty of Sciences, Universidad Nacional de Ingeniería, Av. Tupac Amaru 210, Lima 25, Peru
1 shared publicationG Tonello
Departamento de Luminotecnia, Luz y Visión, Universidad Nacional de Tucumán-CONICET, S. M. de Tucumán- Argentina
1 shared publication- Gilles Lefebvre
Centre for Studies and Thermal, Environment and Systems Research, University Research Institute of Créteil-Vitry, University Paris-Est, 61, General de Gaulle Avenue, 94000 Créteil, France
1 shared publication H F Ríos
Facultad de Ciencias, Universidad Nacional de Ingeniería, Av. Túpac Amaru 210 Rímac, Lima 25, Peru
1 shared publicationJ O Molina
Facultad de Ciencias, Universidad Nacional de Ingeniería, Av. Túpac Amaru 210 Rímac, Lima 25, Peru
1 shared publication- Juan Omar Molina Fuertes
Facultad de Ciencias, Universidad Nacional de Ingeniería, Lima, Peru
1 shared publication
Latest Publications
- Open Access
- 1 June 2023
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 2538 (1) , 012008
Evaluation of the perception of visual comfort, reading ability, color appearance, and global preference with respect to the CCT and the illuminance, of a university audience
With the aim of knowing the perception of a university audience of four aspects of lighting: visual comfort, reading ability, color appearance and global preference, 40 volunteers were surveyed, sitting in front of a cubicle, which was illuminated by 12 different states of lighting. The lighting was a combination of illuminances of 100 lx, 200 lx, 400 lx or 600 lx, and a CCT of 3500 K, 5000 K, or 6500 K. The different states of lighting were presented one after another randomly. The results indicate that the CCT does not have a significant influence on visual comfort, reading ability, and global preference and that these aspects depend only on the illuminance: observers prefer illuminances of 400 lx and 600 lx, with no significant difference between them. The color appearance aspect is influenced by illuminance and CCT: observers prefer illuminance values of 400 lx or 600 lx combined with CCTs of 5000 K or 6500 K.
- 1 June 2023
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 2538 (1) , 012008
Open AccessEvaluation of the perception of visual comfort, reading ability, color appearance, and global preference with respect to the CCT and the illuminance, of a university audience
With the aim of knowing the perception of a university audience of four aspects of lighting: visual comfort, reading ability, color appearance and global preference, 40 volunteers were surveyed, sitting in front of a cubicle, which was illuminated by 12 different states of lighting. The lighting was a combination of illuminances of 100 lx, 200 lx, 400 lx or 600 lx, and a CCT of 3500 K, 5000 K, or 6500 K. The different states of lighting were presented one after another randomly. The results indicate that the CCT does not have a significant influence on visual comfort, reading ability, and global preference and that these aspects depend only on the illuminance: observers prefer illuminances of 400 lx and 600 lx, with no significant difference between them. The color appearance aspect is influenced by illuminance and CCT: observers prefer illuminance values of 400 lx or 600 lx combined with CCTs of 5000 K or 6500 K.
- Open Access
- 1 March 2021
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1841 (1) , 012011
Thermophysical characterization of vernacular wall materials: measurements of specific heat and density
This study presents locally implemented measurement arrangements to determine thermophysical properties, such as the density and specific heat of adobe and sillar (ignimbrite), materials widely used in the walls of high Andean houses in Peru. The values of these properties are unknown, but they are crucial as input variables of dynamic simulation programs to determine the thermal behavior and demand of the heating energy of houses. The experimental setup was referenced to international standards, such as ASTM D7263 and ASTM D4611, and used an open-source Arduino microcontroller. The evaluations were also conducted with the transient conditions of heat flow, with adobe and sillar obtaining densities of 1570 ± 62 kg⋅m−3 and 1338 ± 20 kg⋅m−3 and specific heats of 1209 ± 93 J⋅kg−1⋅K−1 and 1800 ± 96 J⋅kg−1⋅K−1, respectively. The results suggest to carry out more measurements, especially of specific heat given the scarce local and international information on vernacular building materials.
- 1 March 2021
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1841 (1) , 012011
Open AccessThermophysical characterization of vernacular wall materials: measurements of specific heat and density
This study presents locally implemented measurement arrangements to determine thermophysical properties, such as the density and specific heat of adobe and sillar (ignimbrite), materials widely used in the walls of high Andean houses in Peru. The values of these properties are unknown, but they are crucial as input variables of dynamic simulation programs to determine the thermal behavior and demand of the heating energy of houses. The experimental setup was referenced to international standards, such as ASTM D7263 and ASTM D4611, and used an open-source Arduino microcontroller. The evaluations were also conducted with the transient conditions of heat flow, with adobe and sillar obtaining densities of 1570 ± 62 kg⋅m−3 and 1338 ± 20 kg⋅m−3 and specific heats of 1209 ± 93 J⋅kg−1⋅K−1 and 1800 ± 96 J⋅kg−1⋅K−1, respectively. The results suggest to carry out more measurements, especially of specific heat given the scarce local and international information on vernacular building materials.
- Open Access
- 1 April 2020
- Published by SciELO Agencia Nacional de Investigacion y Desarrollo (ANID) in Información tecnológica
- Vol. 31 (2) , 173-186
Diseño de un módulo experimental bioclimático obtenido a partir del análisis de simulaciones térmicas para el centro poblado de Imata (4519 m s.n.m.) ubicado en Arequipa, Perú
En base a simulaciones térmicas dinámicas con el software EnergyPlus se propone un módulo experimental de un espacio habitable para el poblado de Imata, Perú, a 4519 msnm, con condiciones climáticas severas de muy bajas temperaturas. Se realizó simulaciones para cinco configuraciones del módulo, añadiendo sucesivamente componentes bioclimáticas, tales como mejoras en el aislamiento de la envolvente, tragaluz e invernadero adosado. Para el mes de más bajas temperaturas, la temperatura media en el módulo de mejor configuración es 11 °C superior a la temperatura media en el módulo correspondiente a espacios habitables típicos de Imata. La temperatura nocturna promedia mínima es 18.4 °C superior a la correspondiente temperatura exterior (- 4 °C). Para mantener en el interior una temperatura de 16.3 °C (modelo adaptivo), se requiere, en promedio anual, una energía diaria de 12 kWh para el módulo típico y 1 kWh para el mejor diseño.
- 1 April 2020
- Published by SciELO Agencia Nacional de Investigacion y Desarrollo (ANID) in Información tecnológica
- Vol. 31 (2) , 173-186
Open AccessDiseño de un módulo experimental bioclimático obtenido a partir del análisis de simulaciones térmicas para el centro poblado de Imata (4519 m s.n.m.) ubicado en Arequipa, Perú
En base a simulaciones térmicas dinámicas con el software EnergyPlus se propone un módulo experimental de un espacio habitable para el poblado de Imata, Perú, a 4519 msnm, con condiciones climáticas severas de muy bajas temperaturas. Se realizó simulaciones para cinco configuraciones del módulo, añadiendo sucesivamente componentes bioclimáticas, tales como mejoras en el aislamiento de la envolvente, tragaluz e invernadero adosado. Para el mes de más bajas temperaturas, la temperatura media en el módulo de mejor configuración es 11 °C superior a la temperatura media en el módulo correspondiente a espacios habitables típicos de Imata. La temperatura nocturna promedia mínima es 18.4 °C superior a la correspondiente temperatura exterior (- 4 °C). Para mantener en el interior una temperatura de 16.3 °C (modelo adaptivo), se requiere, en promedio anual, una energía diaria de 12 kWh para el módulo típico y 1 kWh para el mejor diseño.